1000 resultados para sistemas wetland


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objetivou-se estudar o efeito da taxa de carregamento sobre a eficiência de sistemas alagados, construídos de escoamento horizontal subsuperficial (SAC-EHSS), em remover poluentes de esgoto sanitário. Os SAC-EHSS foram alimentados com efluente proveniente de tanque séptico, sob taxas de carregamento orgânico volumétrico (TCO V) de 53 a 231 g m-3d-1 de demanda química de oxigênio (DQO total) e as associadas taxas de carregamento (TC V) de demanda química de oxigênio solúvel, sólidos suspensos totais (SST), nitrogênio total (N-Total) e fósforo total (P-Total). Para avaliação de desempenho dos SAC-EHSS, as mesmas variáveis foram quantificadas em seu efluente. Relação linear e positiva foi obtida entre as taxas de remoção de DQO total, DQO solúvel e SST, e as TC V, nas faixas em que foram aplicadas, além de não terem sido observados efeitos negativos desta variável sobre a eficiência na remoção desses poluentes. As taxas de remoção de N-Total e P-Total não apresentaram, entretanto, tendência de aumento com a TC V aplicada nos SAC- EHSS, cultivados com taboa e utilizados no tratamento de efluente sanitário. As cargas aplicadas desses nutrientes devem ser consideradas referenciais no dimensionamento desses sistemas, caso se queira maximizar a remoção global de poluentes da água residuária.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A large proportion of fresh water is greatly impaired due to increasing pollution; this could be minimized through the expansion of investment in sanitation programs. But the major problem faced by third world countries and developing ones in this respect, is the high cost of projects and their implementation. In an attempt to find a simple technology, efficient and inexpensive, this study aimed to verify the effectiveness of using constructed wetland systems (CWS) for removal of bacteria and nutrients from sanitary sewer effluent from the STS Piracicamirim - Piracicaba - SP. The installation of prototypes was followed, and testing prior to regularize the flow held, but due to malfunction of these and outages of the STS activity can not evaluate the effectiveness of both as to the parameters proposed: temperature, pH, dissolved oxygen, conductivity, total dissolved solids (TDS), nitrite, nitrate, ammonia, total nitrogen, total phosphorus, chemical oxygen demand (COD), sulfide, sulfate, biochemical oxygen demand (BOD), total coliform and Escherichia coli. To establish results about the effectiveness of these types if the system were conducted literature reviews of papers published with the same theme. Analysis of these results showed fairly good efficiencies in wastewater treatment, especially for nutrients and coliforms

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Human development and population growth during the twentieth century increased the water demand, tripling its consumption between 1950 and 1990. As the water streams were polluted; and as water is the source of minerals and also regulates vital functions, it becomes the vehicle of transmission and consequently spreads many diseases. Probably, the industries are the major responsible for this pollution when they dump untreated effluents to water streams, saturating the already insufficient net of sanitation facilities polluting water and soil. An effective treatment has been established with low cost in Europe and the United States, through constructed systems on wetlands Constructed Wetland Systems - CWSs, gradually used in other countries in the last three decades. Lately, we observe a continuous growth in Brazilian poultry business, and poultry industry showed greatest dynamism in the country, following the global market. Pondering this information and the efficiency of such treatment, this work aimed to study prototypes, in a laboratory scale, simulating ascending and descending types of CWSs, vegetated with aquatic macrophytes Eichhornia crassipes and the uses of aggregates and soil, to treat industrial wastewater from slaughterhouses and aviary. We conducted the initial characterization of the effluent to have an idea of its constituents and to scale the system and the continuous flow. Furthermore, we characterized the soil to be used in this system. The collects are periodically made in the refrigeration industry FRICOCK FRIGORIFICAÇÃO AVICULTURA INDÚSTRIA E COMÉRCIO LTDA. for local treatment simulation. The effluent that was treated with 12 prototypes of CWSs are analyzed with some frequency. The results of these reviews were compared to the effluent coming from the industry... (Complete abstract click electronic access below)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Water is an essential element for life. The use of this element, to support the community, defines it as water resource. This feature is being misused and degraded by the dumping of highly contaminated effluents. The impoverishment of its quality poses a risk to human consumption. The necessity to manage this resource, treating the wastewater properly, requires the constant improvement of treatment systems. Another need is to adjust the cost of systems to the demands of communities with less financial clout. This study aimed to adapt and understand the systems of wetlands, improving its efficiency, in an attempt to collaborate with the enrichment of this technology. The practical evidence, with lab-scale prototypes, assembled in ETE Piracicamirim with urban sewage effluent contributed to highlight the problems and operating system design. The bibliographic review showed that several studies had effectiveness for treatment. But it was evident the need for better understanding of dimensioning definitions that better attempted to the answers into the project. Moreover, standardization of system conditions for the specific wastewater treatment is an interesting field, identified, for future studies yet contribute to environmental engineering and sanitation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A trial was carried out to evaluate the chemical composition in the aerial part of lettuce, cv. 'Elisa', irrigated with wastewater treated with constructed wetland and source deposit water, grown on a Rhodic Hapludox Soil, using the irrigation systems sprinkle, subsurface drip and surface drip irrigation. The experiment was carried out from August 17th to October 3rd of 2001 and the chemical analyses of the lettuce were accomplished to 47 days after transplanting of the seedling. The aerial part of the lettuce was analyzed as for the levels of total nitrogen, nitrate, phosphorus, potassium, calcium, magnesium, sulfur, iron, manganese, copper, zinc, sodium, boron, cobalt and molybdenum. The sodium and the sulfur presented higher levels than the maximum suitable in the aerial part of the lettuce and the smallest level of magnesium, while other chemical elements analyzed were normal and appropriate considering the standard for well-nourished plants, not being influenced by the water type. The sodium was the chemical element that presented the highest levels in the aerial part of the lettuce in the treatments irrigated with wastewater, presenting significant difference in relationship to the treatments irrigated with source deposit water in the three irrigation systems. The use of the different irrigation systems by the application of wastewater treated with constructed wetland did not interfere in the levels of nutrients in the aerial part of the lettuce.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wetlands systems are considered nowadays as a treatment method that uses simple, easy operation and low cost technology, which has been used in various parts of the world and also in Brazil. Used alone or as a complement to other types of treatment systems, once it effectively removes nutrients, pathogens and other pollutants in the water. Due to the high complexity found in wetlands, making it difficult to predict the response of the system to treat wastewater, one should consider as ideal to base the sizing of the wetland system over the necessary removal of this parameter instead of scaling it from empiricism. The study was conducted to determine the coefficient of bacterial decrease in the Wetland unit located at Ponta Negra Station Sewage Treatment, located in Natal, the coastal region of Rio Grande do Norte. The most representative model to determine the bacterial decrease in this system was the one from Chick for hydraulic piston system. Kb of 0.37 d-1 were found for the flow rate of 15m³/d, while for the system operating at maximum design flow, 30m³/d, the Kb of 0.98 d-1 was found

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to develop a detailed econometric analysis to compare a constructed wetland system - combined model, and a waste stabilization pond system - facultative pond, as a function of six different sizes of finishing pig farms and two waste management systems - wet and dry. The constructed wetland system using dried waste management showed the best economic results. This finding is due to the low-cost implementation a year both per animal and per kilogram of meat. This system also required the smallest area for waste treatment. The use of stabilization pond with wet waste management system showed a lower implementation cost a year per animal and per kilogram of meat, but it required large areas. The econometric analysis of both systems of wastewater treatment revealed an economy of scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A concentração demográfica e de sistemas coletivos de esgotamento sanitário dentro do perímetro urbano da maioria dos municípios brasileiros, dificulta a viabilização do fornecimento de serviços de tratamento de esgotos domésticos à habitações e núcleos habitacionais isolados situados em áreas periurbanas e rurais, intensificando os danos provocados pela poluição de origem antrópica ao meio ambiente e à preservação da saúde pública. Para contribuir no equacionamento deste problema, o presente estudo teve por finalidade avaliar uma wetland construída híbrida em escala real, composta por uma unidade com fluxo contínuo subsuperficial vertical seguida por uma unidade de fluxo contínuo subsuperficial horizontal, cultivadas com capim Vetiver, para o tratamento de efluente proveniente de tanque séptico. A presente configuração experimental busca uma solução de baixo custo e simplificada para o tratamento descentralizado de esgotos domésticos. A estação experimental de tratamento de esgotos, parte integrante e um dos produtos da Rede Nacional de Tratamento de Esgotos Descentralizados RENTED, foi construída no Centro Tecnológico de Hidráulica CTH / Escola Politécnica EPUSP, campus Butantã da USP, em São Paulo. O esgoto bruto foi proveniente do Conjunto Residencial da USP e do restaurante central da Cidade Universitária. As vazões média e máxima de esgoto bruto, respectivamente, de 640L.d-1 e 1600L.d-1, foram aplicadas à entrada do TS de 5.000L e deste escoaram por gravidade à entrada da wetland construída híbrida, com TDH total de 2,8d e 1,1d, respectivamente, sob aplicação das vazões média e máxima de projeto. O monitoramento do experimento em campo, incluindo o período inicial de partida, durou 6 meses consecutivos. Foram avaliados os parâmetros físico-químicos e microbiológicos do esgoto bruto e do efluente do tanque séptico e das câmaras da wetland construída híbrida durante 97 dias consecutivos. Os resultados indicaram que tanto as mudas jovens quanto as adultas de capim Vetiver adaptaram-se bem às condições ambientais. As eficiências médias de remoção no efluente tratado final quanto à matéria orgânica carbonácea foram de 96 por cento para DBO5,20 e 90 por cento para DQO, 40 por cento para N-total, 23 por cento para N-amoniacal total, 60 por cento para P-total, 52 por cento para P-PO4, 74 por cento para SST, 96 por cento para SSV, 75 por cento para sólidos sedimentáveis, 44 por cento para SDV, 88 por cento para sulfeto total, e 97 por cento para óleos e graxas totais, variando entre 73 por cento a 100 por cento . Cerca de 80 por cento da fração orgânica da matéria nitrogenada presente no esgoto bruto foi removida. A remoção de coliformes termotolerantes foi, em média, de 2 e 3 unidades log, e de Escherichia Coli, média de 1 e 3 unidades log, respectivamente, sob aplicação das vazões máxima e média, Giardia sp, média de 99,995 por cento , Cryptosporidium sp, média de 98,7 por cento , Enterovírus, média de 99,6 por cento , e Ascaris sp, média de 0,10 ovo/L. A remoção de sulfetos propiciou a geração de efluente tratado sem odores desagradáveis. A diminuição da vazão aplicada e a elevação do TDH influenciaram positivamente no desempenho do sistema com relação às remoções dos parâmetros físico-químicos e microbiológicos. Com base no presente estudo, ficou evidente o benefício da associação de wetlands construídas com fluxo vertical e horizontal no tratamento de efluente de tanque séptico. O capim Vetiver apresentou bom potencial de utilização em wetlands 8 construídas para tratamento de esgotos domésticos. O sistema experimental de tratamento apresentou flexibilidade operacional, mantendo bom desempenho inclusive nos períodos de sobrecarga. A qualidade do efluente tratado final obtido no presente estudo atende às exigências de lançamento e aos padrões de emissão de efluentes líquidos em corpos dágua e em sistemas públicos de esgotamento sanitário definidos na legislação ambiental federal e do Estado de São Paulo. A tecnologia de wetlands construídas híbridas associada ao tratamento de efluentes de tanque séptico apresentou bom potencial para o tratamento descentralizado de esgotos domésticos, inclusive em regiões com pouca disponibilidade de área livre.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study focus on the reconfiguration of educational management in Argentina, Brazil, Chile and Mexico, which was promoted by the new logic of social regulation and the new role attributed to the State, considering each country's own historicity. So, the cultural factors that interfere on the dynamics of the 90' school reform are analyzed. Aspects that show the homogeneity or heterogeneity of these reforms in the region, as well as local specificities that block out the concretization of the reform are underlined. It is shown that the historicity that characterizes the educational reform has taken, in each country, a form that can be called, in Mexico, conservative rupture; in Chile, conservative continuity; in Brazil, conservative renovation; and, in Argentina, interrupted rupture. Some conclusions about the impact of educational reform in the selected countries are recuperated through the analysis of 186 academic texts on the subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By the year 2005 the world biochemical market will reach an estimated $ 100 billion and separation processes are a vital link between lab discoveries and the fulfillment of this commercialization potential. The practical application of aqueous two-phase systems (ATPS) to extraction processes has been exploited for several years for the recovery of biological products. Unfortunately, this has not resulted in an extensive presence of the technique in commercial processes. In this paper a critical overview of the fundamental thermodynamic properties related to formation of aqueous two-phase systems and their application to extraction and purification of bioparticules is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main referring subjects to the solar energy is how to compare it economically with other sources of energy, as much alternatives as with conventionals (like the electric grid). The purpose of this work was to develop a software which congregates the technical and economic main data to identify, through methods of microeconomic analysis, the commercial viability in the sizing of photovoltaic systems, besides considering the benefits proceeding from the proper energy generation. Considering the period of useful life of the components of the generation system of photovoltaic electricity, the costs of the energy proceeding from the conventional grid had been identified. For the comparison of the conventional sources, electric grid and diesel generation, three scenes of costs of photovoltaic panels and two for the factor of availability of diesel generation had been used. The results have shown that if the cost of the panels is low and the place of installation is more distant of the electric grid, the photovoltaic system becomes the best option.