904 resultados para sinus rhythm
Resumo:
Atrial fibrillation (AF) is the most common tachyarrhythmia and is associated with substantial morbidity, increased mortality and cost. The treatment modalities of AF have increased, but results are still far from optimal. More individualized therapy may be beneficial. Aiming for this calls improved diagnostics. Aim of this study was to find non-invasive parameters obtained during sinus rhythm reflecting electrophysiological patterns related to propensity to AF and particularly to AF occurring without any associated heart disease, lone AF. Overall 240 subjects were enrolled, 136 patients with paroxysmal lone AF and 104 controls (mean age 45 years, 75% males). Signal measurements were performed by non-invasive magnetocardiography (MCG) and by invasive electroanatomic mapping (EAM). High-pass filtering techniques and a new method based on a surface gradient technique were adapted to analyze atrial MCG signal. The EAM was used to elucidate atrial activation in patients and as a reference for MCG. The results showed that MCG mapping is an accurate method to detect atrial electrophysiologic properties. In lone paroxysmal AF, duration of the atrial depolarization complex was marginally prolonged. The difference was more obvious in women and was also related to interatrial conduction patterns. In the focal type of AF (75%), the root mean square (RMS) amplitudes of the atrial signal were normal, but in AF without demonstrable triggers the late atrial RMS amplitudes were reduced. In addition, the atrial characteristics tended to remain similar even when examined several years after the first AF episodes. The intra-atrial recordings confirmed the occurrence of three distinct sites of electrical connection from right to left atrium (LA): the Bachmann bundle (BB), the margin of the fossa ovalis (FO), and the coronary sinus ostial area (CS). The propagation of atrial signal could also be evaluated non-invasively. Three MCG atrial wave types were identified, each of which represented a distinct interatrial activation pattern. In conclusion, in paroxysmal lone AF, active focal triggers are common, atrial depolarization is slightly prolonged, but with a normal amplitude, and the arrhythmia does not necessarily lead to electrical or mechanical dysfunction of the atria. In women the prolongation of atrial depolarization is more obvious. This may be related to gender differences in presentation of AF. A significant minority of patients with lone AF lack frequent focal triggers, and in them, the late atrial signal amplitude is reduced, possibly signifying a wider degenerative process in the LA. In lone AF, natural impulse propagation to LA during sinus rhythm goes through one or more of the principal pathways described. The BB is the most common route, but in one-third, the earliest LA activation occurs outside the BB. Susceptibility to paroxysmal lone AF is associated with propagation of the atrial signal via the margin of the FO or via multiple pathways. When conduction occurs via the BB, it is related with prolonged atrial activation. Thus, altered and alternative conduction pathways may contribute to pathogenesis of lone AF. There is growing evidence of variability in genesis of AF also within lone paroxysmal AF. Present study suggests that this variation may be reflected in cardiac signal pattern. Recognizing the distinct signal profiles may assist in understanding the pathogenesis of AF and identifying subgroups for patient-tailored therapy.
Resumo:
Background: In most patients with chronic heart failure (CHF), endurance training improves exercise capacity. However, some patients do not respond favourably. The purpose of this study was to explore the reasons of non-response and to determine their predictive value.Methods: We studied a cohort of 120 consecutive CHF patients with sinus rhythm (mean age 57 ± 12 years, ejection fraction 29.3 ± 9.9%, peak VO2 17.3 ± 5.1 ml/min/kg), participating in a 3-month outpatient cardiac rehabilitation programme. Responders were defined as subjects who improved peak VO2 by more than 5%, work load by more than 10%, or VE/VCO2 slope by more than 5%. Subjects who did not fulfil at least one of the above criteria were characterized as non-responders. Multivariate regression analyses were performed to identify parameters that were predictive for a response. Receiver operating characteristic (ROC) analyses were performed for predictive parameters to identify thresholds for response or non-response.Results: Multivariate regression analyses revealed heart rate (HR) reserve, HR recovery at 1 min, and peak HR as significant predictors for a positive training response. ROC curves revealed the optimal thresholds separating responders from non-responders at less than 30 bpm for HR reserve, less than 6 bpm for HR recovery and less than 101 bpm for peak HR.Conclusions: The presence of impaired chronotropic competence is a major predictor of poor training response in CHF patients with sinus rhythm.
Resumo:
This open learning zone article examines the cardiac cycle and the interpretation of cardiac rhythm strips. The article begins with a brief revision of related physiology followed by a description of normal sinus rhythm and the main cardiac rhythm abnormalities. The article concludes by providing easy to follow steps for use in the interpretation of cardiac rhythm strips with practice examples presented in the CPD task section.
Resumo:
INTRODUCTION Rhythm disturbances in children with structurally normal hearts are usually associated with abnormalities in cardiac ion channels. The phenotypic expression of these abnormalities ("channelopathies") includes: long and short QT syndromes, Brugada syndrome, congenital sick sinus syndrome, catecholaminergic polymorphic ventricular tachycardia, Lènegre-Lev disease, and/or different degrees of cardiac conduction disease. METHODS The study group consisted of three male patients with sick sinus syndrome, intraventricular conduction disease, and monomorphic sustained ventricular tachycardia. Clinical data and results of electrocardiography, Holter monitoring, electrophysiology, and echocardiography are described. RESULTS In all patients, the ECG during sinus rhythm showed right bundle branch block and long QT intervals. First-degree AV block was documented in two subjects, and J point elevation in one. A pacemaker was implanted in all cases due to symptomatic bradycardia (sick sinus syndrome). Atrial tachyarryhthmias were observed in two patients. The common characteristic ventricular arrhythmia was a monomorphic sustained ventricular tachycardia, inducible with ventricular stimulation and sensitive to lidocaine. In one patient, radiofrequency catheter ablation was successfully performed. No structural abnormalities were found in echocardiography in the study group. CONCLUSION Common clinical and ECG features suggest a common pathophysiology in this group of patients with congenital severe electrical disease.
Resumo:
In an experimental model, variable and intermittent contact force (CF) resulted in a significant decrease in lesion volume. In humans, variability of CF during pulmonary vein isolation has not been characterized. Methods and Results-In 20 consecutive patients undergoing CF-guided circumferential pulmonary vein isolation, 914 radiofrequency applications (530 in sinus rhythm and 384 in atrial fibrillation) were analyzed. The variability of the 60% CF range (CF60%) was 17 ± 9.6 g. Hundred seventy-one (19%) applications were delivered with constant, 717 (78%) with variable, and 26 (3%) with intermittent CF. The mean CF and force-time integral were significantly higher during applications with variable than with intermittent or constant CF. There was no significant difference in CF variability, CF60% variability, and force-time integral between applications delivered in sinus rhythm and atrial fibrillation. The main reasons for CF variability were systolo-diastolic heart movement (29%) and respiration (27%). In 10 additional patients, during adenosine-induced atrioventricular block, the minimum CF significantly increased at 19 sites (5.3 ± 4.4 versus 13.4 ± 5.9 g; P < 0.001) and at 16 sites intermittent or variable CF became constant. At only 1 site systolo-diastolic movement remained the main reason for variable CF. Conclusions-CF during pulmonary vein isolation remains highly variable despite efforts to optimize contact. CF and CF parameters were similar during sinus rhythm and atrial fibrillation. The main reasons for CF variability are systolodiastolic heart movement and respiration. The systolo-diastolic peaks and nadirs of CF are because of ventricular contractions at the large majority of pulmonary vein isolation sites.
Resumo:
Atrial fibrillation is the most common arrhythmia requiring treatment. This Thesis investigated atrial fibrillation (AF) with a specific emphasis on atrial remodeling which was analysed from epidemiological, clinical and magnetocardiographic (MCG) perspectives. In the first study we evaluated in real-life clinical practice a population-based cohort of AF patients referred for their first elective cardioversion (CV). 183 consecutive patients were included of whom in 153 (84%) sinus rhythm (SR) was restored. Only 39 (25%) of those maintained SR for one year. Shorter duration of AF and the use of sotalol were the only characteristics associated with better restoration and maintenance of SR. During the one-year follow-up 40% of the patients ended up in permanent AF. Female gender and older age were associated with the acceptance of permanent AF. The LIFE-trial was a prospective, randomised, double-blinded study that evaluated losartan and atenolol in patients with hypertension and left ventricular hypertrophy (LVH). Of the 8,851 patients with SR at baseline and without a history of AF 371 patients developed new-onset AF during the study. Patients with new-onset AF had an increased risk of cardiac events, stroke, and increased rate of hospitalisation for heart failure. Younger age, female gender, lower systolic blood pressure, lesser LVH in ECG and randomisation to losartan therapy were independently associated with lower frequency of new-onset AF. The impact of AF on morbidity and mortality was evaluated in a post-hoc analysis of the OPTIMAAL trial that compared losartan with captopril in patients with acute myocardial infarction (AMI) and evidence of LV dysfunction. Of the 5,477 randomised patients 655 had AF at baseline, and 345 patients developed new AF during the follow-up period, median 3.0 years. Older patients and patients with signs of more serious heart disease had and developed AF more often. Patients with AF at baseline had an increased risk of mortality (hazard ratio (HR) of 1.32) and stroke (HR 1.77). New-onset AF was associated with increased mortality (HR 1.82) and stroke (HR of 2.29). In the fourth study we assessed the reproducibility of our MCG method. This method was used in the fifth study where 26 patients with persistent AF had immediately after the CV longer P-wave duration and higher energy of the last portion of atrial signal (RMS40) in MCG, increased P-wave dispersion in SAECG and decreased pump function of the atria as well as enlarged atrial diameter in echocardiography compared to age- and disease-matched controls. After one month in SR, P-wave duration in MCG still remained longer and left atrial (LA) diameter greater compared to the controls, while the other measurements had returned to the same level as in the control group. In conclusion is not a rare condition in either general population or patients with hypertension or AMI, and it is associated with increased risk of morbidity and mortality. Therefore, atrial remodeling that increases the likelihood of AF and also seems to be relatively stable has to be identified and prevented. MCG was found to be an encouraging new method to study electrical atrial remodeling and reverse remodeling. RAAS-suppressing medications appear to be the most promising method to prevent atrial remodeling and AF.
Resumo:
[EN]In this project has been developed a tool which synthesizes realistic waveforms produced by the intra-aortic balloon pump. In addition the following waveforms have also been synthesized: arterial blood pressure (ABP) waveform, the four variations produced due to timing errors of the balloon and the waveform of the helium gas rapidly shuttling in and out of the balloon chamber. All waveforms are synthesized in synchrony with the balloon's inflation/deflation cycles. A database composed of annotated ECG (Electrocardiogram) normal sinus rhythm records has also been created during the project. In order to facilitate the work, two graphical user interfaces were developed. The first interface allows the selection of the ECG records, which were latter annotated using the second interface. Starting from the newly created annotated database, the different waveforms, mentioned above, were synthesized. In this document, in view of the synthesized waveforms, it can be concluded that the obtained results are satisfactory.
Resumo:
OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?
DESIGN: Animal study.
SETTING: University research laboratory.
SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.
INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).
MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).
CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.
Resumo:
AIMS: Rheumatic heart disease (RHD) accounts for over a million premature deaths annually; however, there is little contemporary information on presentation, complications, and treatment.
METHODS AND RESULTS: This prospective registry enrolled 3343 patients (median age 28 years, 66.2% female) presenting with RHD at 25 hospitals in 12 African countries, India, and Yemen between January 2010 and November 2012. The majority (63.9%) had moderate-to-severe multivalvular disease complicated by congestive heart failure (33.4%), pulmonary hypertension (28.8%), atrial fibrillation (AF) (21.8%), stroke (7.1%), infective endocarditis (4%), and major bleeding (2.7%). One-quarter of adults and 5.3% of children had decreased left ventricular (LV) systolic function; 23% of adults and 14.1% of children had dilated LVs. Fifty-five percent (n = 1761) of patients were on secondary antibiotic prophylaxis. Oral anti-coagulants were prescribed in 69.5% (n = 946) of patients with mechanical valves (n = 501), AF (n = 397), and high-risk mitral stenosis in sinus rhythm (n = 48). However, only 28.3% (n = 269) had a therapeutic international normalized ratio. Among 1825 women of childbearing age (12-51 years), only 3.6% (n = 65) were on contraception. The utilization of valvuloplasty and valve surgery was higher in upper-middle compared with lower-income countries.
CONCLUSION: Rheumatic heart disease patients were young, predominantly female, and had high prevalence of major cardiovascular complications. There is suboptimal utilization of secondary antibiotic prophylaxis, oral anti-coagulation, and contraception, and variations in the use of percutaneous and surgical interventions by country income level.
Resumo:
OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.
Resumo:
La fibrillation auriculaire, l'arythmie la plus fréquente en clinique, affecte 2.3 millions de patients en Amérique du Nord. Pour en étudier les mécanismes et les thérapies potentielles, des modèles animaux de fibrillation auriculaire ont été développés. La cartographie électrique épicardique à haute densité est une technique expérimentale bien établie pour suivre in vivo l'activité des oreillettes en réponse à une stimulation électrique, à du remodelage, à des arythmies ou à une modulation du système nerveux autonome. Dans les régions qui ne sont pas accessibles par cartographie épicardique, la cartographie endocardique sans contact réalisée à l'aide d'un cathéter en forme de ballon pourrait apporter une description plus complète de l'activité auriculaire. Dans cette étude, une expérience chez le chien a été conçue et analysée. Une reconstruction électro-anatomique, une cartographie épicardique (103 électrodes), une cartographie endocardique sans contact (2048 électrodes virtuelles calculées à partir un cathéter en forme de ballon avec 64 canaux) et des enregistrements endocardiques avec contact direct ont été réalisés simultanément. Les systèmes d'enregistrement ont été également simulés dans un modèle mathématique d'une oreillette droite de chien. Dans les simulations et les expériences (après la suppression du nœud atrio-ventriculaire), des cartes d'activation ont été calculées pendant le rythme sinusal. La repolarisation a été évaluée en mesurant l'aire sous l'onde T auriculaire (ATa) qui est un marqueur de gradient de repolarisation. Les résultats montrent un coefficient de corrélation épicardique-endocardique de 0.8 (expérience) and 0.96 (simulation) entre les cartes d'activation, et un coefficient de corrélation de 0.57 (expérience) and 0.92 (simulation) entre les valeurs de ATa. La cartographie endocardique sans contact apparait comme un instrument expérimental utile pour extraire de l'information en dehors des régions couvertes par les plaques d'enregistrement épicardique.
Resumo:
Objectif: Déterminer si l’efficacité de l’amiodarone pour le maintien du rythme sinusal varie selon la fonction systolique ventriculaire gauche. Contexte: Malgré un profil de sécurité établi en insuffisance cardiaque, nous ignorons si l’efficacité de l’amiodarone et son impact sur différentes issues cardiovasculaires sont modulés par la fonction ventriculaire gauche. Méthode: Nous avons effectué une analyse combinée de 3307 patients (âgés de 68,0±0,9 ans ; 31,1% de femmes) recrutés dans les études AFFIRM et AF-CHF qui ont été randomisés au contrôle du rythme par l’amiodarone (N=1107) ou au contrôle de la fréquence cardiaque (N=2200). Résultats: Chez les patients sous amiodarone, la survie sans fibrillation auriculaire était de 84% et de 45% à 1 et 5 ans respectivement, sans égard à la fraction d’éjection ventriculaire gauche (P=0,8754, ajusté). De façon similaire, la proportion moyenne ajustée de temps en fibrillation auriculaire (15,0±1,8%) n’a pas été influencée par la fraction d’éjection (P=0,6094). Durant le suivi, 1963 patients (59,4%) ont requis au moins une hospitalisation, incluant 1401 (42,6%) patients hospitalisés pour cause cardiovasculaire. Les taux ajustés d’hospitalisation pour toutes causes et pour cause cardiovasculaire étaient similaires entre les patients sous amiodarone et ceux dans le groupe de contrôle de la fréquence dans l’ensemble de la population ainsi que dans les sous-groupes de patients avec et sans dysfonction ventriculaire gauche sévère. De façon similaire, les taux ajustés de mortalité globale et cardiovasculaire étaient similaires entre chez les patients sous amiodarone et ceux traités par le contrôle de la fréquence dans l’ensemble de la population ainsi que dans les sous-groupes de patients avec et sans dysfonction ventriculaire gauche sévère. Conclusions: L’efficacité de l’amiodarone pour le maintien du rythme sinusal n’est pas influencée par la fonction ventriculaire gauche. Le contrôle du rythme avec l’amiodarone s’associe à des taux de mortalité et d’hospitalisation comparables au contrôle de la fréquence à la fois chez les patients avec et sans dysfonction ventriculaire gauche sévère.
Resumo:
L’ablation de fibrillation auriculaire (FA) persistante est associée à des temps de procédure plus longs et à un moindre succès par rapport à l’ablation de FA paroxystique. Nous avons posé l’hypothèse que la restauration et le maintien du rythme sinusal ≥ 1 mois pré-procédure faciliteraient la terminaison de la FA et amélioreraient le succès de la procédure. Méthodes: Nous avons conduit une étude rétrospective comparant deux cohortes de patients consécutifs se présentant en FA persistante pour première ablation de FA : le groupe rythme sinusal (RS) avec restauration et maintien du rythme RS ≥ 1 mois pré-procédure (Groupe RS; N=40) et un groupe contrôle de patients en FA pré ablation (Groupe contrôle; N=40), apparié selon le sexe, l’âge, la longueur maximale de durée de FA. Une ablation de type en paliers (“stepwise”) a été réalisée dans les deux groupes (avec FA induite en début de procédure dans le groupe RS). Le succès a été défini par l’absence de récidive de FA ou de tachycardie atriale sans anti arythmique après un suivi minimal de 12 mois post procédure. Résultats: Durant la procédure de index d’ablation de FA, le cycle de FA était plus long dans le groupe RS par rapport au groupe contrôle (183±32 vs 166±20 ms, P=0.06) suggérant un remodelage inverse. Dans le groupe RS, la FA a été terminée plus fréquemment par l’ablation (95.0% vs 77.5%, P<0.05) et a demandé une ablation moins extensive avec moins d’ablation des électrocardiogrammes fragmentés (40.0% vs 87.5%, p<0.001) et moins de lésions linéaires (42.5% vs 82.5%, p<0.001). Les durées moyennes de procédure (199.8±69.8 vs 283.5±72.3 minutes, P<0.001), de fluoroscopie (51.0±24.9 vs 96.3±32.1 minutes, P<0.001), et de radiofréquence (47.5±18.9 vs 97.0±30.6 minutes, P<0.001) ont été plus courtes dans le groupe RS. Les succès cliniques ont été comparables dans les deux groupes après la première (55.0% vs 45.0%, P=0.28) et la dernière procédure (80.0% vs 70.0%, P=0.28), après une durée moyenne de suivi comparable (21.1±9.7 mois).
Resumo:
La pression artérielle est un déterminant potentiellement majeur de l’évolution de pathologies telles que la FA et l’insuffisance cardiaque. Pourtant, il demeure plusieurs incertitudes quant à la prise en charge optimale de la pression artérielle chez ces patients. Le rôle potentiel de la pression artérielle sur l’efficacité du maintien en rythme sinusal est inconnu. De plus, en présence d’insuffisance cardiaque, non seulement une pression artérielle élevée, mais aussi une pression artérielle basse pourrait augmenter la mortalité. Les travaux présentés ont pour but d’évaluer l’impact de la pression artérielle sur l’efficacité du contrôle du rythme et la mortalité ainsi que d’évaluer le rôle potentiel de l’insuffisance cardiaque sur cette interaction. Une étude post-hoc utilisant une banque de données combinant les études AFFIRM et AF-CHF a été réalisée. Les patients ont d’abord été classés selon leur FEVG (>40%, ≤40%), puis nous avons évalué l’impact de la PAS (<120 mmHg, 120-140 mmHg, >140 mmHg) sur les issues. Premièrement, chez les 2715 patients randomisés au contrôle du rythme, nous avons évalué la survie sans récidive de FA. Deuxièmement, chez tous les 5436 patients inclus dans les 2 études sources, nous avons évalué la mortalité et la morbidité. Chez les patients avec FEVG >40%, aucune des issues n’a été affectée par la PAS dans des analyses de régression multivariées de Cox. Par contraste, chez les patients avec FEVG ≤40%, le taux de récidive de FA était plus élevé avec une PAS >140 mmHg et une PAS <120 mmHg, par rapport à une PAS de 120-140 mmHg [HR, 1.47; IC 95% (1.12-1.93)] et [HR 1.15; IC 95% (0.92-1.43)], respectivement. La mortalité s’est également avérée augmentée chez ces patients avec une PAS >140 mmHg et une PAS <120 mmHg [HR 1.75; IC 95% (1.41-2.17)] et [HR 1.40; IC 95% (1.04-1.90)], respectivement. En conclusion, le maintien en rythme sinusal et la survie sont influencés par la PAS chez les patients avec FA et FEVG diminuée, mais non chez les patients avec FEVG normale. Une courbe en forme de U a été identifiée, où les pression plus basses (<120 mmHg) et plus hautes (>140 mmHg) sont associées à un moins bon pronostic.