996 resultados para single-shot
Resumo:
This prospective study compares repetitive thick-slab single-shot projection magnetic resonance cholangiopancreatography (MRCP) with endoscopic ultrasonography (EUS) for the detection of choledocholithiasis. Fifty-seven consecutive patients (36 women, mean age 61) referred for suspected choledocholithiasis underwent MRCP, followed by EUS. Each procedure was performed by different operators blinded to the results of the other investigation. MR technique included a turbo spin-echo T2-weighted axial sequence with selective fat saturation (SPIR/TSE, TE=70 ms, TR=1,600 ms), followed by coronal dynamic MRCP. The same thick-slab slice was sequentially acquired 12 times as breath-hold single-shot projection imaging (SSh, TE=900 ms, TE=8,000 ms) centred on the common bile duct (CBD). Two experienced radiologists independently and blindly evaluated MR images for the detection of CBD stones. Their inter-observer agreement kappa was determined. Secondly, the two observers read MR images in consensus again. CBD stones were demonstrated in 18 out of 57 patients (31.6 %) and confirmed by endoscopic retrograde cholangiography (ERCP, n=17) or intraoperative cholangiography (n=1). Clinical follow-up served as the "gold standard" in patients with negative results without following invasive procedure (n=28). Sensitivity, specificity, accuracy, positive and negative predictive value for MRCP resulting from consensus reading were 94.9%, 94.4%, 94.7%, 97.4% and 89.5%, respectively. Corresponding values of EUS were 97.4%, 94.4%, 96.5%, 97.4% and 94.4%. Inter-observer agreement kappa was 0.81. Repetitive thick-slab single-shot projection MRCP is an accurate non-invasive imaging modality for suspected choledocholithiasis and should be increasingly used to select those patients who require a subsequent therapeutic procedure, namely ERCP.
Resumo:
Introduction: Though a trial of intrathecal (IT) therapy should always be performed before implantation of a definitive intrathecal pump, there is no agreement as to how this test should be performed. Ziconotide is trialed in most of cases with continuous IT administration using implanted catheters. Unlike other intrathecal drugs, there is little experience with single bolus IT injections of ziconotide. The aim of the study is to assess the feasibility of single-shot IT trialing with ziconotide. Patients and methods: Eleven consecutive patients with chronic neuropathic intractable pain were trialed with a single IT bolus of 2.5 mcg of ziconotide. Pain and side effects are monitored for at least 72 hours after the injection. Depending on the response, a second injection is given a week later, with either the same dose (if VAS decreased ≥50% without side effects), a higher dose of 3.75 mcg (if VAS decreased <50% without side effects) or a lower dose of 1.25 mcg (if VAS decreased ≥50% but with side effects). If VAS decreased less than 50% and side effects occurred, no further injection was performed. When VAS decreased >50% without side effects after the first or the second dose, the result is confirmed by one more injection of the same dose one week later. The trial is considered positive if two successive injections provide a VAS decreased more than 50% without side effects. Results: Eleven patients (6 females and 5 males) were included. Nine patients experienced modest or no pain relief. Four of these had significant side effects (dizziness, nausea, vomiting or abdominal pain) and had no further injection. In the others 5, one patient retired from study and four received a second injection of 3.75 mcg. The trial was negative in all 5 cases because of side effects (dizziness, drowsiness, weakness, muscle cramps), the pain decreased in only 2 patients. Two patients experienced profound pain relief with an IT injection of 2.5 mcg. One patient had no side effects and the other had dizziness and drowsiness that disappeared with an injection of 1.25 mcg. Pain relief without adverse effects was confirmed with the second injection. The trial was considered positive for those two patients. Discussion and conclusion: The response rate of 18% (2/11) is consistent with the success rate of a continuous infusion trialing with an implanted catheter. Single-shot injection of ziconotide may therefore predict efficacy.
Resumo:
Given their high sensitivity and ability to limit the field of view (FOV), surface coils are often used in magnetic resonance spectroscopy (MRS) and imaging (MRI). A major downside of surface coils is their inherent radiofrequency (RF) B1 heterogeneity across the FOV, decreasing with increasing distance from the coil and giving rise to image distortions due to non-uniform spatial responses. A robust way to compensate for B1 inhomogeneities is to employ adiabatic inversion pulses, yet these are not well adapted to all imaging sequences - including to single-shot approaches like echo planar imaging (EPI). Hybrid spatiotemporal encoding (SPEN) sequences relying on frequency-swept pulses provide another ultrafast MRI alternative, that could help solve this problem thanks to their built-in heterogeneous spatial manipulations. This study explores how this intrinsic SPEN-based spatial discrimination, could be used to compensate for the B1 inhomogeneities inherent to surface coils. Experiments carried out in both phantoms and in vivo rat brains demonstrate that, by suitably modulating the amplitude of a SPEN chirp pulse that progressively excites the spins in a direction normal to the coil, it is possible to compensate for the RF transmit inhomogeneities and thus improve sensitivity and image fidelity.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.
Resumo:
We demonstrate a simple self-referenced single-shot method for simultaneously measuring two different arbitrary pulses, which can potentially be complex and also have very different wavelengths. The method is a variation of cross-correlation frequency-resolved optical gating (XFROG) that we call double-blind (DB) FROG. It involves measuring two spectrograms, both of which are obtained simultaneously in a single apparatus. DB FROG retrieves both pulses robustly by using the standard XFROG algorithm, implemented alternately on each of the traces, taking one pulse to be ?known? and solving for the other. We show both numerically and experimentally that DB FROG using a polarization-gating beam geometry works reliably and appears to have no nontrivial ambiguities.
Resumo:
To maximise data output from single-shot astronomical images, the rejection of cosmic rays is important. We present the results of a benchmark trial comparing various cosmic ray rejection algorithms. The procedures assess relative performances and characteristics of the processes in cosmic ray detection, rates of false detections of true objects, and the quality of image cleaning and reconstruction. The cosmic ray rejection algorithms developed by Rhoads (2000, PASP, 112, 703), van Dokkum (2001, PASP, 113, 1420), Pych (2004, PASP, 116, 148), and the IRAF task xzap by Dickinson are tested using both simulated and real data. It is found that detection efficiency is independent of the density of cosmic rays in an image, being more strongly affected by the density of real objects in the field. As expected, spurious detections and alterations to real data in the cleaning process are also significantly increased by high object densities. We find the Rhoads' linear filtering method to produce the best performance in the detection of cosmic ray events; however, the popular van Dokkum algorithm exhibits the highest overall performance in terms of detection and cleaning.
Resumo:
Carbon fibre reinforced polymers (CFRP) are increasingly being used in the aerospace, automotive and defence industry due to their high specific stiffness and good corrosion resistance. In a modern aircraft, 50-60% of its structure is made up of CFRP material while the remainder is mostly a combination of metallic alloys (typically aluminium or titanium alloys). Mechanical fastening (bolting or riveting) of CFRP and metallic components has thus created a pressing requirement of drilling several thousand holes per aircraft. Drilling of stacks in a single-shot not only saves time, but also ensures proper alignment when fasteners are inserted, achieving tighter geometric tolerances. However, this requirement poses formidable manufacturing challenges due to the fundamental differences in the material properties of CFRP and metals e.g. a drill bit entering into the stack encounters brittle and abrasive CFRP material as well as the plastic behaviour of the metallic alloy, making the drilling process highly non-linear.
Over the past few years substantial efforts have been made in this direction and majority of the research has tried to establish links between how the process parameters (feed, depth of cut, cutting speed), tooling (geometry, material and coating) and the wear of the cutting tool affect the hole quality. Similarly, multitudes of investigations have been conducted to determine the effects of non-traditional drilling methods (orbital, helical and vibration assisted drilling), cutting zone temperatures and efficiency of chip extraction on the hole quality and rate of tool wear during single shot drilling of CFRP/alloy stacks.
In a timely effort, this paper aims at reviewing the manufacturing challenges and barriers faced when drilling CFRP/alloy stacks and to summarise various factors influencing the drilling process while detailing the advances made in this fertile research area of single-shot drilling of stack materials. A survey of the key challenges associated with avoiding workpiece damage and the effect these challenges have on tool design and process optimisation is presented. An in depth critique of suitable hole making methods and their aptness for commercialisation follows. The paper concludes by summarising the future work required to achieve repeatable, high quality single shot drilled holes in CFRP/alloy stacks.
Resumo:
Liver suppressor factor one (LSF-1) is a 40-kDa immunosuppressive protein in the serum of rats 60 days after orthotopic liver transplantation (OLT) between the nonrejector combination of DA donors into PVG; recipients. In the present study, the purification of proteins from rat OLT serum taken 60 days after transplantation Mras performed by affinity chromatography using the anti-LSF-1 polyclonal antibody (pAb). The assessment of column eluates using anti-LSF-1 and OLT serum was studied using rat heart and liver transplantation models. Rejection was not suppressed by the administration of OLT serum in heart or liver allografts. However, heart allografts treated with peak eluates (450 mu g single shot im, dissolved in Intralipos) taken from the affinity OLT serum survived significantly longer than untreated rats (median = 36.5 days; n = 7 vs 6.5 days; n = 5, respectively, P = 0.011). The same treatment with anti-LSF-1 column eluates also prolonged liver allografts significantly (>200 days) than those in either the untreated group (median = 11 days; n = 7) or those which received only Intralipos (median = 10.5 days; n = 5, P = 0.019). Subsequent analysis of the N-terminal sequences of some of the proteins which were eluted from the affinity column revealed that the homology of a 30-kDa protein was identical to hemoglobin alpha-chain, a 59-kDa protein to granulocyte inhibitory factor, a 70-kDa and a 90-kDa to albumin and its precursor, respectively. Although the specific immunosuppressive component has not been isolated, our results suggested that the anti-LSF-1 column can extract immunosuppressive moiety of LSF-1 from OLT serum. (C) 1998 Academic Press.
Resumo:
O bloqueio contínuo de nervos periféricos (BCNP), descrito inicialmente em 1946 (1), consiste na colocação e utilização de um cateter percutâneo adjacente a um ou vários nervos periféricos para administração de anestésico local. A utilização de cateteres perineurais permite prologar a analgesia associada a técnica single shot, que dura, habitualmente, 24 horas. Apesar de bem estudado para analgesia no pos-operatório, o BCNP tem actualmente várias indicações descritas como tratamento de soluços(2), de vasospasmo associado a Doença de Raynaud (3), simpaticectomia e vasodilatação após cirurgia vascular (4), reimplantação de membros amputados(5), analgesia em trauma(6) e tratamento de dor cronica (7). Apesar de estar provado que no tratamento da dor pós-operatória o uso de cateteres perineurais permite uma analgesia mais eficaz comparativamente a analgesia com opióides sistémicos (reduzindo assim a incidência de complicações associadas ao uso destes) (8) e que melhora, a curto prazo, outcomes funcionais após cirurgia da extremidade, não esta evidenciado o beneficio desta técnica regional a longo prazo (9,10,11). Considerando a eficácia da técnica loco-regional para o tratamento da dor neuropática associada a doença arterial periférica (12,13) e a segurança associada ao bloqueio de nervo periférico (8,9,10,11), relata-se um caso de utilização desta técnica num doente para tratamento da agudização de dor crónica secundária a um agravamento da isquémia do membro inferior.
Resumo:
PURPOSE: To report the diffusion-weighted MRI findings in alveolar echinococcosis (AE) of the liver and evaluate the potential role of apparent diffusion coefficients (ADCs) in the characterisation of lesions. MATERIALS AND METHODS: We retrospectively included 22 patients with 63 AE liver lesions (≥1cm), examined with 3-T liver MRI, including a free-breathing diffusion-weighted single-shot echo-planar imaging sequence (b-values=50, 300 and 600s/mm(2)). Two radiologists jointly assessed the following lesion features: size, location, presence of cystic and/or solid components (according to Kodama's classification system), relative contrast enhancement, and calcifications (on CT). The ADCtotal, ADCmin and ADCmax were measured in each lesion and the surrounding liver parenchyma. RESULTS: Three type 1, 19 type 2, 17 type 3, three type 4 and 21 type 5 lesions were identified. The mean (±SD) ADCtotal, ADCmin and ADCmax for all lesions were 1.73±0.50, 0.76±0.38 and 2.63±0.76×10(-3)mm(2)/s, respectively. The mean ADCtotal for type 1, type 2, type 3, type 4 and type 5 lesions were 1.97±1.01, 1.76±0.53, 1.73±0.41, 1.15±0.42 and 1.76±0.44×10(-3)mm(2)/s, respectively. No significant differences were found between the five lesion types, except for type 4 (p=0.0363). There was a significant correlation between the presence of a solid component and low ADCmin (r=0.39, p=0.0016), whereas an inverse correlation was found between the relative contrast enhancement and ADCtotal (r=-0.34, p=0.0072). CONCLUSION: The ADCs of AE lesions are relatively low compared to other cystic liver lesions, which may help in the differential diagnosis. Although ADCs are of little use to distinguish between the five lesion types, their low value reflects the underlying solid component.
Resumo:
Purpose: To evaluate the feasibility, determine the optimal b-value, and assess the utility of 3-T diffusion-weighted MR imaging (DWI) of the spine in differentiating benign from pathologic vertebral compression fractures.Methods and Materials: Twenty patients with 38 vertebral compression fractures (24 benign, 14 pathologic) and 20 controls (total: 23 men, 17 women, mean age 56.2years) were included from December 2010 to May 2011 in this IRB-approved prospective study. MR imaging of the spine was performed on a 3-T unit with T1-w, fat-suppressed T2-w, gadolinium-enhanced fat-suppressed T1-w and zoomed-EPI (2D RF excitation pulse combined with reduced field-of-view single-shot echo-planar readout) diffusion-w (b-values: 0, 300, 500 and 700s/mm2) sequences. Two radiologists independently assessed zoomed-EPI image quality in random order using a 4-point scale: 1=excellent to 4=poor. They subsequently measured apparent diffusion coefficients (ADCs) in normal vertebral bodies and compression fractures, in consensus.Results: Lower b-values correlated with better image quality scores, with significant differences between b=300 (mean±SD=2.6±0.8), b=500 (3.0±0.7) and b=700 (3.6±0.6) (all p<0.001). Mean ADCs of normal vertebral bodies (n=162) were 0.23, 0.17 and 0.11×10-3mm2/s with b=300, 500 and 700s/mm2, respectively. In contrast, mean ADCs were 0.89, 0.70 and 0.59×10-3mm2/s for benign vertebral compression fractures and 0.79, 0.66 and 0.51×10-3mm2/s for pathologic fractures with b=300, 500 and 700s/mm2, respectively. No significant difference was found between ADCs of benign and pathologic fractures.Conclusion: 3-T DWI of the spine is feasible and lower b-values (300s/mm2) are recommended. However, our preliminary results show no advantage of DWI in differentiating benign from pathologic vertebral compression fractures.