912 resultados para side illumination fluorescence


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the position dependent tuning of fluorescence emission from rhodamine 6G doped polymethylmethacrylate film waveguide using a side illumination technique. The transmitted fluorescence as a function of the distance from the point of illumination is measured by translating the waveguide horizontally across a monochromatic light source. This technique has been utilized to characterize the optical loss in dye doped waveguides. We observe that the optical loss coefficients for shorter and longer distances of propagation through the dye doped waveguide are different. At longer distance of propagation a decrease in optical loss coefficient is observed

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The length-dependent tuning of the fluorescence spectra of a dye doped polymer fiber is reported. The fiber is pumped sideways and the fluorescence is measured from one of the ends. The excitation of a finite length of dye doped fiber is done by a diode pumped solid state laser at a wavelength of 532 nm. The fluorescence emission is measured at various positions of the fiber starting from a position closer to the pumping region and then progressing toward the other end of the fiber. We observe that the optical loss coefficients for shorter and longer distances of propagation through the dye doped fiber are different. At longer distances of propagation, a decrease in optical loss coefficient is observed. The fluorescence peaks exhibit a redshift of 12 nm from 589 to 610 nm as the point of illumination progresses toward the detector end. This is attributed to the self-absorption and re-emission of the laser dye in the fiber.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two-photon excited (TPE) side illumination fluorescence studies in a Rh6G-RhB dye mixture doped polymer optical fiber (POF) and the effect of energy transfer on the attenuation coefficient is reported. The dye doped POF is pumped sideways using 800 nm, 70 fs laser pulses from a Ti:sapphire laser, and the TPE fluorescence emission is collected from the end of the fiber for different propagation distances. The fluorescence intensity of RhB doped POF is enhanced in the presence of Rh6G as a result of energy transfer from Rh6G to RhB. Because of the reabsorption and reemission process in dye molecules, an effective energy transfer is observed from the shorter wavelength part of the fluorescence spectrum to the longer wavelength part as the propagation distance is increased in dye doped POF. An energy transfer coefficient is found to be higher at shorter propagation distances compared to longer distances. A TPE fluorescence signal is used to characterize the optical attenuation coefficient in dye doped POF. The attenuation coefficient decreases at longer propagation distances due to the reabsorption and reemission process taking place within the dye doped fiber as the propagation distance is increased.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pigments destroyed during photoinhibition of water-splitting photosystem II core complexes from the green alga Chlamydomonas reinhardtii were studied. Under conditions of a transiently inactivated donor side, illumination leads to an irreversible inhibition of the electron transfer at the donor side that is paralleled by the destruction of chlorophylls a absorbing maximally around 674 and 682 nm. The observed stochiometry of 1 +/- 0.1 destroyed chlorophyll per inhibited photosystem II suggests that chlorophyll destruction could be the primary photodamage causing the inhibition of photosystem II under these conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The spectral response and the photocurrent delivered by entirely microcrystalline p-i-n-Si:H detectors an analysed under different applied bias and light illumination conditions. The spectral response and the internal collection depend not only on the energy range but also on the illumination side. Under [p]- and [n]-side irradiation, the internal collection characteristics have an atypical shape. It is high for applied bias and lower than the open circuit voltage, shows a steep decrease near the open circuit voltage (higher under [n]-side illumination) and levels off for higher voltages. Additionally, the numerical modeling of the VIS/NIR detector, based on the band discontinuities near the grain boundaries and interfaces, complements the study and gives insight into the internal physical process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Experimental optoelectronic characterization of a p-i'(a-SiC:H)-n/pi(a-Si:H)-n heterostructure with low conductivity doped layers shows the feasibility of tailoring channel bandwidth and wavelength by optical bias through back and front side illumination. Front background enhances light-to-dark sensitivity of the long and medium wavelength range, and strongly quenches the others. Back violet background enhances the magnitude in short wavelength range and reduces the others. Experiments have three distinct programmed time slots: control, hibernation and data. Throughout the control time slot steady light wavelengths illuminate either or both sides of the device, followed by the hibernation without any background illumination. The third time slot allows a programmable sequence of different wavelengths with an impulse frequency of 6000Hz to shine upon the sensor. Results show that the control time slot illumination has an influence on the data time slot which is used as a volatile memory with the set, reset logical functions. © IFIP International Federation for Information Processing 2015.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Optically transparent cocatalyst film materials is very desirable for improved photoelectrochemical (PEC)oxygen evolution reaction (OER) over light harvesting photoelectrodes which require the exciting light to irradiate through the cocatalyst side, i.e., front-side illumination. In view of the reaction overpotential at electrode/electrolyte interface, the OER electrocatalysts have been extensively used as cocatalysts for PEC water oxidation on photoanode. In this work, the feasibility of a one-step fabrication of the transparent thin film catalyst for efficient electrochemical OER is investigated. The Ni-Fe bimetal oxide films, 200 nm in thickness, are used for study. Using a reactive magnetron co-sputtering technique, transparent(> 50% in wavelength range 500-2000 nm) Ni-Fe oxide films with high electrocatalytic activities were successfully prepared at room temperature. Upon optimization, the as-prepared bimetal oxide film with atomic ratio of Fe/Ni = 3:7 demonstrates the lowest overpotential for the OER in aqueous KOH solution, as low as 329 mV at current density of 2 mA cm 2, which is 135 and 108 mV lower than that of as-sputtered FeOx and NiOx thin films, respectively. It appears that this fabrication strategy is very promising to deposit optically transparent cocatalyst films on photoabsorbers for efficient PEC water splitting.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The rapid developments in fields such as fibre optic communication engineering and integrated optical electronics have expanded the interest and have increased the expectations about guided wave optics, in which optical waveguides and optical fibres play a central role. The technology of guided wave photonics now plays a role in generating information (guided-wave sensors) and processing information (spectral analysis, analog-to-digital conversion and other optical communication schemes) in addition to its original application of transmitting information (fibre optic communication). Passive and active polymer devices have generated much research interest recently because of the versatility of the fabrication techniques and the potential applications in two important areas – short distant communication network and special functionality optical devices such as amplifiers, switches and sensors. Polymer optical waveguides and fibres are often designed to have large cores with 10-1000 micrometer diameter to facilitate easy connection and splicing. Large diameter polymer optical fibres being less fragile and vastly easier to work with than glass fibres, are attractive in sensing applications. Sensors using commercial plastic optical fibres are based on ideas already used in silica glass sensors, but exploiting the flexible and cost effective nature of the plastic optical fibre for harsh environments and throw-away sensors. In the field of Photonics, considerable attention is centering on the use of polymer waveguides and fibres, as they have a great potential to create all-optical devices. By attaching organic dyes to the polymer system we can incorporate a variety of optical functions. Organic dye doped polymer waveguides and fibres are potential candidates for solid state gain media. High power and high gain optical amplification in organic dye-doped polymer waveguide amplifier is possible due to extremely large emission cross sections of dyes. Also, an extensive choice of organic dye dopants is possible resulting in amplification covering a wide range in the visible region.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The thesis presented the fabrication and characterisation of polymer optical fibers in their applications as optical amplifier and smart sensors.Optical polymers such as PMMA are found to be a very good host material due to their ability to incorporate very high concentration of optical gain media like fluorescent dyes and rare earth compounds. High power and high gain optical amplification in organic dye-doped polymer optical fibers is possible due to extremely large emission cross sections of oyes. Dye doped (Rhodamine 6G) optical fibers were fabricated by using indigenously developed polymer optical fiber drawing tower. Loss characterization of drawn dye doped fibers was carried out using side illumination technique. The advantage of the above technique is that it is a nondestructive method and can also be used for studying the uniformity in fiber diameter and doping. Sensitivity of the undoped polymer fibers to temperature and microbending were also studied in its application in smart sensors.Optical amplification studies using the dye doped polymer optical fibers were carried out and found that an amplification of l8dB could be achieved using a very short fiber of length lOcm. Studies were carried out in fibers with different dye concentrations and diameter and it was observed that gain stability was achieved at relatively high dye concentrations irrespective of the fiber diameter.Due to their large diameter, large numerical aperture, flexibility and geometrical versatility of polymer optical fibers it has a wide range of applications in the field of optical sensing. Just as in the case of conventional silica based fiber optic sensors, sensing techniques like evanescent wave, grating and other intensity modulation schemes can also be efficiently utilized in the case of POF based sensors. Since polymer optical fibers have very low Young's modulus when compared to glass fibers, it can be utilized for sensing mechanical stress and strain efficiently in comparison with its counterpart. Fiber optic sensors have proved themselves as efficient and reliable devices to sense various parameters like aging, crack formation, weathering in civil structures. A similar type of study was carried out to find the setting characteristics of cement paste used for constructing civil structures. It was found that the measurements made by using fiber optic sensors are far more superior than that carried out by conventional methods. More over,POF based sensors were found to have more sensitivity as well.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyze the linewidth narrowing in the fluorescence spectrum of a two-level atom driven by a squeezed vacuum field of a finite bandwidth. It is found that the fluorescence spectrum in a low-intensity squeezed field can exhibit a (omega - omega(0))(-6) frequency dependence in the wings. We show that this fast fall-off behavior is intimately related to the properties of a narrow-bandwidth squeezed field and does not extend into the region of broadband excitation. We apply the Linear response model and find that the narrowing results from a convolution of the atom response with the spectrum of the incident field. On the experimental side, we emphasize that the linewidth narrowing is not sensitive to the solid angle of the squeezed modes coupled to the atom. We also compare the fluorescence spectrum with the quadrature-noise spectrum and find that the fluorescence spectrum for an off-resonance excitation does not reveal the noise spectrum. We show that this difference arises from the competing three-photon scattering processes. [S1050-2947(98)04308-X].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conformational changes of channel activation: Five enhanced green fluorescent protein (EGFP) molecules (green cylinders) were integrated into the intracellular part of the homopentameric ionotropic 5-HT3 receptor. This allowed the detection of extracellular binding of fluorescent ligands (?) to EGFP by FRET, and also enabled the quantification of agonist-induced conformational changes in the intracellular region of the receptor by homo-FRET between EGFPs. The approach opens novel ways for probing receptor activation and functional screening of therapeutic compounds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapport de synthèse : Introduction : Les premières applications cliniques de la thérapie photodynamique (PDT) remontent à plus d'une vingtaine d'années. Basée sur l'activation d'un médicament photosensibilisateur par une source lumineuse à une longueur d'onde spécifique, la PDT permet la destruction sélective de tissus contenant le produit actif. Ce procédé a été expérimenté dans le traitement de cancers en raison de la propriété du médicament à se concentrer dans les tumeurs tout en épargnant les structures normales contigües. Cependant, les photosensibilisateurs utilisés jusqu'à ce jour n'ont pas démontré une accumulation exclusive dans les tissus néoplasiques mais également dans les structures saines avoisinantes induisant une destruction tissulaire non sélective. Notamment, d'importantes complications ont été rapportées suite à l'utilisation de la PDT dans la cavité thoracique après la résection de mésothéliomes pleuraux, et ce malgré l'arrivée de photosensibilisateurs de secondes générations. De ce fait, plusieurs études expérimentales ont été menées afin d'améliorer la sélectivité tumorale du médicament en modulant différentes conditions de traitement et en modifiant la structure du photosensibilisateur par pégylation. Le but de cette étude expérimentale est de corréler l'activité photodynamique, la phototoxicité et la distribution du m-tetrahydroxyphenylchlorin (mTHPC) et de sa forme pégylée, le PEG-mTHPC. De ce fait, un modèle de souris nues porteur de xenogreffes de mésothéliome humain a été utilisé pour étudier les deux photosensibilisateurs. De récents travaux avec ce modèle ont montré que la mesure de la concentration tissulaire du mTHPC et de sa forme pégylée par HPLC restait limitée afin de prédire l'activité photodynamique. De ce fait, nous pensons que les mesures de fluorescence peuvent être plus appropriée. Le signalement fluorescent est mesuré dans le tissu tumoral et dans une région contrôle de la peau afin d'étudier la distribution et l'intensité des deux sensibilisateurs. Méthode : Des souris nues (cd1nu/nu mice) de 8 semaines ont été transplantées avec des fragments de mésothéliome malin humain (H-meso-1). Ces derniers ont été obtenus à partir d'une suspension cellulaire. Au moins trois passages ont été faits dans les animaux, avant que le traitement soit initié. Deux groupes de 6 souris chacun ont été utilisés pour l'injection intraveineuse par la queue du mTHPC à 0.15 mg/kg et du PEG-mTHPC à dose équimolaire. Après trois jour, la tumeur ainsi qu'une région contrôle de la cuisse ont été illuminées sur une surface d'un diamètre de 1.2 cm et pendant 133 secondes avec un laser à une longueur d'onde à 652 nm (fluence 20 J/cm2, fluence rate 150 mW/cm2). Les animaux ont été ensuite sacrifiés 72 heures après l'illumination. L'étendue de la nécrose tumorale et de la région contrôle ont été déterminées en aveugle par histomorphometrie par un pathologue (HJA). La fluorescence microscopique a été évaluée dans 12 souris à une concentration de 0.15 et 0.5 mg/kg pour le mTHPC, et à doses équimolaires pour le PEG-mTHPC. Trois animaux ont été injectés avec le mTHPC à 0.15 mg/kg, 3 autres à dose équimolaire avec la forme pégylée et 6 souris avec le mTHPC à 0.5 mg/kg et à dose équimolaire. Les animaux ont été sacrifiés 72 heures après injection. L'intensité fluorescente des sensibilisateurs a été mesurée dans la tumeur et la région contrôle. Suite à cela, les coupes ont été fixées par H&E et superposées aux images fluorescentes, afin de localiser la distribution des deux photosensibilisateurs dans les différents compartiments tissulaires. Six souris transplantées n'ayant ni été injectées avec les sensibilisateurs ou illuminées ont servi de groupe contrôle. Résultats : Trois jours après l'illumination, la PDT provoque une nécrose tumorale de 10 ±5.4 mm2 pour le mTHPC à 0.15mg/kg et 5.2 ± 4.6 mm2 pour sa forme pégylée à dose équimolaire. Cependant, la nécrose tumorale induite par les deux formulations du sensibilisateur est significativement plus élevée que dans le groupe contrôle (0.33 ± 0.58 mm2) (P=0.02). Toutefois, le mTHPC pégylé provoque une photosensibilité cutanée moins importante que la forme non-pegylée. Dans les deux groupes, aucune nécrose n'a été observée dans la cuisse des animaux. Trois jours après l'injection du mTHPC et de la forme pégylée à 0.15 mg/kg, aucune activité fluorescente n'a été détectée. Cependant, à 0.5 mg/kg, la fluorescence microscopique révèle une distribution hétérogène des deux photo-sensibilisateurs dans le tissu tumoral avec une accumulation prédominante dans les régions peri-vasculaires. Les deux médicaments montrent une distribution intracellulaire homogène dans le cytoplasme et une absence de signalement dans le nucleus. La mesure de l'intensité fluorescente du mTHPC à 0.5mg/kg ne montre pas de différence significative entre le tissu tumoral et la région contrôle. Par contre, le PEG-mTHPC montre une intensité fluorescente supérieure dans le tissu tumoral que dans la peau (ratio tumeur- peau 0.94 pour le mTHPC et 1.73 pour le PEG-mTHPC). Conclusion : L'utilisation du mTHPC à 0.15mg/kg induit une nécrose tumorale similaire à celle du PEG-mTHPC à dose équimolaire. Cependant, ce dernier démontre une photo-toxicité plus atténuée de la peau. La fluorescence microscopique permet de localiser les deux sensibilisateurs dans les différents compartiments tissulaires à partir d'une dose de 0.5 mg/kg. Le PEG-mTHPC induit un signalement fluorescent supérieur dans le tissu tumoral par rapport à la peau. La mesure du signalement fluorescent a le potentiel de prédire l'activité photodynamique du mTHPC et de sa forme pégylée dans les xénogreffes de mésothéliome humain dans un modèle de souris nue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a system with two epi-illumination sources, a DC-regulated lamp for transillumination and mechanical switches for rapid shift of illumination and detection of defined areas (250-750 µm²) by fluorescence and phosphorescence videomicroscopy. The system permits investigation of standard microvascular parameters, vascular permeability as well as intra- and extravascular PO2 by phosphorescence quenching of Pd-meso-tetra (4-carboxyphenyl) porphine (PORPH). A Pechan prism was used to position a defined region over the photomultiplier and TV camera. In order to validate the system for in vivo use, in vitro tests were performed with probes at concentrations that can be found in microvascular studies. Extensive in vitro evaluations were performed by filling glass capillaries with solutions of various concentrations of FITC-dextran (diluted in blood and in saline) mixed with different amounts of PORPH. Fluorescence intensity and phosphorescence decay were determined for each mixture. FITC-dextran solutions without PORPH and PORPH solutions without FITC-dextran were used as references. Phosphorescence decay curves were relatively unaffected by the presence of FITC-dextran at all concentrations tested (0.1 µg/ml to 5 mg/ml). Likewise, fluorescence determinations were performed in the presence of PORPH (0.05 to 0.5 mg/ml). The system was successfully used to study macromolecular extravasation and PO2 in the rat mesentery circulation under controlled conditions and during ischemia-reperfusion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Walter D’Arcy Ryan was born in 1870 in Kentville, Nova Scotia. He became the chief of the department of illumination at the General Electric Company of Schenectady, New York. He was a founder in the field of electrical illumination. He built the electric steam scintillator which had numerous nozzles and valves. The operator would release steam through the valves. The nozzles all had names which included: Niagara, fan, snake, plume, column, pinwheel and sunburst. The steam scintillator was combined with projectors, prismatic reflectors, flashers and filters to produce the desired effects. In 1920 a group of businessmen from Niagara Falls, New York formed a group who called themselves the “generators’. They lobbied the American and Canadian governments to improve the illumination of the Falls. They were able to raise $58, 000 for the purchase and installation of 24 arc lights to illuminate the Falls. On February 24th, 1925 the Niagara Falls Illumination Board was formed. Initially, the board had a budget of $28,000 for management, operation and maintenance of the lights. The power was supplied free by the Ontario Power Company. They had 24 lights installed in a row on the Ontario Power Company surge tank which was next to the Refectory in Victoria Park on the Canadian side. The official opening ceremony took place on June 8th, 1925 and included a light parade in Niagara Falls, New York and an international ceremony held in the middle of the Upper Steel Arch Bridge. Walter D’Arcy Ryan was the illuminating engineer and A.D. Dickerson who was his New York field assistant directed the scintillator. with information from American Technological Sublime by David E. Nye and the Niagara Falls info website Location: Brock University Archives Source Information: Subject Headings: Added Entries: 100 Ryan, W. D’A. |q (Walter D’Arcy), |d 1870-1934 610 General Electric Company 650 Lighting, Architectural and decorative 650 Lighting |z New York (State) |z Niagara Falls 700 Dickerson, A.F. 700 Schaffer, J.W. Related material held at other repositories: The Niagara Falls Museum in Niagara Falls, Ontario has a program (pamphlet) dedicating new lighting in 1958 and it has postcards depicting the illumination of the Falls. Some of Ryan’s accomplishments can be seen at The Virtual Museum of the City of San Francisco. Described by: Anne Adams Date: Sept 26,Upper Steel Arch Bridge. Walter D’Arcy Ryan was the illuminating engineer and A.D. Dickerson who was his New York field assistant directed the scintillator. with information from American Technological Sublime by David E. Nye and the Niagara Falls info website