991 resultados para sick building syndrome
Resumo:
This paper describes the development and validation of a novel web-based interface for the gathering of feedback from building occupants about their environmental discomfort including signs of Sick Building Syndrome (SBS). The gathering of such feedback may enable better targeting of environmental discomfort down to the individual as well as the early detection and subsequently resolution by building services of more complex issues such as SBS. The occupant's discomfort is interpreted and converted to air-conditioning system set points using Fuzzy Logic. Experimental results from a multi-zone air-conditioning test rig have been included in this paper.
Resumo:
INTRODUCTION Rhythm disturbances in children with structurally normal hearts are usually associated with abnormalities in cardiac ion channels. The phenotypic expression of these abnormalities ("channelopathies") includes: long and short QT syndromes, Brugada syndrome, congenital sick sinus syndrome, catecholaminergic polymorphic ventricular tachycardia, Lènegre-Lev disease, and/or different degrees of cardiac conduction disease. METHODS The study group consisted of three male patients with sick sinus syndrome, intraventricular conduction disease, and monomorphic sustained ventricular tachycardia. Clinical data and results of electrocardiography, Holter monitoring, electrophysiology, and echocardiography are described. RESULTS In all patients, the ECG during sinus rhythm showed right bundle branch block and long QT intervals. First-degree AV block was documented in two subjects, and J point elevation in one. A pacemaker was implanted in all cases due to symptomatic bradycardia (sick sinus syndrome). Atrial tachyarryhthmias were observed in two patients. The common characteristic ventricular arrhythmia was a monomorphic sustained ventricular tachycardia, inducible with ventricular stimulation and sensitive to lidocaine. In one patient, radiofrequency catheter ablation was successfully performed. No structural abnormalities were found in echocardiography in the study group. CONCLUSION Common clinical and ECG features suggest a common pathophysiology in this group of patients with congenital severe electrical disease.
Resumo:
OBJECTIVES Individual mutations in the SCN5A-encoding cardiac sodium channel alpha-subunit cause single cardiac arrhythmia disorders, but a few cause multiple distinct disorders. Here we report a family harboring an SCN5A mutation (L1821fs/10) causing a truncation of the C-terminus with a marked and complex biophysical phenotype and a corresponding variable and complex clinical phenotype with variable penetrance. METHODS AND RESULTS A 12-year-old male with congenital sick sinus syndrome (SSS), cardiac conduction disorder (CCD), and recurrent monomorphic ventricular tachycardia (VT) had mutational analysis that identified a 4 base pair deletion (TCTG) at position 5464-5467 in exon 28 of SCN5A. The mutation was also present in six asymptomatic family members only two of which showed mild ECG phenotypes. The deletion caused a frame-shift mutation (L1821fs/10) with truncation of the C-terminus after 10 missense amino acid substitutions. When expressed in HEK-293 cells for patch-clamp study, the current density of L1821fs/10 was reduced by 90% compared with WT. In addition, gating kinetic analysis showed a 5-mV positive shift in activation, a 12-mV negative shift of inactivation and enhanced intermediate inactivation, all of which would tend to reduce peak and early sodium current. Late sodium current, however, was increased in the mutated channels. CONCLUSIONS The L1821fs/10 mutation causes the most severe disruption of SCN5A structure for a naturally occurring mutation that still produces current. It has a marked loss-of-function and unique phenotype of SSS, CCD and VT with incomplete penetrance.
Resumo:
Includes index.
Symptoms after mould exposure including Stachybotrys chartarum, and comparison with darkroom disease
Resumo:
P>Background: Mould-attributed symptoms have included features which overlap with unexplained syndromes such as sick building syndrome. Objectives: We describe questionnaire and chart review findings in patients following exposure to moulds which include Stachybotrys and compare responses with two control groups. Methods: Thirty-two patients presented with symptoms attributed to mould exposures. Exposure identification for 25 patients had reported S tachybotrys chartarum as well as other mould (Aspergillus, Penicillium), 88% at work. The remaining seven had professionally visualized or self-reported/photographic exposure evidence only. A chart review was performed and a follow-up with a questionnaire, including questions on current health status, and nonspecific symptoms. Results: Cough, shortness of breath and chest tightness (at presentation) were reported in 79%, 70% and 64%, respectively, and persisted > 6 weeks in 91%. Skin test(s) were positive to fungal extract(s) in 30%. Seventeen returned questionnaires were obtained 3.1 (SD 0.5) years after the initial clinic assessment. Among this subgroup, persisting asthma-like symptoms and symptoms suggestive of sick building syndrome were frequent, and similar to a group previously assessed for darkroom disease among medical radiation technologists. The mould-exposed group more commonly reported they were bothered when walking in a room with carpets, complained of a chemical or metallic taste in their mouth, and had problems in concentration when compared with a control physiotherapist group (P < 0.005). Conclusions: Although only a minority with health concerns from indoor mould exposure had demonstrable mould-allergy, a significant proportion had asthma-like symptoms. Other symptoms were also common and persistent after the initial implicated exposure.
Resumo:
Mestrado em Segurança e Higiene no Trabalho.
Resumo:
In Brazil, very little experimental work on measurements of indoor air pollutant levels has been done. Nowadays, increasing attention is being given to indoor air quality and the health problems associated with buildings and the indoor work environment. The scope of this paper is to review the major pollutants found in indoor environments and their sources. Subsequently, exposure to indoor air pollutants and health effects are considered. The review concludes by briefly addressing assessment of indoor air quality in Brazil and research needs.
Resumo:
During the last two decades there has been increasing concern within the scientific community related to the effects of indoor air quality on health. Changes in building design devised to improve energy efficiency and new synthetic building materials have contributed to increase pollutant concentrations. These factors have generated poor air quality and caused the development of a lot of symptoms known as Sick Building Syndrome (SBS). In Brazil, there are few studies in this area, collected in this review to support researches and awareness of the need to adopt preventive measures to reach a better quality for the Indoor Environment.
Resumo:
Un problema de salud ambiental relevante es la contaminación del aire generado por diferentes factores, uno de ellos es la carga microbiana. El estudio evidencia la presencia de estos contaminantes del aire como son los bioaerosoles cultivables y contables en las áreas de los edificios administrativos estudiados la cual podría afectar la calidad del aire interior. Se realizó un estudio observacional de corte transversal que permitió conocer y establecer las características de la carga microbiana presente relacionada con bioaerosoles cultivables y contables en los sistemas de ventilación mecánica en tres edificios administrativos de la ciudad de Bogotá en el periodo 2012 a 2013 y, la asociación o no entre variables de interés. Los bioaerosoles cultivables y contables encontrados con mayores porcentajes en las muestras tomadas fueron comunes a los tres edificios así: Aspergillus sp. se encontró en el 77,2% (61) de las muestras para el edifico uno, mientras que para el dos fue de 91% (30) de las muestras y para el edificio tres 100% (19) de las muestras tomadas; seguido por el género Penicillium sp. del cual se encontró 60,8% (48) de las muestras para el edificio uno, para el edificio dos 87,9% (29) de las muestras y para el edificio tres 94,7% (18) de las muestras. Otro género encontrado en porcentajes altos en los tres edificios fue el Cladosporium sp. , en el edificio uno 41,8% (33) de las muestras, mientras que para el edificio dos correspondió al 100% (33) de las muestra y finalmente para el edificio tres 84,2% (16) de las muestras analizadas. Los hallazgos se correlacionan con lo reportado por la literatura.
Resumo:
Buildings affect people in various ways. They can help us to work more effectively; they also present a wide range of stimuli for our senses to react to. Intelligent buildings are designed to be aesthetic in sensory terms not just visually appealing but ones in which occupants experience delight, freshness, airiness, daylight, views out and social ambience. All these factors contribute to a general aesthetic which gives pleasure and affects one’s mood. If there is to be a common vision, it is essential for architects, engineers and clients to work closely together throughout the planning, design, construction and operational stages which represent the conception, birth and life of the building. There has to be an understanding of how patterns of work are best suited to a particular building form served by appropriate environmental systems. A host of technologies are emerging that help these processes, but in the end it is how we think about achieving responsive buildings that matters. Intelligent buildings should cope with social and technological changes and also be adaptable to short-term and long-term human needs. We live through our senses. They rely on stimulation from the tasks we are focused on; people around us but also the physical environment. We breathe air and its quality affects the olfactory system; temperature is felt by thermoreceptors in the skin; sound enters our ears; the visual scene is beheld by our eyes. All these stimuli are transmitted along the sensory nervous system to the brain for processing from which physiological and psychological reactions and judgments are formed depending on perception, expectancies and past experiences. It is clear that the environmental setting plays a role in this sensory process. This is the essence of sensory design. Space plays its part as well. The flow of communication is partly electronic but also largely by people meeting face to face. Our sense of space wants different things at different times. Sometimes privacy but other times social needs have to be satisfied besides the organizational requirement to have effective human communications throughout the building. In general if the senses are satisfied people feel better and work better.
Resumo:
Sick Building Syndrome is a prevalent problem with patient complaints similar to typical allergy symptoms. Unlike most household allergens, the Asp f 1 allergen is conceivably ubiquitous in the work environment. This project examined levels of the Asp f 1 allergen in office and non-industrial occupational environments, and studied the bioaerosol and dust reservoirs of Aspergillus fumigatus responsible for those levels. ^ Culturable bioaerosols of total mesophilic fungi were sampled with Andersen N6 impactors. Aggressive airborne and bulk dust samples were concurrently collected and assayed for Asp f 1. Bulk dusts were selectively cultured for A. fumigatus. Samples were collected during both wet and dry climatological conditions to examine the possibility of Asp f 1 increases due to fungal growth blooms. ^ Only very low levels of Asp f 1 were detected in relatively few samples. Analysis of wet versus dry period samples showed no differences in Asp f 1 levels, although A. fumigatus counts from dusts did fluctuate significantly with exterior moisture events as did indoor prevalence of total colony forming units. These results indicate that even in the presence of elevated fungal concentrations, levels of Asp f 1 are extremely low. These levels do not correlate with climatological moisture events, despite distinct fungal blooms in the days immediately following those events. Non-industrial office buildings devoid of indoor air quality issues did not demonstrate significant levels or occurrence of Asp f 1 contamination in the geographical region of this study. ^