187 resultados para shower


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been postulated that susceptible individuals may acquire infection with nontuberculous mycobacteria (NTM) from water and aerosol exposure. This study examined household water and shower aerosols of patients with NTM pulmonary disease. The mycobacteria isolated from clinical samples from 20 patients included M. avium (5 patients), M. intracellulare (12 patients), M. abscessus (7 patients), M. gordonae (1 patient), M. lentiflavum (1 patient), M. fortuitum (1 patient), M. peregrinum (1 patient), M. chelonae (1 patient), M. triplex (1 patient), and M. kansasii (1 patient). One-liter water samples and swabs were collected from all taps, and swimming pools or rainwater tanks. Shower aerosols were sampled using Andersen six-stage cascade impactors. For a subgroup of patients, real-time PCR was performed and high-resolution melt profiles were compared to those of ATCC control strains. Pathogenic mycobacteria were isolated from 19 homes. Species identified in the home matched that found in the patient in seven (35%) cases: M. abscessus (3 cases), M. avium (1 case), M. gordonae (1 case), M. lentiflavum (1 case), and M. kansasii (1 case). In an additional patient with M. abscessus infection, this species was isolated from potable water supplying her home. NTM grown from aerosols included M. abscessus (3 homes), M. gordonae (2 homes), M. kansasii (1 home), M. fortuitum complex (4 homes), M. mucogenicum (1 home), and M. wolinskyi (1 home). NTM causing human disease can be isolated from household water and aerosols. The evidence appears strongest for M. avium, M. kansasii, M. lentiflavum, and M. abscessus. Despite a predominance of disease due to M. intracellulare, we found no evidence for acquisition of infection from household water for this species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We observe a correlation between the slope of radio lateral distributions and the mean muon pseudorapidity of 59 individual cosmic-ray-air-shower events. The radio lateral distributions are measured with LOPES, a digital radio interferometer colocated with the multidetector-air-shower array KASCADE-Grande, which includes a muon-tracking detector. The result proves experimentally that radio measurements are sensitive to the longitudinal development of cosmic-ray air showers. This is one of the main prerequisites for using radio arrays for ultra-high-energy particle physics and astrophysics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La seguente tesi ha come scopo la progettazione e la realizzazione di un sistema intelligente per la gestione e il monitoraggio dell'acqua in impianti facenti uso di docce attraverso 'l'Internet Of Things', con l'obiettivo di ridurre gli sprechi favorendo cosi un risparmio sia di tipo energetico sia di tipo idrico. Stabiliti i requisiti si passa alla fase di progettazione dove vengono analizzate tutte le funzionalità che il sistema deve soddisfare. Segue la fase di implementazione, il cui scopo e realizzare concretamente le funzionalità producendo un prototipo iniziale. Quest'ultimo sara sottoposto ad eventuali test per verificare il corretto funzionamento del sistema e delle singole parti che lo costituiscono.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND There has been little research on bathroom accidents. It is unknown whether the shower or bathtub are connected with special dangers in different age groups or whether there are specific risk factors for adverse outcomes. METHODS This cross-sectional analysis included all direct admissions to the Emergency Department at the Inselspital Bern, Switzerland from 1 January 2000 to 28 February 2014 after accidents associated with the bathtub or shower. Time, age, location, mechanism and diagnosis were assessed and special risk factors were examined. Patient groups with and without intracranial bleeding were compared with the Mann-Whitney U test.The association of risk factors with intracranial bleeding was investigated using univariate analysis with Fisher's exact test or logistic regression. The effects of different variables on cerebral bleeding were analysed by multivariate logistic regression. RESULTS Two hundred and eighty (280) patients with accidents associated with the bathtub or shower were included in our study. Two hundred and thirty-five (235) patients suffered direct trauma by hitting an object (83.9%) and traumatic brain injury (TBI) was detected in 28 patients (10%). Eight (8) of the 27 patients with mild traumatic brain injuries (GCS 13-15), (29.6%) exhibited intracranial haemorrhage. All patients with intracranial haemorrhage were older than 48 years and needed in-hospital treatment. Patients with intracranial haemorrhage were significantly older and had higher haemoglobin levels than the control group with TBI but without intracranial bleeding (p<0.05 for both).In univariate analysis, we found that intracranial haemorrhage in patients with TBI was associated with direct trauma in general and with age (both p<0.05), but not with the mechanism of the fall, its location (shower or bathtub) or the gender of the patient. Multivariate logistic regression analysis identified only age as a risk factor for cerebral bleeding (p<0.05; OR 1.09 (CI 1.01;1.171)). CONCLUSION In patients with ED admissions associated with the bathtub or shower direct trauma and age are risk factors for intracranial haemorrhage. Additional effort in prevention should be considered, especially in the elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient approach for the simulation of ion scattering from solids is proposed. For every encountered atom, we take multiple samples of its thermal displacements among those which result in scattering with high probability to finally reach the detector. As a result, the detector is illuminated by intensive “showers,” where each event of detection must be weighted according to the actual probability of the atom displacement. The computational cost of such simulation is orders of magnitude lower than in the direct approach, and a comprehensive analysis of multiple and plural scattering effects becomes possible. We use this method for two purposes. First, the accuracy of the approximate approaches, developed mainly for ion-beam structural analysis, is verified. Second, the possibility to reproduce a wide class of experimental conditions is used to analyze some basic features of ion-solid collisions: the role of double violent collisions in low-energy ion scattering; the origin of the “surface peak” in scattering from amorphous samples; the low-energy tail in the energy spectra of scattered medium-energy ions due to plural scattering; and the degradation of blocking patterns in two-dimensional angular distributions with increasing depth of scattering. As an example of simulation for ions of MeV energies, we verify the time reversibility for channeling and blocking of 1-MeV protons in a W crystal. The possibilities of analysis that our approach offers may be very useful for various applications, in particular, for structural analysis with atomic resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phase I interim report issued Nov. 1976.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AEC Contract AT(04-3)-400.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate knowledge of the fluorescence yield and its dependence on atmospheric properties such as pressure, temperature or humidity is essential to obtain a reliable measurement of the primary energy of cosmic rays in experiments using the fluorescence technique. In this work, several sets of fluorescence yield data (i.e. absolute value and quenching parameters) are described and compared. A simple procedure to study the effect of the assumed fluorescence yield on the reconstructed shower parameters (energy and shower maximum depth) as a function of the primary features has been developed. As an application, the effect of water vapor and temperature dependence of the collisional cross section on the fluorescence yield and its impact on the reconstruction of primary energy and shower maximum depth has been studied. Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The author's approach to the problems associated with building in bushfire prone landscapes comes from 12 years of study of the biophysical and cultural landscapes in the Great Southern Region of Western Australia - research which resulted in the design and construction of the H-house at Bremer Bay. The house was developed using a 'ground up' approach whereby Dr Weir conducted topographical surveys and worked with a local botanist and a bushfire risk consultant to ascertain the level of threat that fire presented to this particular site. The intention from the outset however, was not to design a bushfire resistant house per se, but to develop a design which would place the owners in close proximity to the highly biodiverse heath vegetation of their site. The research aim was to find ways - through architectural design-to link the patterns of usage of the house with other site specific conditions related to the prevailing winds, solar orientation and seasonal change. The H-house has a number of features which increase the level of bushfire safety. These include: Fire rated roller shutters (tested by the CSIRO for ember attack and radiant heat), Fire resistant double glazing (on windows not protected by the shutters), Fibre-cement sheet cladding of the underside of the elevated timber floor structure, Manually operated high pressure sprinkler system on exposed timber decks, A fire refuge (an enlarged laundry, shower area) within the house with a dedicated cabinet for fire fighting equipment) and A low pressure solar powered domestic water supply system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background/Rationale Guided by the need-driven dementia-compromised behavior (NDB) model, this study examined influences of the physical environment on wandering behavior. Methods Using a descriptive, cross-sectional design, 122 wanderers from 28 long-term care (LTC) facilities were videotaped 10 to 12 times; data on wandering, light, sound, temperature and humidity levels, location, ambiance, and crowding were obtained. Associations between environmental variables and wandering were evaluated with chi-square and t tests; the model was evaluated using logistic regression. Results In all, 80% of wandering occurred in the resident’s own room, dayrooms, hallways, or dining rooms. When observed in other residents’ rooms, hallways, shower/baths, or off-unit locations, wanderers were likely (60%-92% of observations) to wander. The data were a good fit to the model overall (LR [logistic regression] χ2 (5) = 50.38, P < .0001) and by wandering type. Conclusions Location, light, sound, proximity of others, and ambiance are associated with wandering and may serve to inform environmental designs and care practices.