980 resultados para service limit state


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brazilian design code ABNT NBR6118:2003 - Design of Concrete Structures - Procedures - [1] proposes the use of simplified models for the consideration of non-linear material behavior in the evaluation of horizontal displacements in buildings. These models penalize stiffness of columns and beams, representing the effects of concrete cracking and avoiding costly physical non-linear analyses. The objectives of the present paper are to investigate the accuracy and uncertainty of these simplified models, as well as to evaluate the reliabilities of structures designed following ABNT NBR6118:2003[1&] in the service limit state for horizontal displacements. Model error statistics are obtained from 42 representative plane frames. The reliabilities of three typical (4, 8 and 12 floor) buildings are evaluated, using the simplified models and a rigorous, physical and geometrical non-linear analysis. Results show that the 70/70 (column/beam stiffness reduction) model is more accurate and less conservative than the 80/40 model. Results also show that ABNT NBR6118:2003 [1] design criteria for horizontal displacement limit states (masonry damage according to ACI 435.3R-68(1984) [10]) are conservative, and result in reliability indexes which are larger than those recommended in EUROCODE [2] for irreversible service limit states.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La aparición de la fatiga ha sido ampliamente investigada en el acero y en otros materiales metálicos, sin embargo no se conoce en tanta profundidad en el hormigón estructural. Esto crea falta de uniformidad y enfoque en el proceso de verificación de estructuras de hormigón para el estado límite último de la fatiga. A medida que se llevan a cabo más investigaciones, la información sobre los parámetros que afectan a la fatiga en el hormigón comienzan a ser difundidos e incluso los que les afectan de forma indirecta. Esto conlleva a que se estén incorporando en las guías de diseño de todo el mundo, a pesar de que la comprobación del estado límite último no se trata por igual entre los distintos órganos de diseño. Este trabajo presentará un conocimiento básico del fenómeno de la fatiga, qué lo causa y qué condiciones de carga o propiedades materiales amplían o reducen la probabilidad de fallo por fatiga. Cuatro distintos códigos de diseño serán expuestos y su proceso de verificación ha sido examinado, comparados y valorados cualitativa y cuantitativamente. Una torre eólica, como ejemplo, fue analizada usando los procedimientos de verificación como se indica en sus respectivos códigos de referencia. The occurrence of fatigue has been extensively researched in steel and other metallic materials it is however, not as broadly understood in concrete. This produces a lack of uniformity in the approach and process in the verification of concrete structures for the ultimate limit state of fatigue. As more research is conducted and more information is known about the parameters which cause, propagate, and indirectly affect fatigue in concrete, they are incorporated in design guides around the world. Nevertheless, this ultimate limit state verification is not addressed equally by various design governing bodies. This report presents a baseline understanding of what the phenomenon of fatigue is, what causes it, and what loading or material conditions amplify or reduce the likelihood of fatigue failure. Four different design codes are exposed and their verification process has been examined, compared and evaluated both qualitatively and quantitatively. Using a wind turbine tower structure as case study, this report presents calculated results following the verification processes as instructed in the respective reference codes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Report year ends June 30.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actualmente e cada vez mais, são concebidos e utilizados programas de cálculo automático de Engenharia na realização de projectos de edifícios, que proporcionam aos engenheiros uma possibilidade avançada e rápida de execução, simulação e análise de edifícios para estruturas complexas e de elevada dimensão. Contudo, será necessário que os resultados deverão ser fiáveis de modo a não existirem consequências no comportamento real da estrutura a longo prazo. O presente relatório de estágio, refere-se à verificação aos estados limites de utilização (tensões, fendilhação e deformação) segundo o Eurocódigo 2, de uma estrutura porticada em betão armado, nomeadamente de um pórtico central pertencente a essa mesma estrutura recorrendo ao programa de cálculo automático da Autodesk o Robot Structural Analysis Professional 2014. O objectivo principal do presente trabalho consiste na comparação de resultados referente aos estados limites últimos e de utilização, pelos diferentes módulos de dimensionamento Required e Provided Reinforcement presentes no programa Robot. É destacado no final do relatório, considerando uma disposição de armadura optada analiticamente para o pórtico, uma análise comparativa de resultados referente aos estados limites de utilização entre o comando Typical Reinforcement do módulo Provided Reinforcement e por expressões analíticas. Refere-se contudo que, o procedimento do método analítico teve como base de cálculo uma aplicação desenvolvida para a verificação de elementos de betão armado aos estados limites de utilização segundo o Eurocódigo 2, com o nome de XD-Conserv tendo sido também comparado os resultados finais do mesmo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)