856 resultados para serial testing
Resumo:
In Brazil, human and canine visceral leishmaniasis (CVL) caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.
Resumo:
In Brazil, human and canine visceral leishmaniasis (CVL) caused by Leishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.
Resumo:
A cohort of 123 adult contacts was followed for 18‐24 months (86 completed the follow-up) to compare conversion and reversion rates based on two serial measures of QuantiFERON (QFT) and tuberculin skin test (TST) (PPD from TUBERSOL, Aventis Pasteur, Canada) for diagnosing latent tuberculosis (TB) in household contacts of TB patients using conventional (C) and borderline zone (BZ) definitions. Questionnaires were used to obtain information regarding TB exposure, TB risk factors and socio-demographic data. QFT (IU/mL) conversion was defined as <0.35 to ≥0.35 (C) or <0.35 to >0.70 (BZ) and reversion was defined as ≥0.35 to <0.35 (C) or ≥0.35 to <0.20 (BZ); TST (mm) conversion was defined as <5 to ≥5 (C) or <5 to >10 (BZ) and reversion was defined as ≥5 to <5 (C). The QFT conversion and reversion rates were 10.5% and 7% with C and 8.1% and 4.7% with the BZ definitions, respectively. The TST rates were higher compared with QFT, especially with the C definitions (conversion 23.3%, reversion 9.3%). The QFT conversion and reversion rates were higher for TST ≥5; for TST, both rates were lower for QFT <0.35. No risk factors were associated with the probability of converting or reverting. The inconsistency and apparent randomness of serial testing is confusing and adds to the limitations of these tests and definitions to follow-up close TB contacts.
Resumo:
This study aimed to evaluate the interference of tuberculin test on the gamma-interferon (INFg) assay, to estimate the sensitivity and specificity of the INFg assay in Brazilian conditions, and to simulate multiple testing using the comparative tuberculin test and the INFg assay. Three hundred-fifty cattle from two TB-free and two TB-infected herds were submitted to the comparative tuberculin test and the INFg assay. The comparative tuberculin test was performed using avian and bovine PPD. The INFg assay was performed by the BovigamTM kit (CSL Veterinary, Australia), according to the manufacturer's specifications. Sensitivity and specificity of the INFg assay were assessed by a Bayesian latent class model. These diagnostic parameters were also estimate for multiple testing. The results of INFg assay on D0 and D3 after the comparative tuberculin test were compared by the McNemar's test and kappa statistics. Results of mean optical density from INFg assay on both days were similar. Sensitivity and specificity of the INFg assay showed results varying (95% confidence intervals) from 72 to 100% and 74 to 100% respectively. Sensitivity of parallel testing was over 97.5%, while specificity of serial testing was over 99.7%. The INFg assay proved to be a very useful diagnostic method.
Resumo:
OBJECTIVE: The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. METHODS: To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. RESULTS: A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. CONCLUSION: The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
Resumo:
Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.
Resumo:
Purpose. To analyze the diagnostic validity of accommodative and binocular tests in a sample of patients with a large near exophoria with moderate to severe symptoms. Methods. Two groups of patients between 19 and 35 years were recruited from a university clinic: 33 subjects with large exophoria at near vision and moderate or high visual discomfort and 33 patients with normal heterophoria and low visual discomfort. Visual discomfort was defined using the Conlon survey. A refractive exam and an exhaustive evaluation of accommodation and vergence were assessed. Diagnostic validity by means of receiver operator characteristic (ROC) curves, sensitivity (S), specificity (Sp), and positive and negative likelihood ratios (LR+, LR−) were assessed. This analysis was also carried out considering multiple tests as serial testing strategy. Results. ROC analysis showed the best diagnostic accuracy for receded near point of convergence (NPC) recovery (area = 0.929) and binocular accommodative facility (BAF) (area = 0.886). Using the cut-offs obtained with ROC analysis, the best diagnostic validity was obtained for the combination of NPC recovery and BAF (S = 0.77, Sp = 1, LR+ = value tending to infinity, LR− = 0.23) and the combination of NPC break and recovery with BAF (S = 0.73, Sp = 1, LR+ = tending to infinity, LR− = 0.27). Conclusions. NPC and BAF tests were the tests with the best diagnostic accuracy for subjects with large near exophoria and moderate to severe symptoms.
Resumo:
Background: The use of sagittal abdominal diameter (SAD) has been proposed for screening cardio-metabolic risk factors; however, its accuracy can be influenced by the choice of thresholds values. Aim: To determine the SAD threshold values for cardio-metabolic risk factors in Mexican adults; to assess whether parallel and serial SAD testing can improve waist circumference (WC) sensitivity and specificity; and to analyze the effect of considering SAD along with WC and body mass index (BMI) in detecting cardio-metabolic risk. Methods: This cross-sectional study was conducted during 2012-2014 in Northeast Mexico (n = 269). Data on anthropometric, clinical, and biochemical measurements were collected. Sex-adjusted receiver-operating characteristic curves (ROC) were obtained using hypertension, dysglycemia, dyslipidemia and insulin resistance as individual outcomes and metabolic syndrome as a composite outcome. Age-adjusted odds ratios and 95% confidence intervals (CI) were estimated using logistic regression. Results: The threshold value for SAD with acceptable combination of sensitivity and specificity was 24.6 cm in men and 22.5 cm in women. Parallel SAD testing improved WC sensitivity and serial testing improved WC specificity. The co-occurrence of high WC/high SAD increased the risk for insulin resistance by 2.4-fold (95% CI: 1.1-5.3), high BMI/high SAD by 4.3-fold (95% CI: 1.7-11.9) and SAD alone by 2.2-fold (95% CI: 1.2.-4.2). Conclusions: The use of SAD together with traditional obesity indices such as WC and BMI has advantages over using either of these indices alone. SAD may be a powerful screening tool for interventions for high-risk individuals.
Testing for Seasonal Unit Roots when Residuals Contain Serial Correlations under HEGY Test Framework
Resumo:
This paper introduces a corrected test statistic for testing seasonal unit roots when residuals contain serial correlations, based on the HEGY test proposed by Hylleberg,Engle, Granger and Yoo (1990). The serial correlations in the residuals of test regressionare accommodated by making corrections to the commonly used HEGY t statistics. Theasymptotic distributions of the corrected t statistics are free from nuisance parameters.The size and power properties of the corrected statistics for quarterly and montly data are investigated. Based on our simulations, the corrected statistics for monthly data havemore power compared with the commonly used HEGY test statistics, but they also have size distortions when there are strong negative seasonal correlations in the residuals.
Resumo:
Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.
Resumo:
OBJECTIVE: To evaluate the influences of circadian variations on tilt-table testing (TTT) results by comparing the positivity rate of the test performed during the morning with that of the test performed in the afternoon and to evaluate the reproducibility of the results in different periods of the day. METHODS: One hundred twenty-three patients with recurrent unexplained syncope or near-syncope referred for TTT were randomized into 2 groups. In group I, 68 patients, TTT was performed first in the afternoon and then in the morning. In group II, 55 patients, the test was performed first in the morning and then in the afternoon. RESULTS: The TTT protocol was the prolonged passive test, without drug sensitization. Twenty-nine (23.5%) patients had a positive result in at least one of the periods. The positivity rate for each period was similar: 20 (16.2%) patients in the afternoon and 19 (15.4%) in the morning (p=1.000). Total reproducibility (positive/positive and negative/negative) was observed in 49 (89%) patients in group I and in 55 (81%) in group II. Reproducibility of the results was obtained in 94 (90.4%) patients with first negative tests but in 10 (34%) patients with first positive tests. CONCLUSION: TTT could be performed during any period of the day, and even in the 2 periods to enhance positivity. Considering the low reproducibility rate of the positive tests, serial TTT to evaluate therapeutic efficacy should be performed during the same period of the day.
Resumo:
Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h), 2 (TnT2h), 5 (TnT5h), and 8 hours (TnT8h) after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h). After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.
Resumo:
T-cell vaccination may prevent or treat cancer and infectious diseases, but further progress is required to increase clinical efficacy. Step-by-step improvements of T-cell vaccination in phase I/II clinical studies combined with very detailed analysis of T-cell responses at the single cell level are the strategy of choice for the identification of the most promising vaccine candidates for testing in subsequent large-scale phase III clinical trials. Major aims are to fully identify the most efficient T-cells in anticancer therapy, to characterize their TCRs, and to pinpoint the mechanisms of T-cell recruitment and function in well-defined clinical situations. Here we discuss novel strategies for the assessment of human T-cell responses, revealing in part unprecedented insight into T-cell biology and novel structural principles that govern TCR-pMHC recognition. Together, the described approaches advance our knowledge of T-cell mediated-protection from human diseases.
Resumo:
Objective: Aspergillus species are the main pathogens causing invasive fungal infections but the prevalence of other mould species is rising. Resistance to antifungals among these new emerging pathogens presents a challenge for managing of infections. Conventional susceptibility testing of non-Aspergillus species is laborious and often difficult to interpret. We evaluated a new method for real-time susceptibility testing of moulds based on their of growth-related heat production.Methods: Laboratory and clinical strains of Mucor spp. (n = 4), Scedoporium spp. (n = 4) and Fusarium spp. (n = 5) were used. Conventional MIC was determined by microbroth dilution. Isothermal microcalorimetry was performed at 37 C using Sabouraud dextrose broth (SDB) inoculated with 104 spores/ml (determined by microscopical enumeration). SDB without antifungals was used for evaluation of growth characteristics. Detection time was defined as heat flow exceeding 10 lW. For susceptibility testing serial dilutions of amphotericin B, voriconazole, posaconazole and caspofungin were used. The minimal heat inhibitory concentration (MHIC) was defined as the lowest antifungal concentration, inhbiting 50% of the heat produced by the growth control at 48 h or at 24 h for Mucor spp. Susceptibility tests were performed in duplicate.Results: Tested mould genera had distinctive heat flow profiles with a median detection time (range) of 3.4 h (1.9-4.1 h) for Mucor spp, 11.0 h (7.1-13.7 h) for Fusarium spp and 29.3 h (27.4-33.0 h) for Scedosporium spp. Graph shows heat flow (in duplicate) of one representative strain from each genus (dashed line marks detection limit). Species belonging to the same genus showed similar heat production profiles. Table shows MHIC and MIC ranges for tested moulds and antifungals.Conclusions: Microcalorimetry allowed rapid detection of growth of slow-growing species, such as Fusarium spp. and Scedosporium spp. Moreover, microcalorimetry offers a new approach for antifungal susceptibility testing of moulds, correlating with conventional MIC values. Interpretation of calorimetric susceptibility data is easy and real-time data on the effect of different antifungals on the growth of the moulds is additionally obtained. This method may be used for investigation of different mechanisms of action of antifungals, new substances and drug-drug combinations.
Resumo:
In the first part of the study, nine estimators of the first-order autoregressive parameter are reviewed and a new estimator is proposed. The relationships and discrepancies between the estimators are discussed in order to achieve a clear differentiation. In the second part of the study, the precision in the estimation of autocorrelation is studied. The performance of the ten lag-one autocorrelation estimators is compared in terms of Mean Square Error (combining bias and variance) using data series generated by Monte Carlo simulation. The results show that there is not a single optimal estimator for all conditions, suggesting that the estimator ought to be chosen according to sample size and to the information available of the possible direction of the serial dependence. Additionally, the probability of labelling an actually existing autocorrelation as statistically significant is explored using Monte Carlo sampling. The power estimates obtained are quite similar among the tests associated with the different estimators. These estimates evidence the small probability of detecting autocorrelation in series with less than 20 measurement times.