1000 resultados para sealing quality
Resumo:
The aim of this study was to evaluate the apical sealing of dentinal tubules after root-end surface cutting by using Er:YAG and Nd:YAG lasers. After root-canal instrumentation and filling, apices of 50 extracted maxillary canine human teeth were resected by Er: YAG with 400 mJ, 10 Hz, for 30 sec. The samples were randomly assigned to five groups (n = 10): (GI) treated without root-end cavity, but with Nd: YAG (1.0W, 10 Hz, 20 sec) for dentinal tubules sealing; (GII) treated with root-end cavity without the use of Nd: YAG; (GIII) treated with root-end cavity and Nd: YAG application; (GIV) treated with root-end cavity made by Er: YAG with no focus and without Nd: YAG application; and (GV) treated without root-end cavity and without Nd: YAG application. The root-end cavities were performed by using Er: YAG at 300 mJ, 10 Hz, for 20 sec. Subsequently, all teeth were waterproofed and immersed in 2% methylene blue for 48 h in a vacuum environment. The samples were longitudinally sectioned, and microleakage was measured. ANOVA and the Fisher LSD test showed that GIV was less susceptible to microleakage than were the other groups (p < 0.05). Interestingly, the use of the Er: YAG with no focus showed superior dentinal tubule sealing in comparison with the other groups, even with or without root-end cavity and Nd: YAG application.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study was an in vitro analysis of the apical seal of root canals filled with an experimental calcium hydroxide gutta-percha point. One hundred and ten recently extracted human permanent teeth with a single root were used. The root canals were biomechanically prepared, and some received a dressing of calcium hydroxide for 7 days. Root canals not dressed were filled by the lateral condensation technique with either regular gutta-percha or calcium hydroxide gutta-percha points. The dressed root canals were filled with the same sealers and regular gutta-percha points. The specimens were placed into a 2% methylene blue dye solution under vacuum, and the apical leakage was linearly evaluated. The experimental groups with calcium hydroxide dressing and the one with calcium hydroxide gutta-percha points exhibited significantly (p < 0.05) less leakage than the groups filled with regular gutta-percha points. The results obtained indicated that calcium hydroxide guttapercha points produced an improvement in the apical sealing quality of the root canal filling. Copyright © 1996 by The American Association of Endodontists.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Three-dimensional (3D) forming of paperboard and heat sealing of lidding films to trays manufactured by the press forming process are investigated in this thesis. The aim of the work was to investigate and recognize the factors affecting the quality of heat sealing and the leak resistance (tightness) of press-formed, polymer-coated paperboard trays heatsealed with a multi-layer polymer based lidding film. One target was to achieve a solution that can be used in food packaging using modified atmosphere packaging (MAP). The main challenge in acquiring adequate tightness properties for the use of MAP is creases in the sealing area of the paperboard trays which can act as capillary tubes and prevent leak-proof sealing. Several experiments were made to investigate the effect of different factors and process parameters in the forming and sealing processes. Also different methods of analysis, such as microscopic analysis and 3D-profilometry were used to investigate the structure of the creases in the sealing area, and to analyse the surface characteristics of the tray flange of the formed trays to define quality that can be sealed with satisfactory tightness for the use of MAP. The main factors and parameters that had an effect on the result of leak-proof sealing and must be adjusted accordingly were the tray geometry and dimensions, blank holding force in press forming, surface roughness of the sealing area, the geometry and depth of the creases, and the sealing pressure. The results show that the quality of press-formed, polymer-coated paperboard trays and multi-layer polymer lidding films can be satisfactory for the use of modified atmosphere packaging in food solutions. Suitable tools, materials, and process parameters have to be selected and used during the tray manufacturing process and lid sealing process, however. Utilizing these solutions and results makes it possible for a package that is made mostly from renewable and recyclable sources to be a considerable alternative for packages made completely from oil based polymers, and to achieve a greater market share for fibre-based solutions in food packaging using MAP.
Resumo:
This study sought to evaluate the association between the impact of oral disorders in terms of physical/psychosocial dimensions and quality of life among the elderly. It involved a cross-sectional study conducted among the elderly (65-74 years) in 2008/2009. The social impact was assessed using the Oral Health Impact Profile (OHIP 14) and the quality of life using the SF 12 Short-Form Health Survey. Descriptive, univariate and multivariate (logistic regression) analysis was conducted with correction for the design effect, using SPSS(r)18.0 software. Of the 800 individuals approached, 736 elderly individuals participated (TR = 92%), with a mean age of 67.77 years, the majority of whom showed no impact based on the measurement of the prevalence of OHIP. The functional limitation dimension of the OHIP was associated with the physical domain of the SF12, irrespective of the other variables investigated. However, the seriousness of OHIP and its psychological discomfort and disability dimensions was associated with the mental domain of the SF12. The conclusion reached is that some impacts of oral disorders were associated with unsatisfactory quality of life in the physical and mental domains.
Resumo:
To assess quality of care of women with severe maternal morbidity and to identify associated factors. This is a national multicenter cross-sectional study performing surveillance for severe maternal morbidity, using the World Health Organization criteria. The expected number of maternal deaths was calculated with the maternal severity index (MSI) based on the severity of complication, and the standardized mortality ratio (SMR) for each center was estimated. Analyses on the adequacy of care were performed. 17 hospitals were classified as providing adequate and 10 as nonadequate care. Besides almost twofold increase in maternal mortality ratio, the main factors associated with nonadequate performance were geographic difficulty in accessing health services (P < 0.001), delays related to quality of medical care (P = 0.012), absence of blood derivatives (P = 0.013), difficulties of communication between health services (P = 0.004), and any delay during the whole process (P = 0.039). This is an example of how evaluation of the performance of health services is possible, using a benchmarking tool specific to Obstetrics. In this study the MSI was a useful tool for identifying differences in maternal mortality ratios and factors associated with nonadequate performance of care.
Resumo:
The aim of this study was to assess the quality of diet among the elderly and associations with socio-demographic variables, health-related behaviors, and diseases. A population-based cross-sectional study was conducted in a representative sample of 1,509 elderly participants in a health survey in Campinas, São Paulo State, Brazil. Food quality was assessed using the Revised Diet Quality Index (DQI-R). Mean index scores were estimated and a multiple regression model was employed for the adjusted analyses. The highest diet quality scores were associated with age 80 years or older, Evangelical religion, diabetes mellitus, and physical activity, while the lowest scores were associated with home environments shared with three or more people, smoking, and consumption of soft drinks and alcoholic beverages. The findings emphasize a general need for diet quality improvements in the elderly, specifically in subgroups with unhealthy behaviors, who should be targeted with comprehensive strategies.
Resumo:
Patients with myofascial pain experience impaired mastication, which might also interfere with their sleep quality. The purpose of this study was to evaluate the jaw motion and sleep quality of patients with myofascial pain and the impact of a stabilization device therapy on both parameters. Fifty women diagnosed with myofascial pain by the Research Diagnostic Criteria were enrolled. Pain levels (visual analog scale), jaw movements (kinesiography), and sleep quality (Epworth Sleepiness Scale; Pittsburgh Sleep Quality Index) were evaluated before (control) and after stabilization device use. Range of motion (maximum opening, right and left excursions, and protrusion) and masticatory movements during Optosil mastication (opening, closing, and total cycle time; opening and closing angles; and maximum velocity) also were evaluated. Repeated-measures analysis of variance in a generalized linear mixed models procedure was used for statistical analysis (α=.05). At baseline, participants with myofascial pain showed a reduced range of jaw motion and poorer sleep quality. Treatment with a stabilization device reduced pain (P<.001) and increased both mouth opening (P<.001) and anteroposterior movement (P=.01). Also, after treatment, the maximum opening (P<.001) and closing (P=.04) velocities during mastication increased, and improvements in sleep scores for the Pittsburgh Sleep Quality Index (P<.001) and Epworth Sleepiness Scale (P=.04) were found. Myofascial pain impairs jaw motion and quality of sleep; the reduction of pain after the use of a stabilization device improves the range of motion and sleep parameters.
Resumo:
Treatments for patients with laryngeal cancer often have an impact on physical, social, and psychological functions. To evaluate quality of life and voice in patients treated for advanced laryngeal cancer through surgery or exclusive chemoradiation. Retrospective cohort study with 30 patients free from disease: ten total laryngectomy patients without production of esophageal speech (ES); ten total laryngectomy patients with tracheoesophageal speech (TES), and ten with laryngeal speech. Quality of life was measured by SF-36, Voice-Related Quality of Life (V-RQOL), and Voice Handicap Index (VHI) protocols, applied on the same day. The SF-36 showed that patients who received exclusive chemoradiotherapy had better quality of life than the TES and ES groups. The V-RQOL showed that the voice-related quality of life was lower in the ES group. In the VHI, the ES group showed higher scores for overall, emotional, functional, and organic VHI. Quality of life and voice in patients treated with chemoradiotherapy was better than in patients treated surgically. The type of medical treatment used in patients with laryngeal cancer can bring changes in quality of life and voice.
Resumo:
Pain is a common complaint in women with endometriosis and can be influenced by many variables, including sleep disorders; however, no data are available on the sleep quality of women with endometriosis or on the correlation between sleep quality and pain. The 510 volunteers included in this study were divided into two groups: 257 women with a laparoscopic and histopathological diagnosis of endometriosis and 253 women with no history of endometriosis and no endometriosis-related symptoms. The volunteers answered two questionnaires: the Post-Sleep Inventory to evaluate sleep quality and the International Physical Activity Questionnaire to assess their level of physical activity. Pain was evaluated using a visual analogue scale (VAS) and women were also submitted to a physical examination, during which their pain threshold was assessed at 20 different body sites. Sleep quality was significantly poorer in women with endometriosis compared to women without the disease. The pain threshold was significantly lower in the greater trochanter and abdomen in women with endometriosis when compared to women without the disease; however, there was no difference in VAS pain score between the groups. The higher the VAS pain score, the lower the Post-Sleep Inventory score. Additionally, there was a significant positive correlation between the pain threshold at some body sites and sleep quality. Sleep quality was poorer and the pain threshold at certain body sites was lower in the group of women with endometriosis.
Resumo:
A randomized controlled trial study was performed to evaluate the efficacy of transcutaneous tibial nerve stimulation (TTNS) and sham TTNS, in patients with Parkinson disease (PD) with lower urinary tract symptoms (LUTS). Randomized controlled trial. Thirteen patients with a diagnosis of PD and bothersome LUTS were randomly allocated to one of the following groups: Group I: TTNS group (n = 8) and group II: Sham group (n = 5). Both groups attended twice a week during 5 weeks; each session lasted 30 minutes. Eight patients received TTNS treatment and 5 subjects allocated to group II were managed with sham surface electrodes that delivered no electrical stimulation. Assessments were performed before and after the treatment; they included a 3-day bladder diary, Overactive Bladder Questionnaire (OAB-V8), and the International Consultation on Incontinence Quality of Life Questionnaire Short Form (ICIQ-SF), and urodynamic evaluation. Following 5 weeks of treatment, patients allocated to TTNS demonstrated statistically significant reductions in the number of urgency episodes (P = .004) and reductions in nocturia episodes (P < .01). Participants allocated to active treatment also showed better results after treatment in the OAB-V8 and ICIQ-SF scores (P < .01, respectively). Urodynamic testing revealed that patients in the active treatment group showed improvements in intravesical volume at strong desire to void (P < .05) and volume at urgency (P < .01) when compared to subjects in the sham treatment group. These findings suggest that TTNS is effective in the treatment of LUTS in patients with PD, reducing urgency and nocturia episodes and improving urodynamic parameters as well as symptom scores measured by the OAB-V8 and health-related quality-of-life scores measured by the ICIQ-SF.
Resumo:
This study aims to evaluate the frequency and severity of nausea and vomiting using two different instruments and relate them to quality of life (QOL) in patients with cancer receiving antineoplastic treatment. Severity of chemotherapy-induced nausea and vomiting (CINV) was measured by Common Terminology Criteria for Adverse Events (CTCAE) and a numerical scale. QOL was assessed using the Functional Assessment of Cancer Therapy-General questionnaire. Of the 50 patients studied, 60.0% reported nausea (40.0% CTCAE grade 1; 66.7% moderate intensity on numerical scale) and 30.0% reported vomiting (46.7% CTCAE grades 1 and 2, each; 66.7% moderate intensity on numerical scale). CINV did not influence overall QOL. The frequency of CINV was high. There was no association between nausea/vomiting and overall QOL.
Resumo:
one hundred (n=100) elderly outpatients with diabetic retinopathy taking antihypertensives and/or oral antidiabetics/insulin were interviewed. Adherence was evaluated by the adherence proportion and its association with the care taken in administrating medications and by the Morisky Scale. The National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25) was used to evaluate HRQoL. most (58%) reported the use of 80% or more of the prescribed dose and care in utilizing the medication. The item stopping the drug when experiencing an adverse event, from the Morisky Scale, explained 12.8% and 13.5% of the variability of adherence proportion to antihypertensives and oral antidiabetics/insulin, respectively. there was better HRQoL in the Color Vision, Driving and Social Functioning domains of the NEI VFQ-25. Individuals with lower scores on the NEI VFQ-25 and higher scores on the Morisky Scale presented greater chance to be nonadherent to the pharmacological treatment of diabetes and hypertension.
Resumo:
We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.