1000 resultados para scintigraphic test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the best examinations used routinely to detect gastro-oesophageal reflux (GOR) is scintigraphy and attempts are continuously being made to improve the performance of the test. We have tested a new manoeuvre to improve the results. Three hundred and twenty eight patients (190 males and 138 females, aged 1 month to 84 years, average 4.47 years) were studied after a 12 h fast period with 100 MBq of Tc-99(m)-Phytate, 50 ml volume, directly delivered into the stomach in a mixture of orange juice. All patients were strongly suspected of having GOR. Conventional acquisition was done for 20 min, at a rate of one frame every 20 s. in the middle of the examination, small children were put in the upright position and held there for a few seconds or released in a way that allowed movement; adults were asked to stand up and walk a few metres. The test was then continued for the remaining 10 min. The global index of positivity was 64.6% (76 positive cases in the first half of the examination and 134 positive cases only after the manoeuvre). The mean of GOR episodes observed in the positive cases without the manoeuvre was 0.5 per patient, significantly different from the mean of 1.59 noted after the manoeuvre (P<0.01). In 28 cases the manoeuvre increased either the intensity or the frequency of reflux previously detected without it. We believe that this manoeuvre should be performed in all scintigraphic tests aiming to detect GOR. In the present series, the manoeuvre increased the frequency of GOR episodes. ((C) 2001 Lippincott Williams & Wilkins)].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a range test, one party holds a ciphertext and needs to test whether the message encrypted in the ciphertext is within a certain interval range. In this paper, a range test protocol is proposed, where the party holding the ciphertext asks another party holding the private key of the encryption algorithm to help him. These two parties run the protocol to implement the test. The test returns TRUE if and only if the encrypted message is within the certain interval range. If the two parties do not conspire, no information about the encrypted message is revealed from the test except what can be deduced from the test result. Advantages of the new protocol over the existing related techniques are that it achieves correctness, soundness, °exibility, high e±ciency and privacy simultaneously.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The release of ultrafine particles (UFP) from laser printers and office equipment was analyzed using a particle counter (FMPS; Fast Mobility Particle Sizer) with a high time resolution, as well as the appropriate mathematical models. Measurements were carried out in a 1 m³ chamber, a 24 m³ chamber and an office. The time-dependent emission rates were calculated for these environments using a deconvolution model, after which the total amount of emitted particles was calculated. The total amounts of released particles were found to be independent of the environmental parameters and therefore, in principle, they were appropriate for the comparison of different printers. On the basis of the time-dependent emission rates, “initial burst” emitters and constant emitters could also be distinguished. In the case of an “initial burst” emitter, the comparison to other devices is generally affected by strong variations between individual measurements. When conducting exposure assessments for UFP in an office, the spatial distribution of the particles also had to be considered. In this work, the spatial distribution was predicted on a case by case basis, using CFD simulation.