925 resultados para salicylate and acetylsalicylic acid determination


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the construction of an electrode of the second kind, Pt\Hg\Hg-2(Salic)(2)\Graphite, sensitive to salicylate. This electrode responds to the salicylate ion with a sensivity of 58.66 mV/decade over the range 6.0x10(-4) - 1.0x10(-1) mol/l at pH 6.0 and an ionic strength of 0.500 - 3.00 mol/l, adjusted with NaClO4. The electrode is easily constructed, shows a fast response time, is low in cost, has excellent response stability, and has a lifetime greater than 18 months, which is much longer than those reported earlier for other systems. The influence of 10 different carboxylate and inorganic anions on the electrode response showed that there was negligible interference by most of these ions. It was used to determine aspirin in tablets (after hydrolysis of acetylsalicylic acid to salicylate) by means of the standard additions method. The results obtained using this electrode for aspirin determination, in three different samples of antithermic drugs, compared favorably with the results given by the British Pharmacopoeia method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Dual antiplatelet therapy with clopidogrel plus acetylsalicylic acid (ASA) is superior to ASA alone in patients with acute coronary syndromes and in those undergoing percutaneous coronary intervention. We sought to determine whether clopidogrel plus ASA conferred benefit on limb outcomes over ASA alone in patients undergoing below-knee bypass grafting. METHODS: Patients undergoing unilateral, below-knee bypass graft for atherosclerotic peripheral arterial disease (PAD) were enrolled 2 to 4 days after surgery and were randomly assigned to clopidogrel 75 mg/day plus ASA 75 to 100 mg/day or placebo plus ASA 75 to 100 mg/day for 6 to 24 months. The primary efficacy endpoint was a composite of index-graft occlusion or revascularization, above-ankle amputation of the affected limb, or death. The primary safety endpoint was severe bleeding (Global Utilization of Streptokinase and Tissue plasminogen activator for Occluded coronary arteries [GUSTO] classification). RESULTS: In the overall population, the primary endpoint occurred in 149 of 425 patients in the clopidogrel group vs 151 of 426 patients in the placebo (plus ASA) group (hazard ratio [HR], 0.98; 95% confidence interval [CI], 0.78-1.23). In a prespecified subgroup analysis, the primary endpoint was significantly reduced by clopidogrel in prosthetic graft patients (HR, 0.65; 95% CI, 0.45-0.95; P = .025) but not in venous graft patients (HR, 1.25; 95% CI, 0.94-1.67, not significant [NS]). A significant statistical interaction between treatment effect and graft type was observed (P(interaction) = .008). Although total bleeds were more frequent with clopidogrel, there was no significant difference between the rates of severe bleeding in the clopidogrel and placebo (plus ASA) groups (2.1% vs 1.2%). CONCLUSION: The combination of clopidogrel plus ASA did not improve limb or systemic outcomes in the overall population of PAD patients requiring below-knee bypass grafting. Subgroup analysis suggests that clopidogrel plus ASA confers benefit in patients receiving prosthetic grafts without significantly increasing major bleeding risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNT-N) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 × 10−6 to 1.1 × 10−3 mol dm−3, 1.0 × 10−6 to 1.0 × 10−3 mol dm−3 and 2.0 × 10−6 to 1.0 × 10−4 mol dm−3 with detection limit (S/N = 3) of 0.83 × 10−6, 0.83 × 10−6 and 1.8 × 10−6 mol dm−3, respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive spectrophotometric method is proposed for the simultaneous determination of protocatechuic acid and protocatechuic aldehyde. The method is based on the difference in the kinetic rates of the reactions of analytes with [Ag(NH3)2]+ in the presence of polyvinylpyrrolidone to produce silver nanoparticles. The data obtained were processed by chemometric methods using principal component analysis artificial neural network and partial least squares. Excellent linearity was obtained in the concentration ranges of 1.23-58.56 µg mL-1 and 0.08-30.39 µg mL-1 for PAC and PAH, respectively. The limits of detection for PAC and PAH were 0.039 and 0.025 µg mL-1, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plants can respond to damage by pests with both induced direct defences and indirect defences by the attraction of their natural enemies. Foliar application of several plant-derived chemicals, such as salicylic acid and oxalic acid, can induce these defence mechanisms. The effect of acetylsalicylic acid and oxalic acid on the aphid Myzus persicae Sulzer (Homoptera: Aphididae) and its parasitoid Aphidius colemani Viereck (Hymenoptera: Aphidiidae) was investigated. Experiments were carried out with direct application of acetylsalicylic and oxalic acids on these insects, as well as choice and no-choice tests using foliar application of both chemicals on Brussels sprouts plants, Brassica oleracea var. gemmifera L. (Brassicaceae). Parasitoids were given a choice between treated and untreated plants for oviposition, and the effects of the chemicals on aphid and parasitoid development were determined. Although direct application of both chemicals increased aphid mortality, their foliar application did not induce resistance against aphids. The foliar application of such compounds, even in low concentration as shown in the choice tests, has the potential to induce indirect plant defences against aphids by encouraging aphid parasitisation. Although the direct application of both chemicals reduced parasitoid emergence from their hosts, the foliar application of acetylsalicylic acid and low concentrations of oxalic acid did not have a negative effect on parasitoid emergence ability. However, 10 mm oxalic acid reduced the number of emerged parasitoids in no-choice experiments. This study shows that foliar application of acetylsalicylic and oxalic acids has the potential to encourage aphid parasitisation, but care is needed as high concentrations of oxalic acid can have a negative effect on these beneficial organisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid, and low-cost coulometric method for direct detection of glyphosate and aminomethylphosphonic acid (AMPA) in water samples using anion-exchange chromatography and coulometric detection with copper electrode is presented. Under optimized conditions, the limits of detection (LODs) (S/N = 3) were 0.038 mu g ml(-1) for glyphosate and 0.24 mu g ml(-1) for AMPA, without any preconcentration method. The calibration curves were linear and presented an excellent correlation coefficient. The method was successfully applied to the determination of glyphosate and AMPA in water samples without any kind of extraction, clean-up, or preconcentration step. No interferent was found in the water, like this, the recovery was, practically, 100%. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A reversed phase liquid chromatographic method was developed for the simultaneous determination of carboxylic acids and phenolics in white wines. The samples, diluted, were injected onto a Spherisorb ODS-2 column with a gradient of sulfuric acid (pH 2.5)/methanol as mobile phase. A diode array detector was used which was set at 210nm for carboxylic acids and altered to 278nm, during the run, far phenolics and sorbic acid. The identification of compounds was based on retention time, co-chromatography and UV spectrum. Some clean-up methods (sep-pak C-18 and an ion exchange column) mere tested and did not improve the results.The analysis was simple, with no sample preparation. Application of this method was illustrated by analyses of Brazilian Welchriesling wines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Analisar os efeitos das soluções de aspirina e de ácido acético, in vivo, em fígado de coelhos portadores de tumor hepático VX2, verificando o efeito histolítico e anatomo-patológico das soluções e eventuais alterações bioquímicas hepáticas. MÉTODOS: Utilizou-se 48 coelhos, divididos em 2 protocolos experimentais(3 e 4), subdivididos em 3 grupos cada. Após 4 dias da implantação do tumor no fígado, procedeu-se a laparotomia mediana, com injeção de 0,4 ml da solução de aspirina (5,0%), de ácido acético (5,0%) e solução salina; o sacrifício ocorreu apos 24 horas (protocolo 3) e 11 dias (protocolo 4); avaliou-se o peso, evolução clinica, dosagens bioquímicas, cavidade abdominal e torácica e microscopia do fígado. RESULTADOS: Não foram observadas alterações na evolução clinica, peso e nas dosagens bioquímicas, apenas elevação da fosfatase alcalina no grupo controle do protocolo 4. Observamos desaparecimento do tumor em ambos os protocolos. CONCLUSÃO: As soluções de ácido acético e ácido acetilsalicílico acarretam destruição do tumor hepático experimental.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To analyze, in vitro, the effects of acetylsalicylic acid (aspirin) and acetic acid solutions on VX2 carcinoma cells in suspension and to examine the correlation between these effects and neoplastic cell death. Methods: The VX2 tumor cells (107 cells/ml) were incubated in solutions containing differing concentrations (2.5% and 5%) of either acetylsalicylic acid or acetic acid, or in saline solution (controls). Every five minutes, cell viability was tested (using the trypan blue test) and analyzed under light microscopy. Results: Tumor cell viability (in %) decreased progressively and, by 30 minutes, neoplastic cell death had occurred in all solutions. Conclusion: Based on this experimental model and the methodology employed, we conclude that these solutions cause neoplastic cell death in vitro.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate the influence of a regular oral use of acetylsalicylic acid in the prevalence of actinic keratosis.Methods: A case-control study with dermatologic outpatients above 50 years of age assessed between 2009 and 2011. Cases were defined as those who had been under regular use of oral acetylsalicylic acid for more than six consecutive months. The assessment focused on: age, sex, skin-type, tobacco smoking, use of medication, occurrence of individual or family skin cancer, and sunscreen and sun exposure habits. Actinic keratoses were counted in the medial region of the face and upper limbs. Counts were adjusted by co-variables based on a generalized linear model.Results: A total of 74 cases and 216 controls were assessed. The median time of acetylsalicylic acid use was 36 months. Cases differed from controls as to the highest age, highest prevalence of use of angiotensin-converting enzyme inhibitors and fewer keratosis on the face and on the upper limbs (p < 0.05). The multivariate model showed that the use of acetylsalicylic acid was associated to lower counts of face actinic keratosis and upper-limb erythematous actinic keratosis (p < 0.05), regardless of other risk factors.Conclusion: The regular use of oral acetylsalicylic acid for more than six months was associated to a lower prevalence of actinic keratosis, especially facial and erythematous ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impaired response to antiplatelet therapy with acetylsalicylic acid (ASA) and clopidogrel (CLO) has been associated with an increased risk of stent thrombosis and ischemic events after coronary stent implantation. We sought to investigate whether patients with a low response (LR) to ASA or CLO are at increased risk for periprocedural and short-term ischemic events after coronary stent implantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A convenient and rapid method for the simultaneous determination by HPLC of 3-hydroxyanthranilic acid and the dimer derived by its oxidation, cinnabarinic acid, is described. Buffers or biological samples containing these two Trp metabolites were acidified to pH 2.0 and extracted with ethyl acetate with recoveries of 96.5 +/- 0.5 and 93.4 +/- 3.7% for 3-hydroxyanthranilic and cinnabarinic acid, respectively. The two compounds were separated on a reversed-phase (C18) column combined with ion-pair chromatography and detected photometrically or electrochemically. The method was applied successfully to biological systems in which formation of either 3-hydroxyanthranilic or cinnabarinic acid had been described previously. Thus, interferon-gamma-treated human peripheral blood mononuclear cells formed and released significant amounts of 3-hydroxyanthranilic acid into the culture medium and mouse liver nuclear fraction possessed high "cinnabarinic acid synthase" activity. In contrast, addition of 3-hydroxyanthranilic acid to human erythrocytes resulted in only marginal formation of cinnabarinic acid. We conclude that the method described is specific, sensitive, and suitable for the detection of the two Trp metabolites in biological systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The stomach is thought to be protected from luminal acid by a gastric mucosal barrier that restricts the diffusion of acid into tissue. This study tested the hypothesis that the hydrophobic luminal surface of canine gastric mucosa incubated in Ussing chambers, impedes the back-diffusion of luminal acid into the tissue. Isolated sheets of mucosa were treated with cimetidine to inhibit spontaneous acid secretion, and incubated under conditions that prevented significant secretion of luminal bicarbonate. By measuring acid loss from the luminal compartment using the pH-stat technique, acid back-diffusion was continuously monitored; potential difference (PD) was measured as an index of tissue viability. Tissue luminal surface hydrophobicity was estimated by contact angle analysis at the end of each experiment. Addition of 16,16-dimethyl prostaglandin E$\sb2$ to the nutrient compartment enhanced luminal surface hydrophobicity, but did not reduce acid back-diffusion in tissues that maintained a constant PD. 10 mM salicylate at pH 4.00 in the luminal compartment reduced surface hydrophobicity, but this decrease did not occur if 1 ug/ml prostaglandin was present in the nutrient solution. Despite possessing relatively hydrophilic and relatively hydrophobic surface properties, respectively, acid back-diffusion in the absence of salicylate was not significantly different between these two groups. Neither group maintained a PD after incubation with salicylate. Lastly, radiolabelled salicylate was used to calculate the free (non-salicylate associated) acid loss in tissues incubated with salicylate and/or prostaglandin. No significant correlation was found between free acid back-diffusion and luminal surface hydrophobicity. These data do not support the hypothesis that acid back-diffusion in impeded by the hydrophobic surface presented by isolated canine gastric mucosa. ^