985 resultados para safety issue
Resumo:
Mode of access: Internet.
Resumo:
This project included a literature review and summary that focused on subjects related to team building, team/committee member motivational strategies, and tools for effective and efficient committee meetings. It also completed an online survey of multidisciplinary safety team (MDST) members that focused on methods to increase meeting attendance and the identification of factors that make MDSTs successful. The survey had a response rate of about 15 percent. Finally, three small MDST focus groups were held and the participants discussed information similar to that investigated by the online survey. The results of these three activities were similar and complementary. In general, the outcomes of all three tasks show that a well-designed agenda that has items relevant to the meeting attendees is very important. In addition, the literature, online survey, and focus group results identified other characteristics that define a good team or MDST. Some of these characteristics included effective and consistent leadership, members that are allowed to provide input and have an impact, members that are vested in the activities of the group, and a match between the interests of the members and the focus/mission/purpose of the meetings/group. Meetings that are scheduled well in advance of the meeting date, include time for networking, local safety activity discussions, hands-on activities/tasks, and/or some type of educational or informational presentation or activity also appeared to be the most desirable. Lastly, it was shown that MDSTs can thrive and be successful through various means, but the ability to focus on a specific safety issue when the group is first organized was suggested as a benefit that could be of assistance for long-term sustainability.
Resumo:
This issue review provides information about the Iowa State Patrol's general fund budget; specifically, vehicle depreciation and fuel expenses.
Resumo:
The federal government mandated that all non-federal public safety license holders on the frequencies ranging from 150 to 512 megahertz reduce their operating bandwidth from 25 kilohertz to 12.5 kilohertz. Narrowband channels must update their operating licenses by January 1, 2013. Failure to do so will result in the loss of communication capabilities and fines. This issue review analyzes the impact to state agencies of the federal mandate requiring all two-way radio systems and some paging networks, including those used by public-safety agencies, to meet the new narrowband requirements by January 1, 2013. This issue review does not address the impact to local communications systems.
Resumo:
This issue review examines the prison system fiscal year 2010 budget, including receipts and expenditures, average annual costs, personnel and inmate assaults.
Resumo:
This issue review provides information regarding the implementation of the centralized pharmacy within the Department of Corrections, or DOC.
Resumo:
This issue review examines the funding levels within the community-based corrections, or CBC, district departments compared to the offender populations, risk and supervision levels, and recidivism rates to consider whether current funding allocations are appropriate. The majority of offenders in corrections are supervised by the CBC-district departments.
Resumo:
OBJECTIVES To explore the experiences of oncology staff with communicating safety concerns and to examine situational factors and motivations surrounding the decision whether and how to speak up using semistructured interviews. SETTING 7 oncology departments of six hospitals in Switzerland. PARTICIPANTS Diverse sample of 32 experienced oncology healthcare professionals. RESULTS Nurses and doctors commonly experience situations which raise their concerns and require questioning, clarifying and correcting. Participants often used non-verbal communication to signal safety concerns. Speaking-up behaviour was strongly related to a clinical safety issue. Most episodes of 'silence' were connected to hygiene, isolation and invasive procedures. In contrast, there seemed to exist a strong culture to communicate questions, doubts and concerns relating to medication. Nearly all interviewees were concerned with 'how' to say it and in particular those of lower hierarchical status reflected on deliberate 'voicing tactics'. CONCLUSIONS Our results indicate a widely accepted culture to discuss any concerns relating to medication safety while other issues are more difficult to voice. Clinicians devote considerable efforts to evaluate the situation and sensitively decide whether and how to speak up. Our results can serve as a starting point to develop a shared understanding of risks and appropriate communication of safety concerns among staff in oncology.
Resumo:
NanoImpactNet (NIN) is a multidisciplinary European Commission funded network on the environmental, health and safety (EHS) impact of nanomaterials. The 24 founding scientific institutes are leading European research groups active in the fields of nanosafety, nanorisk assessment and nanotoxicology. This 4-year project is the new focal point for information exchange within the research community. Contact with other stakeholders is vital and their needs are being surveyed. NIN is communicating with 100s of stakeholders: businesses; internet platforms; industry associations; regulators; policy makers; national ministries; international agencies; standard-setting bodies and NGOs concerned by labour rights, EHS or animal welfare. To improve this communication, internet research, a questionnaire distributed via partners and targeted phone calls were used to identify stakeholders' interests and needs. Knowledge gaps and the necessity for further data mentioned by representatives of all stakeholder groups in the targeted phone calls concerned: • the potential toxic and safety hazards of nanomaterials throughout their lifecycles; • the fate and persistence of nanoparticles in humans, animals and the environment; • the associated risks of nanoparticle exposure; • greater participation in: the preparation of nomenclature, standards, methodologies, protocols and benchmarks; • the development of best practice guidelines; • voluntary schemes on responsibility; • databases of materials, research topics and themes, but also of expertise. These findings suggested that stakeholders and NIN researchers share very similar knowledge needs, and that open communication and free movement of knowledge will benefit both researchers and industry. Subsequently a workshop was organised by NIN focused on building a sustainable multi-stakeholder dialogue. Specific questions were asked to different stakeholder groups to encourage discussions and open communication. 1. What information do stakeholders need from researchers and why? The discussions about this question confirmed the needs identified in the targeted phone calls. 2. How to communicate information? While it was agreed that reporting should be enhanced, commercial confidentiality and economic competition were identified as major obstacles. It was recognised that expertise was needed in the areas of commercial law and economics for a wellinformed treatment of this communication issue. 3. Can engineered nanomaterials be used safely? The idea that nanomaterials are probably safe because some of them have been produced 'for a long time', was questioned, since many materials in common use have been proved to be unsafe. The question of safety is also about whether the public has confidence. New legislation like REACH could help with this issue. Hazards do not materialise if exposure can be avoided or at least significantly reduced. Thus, there is a need for information on what can be regarded as acceptable levels of exposure. Finally, it was noted that there is no such thing as a perfectly safe material but only boundaries. At this moment we do not know where these boundaries lie. The matter of labelling of products containing nanomaterials was raised, as in the public mind safety and labelling are connected. This may need to be addressed since the issue of nanomaterials in food, drink and food packaging may be the first safety issue to attract public and media attention, and this may have an impact on 'nanotechnology as a whole. 4. Do we need more or other regulation? Any decision making process should accommodate the changing level of uncertainty. To address the uncertainties, adaptations of frameworks such as REACH may be indicated for nanomaterials. Regulation is often needed even if voluntary measures are welcome because it mitigates the effects of competition between industries. Data cannot be collected on voluntary bases for example. NIN will continue with an active stakeholder dialogue to further build on interdisciplinary relationships towards a healthy future with nanotechnology.
Resumo:
Objective. To measure support for seasonal influenza vaccination requirements among US healthcare personnel (HCP) and its associations with attitudes regarding influenza and influenza vaccination and self-reported coverage by existing vaccination requirements. Design. Between June 1 and June 30, 2010, we surveyed a sample of US HCP ([Formula: see text]) recruited using an existing probability-based online research panel of participants representing the US general population as a sampling frame. Setting. General community. Participants. Eligible HCP who (1) reported having worked as medical doctors, health technologists, healthcare support staff, or other health practitioners or who (2) reported having worked in hospitals, ambulatory care facilities, long-term care facilities, or other health-related settings. Methods. We analyzed support for seasonal influenza vaccination requirements for HCP using proportion estimation and multivariable probit models. Results. A total of 57.4% (95% confidence interval, 53.3%-61.5%) of US HCP agreed that HCP should be required to be vaccinated for seasonal influenza. Support for mandatory vaccination was statistically significantly higher among HCP who were subject to employer-based influenza vaccination requirements, who considered influenza to be a serious disease, and who agreed that influenza vaccine was safe and effective. Conclusions. A majority of HCP support influenza vaccination requirements. Moreover, providing HCP with information about the safety of influenza vaccination and communicating that immunization of HCP is a patient safety issue may be important for generating staff support for influenza vaccination requirements.
Resumo:
Refractory status epilepticus (RSE)-that is, seizures resistant to at least two antiepileptic drugs (AEDs)-is generally managed with barbiturates, propofol, or midazolam, despite a low level of evidence (Rossetti, 2007). When this approach fails, the need for alternative pharmacologic and nonpharmacologic strategies emerges. These have been investigated even less systematically than the aforementioned compounds, and are often used, sometimes in succession, in cases of extreme refractoriness (Robakis & Hirsch, 2006). Several possibilities are reviewed here. In view of the marked heterogeneity of reported information, etiologies, ages, and comedications, it is extremely difficult to evaluate a given method, not to say to compare different strategies among them. Pharmacologic Approaches Isoflurane and desflurane may complete the armamentarium of anesthetics,' and should be employed in a ''close'' environment, in order to prevent intoxication of treating personnel. c-Aminobutyric acid (GABA)A receptor potentiation represents the putative mechanism of action. In an earlier report, isoflurane was used for up to 55 h in nine patients, controlling seizures in all; mortality was, however, 67% (Kofke et al., 1989). More recently, the use of these inhalational anesthetics was described in seven subjects with RSE, for up to 26 days, with an endtidal concentration of 1.2-5%. All patients required vasopressors, and paralytic ileus occurred in three; outcome was fatal in three patients (43%) (Mirsattari et al., 2004). Ketamine, known as an emergency anesthetic because of its favorable hemodynamic profile, is an N-methyl-daspartate (NMDA) antagonist; the interest for its use in RSE derives from animal works showing loss of GABAA efficacy and maintained NMDA sensitivity in prolonged status epilepticus (Mazarati & Wasterlain, 1999). However, to avoid possible neurotoxicity, it appears safer to combine ketamine with GABAergic compounds (Jevtovic-Todorovic et al., 2001; Ubogu et al., 2003), also because of a likely synergistic effect (Martin & Kapur, 2008). There are few reported cases in humans, describing progressive dosages up to 7.5 mg/kg/h for several days (Sheth & Gidal, 1998; Quigg et al., 2002; Pruss & Holtkamp, 2008), with moderate outcomes. Paraldehyde acts through a yet-unidentified mechanism, and appears to be relatively safe in terms of cardiovascular tolerability (Ramsay, 1989; Thulasimani & Ramaswamy, 2002), but because of the risk of crystal formation and its reactivity with plastic, it should be used only as fresh prepared solution in glass devices (Beyenburg et al., 2000). There are virtually no recent reports regarding its use in adults RSE, whereas rectal paraldehyde in children with status epilepticus resistant to benzodiazepines seems less efficacious than intravenous phenytoin (Chin et al., 2008). Etomidate is another anesthetic agent for which the exact mechanism of action is also unknown, which is also relatively favorable regarding cardiovascular side effects, and may be used for rapid sedation. Its use in RSE was reported in eight subjects (Yeoman et al., 1989). After a bolus of 0.3 mg/kg, a drip of up to 7.2 mg/kg/h for up to 12 days was administered, with hypotension occurring in five patients; two patients died. A reversible inhibition of cortisol synthesis represents an important concern, limiting its widespread use and implying a careful hormonal substitution during treatment (Beyenburg et al., 2000). Several nonsedating approaches have been reported. The use of lidocaine in RSE, a class Ib antiarrhythmic agent modulating sodium channels, was reviewed in 1997 (Walker & Slovis, 1997). Initial boluses up to 5 mg/kg and perfusions of up to 6 mg/kg/h have been mentioned; somewhat surprisingly, at times lidocaine seemed to be successful in controlling seizures in patients who were refractory to phenytoin. The aforementioned dosages should not be overshot, in order to keep lidocaine levels under 5 mg/L and avoid seizure induction (Hamano et al., 2006). A recent pediatric retrospective survey on 57 RSE episodes (37 patients) described a response in 36%, and no major adverse events; mortality was not given (Hamano et al., 2006 Verapamil, a calcium-channel blocker, also inhibits P-glycoprotein, a multidrug transporter that may diminish AED availability in the brain (Potschka et al., 2002). Few case reports on its use in humans are available; this medication nevertheless appears relatively safe (under cardiac monitoring) up to dosages of 360 mg/day (Iannetti et al., 2005). Magnesium, a widely used agent for seizures elicited by eclampsia, has also been anecdotally reported in RSE (Fisher et al., 1988; Robakis & Hirsch, 2006), but with scarce results even at serum levels of 14 mm. The rationale may be found in the physiologic blockage of NMDA channels by magnesium ions (Hope & Blumenfeld, 2005). Ketogenic diet has been prescribed for decades, mostly in children, to control refractory seizures. Its use in RSE as ''ultima ratio'' has been occasionally described: three of six children (Francois et al., 2003) and one adult (Bodenant et al., 2008) were responders. This approach displays its effect subacutely over several days to a few weeks. Because ''malignant RSE'' seems at times to be the consequence of immunologic processes (Holtkamp et al., 2005), a course of immunomodulatory treatment is often advocated in this setting, even in the absence of definite autoimmune etiologies (Robakis & Hirsch, 2006); steroids, adrenocorticotropic hormone (ACTH), plasma exchanges, or intravenous immunoglobulins may be used alone or in sequential combination. Nonpharmacologic Approaches These strategies are described somewhat less frequently than pharmacologic approaches. Acute implantation of vagus nerve stimulation (VNS) has been reported in RSE (Winston et al., 2001; Patwardhan et al., 2005; De Herdt et al., 2009). Stimulation was usually initiated in the operation room, and intensity progressively adapted over a few days up to 1.25 mA (with various regimens regarding the other parameters), allowing a subacute seizure control; one transitory episode of bradycardia/asystole has been described (De Herdt et al., 2009). Of course, pending identification of a definite seizure focus, resective surgery may also be considered in selected cases (Lhatoo & Alexopoulos, 2007). Low-frequency (0.5 Hz) transcranial magnetic stimulation (TMS) at 90% of the resting motor threshold has been reported to be successful for about 2 months in a patient with epilepsia partialis continua, but with a weaning effect afterward, implying the need for a repetitive use (Misawa et al., 2005). More recently, TMS was applied in a combination of a short ''priming'' high frequency (up to 100 Hz) and longer runs of low-frequency stimulations (1 Hz) at 90-100% of the motor threshold in seven other patients with simple-partial status, with mixed results (Rotenberg et al., 2009). Paradoxically at first glance, electroconvulsive treatment may be found in cases of extremely resistant RSE. A recent case report illustrates its use in an adult patient with convulsive status, with three sessions (three convulsions each) carried out over 3 days, resulting in a moderate recovery; the mechanism is believed to be related to modification of the synaptic release of neurotransmitters (Cline & Roos, 2007). Therapeutic hypothermia, which is increasingly used in postanoxic patients (Oddo et al., 2008), has been the object of a recent case series in RSE (Corry et al., 2008). Reduction of energy demand, excitatory neurotransmission, and neuroprotective effects may account for the putative mechanism of action. Four adult patients in RSE were cooled to 31_-34_C with an endovascular system for up to 90 h, and then passively rewarmed over 2-50 h. Seizures were controlled in two patients, one of whom died; also one of the other two patients in whom seizures continued subsequently deceased. Possible side effects are related to acid-base and electrolyte disturbances, and coagulation dysfunction including thrombosis, infectious risks, cardiac arrhythmia, and paralytic ileus (Corry et al., 2008; Cereda et al., 2009). Finally, anecdotic evidence suggests that cerebrospinal fluid (CSF)-air exchange may induce some transitory benefit in RSE (Kohrmann et al., 2006); although this approach was already in use in the middle of the twentieth century, the mechanism is unknown. Acknowledgment A wide spectrum of pharmacologic (sedating and nonsedating) and nonpharmacologic (surgical, or involving electrical stimulation) regimens might be applied to attempt RSE control. Their use should be considered only after refractoriness to AED or anesthetics displaying a higher level of evidence. Although it seems unlikely that these uncommon and scarcely studied strategies will influence the RSE outcome in a decisive way, some may be interesting in particular settings. However, because the main prognostic determinant in status epilepticus appears to be related to the underlying etiology rather than to the treatment approach (Rossetti et al., 2005, 2008), the safety issue should always represent a paramount concern for the prescribing physician. Conclusion The author confirms that he has read the Journal's position on issues involved in ethical publication and affirms that this paper is consistent with those guidelines.
Resumo:
Ramp metering has been successfully implemented in many states to improve traffic operations on freeways. Studies have documented the positive mobility and safety benefits of ramp metering. However, there have been no studies on the use of ramp metering for work zones. This report documents the results from the first deployment of temporary ramp meters in work zones in the United States. Temporary ramp meters were deployed at seven urban short-term work zones in Missouri. Safety measures such as driver compliance, merging behavior, and speed differentials were extracted from video-based field data. Mobility analysis was conducted using a calibrated simulation model and the total delays were obtained for under capacity, at capacity, and over capacity conditions. This evaluation suggests that temporary ramp meters should only be deployed at work zone locations where there is potential for congestion and turned on only during above-capacity conditions. The compliance analysis showed that non-compliance could be a major safety issue in the deployment of temporary ramp meters for under-capacity conditions. The use of a three-section instead of a traditional two-section signal head used for permanent ramp metering produced significantly higher compliance rates. Ramp metering decreased ramp platoons by increasing the percentage of single-vehicle merges to over 70% from under 50%. The accepted-merge-headway results were not statistically significant even though a slight shift towards longer headways was found with the use of ramp meters. Mobility analysis revealed that ramp metering produced delay savings for both mainline and ramp vehicles for work zones operating above capacity. On average a 24% decrease in total delay (mainline plus ramp) at low truck percentage and a 19% decrease in delay at high truck percentage conditions resulted from ramp metering.
Resumo:
The Federal Highway Administration estimates that red light running causes more than 100,000 crashes and 1,000 fatalities annually and results in an estimated economic loss of over $14 billion per year in the United States. In Iowa alone, a statewide analysis of red light running crashes, using crash data from 2001 to 2006, indicates that an average of 1,682 red light running crashes occur at signalized intersections every year. As a result, red light running poses a significant safety issue for communities. Communities rarely have the resources to place additional law enforcement in the field to combat the problem and they are increasingly using automated red light running camera-enforcement systems at signalized intersections. In Iowa, three communities currently use camera enforcement since 2004. These communities include Davenport, Council Bluffs, and Clive. As communities across the United States attempt to address red light running, a number of communities have implemented red light running camera enforcement programs. This report examines the red light running programs in Iowa and summarizes results of analyses to evaluate the effectiveness of such cameras.
Resumo:
Chloropropanols are a well-known group of food processing contaminants. They are formed through the reaction between lipids and chlorides when submitted to thermal treatment, and can be found in free and bound form. Although free chloropropanols were identified around 30 years ago, the occurrence of bound forms, especially 3-MCPD, and glycidyl fatty acid esters, has only recently been reported in several food products. Dietary exposure to these ester-bound compounds has been considered a priority food safety issue since free forms can be potentially released through the action of gut lipases, representing a major toxicological concern.
Resumo:
A set of models in Aspen plus was built to simulate the direct synthesis process of hydrogen peroxide in a micro-reactor system. This process model can be used to carry out material balance calculation under various experimental conditions. Three thermodynamic property methods were compared by calculating gas solubility and Uniquac-RK method was finally selected for process model. Two different operation modes with corresponding operation conditions were proposed as the starting point of future experiments. Simulations for these two modes were carried out to get the information of material streams. Moreover, some hydrodynamic parameters such as gas/liquid superficial velocity, gas holdup were also calculated with improved process model. These parameters proved the proposed experimental conditions reasonable to some extent. The influence of operation conditions including temperature, pressure and circulation ratio was analyzed for the first operation mode, where pure oxygen was fed into dissolving tank and hydrogen-carbon dioxide mixture was fed into microreactor directly. The preferred operation conditions for the system are low temperature (2°C) and high pressure (30 bar) in dissolving tank. High circulation ratio might be good in the sense that more oxygen could be dissolved and fed into reactor for reactions, but meanwhile hydrodynamics of microreactor should be considered. Furthermore, more operation conditions of reactor gas/liquid feeds in both of two operation modes were proposed to provide guidance for future experiment design and corresponding hydrodynamic parameters were also calculated. Finally, safety issue was considered from thermodynamic point of view and there is no explosion danger at given experimental plan since the released reaction heat will not cause solvent vaporization inside the microchannels. The improvement of process model still needs further study based on the future experimental results.