445 resultados para ruído


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contemporary world is crowded of large, interdisciplinary, complex systems made of other systems, personnel, hardware, software, information, processes, and facilities. The Systems Engineering (SE) field proposes an integrated holistic approach to tackle these socio-technical systems that is crucial to take proper account of their multifaceted nature and numerous interrelationships, providing the means to enable their successful realization. Model-Based Systems Engineering (MBSE) is an emerging paradigm in the SE field and can be described as the formalized application of modelling principles, methods, languages, and tools to the entire lifecycle of those systems, enhancing communications and knowledge capture, shared understanding, improved design precision and integrity, better development traceability, and reduced development risks. This thesis is devoted to the application of the novel MBSE paradigm to the Urban Traffic & Environment domain. The proposed system, the GUILTE (Guiding Urban Intelligent Traffic & Environment), deals with a present-day real challenging problem “at the agenda” of world leaders, national governors, local authorities, research agencies, academia, and general public. The main purposes of the system are to provide an integrated development framework for the municipalities, and to support the (short-time and real-time) operations of the urban traffic through Intelligent Transportation Systems, highlighting two fundamental aspects: the evaluation of the related environmental impacts (in particular, the air pollution and the noise), and the dissemination of information to the citizens, endorsing their involvement and participation. These objectives are related with the high-level complex challenge of developing sustainable urban transportation networks. The development process of the GUILTE system is supported by a new methodology, the LITHE (Agile Systems Modelling Engineering), which aims to lightening the complexity and burdensome of the existing methodologies by emphasizing agile principles such as continuous communication, feedback, stakeholders involvement, short iterations and rapid response. These principles are accomplished through a universal and intuitive SE process, the SIMILAR process model (which was redefined at the light of the modern international standards), a lean MBSE method, and a coherent System Model developed through the benchmark graphical modeling languages SysML and OPDs/OPL. The main contributions of the work are, in their essence, models and can be settled as: a revised process model for the SE field, an agile methodology for MBSE development environments, a graphical tool to support the proposed methodology, and a System Model for the GUILTE system. The comprehensive literature reviews provided for the main scientific field of this research (SE/MBSE) and for the application domain (Traffic & Environment) can also be seen as a relevant contribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis we perform a detailed analysis of the state of polarization (SOP) of light scattering process using a concatenation of ber-coil based polarization controllers (PCs). We propose a polarization-mode dispersion (PMD) emulator, built through the concatenation of bercoil based PCs and polarization-maintaining bers (PMFs), capable of generate accurate rst- and second-order PMD statistics. We analyze the co-propagation of two optical waves inside a highbirefringence ber. The evolution along the ber of the relative SOP between the two signals is modeled by the de nition of the degree of co-polarization parameter. We validate the model for the degree of co-polarization experimentally, exploring the polarization dependence of the four-wave mixing e ect into a ber with high birefringence. We also study the interaction between signal and noise mediated by Kerr e ect in optical bers. A model accurately describing ampli ed spontaneous emission noise in systems with distributed Raman gain is derived. We show that the noise statistics depends on the propagation distance and on the signal power, and that for distances longer than 120 km and signal powers higher than 6 mW it deviates signi catively from the Gaussian distribution. We explore the all-optical polarization control process based on the stimulated Raman scattering e ect. Mapping parameters like the degree of polarization (DOP), we show that the preferred ampli cation of one particular polarization component of the signal allows a polarization pulling over a wavelength range of 60 nm. The e ciency of the process is higher close to the maximum Raman gain wavelength, where the DOP is roughly constant for a wavelength range of 15 nm. Finally, we study the polarization control in quantum key distribution (QKD) systems with polarization encoding. A model for the quantum bit error rate estimation in QKD systems with time-division multiplexing and wavelength-division multiplexing based polarization control schemes is derived.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A distribui ção de um sinal relógio, com elevada precisão espacial (baixo skew) e temporal (baixo jitter ), em sistemas sí ncronos de alta velocidade tem-se revelado uma tarefa cada vez mais demorada e complexa devido ao escalonamento da tecnologia. Com a diminuição das dimensões dos dispositivos e a integração crescente de mais funcionalidades nos Circuitos Integrados (CIs), a precisão associada as transições do sinal de relógio tem sido cada vez mais afectada por varia ções de processo, tensão e temperatura. Esta tese aborda o problema da incerteza de rel ogio em CIs de alta velocidade, com o objetivo de determinar os limites do paradigma de desenho sí ncrono. Na prossecu ção deste objectivo principal, esta tese propõe quatro novos modelos de incerteza com âmbitos de aplicação diferentes. O primeiro modelo permite estimar a incerteza introduzida por um inversor est atico CMOS, com base em parâmetros simples e su cientemente gen éricos para que possa ser usado na previsão das limitações temporais de circuitos mais complexos, mesmo na fase inicial do projeto. O segundo modelo, permite estimar a incerteza em repetidores com liga ções RC e assim otimizar o dimensionamento da rede de distribui ção de relógio, com baixo esfor ço computacional. O terceiro modelo permite estimar a acumula ção de incerteza em cascatas de repetidores. Uma vez que este modelo tem em considera ção a correla ção entre fontes de ruí do, e especialmente util para promover t ecnicas de distribui ção de rel ogio e de alimentação que possam minimizar a acumulação de incerteza. O quarto modelo permite estimar a incerteza temporal em sistemas com m ultiplos dom ínios de sincronismo. Este modelo pode ser facilmente incorporado numa ferramenta autom atica para determinar a melhor topologia para uma determinada aplicação ou para avaliar a tolerância do sistema ao ru ído de alimentação. Finalmente, usando os modelos propostos, são discutidas as tendências da precisão de rel ogio. Conclui-se que os limites da precisão do rel ogio são, em ultima an alise, impostos por fontes de varia ção dinâmica que se preveem crescentes na actual l ogica de escalonamento dos dispositivos. Assim sendo, esta tese defende a procura de solu ções em outros ní veis de abstração, que não apenas o ní vel f sico, que possam contribuir para o aumento de desempenho dos CIs e que tenham um menor impacto nos pressupostos do paradigma de desenho sí ncrono.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi efetuar um estudo de otimização dos parâmetros de exposição do mamógrafo digital da marca GE, modelo Senographe DS instalado no Instituto Português de Oncologia de Coimbra (IPOC) baseado numa análise contraste detalhe e avaliar o impacto do resultado obtido na melhoria da capacidade de detecção clínica das estruturas da mama. O mamógrafo em estudo dispõe de um sistema de controle automático da exposição designado por sistema AOP (Automatic Optimization of Parameters) que foi otimizado pelo fabricante a partir da razão contraste ruído. O sistema AOP é usado na prática clínica na quase totalidade dos exames de mamografia realizados no IPOC. Tendo em conta o tipo de estrutura que se pretende visualizar na mamografia, nomeadamente estruturas de baixo contraste como as massas e estruturas de dimensão submilimétrica como as microcalcificações, a análise contraste detalhe poderia constituir uma abordagem mais adequada para o estudo de otimização dos parâmetros de exposição uma vez que permitiria uma avaliação conjunta do contraste, da resolução espacial e do ruído da imagem. Numa primeira fase do trabalho foi efetuada a caracterização da prática clínica realizada no mamógrafo em estudo em termos de espessura de mama comprimida “típica”, dos parâmetros técnicos de exposição e das opções de processamento das imagens aplicadas pelo sistema AOP (combinação alvo/filtro, tensão aplicada na ampola - kVp e produto corrente-tempo da ampola - mAs). Numa segunda fase foi realizado um estudo de otimização da qualidade da imagem versus dose na perspectiva dos parâmetros físicos. Para tal foi efetuada uma análise contrastedetalhe no objeto simulador de mama CDMAM e usada uma figura de mérito definida a partir do IQFinv (inverted image quality figure) e da dose glandular média. Os resultados apontaram para uma diferença entre o ponto ótimo resultante do estudo de otimização e o ponto associado aos parâmetros de exposição escolhidos pelo sistema AOP, designadamente no caso da mama pequena. Sendo a qualidade da imagem na perspectiva clínica um conceito mais complexo cujo resultado da apreciação de uma imagem de boa qualidade deve ter em conta as diferenças entre observadores, foi efetuado na última parte deste trabalho um estudo do impacto clínico da proposta de otimização da qualidade de imagem. A partir das imagens realizadas com o objeto simulador antropomórfico TOR MAM simulando uma mama pequena, seis médicos(as) radiologistas com mais de 5 anos de experiência em mamografia avaliaram as imagens “otimizadas” obtidas utilizando-se os parâmetros técnicos de exposição resultantes do estudo de otimização e a imagem resultante da escolha do sistema AOP. A análise estatística das avaliações feitas pelos médicos indica que a imagem “otimizada” da mama pequena apresenta uma melhor visualização das microcalcificações sem perda da qualidade da imagem na deteção de fibras e de massas em comparação com a imagem “standard”. Este trabalho permitiu introduzir uma nova definição da figura de mérito para o estudo de otimização da qualidade da imagem versus dose em mamografia. Permitiu também estabelecer uma metodologia consistente que pode facilmente ser aplicada a qualquer outro mamógrafo, contribuindo para a área da otimização em mamografia digital que é uma das áreas mais relevantes no que toca à proteção radiológica do paciente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of a compact gamma camera with high spatial resolution is of great interest in Nuclear Medicine as a means to increase the sensitivity of scintigraphy exams and thus allow the early detection of small tumours. Following the introduction of the wavelength-shifting fibre (WSF) gamma camera by Soares et al. and evolution of photodiodes into highly sensitive silicon photomultipliers (SiPMs), this thesis explores the development of a WSF gamma camera using SiPMs to obtain the position information of scintillation events in a continuous CsI(Na) crystal. The design is highly flexible, allowing the coverage of different areas and the development of compact cameras, with very small dead areas at the edges. After initial studies which confirmed the feasibility of applying SiPMs, a prototype with 5 5 cm2 was assembled and tested at room temperature, in an active field-of-view of 10 10 mm2. Calibration and characterisation of intrinsic properties of this prototype were done using 57Co, while extrinsic measurements were performed using a high-resolution parallel-hole collimator and 99mTc. In addition, a small mouse injected with a radiopharmaceutical was imaged with the developed prototype. Results confirm the great potential of SiPMs when applied in a WSF gamma camera, achieving spatial resolution performance superior to the traditional Anger camera. Furthermore, performance can be improved by an optimisation of experimental conditions, in order to minimise and control the undesirable effects of thermal noise and non-uniformity of response of multiple SiPMs. The development and partial characterisation of a larger SiPM WSF gamma camera with 10 10 cm2 for clinical application are also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flexible radio transmitters based on the Software-Defined Radio (SDR) concept are gaining an increased research importance due to the unparalleled proliferation of new wireless standards operating at different frequencies, using dissimilar coding and modulation schemes, and targeted for different ends. In this new wireless communications paradigm, the physical layer of the radio transmitter must be able to support the simultaneous transmission of multi-band, multi-rate, multi-standard signals, which in practice is very hard or very inefficient to implement using conventional approaches. Nevertheless, the last developments in this field include novel all-digital transmitter architectures where the radio datapath is digital from the baseband up to the RF stage. Such concept has inherent high flexibility and poses an important step towards the development of SDR-based transmitters. However, the truth is that implementing such radio for a real world communications scenario is a challenging task, where a few key limitations are still preventing a wider adoption of this concept. This thesis aims exactly to address some of these limitations by proposing and implementing innovative all-digital transmitter architectures with inherent higher flexibility and integration, and where improving important figures of merit, such as coding efficiency, signal-to-noise ratio, usable bandwidth and in-band and out-of-band noise will also be addressed. In the first part of this thesis, the concept of transmitting RF data using an entirely digital approach based on pulsed modulation is introduced. A comparison between several implementation technologies is also presented, allowing to state that FPGAs provide an interesting compromise between performance, power efficiency and flexibility, thus making them an interesting choice as an enabling technology for pulse-based all-digital transmitters. Following this discussion, the fundamental concepts inherent to pulsed modulators, its key advantages, main limitations and typical enhancements suitable for all-digital transmitters are also presented. The recent advances regarding the two most common classes of pulse modulated transmitters, namely the RF and the baseband-level are introduced, along with several examples of state-of-the-art architectures found on the literature. The core of this dissertation containing the main developments achieved during this PhD work is then presented and discussed. The first key contribution to the state-of-the-art presented here consists in the development of a novel ΣΔ-based all-digital transmitter architecture capable of multiband and multi-standard data transmission in a very flexible and integrated way, where the pulsed RF output operating in the microwave frequency range is generated inside a single FPGA device. A fundamental contribution regarding the simultaneous transmission of multiple RF signals is then introduced by presenting and describing novel all-digital transmitter architectures that take advantage of multi-gigabit data serializers available on current high-end FPGAs in order to transmit in a time-interleaved approach multiple independent RF carriers. Further improvements in this design approach allowed to provide a two-stage up-conversion transmitter architecture enabling the fine frequency tuning of concurrent multichannel multi-standard signals. Finally, further improvements regarding two key limitations inherent to current all-digital transmitter approaches are then addressed, namely the poor coding efficiency and the combined high quality factor and tunability requirements of the RF output filter. The followed design approach based on poliphase multipath circuits allowed to create a new FPGA-embedded agile transmitter architecture that significantly improves important figures of merit, such as coding efficiency and SNR, while maintains the high flexibility that is required for supporting multichannel multimode data transmission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tese apresenta algoritmos que estimam o espetro de um sinal não periódico a partir de um numero finito de amostras, tirando partido da esparsidade do sinal no domínio da frequência. Trata-se de um problema em que devido aos efeitos de leakage, o sucesso dos algoritmos tradicionais esta limitado. Para ultrapassar o problema, os algoritmos propostos transformam a base DFT numa frame com um maior numero de colunas, inserindo um numero reduzido de colunas entre algumas das iniciais. Estes algoritmos são baseados na teoria do compressed sensing, que permite obter e representar sinais esparsos e compressíveis, utilizando uma taxa de amostragem muito inferior à taxa de Nyquist. Os algoritmos propostos apresentam um bom desempenho em comparação com os algoritmos existentes, destacando-se na estimação do espetro de sinais compostos por sinusóides com frequências muito próximas, com amplitudes diferentes e na presença de ruído, situação particularmente difícil e perante a qual os restantes algoritmos falham.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work several techniques to monitor the performance of optical networks were developed. These techniques are dedicated either to the measurement of the data signal parameters (optical signal to noise ratio and dispersion) or to the detection of physical failures on the network infrastructure. The optical signal to noise ratio of the transmitted signal was successfully monitored using methods based on the presence of Bragg gratings imprinted on high birefringent fibres that allowed the distinction of the signal from the noise due to its polarization properties. The monitoring of the signal group-velocity dispersion was also possible. In this case, a method based on the analysis of the electric spectrum of the signal was applied. It was experimentally demonstrated that this technique is applicable on both amplitude and phase modulated signals. It was also developed a technique to monitor the physical infrastructure of an optical access network. Once again, the application of Bragg gratings (this time imprinted on standard single mode fibres) was the basis of the developed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of computed tomography systems with energy resolving detectors is a current challenge in medical physics and biomedical engineering. A computed tomography system of this kind allows getting complementary informations relatively to conventional systems, that can help the medical diagnosis, being of great interest in medicine. The work described in this thesis is related to the development of a computed tomography system using micropattern gaseous detectors, which allow storing, simultaneously, information about the interaction position and the energy of each single photon that interacts with the detector. This kind of detectors has other advantages concerning the cost and characteristics of operation when compared with solid state detectors. Tomographic acquisitions were performed using a MicroHole & Strip Plate based detector, which allowed reconstructing cross-sectional images using energy windows, applying the energy weighting technique and performing multi-slice and tri-dimensional reconstructions. The contrast-to-noise ratio was improved by 31% by applying the energy weighting technique, comparing with the corresponding image obtained with the current medical systems. A prototype of a computed tomography with flexibility to change the detector was developed, making it possible to apply different detectors based on Thick-COBRA. Several images acquired with these detectors are presented and demonstrate their applicability in X-ray imaging. When operating in NeCH4, the detector allowed a charge gain of 8 104, an energy resolution of 20% (full width at half maximum at 8 keV), a count rate of 1 106 Hz/mm2, a very stable operation (gain fluctuations below 5%) and a spacial resolution of 1.2 mm for an energy photon of 3.6 keV. Operating the detector in pure Kr allowed increasing the detection efficiency and achieving a charge gain of 2 104, an energy resolution of 32% (full width at half maximum at 22 keV), a count rate of 1 105 Hz/mm2, very stable operation and a spatial resolution of 500 m. The software already existing in the group was improved and tools to correct geometric misalignments of the system were also developed. The reconstructions obtained after geometrical correction are free of artefacts due to the referred misalignments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As últimas décadas têm sido caracterizadas por uma crescente indefinição do design, que refletindo um dia-a-dia cada vez mais complexo, não pode mais ser encarado como actividade fechada no projecto e acabada no produto. O seu universo aumentou e dispersou-se em mercados menores, alargando o seu alcance e sua importância, transformando-o em termo quantitativo e inflacionário. A crescente atenção de que é alvo dramatizou a sua relação com o consumo, o ruído nas prateleiras e a superficialidade da generalização de uma perspectiva do projecto focada nos new media, validando uma abordagem narcisista e de dispensa do diálogo com a indústria, tornaram-no sinónimo de especial. Este trabalho procura confirmar e refletir sobre a existência de um universo de produtos concretos e abordagens que de forma consciente partilham esta noção do contexto actual, em primeiro lugar, sugerindo caminhos alternativos e reacções resultantes da prática e discurso. Em segundo lugar procura analisar se tal reacção pode ser considerada como um movimento. Partindo de uma revisão bibliográfica, e de uma reflexão sobre um universo de produtos do dia-a-dia, procura-se, em terceiro lugar, interpretar e organizar as diversas formas e estratégias de rejeição da noção de design especial. Da procura de abordagens opostas a especial resulta uma ideia base de normal, normal sem ser banal, expressa na exposição Super Normal. Da extensão a um universo maior de produtos, reacções e autores, resulta a ideia de normal como um conceito mais abrangente, mas composto por conceitos menores, mais específicos, mais concretos e fáceis de identificar nos objectos. A organização e interpretação dessas abordagens resulta num triângulo de conceitos que constroem a noção de normal pela procura da evolução por recurso à memória e ao conhecimento, da invisibilidade pela integração e diluição do produto e projecto, e da liberdade como meio de adequação ao contexto actual. O livro resultante reflete uma abordagem definida de uma época, e não todo o panorama. A sistematização do conceito de normal a partir da segmentação em ideias menores, mais concretas e identificáveis nos produtos, procura proporcionar a consulta organizada de reacções ao contexto dominante actual, à ideia de especial, mas mais do que regras, procura fornecer um documento de reflexão a visitar no acto de projectar, seja como um todo, ou em partes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho teve como objetivos a produção, caracterização e aplicação de microelétrodos (MEs) de diamante como sensores amperométricos e potenciométricos em sistemas de corrosão nos quais a agressividade do meio e a presença de produtos de corrosão, constituem obstáculos que podem diminuir o desempenho, ou inviabilizar a utilização, de outros tipos de sensores. Os microeléctrodos são baseados em filmes finos de diamante dopado com boro (BDD – Boron Doped Diamond) depositados sobre fios de tungsténio afiados, através do método de deposição química a partir da fase vapor, assistida por filamento quente (HFCVD – Hot Filament Chemical Vapor Deposition). A otimização das diversas etapas de fabricação dos MEs deu origem ao desenvolvimento de um novo sistema de afiamento eletroquímico para obtenção destes fios e a várias opções para a obtenção dos filmes de diamante condutor e seu isolamento com resinas para exposição apenas da ponta cilíndrica. A qualidade cristalina dos filmes de diamante foi avaliada por espectroscopia de Raman. Esta informação foi complementada com uma caracterização microestrutural dos filmes de diamante por microscopia eletrónica de varrimento (SEM), em que se fez a identificação da tipologia dos cristais como pertencendo às gamas de diamante nanocristalino ou microcristalino. Os filmes de BDD foram utilizados na sua forma não modificada, com terminações em hidrogénio e também com modificação da superfície através de tratamentos de plasma RF de CF4 e O2 indutores de terminações C-F no primeiro caso e de grupos C=O, C-O-C e C-OH no segundo, tal como determinado por XPS. A caracterização eletroquímica dos MEs não modificados revelou uma resposta voltamétrica com elevada razão sinal/ruído e baixa corrente capacitiva, numa gama de polarização quasi-ideal com extensão de 3 V a 4 V, dependente dos parâmetros de crescimento e pós-tratamentos de superfície. Estudou-se a reversibilidade de algumas reações heterogéneas com os pares redox Fe(CN)6 3-/4- e FcOH0/+ e verificou-se que a constante cinética, k0, é mais elevada em elétrodos com terminações em hidrogénio, nos quais não se procedeu a qualquer modificação da superfície. Estes MEs não modificados foram também testados na deteção de Zn2+ onde se observou, por voltametria cíclica, que a detecção da redução deste ião é linear numa escala log-log na gama de 10-5-10-2 M em 5 mM NaCl. Realizaram-se também estudos em sistemas de corrosão modelares, em que os microeléctrodos foram usados como sensores amperométricos para mapear a distribuição de oxigénio e Zn2+ sobre um par galvânico Zn-Fe, com recurso a um sistema SVET (Scanning Vibrating Electrode Technique). Foi possível detetar, com resolução lateral de 100 μm, um decréscimo da concentração de O2 junto a ambos os metais e produção de catiões de zinco no ânodo. Contudo verificou-se uma significativa deposição de zinco metálico na superfície dos ME utilizados. Os MEs com superfície modificada por plasma de CF4 foram testados como sensores de oxigénio dissolvido. A calibração dos microeléctrodos foi efetuada simultaneamente por voltametria cíclica e medição óptica através de um sensor de oxigénio comercial. Determinou-se uma sensibilidade de ~0.1422 nA/μM, com um limite de deteção de 0.63 μM. Os MEs modificados com CF4 foram também testados como sensores amperométricos com os quais se observou sensibilidade ao oxigénio dissolvido em solução, tendo sido igualmente utilizados durante a corrosão galvânica de pares Zn-Fe. Em alguns casos foi conseguida sensibilidade ao ião Zn2+ sem que o efeito da contaminação superficial com zinco metálico se fizesse sentir. Os microeléctrodos tratados em plasma de CF4 permitem uma boa deteção da distribuição de oxigénio, exibindo uma resposta mais rápida que os não tratados além de maior estabilidade de medição e durabilidade. Nos MEs em que a superfície foi modificada com plasma de O2 foi possível detetar, por cronopotenciometria a corrente nula, uma sensibilidade ao pH de ~51 mV/pH numa gama de pH 2 a pH 12. Este comportamento foi associado à contribuição determinante de grupos C-O e C=O, observados por XPS com uma razão O/C de 0,16. Estes MEs foram igualmente testados durante a corrosão galvânica do par Zn-Fe onde foi possível mapear a distribuição de pH associada ao desenvolvimento de regiões alcalinas causadas pela redução do oxigénio, acima da região catódica, e de regiões ácidas decorrentes da dissolução anódica do ânodo de zinco. Com o par galvânico imerso em 50 mM NaCl registou-se uma variação de pH aproximadamente entre 4,8 acima do ânodo de zinco a 9,3 sobre o cátodo de ferro. A utilização pioneira destes MEs como sensores de pH é uma alternativa promissora aos elétrodos baseados em membranas seletivas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos últimos anos o estudo de estruturas inteligentes tem atraído vários investigadores devido às suas potenciais vantagens numa larga gama de aplicações, tais como controle de forma, supressão de vibrações, atenuação de ruído e detecção de dano. O uso de materiais “inteligentes” tal como os materiais piezoeléctricos na forma de lâminas ou “patches”, embebidas ou coladas na superfície de estruturas construídas de materiais compósitos, permite assim obter estruturas que por um lado são adaptativas e por outro revelam excelentes propriedades mecânicas, aumentando assim bastante o desempenho e a fiabilidade de sistemas estruturais. Os materiais piezoeléctricos têm a propriedade de gerar uma carga eléctrica sob a acção duma carga mecânica e o reverso, isto é, aplicando um campo eléctrico nos elementos piezoeléctricos da estrutura, esta deforma-se. Neste trabalho, é apresentado um modelo de elementos finitos, baseado na teoria clássica de placas, desenvolvido para a análise do controle activo em estática e dinâmica lineares de estruturas integrando sensores e actuadores piezoeléctrico na forma de lâminas, os quais introduzem um grau de liberdade referente ao potencial eléctrico, por cada camada piezoeléctrica do elemento finito. É utilizado método de Newmark para a solução iterativa das equações de equilíbrio. Apresentam-se os resultados obtidos em três exemplos ilustrativos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Engenharia Eléctrica e Electrónica, Ramo de Tecnologias de Informação e Telecomunicações, Instituto Superior de Engenharia, Universidade do Algarve, 2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Gestão da Água e da Costa, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O processamento de sinais de fluxo sanguíneo tem sido objecto de interesse de muitos investigadores, no entanto até este momento, tanto quanto se sabe, não existe caracterização de sinais de ultra-som Doppler de fluxo sanguíneo em vasos cardíacos com inserção de bypass. A presente dissertação, inserida nos objectivos de um projecto de investigação internacional, apresenta as metodologias desenvolvidas com vista à tipificação de sinais ultra-sónicos de fluxo sanguíneo recolhidos em bypass cardíacos e à verificação da variabilidade da composição do sangue artificial com a temperatura ambiente e com a utilização de diferentes marcas dos seus compostos. No que concerne à composição do sangue artificial verifica-se que a utilização de detergentes de marcas diferentes não influencia o espectrograma dos sinais ultra-sónicos; contudo, o glicerol brasileiro possibilita melhor dispersão das partículas de PVC que o glicerol português. Verifica-se também que o aumento da temperatura a que o sangue artificial e o ambiente envolvente se encontram potencia claramente a identificação das envolventes do espectrograma correspondente. Os sinais ultra-sónicos de fluxo sanguíneo foram distinguidos em siglas FL, FR e FT e foram pré-processados removendo-se o ruído de baixas frequências (até 430Hz) e as baixas intensidades de potência (inferiores a um limiar de 35). Após a determinação da envolvente dos ciclos cardíacos, foi calculado o ciclo cardíaco médio de cada sigla. Analisando as características dos ciclos cardíacos médios: tempos de subida e descida do pico máximo, tempo acima da média do ciclo cardíaco médio, índice de pulsatilidade, frequências máxima e média e ainda a duração temporal, conseguiu identificar-se que os sinais FT apresentam durações temporais maiores e um espectrograma maioritariamente acima da frequência média do ciclo cardíaco, os sinais FR apresentam maior índice de pulsatilidade e maiores valores de frequência máxima. Os sinais FL apresentam características intermédias.