870 resultados para rib fracture
Resumo:
To evaluate the sensitivity of postmortem computed tomography (PMCT) in rib fracture detection validated against autopsy. Fifty-one forensic cases underwent a postmortem CT prior to forensic autopsy. Two image readers (radiologist and forensic pathologist) assessed high resolution CT data sets for rib fractures. Correct recognition rates (CRR), sensitivity and specificity values were calculated over all observations as well as individually for every rib and region. Additionally, for partial rib fractures the sensitivity of autopsy was calculated vice versa. 3876 entries in each study protocol (autopsy, PMCT radiologist and PMCT forensic pathologist) were investigated. A total of 690 fractures (autopsy), 491 (PMCT and radiologist) and 559 (PMCT and forensic pathologist) were detected. The CRR was 0.85. Sensitivity and specificity of PMCT for rib fracture detection were 0.63 (0.58 radiologist, 0.68 forensic pathologist) and 0.97 (both readers 0.97), respectively. Low CRR and sensitivity values were obtained for antero-lateral fractures. Partial rib fractures were better detected by PMCT. PMCT has a rather low sensitivity for rib fracture detection when validated against autopsy and indicates that clinical CT may also demonstrate a reasonable number of false negatives. Partial rib fractures often remain undetected at autopsy.
Resumo:
To complement the existing treatment guidelines for all tumour types, ESMO organises consensus conferences to focus on specific issues in each type of tumour. The 2nd ESMO Consensus Conference on Lung Cancer was held on 11-12 May 2013 in Lugano. A total of 35 experts met to address several questions on non-small-cell lung cancer (NSCLC) in each of four areas: pathology and molecular biomarkers, first-line/second and further lines in advanced disease, earlystage disease and locally advanced disease. For each question, recommendations were made including reference to the grade of recommendation and level of evidence. This consensus paper focuses on early-stage disease. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved.
Resumo:
Context: Tumor-induced osteomalacia (TIO) is a rarely diagnosed disorder presenting with bone pain, fractures, muscle weakness, and moderate-to-severe hypophosphatemia resulting from fibroblast growth factor 23-mediated renal phosphate wasting. Tumors secreting fibroblast growth factor 23 are often small and difficult to find with conventional imaging. Objective: We studied the utility of 68Ga-DOTA-octreotate (DOTATATE) somatostatin receptor positron emission tomography (PET)/computed tomography (CT) imaging in the diagnosis of TIO. Design and Setting: A multicenter case series was conducted at tertiary referral hospitals. Patients and Methods: Six patients with TIO diagnosed between 2003 and 2012 in Australia were referred for DOTATATE PET imaging. We reviewed the clinical history, biochemistry, imaging characteristics, histopathology, and clinical outcome of each patient. Results: Each case demonstrated delayed diagnosis despite severe symptoms. DOTATATE PET/CT imaging demonstrated high uptake and localized the tumor with confidence in each case. After surgical excision, there was resolution of clinical symptoms and serum phosphate, except in one patient who demonstrated residual disease on PET/CT. All tumors demonstrated high somatostatin receptor subtype 2 cell surface receptor expression using immunohistochemistry. Conclusions: In patients with TIO, DOTATATE PET/CT can successfully localize phosphaturic mesenchymal tumors and may be a practical first step in functional imaging for this disorder. Serum phosphate should be measured routinely in patients with unexplained muscle weakness, bone pain, or stress fractures to allow earlier diagnosis of TIO. - See more at: http://press.endocrine.org/doi/abs/10.1210/jc.2012-3642#sthash.eXD0CopL.dpuf
Resumo:
AIMS: To determine the incidence and predictive factors of rib fracture and chest wall pain after lung stereotactic ablative radiotherapy (SABR).
MATERIALS AND METHODS: Patients were treated with lung SABR of 48-60 Gy in four to five fractions. The treatment plan and follow-up computed tomography scans of 289 tumours in 239 patients were reviewed. Dose-volume histogram (DVH) metrics and clinical factors were evaluated as potential predictors of chest wall toxicity.
RESULTS: The median follow-up was 21.0 months (range 6.2-52.1). Seventeen per cent (50/289) developed a rib fracture, 44% (22/50) were symptomatic; the median time to fracture was 16.4 months. On univariate analysis, female gender, osteoporosis, tumours adjacent (within 5 mm) to the chest wall and all of the chest wall DVH metrics predicted for rib fracture, but only tumour location adjacent to the chest wall remained significant on the multivariate model (P < 0.01). The 2 year fracture-free probability for those adjacent to the chest wall was 65.6%. Among those tumours adjacent to the chest wall, only osteoporosis (P = 0.02) predicted for fracture, whereas none of the chest wall DVH metrics were predictive. Eight per cent (24/289) experienced chest wall pain without fracture.
CONCLUSIONS: None of the chest wall DVH metrics independently predicted for SABR-induced rib fracture when tumour location is taken into account. Patients with tumours adjacent (within 5 mm) to the chest wall are at greater risk of rib fracture after lung SABR, and among these, an additional risk was observed in osteoporotic patients.
Resumo:
The primary aims of scoliosis surgery are to halt the progression of the deformity, and to reduce its severity (cosmesis). Currently, deformity correction is measured in terms of posterior parameters (Cobb angles and rib hump), even though the cosmetic concern for most patients is anterior chest wall deformity. In this study, we propose a new measure for assessing anterior chest wall deformity and examine the correlation between rib hump and the new measure. 22 sets of CT scans were retrieved from the QUT/Mater Paediatric Spinal Research Database. The Image J software (NIH) was used to manipulate formatted CT scans into 3-dimensional anterior chest wall reconstructions. A ‘chest wall angle’ was then measured in relation to the first sacral vertebral body. The chest wall angle was found to be a reliable tool in the analysis of chest wall deformity. No correlation was found between the new measure and rib hump angle. Since rib hump has been shown to correlate with vertebral rotation on CT, this suggests that there maybe no correlation between anterior and posterior deformity measures. While most surgical procedures will adequately address the coronal imbalance & posterior rib hump elements of scoliosis, they do not reliably alter the anterior chest wall shape. This implies that anterior chest wall deformity is to a large degree an intrinsic deformity, not directly related to vertebral rotation.
Resumo:
Bone graft is generally considered fundamental in achieving solid fusion in scoliosis correction and pseudarthrosis following instrumentation may predispose to implant failure. In endoscopic anterior-instrumented scoliosis surgery, autologous rib or iliac crest graft has been utilised traditionally but both techniques increase operative duration and cause donor site morbidity. Allograft bone and bone- morphogenetic-protein alternatives may improve fusion rates but this remains controversial. This study's objective was to compare two-year postoperative fusion rates in a series of patients who underwent endoscopic anterior instrumentation for thoracic scoliosis utilising various bone graft types. Significantly better rates of fusion occurred in endoscopic anterior instrumented scoliosis correction using femoral allograft compared to autologous rib-heads and iliac crest graft. This may be partly explained by the difficulty obtaining sufficient quantities of autologous graft. Lower fusion rates in the autologous graft group appeared to predispose to rod fracture although the clinical consequence of implant failure is uncertain.
Resumo:
The healing process for bone fractures is sensitive to mechanical stability and blood supply at the fracture site. Most currently available mechanobiological algorithms of bone healing are based solely on mechanical stimuli, while the explicit analysis of revascularization and its influences on the healing process have not been thoroughly investigated in the literature. In this paper, revascularization was described by two separate processes: angiogenesis and nutrition supply. The mathematical models for angiogenesis and nutrition supply have been proposed and integrated into an existing fuzzy algorithm of fracture healing. The computational algorithm of fracture healing, consisting of stress analysis, analyses of angiogenesis and nutrient supply, and tissue differentiation, has been tested on and compared with animal experimental results published previously. The simulation results showed that, for a small and medium-sized fracture gap, the nutrient supply is sufficient for bone healing, for a large fracture gap, non-union may be induced either by deficient nutrient supply or inadequate mechanical conditions. The comparisons with experimental results demonstrated that the improved computational algorithm is able to simulate a broad spectrum of fracture healing cases and to predict and explain delayed unions and non-union induced by large gap sizes and different mechanical conditions. The new algorithm will allow the simulation of more realistic clinical fracture healing cases with various fracture gaps and geometries and may be helpful to optimise implants and methods for fracture fixation.
Resumo:
The fracture healing process is modulated by the mechanical environment created by imposed loads and motion between the bone fragments. Contact between the fragments obviously results in a significantly different stress and strain environment to a uniform fracture gap containing only soft tissue (e.g. haematoma). The assumption of the latter in existing computational models of the healing process will hence exaggerate the inter-fragmentary strain in many clinically-relevant cases. To address this issue, we introduce the concept of a contact zone that represents a variable degree of contact between cortices by the relative proportions of bone and soft tissue present. This is introduced as an initial condition in a two-dimensional iterative finite element model of a healing tibial fracture, in which material properties are defined by the volume fractions of each tissue present. The algorithm governing the formation of cartilage and bone in the fracture callus uses fuzzy logic rules based on strain energy density resulting from axial compression. The model predicts that increasing the degree of initial bone contact reduces the amount of callus formed (periosteal callus thickness 3.1mm without contact, down to 0.5mm with 10% bone in contact zone). This is consistent with the greater effective stiffness in the contact zone and hence, a smaller inter-fragmentary strain. These results demonstrate that the contact zone strategy reasonably simulates the differences in the healing sequence resulting from the closeness of reduction.
Resumo:
This work investigates the effect of rib stiffeners on the free and forced vibration of a gradient coil in a Magnetic Resonance Imaging (MRI) scanner. Several reinforcement schemes are studied in this paper. One scheme utilizes the existing holes in the gradient coil structure (typically reserved for magnetic shims) to produce the reinforcement. Non-ferrous, non-magnetic carbon fibre rib stiffeners are employed to fill these holes in several ways to strengthen a gradient coil. Another scheme replaces the inner half of the gradient coil material with a grid of interconnected axial and circumferential rib stiffeners. It is found that the structural stiffness of the gradient coil increases substantially when the coil is reinforced by carbon fibre rib stiffeners. The reinforcement affects the noise and vibration response of the gradient coil structure in the following ways. It increases the frequency range of forced response of the gradient coil at low frequencies due to the increased resonant frequency of the fundamental mode of the coil. Secondly, it reduces the forced response amplitude of the coil structure (which is governed by the structural stiffness of the coil). Thirdly, it reduces the number of natural modes in the low and medium frequency range and therefore lessens the chance of the coil structure being excited resonantly by magnetic resonance signal acquisition sequences. It is shown that gradient coils modelled by solid finite element models have higher stiffness along the coil’s circumference and lower stiffness in the axial direction than those using shell finite element models.
Resumo:
Vertebrplasty involved injecting cement into a fractured vertebra to provide stabilisation. There is clinical evidence to suggest however that vertebroplasty may be assocated with a higher risk of adjacent vertebral fracture; which may be due to the change in material properties of the post-procedure vertebra modifying the transmission of mechanical stresses to adjacent vertebrae.
Resumo:
Adolescent Idiopathic Scoliosis (AIS) has been associated with reduced pulmonary function believed to be due to a restriction of lung volume by the deformed thoracic cavity. A recent study by our group examined the changes in lung volume pre and post anterior thoracoscopic scoliosis correction using pulmonary function testing (1), however the anatomical changes in ribcage shape and left/right lung volume after thoracoscopic surgery which govern overall respiratory capacity are unknown. The aim of this study was to use 3D rendering from CT scan data to compare lung and ribcage anatomical changes from pre to two years post thoracoscopic anterior scoliosis correction. The study concluded that 3D volumetric reconstruction from CT scans is a powerful means of evaluating changes in pulmonary and thoracic anatomy following surgical AIS correction. Most likely, lung volume changes following thoracoscopic scoliosis correction are multifactorial and affected by changes in height (due to residual growth), ribcage shape, diaphragm positioning, Cobb angle correction in the thoracic spine. Further analysis of the 3D reconstructions will be performed to assess how each of these factors affect lung volume in this patient cohort.
Resumo:
Fracture behavior of Cu-Ni laminate composites has been investigated by tensile testing. It was found that as the individual layer thickness decreases from 100 to 20nm, the resultant fracture angle of the Cu-Ni laminate changes from 72 degrees to 50 degrees. Cross-sectional observations reveal that the fracture of the Ni layers transforms from opening to shear mode as the layer thickness decreases while that of the Cu layers keeps shear mode. Competition mechanisms were proposed to understand the variation in fracture mode of the metallic laminate composites associated with length scale.