992 resultados para ramsay sedation scale


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. METHODS: Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. RESULTS: The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. CONCLUSIONS: Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The objective of the present study was to evaluate the degree of sedation, intraocular pressure, and hemodynamic changes with premedication with low doses of oral clonidine, 100 μg and 200 μg, in outpatient cataract surgeries. METHODS: This is a randomized, double-blind, clinical study undertaken at the Universidade Federal de São Paulo with 60 patients of both genders, physical status ASA 1 and 2, ages 18 to 80 years. Patients were separated into three groups: placebo, clonidine 100 μg, and clonidine 200 μg. Intraocular pressure, heart rate, and blood pressure besides assessment of sedation were measured before and 90 minutes after the administration of clonidine. Sedation levels were classified according to the Ramsay sedation scale. RESULTS: Patients who received placebo and 100 μg of clonidine did not show reduction in heart rate, while a reduction in heart rate was observed in patients who received 200 μg of clonidine, and this difference was statistically significant. Patients who received 200 μg of clonidine also had a reduction in systolic and diastolic blood pressure (p < 0.05). One patient who received 200 μg of clonidine developed severe hypotension, with systolic pressure < 80 mmHg. Patients treated with clonidine had a reduction in intraocular pressure (p < 0.05). Ninety minutes after the oral administration of placebo and 100 μg and 200 μg of clonidine, 25%, 60%, and 80% of the patients respectively were classified as Ramsay 3 or 4. CONCLUSIONS: Clonidine 100 μg can be indicated as premedication for fasciectomies, being effective in sedation and reduction of intraocular pressure, without adverse effects on blood pressure and heart rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and objectives: Extracorporeal circulation (ECC) may change drug pharmacokinetics as well as brain function. The objectives of this study are to compare emergence time and postoperative sedation intensity assessed by the bispectral index (BIS) and the Ramsay sedation scale in patients undergoing myocardial revascularization (MR) with or without ECC. Method: Ten patients undergoing MR with ECC (ECC group) and 10 with no ECC (no-ECC group) were administered with sufentanyl, propofol 2.0 mu g.mL(-1) and pancuronium target controlled infusion. After surgery, propofol infusion was reduced to 1 mu g.mL(-1) and suspended when extubation was indicated. Patients BIS, Ramsay scale and time to wake up were assessed. Results: The ECC group showed lower BIS values beginning at 60 minutes after surgery (no-ECC = 66 +/- 13 and ECC = 53 +/- 14, p = 0.01) until 120 minutes after infusion (no-ECC = 85 +/- 8 and ECC = 73 +/- 12, p = 0.02). Sedation level measured by the Ramsay scale was higher in the ECC group at 30 minutes after the end of the surgery (no-ECC = 5 +/- 1 and ECC = 6 +/- 0, p = 0.021), at the end of infusion (no-ECC = 5 +/- 1 and ECC = 6 +/- 1, p = 0.012) and 5 minutes after the end of infusion (no-ECC = 4 +/- 1 and ECC = 5 +/- 0.42, p = 0.039). Emergence from anesthesia time was higher in the ECC group (no-ECC = 217 +/- 81 and ECC = 319 +/- 118, p = 0.038). Conclusions: There was a higher intensity of sedation after the end of surgery and a longer wake up time in ECC group, suggesting changes in the pharmacokinetics of propofol or effects of ECC on central nervous system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Sleep disturbances are common in critically ill patients treated in the intensive care unit (ICU) with the potential for serious consequences and long-term effects on health outcomes and patient morbidity.
Objectives Our aim was to describe sleep management and sedation practices of adult ICUs in ten countries and to evaluate roles and responsibilities of the ICU staff in relation to key sleep and sedation decisions.
Methods A multicenter, self-administered survey sent to nurse managers of adult ICUs across 10 countries. The questionnaire comprised four domains: sleep characteristics of the critically ill; sleep and sedation practices; non-pharmacological and pharmacological interventions used to improve sleep; and the autonomy and influence of nurses on sleeping practices in the ICU.
Results Overall response rate was 66% (range 32% UK to 100% Cyprus), providing data from 522 ICUs. In all countries, the most frequent patient characteristic perceived to identify sleep was lying quietly with closed eyes (N=409, 78%) (range 92% Denmark to 36% Italy). The most commonly used sedation scale was the Richmond Agitation-Sedation Score (RASS) (N=220, 42%) (range 81% UK to 0% Denmark, Cyprus where most ICUs used the Ramsay score). In most ICUs, selection of sleep medication (N=265, 51%) and assessment of effect (N=309, 59%) was performed by physicians and nurses based on collaborative discussion. In a minority of ICUs (N=161, 31%), decisions and assessments were made by physicians alone. The most commonly used (in all countries) non-pharmacological intervention to promote sleep was reducing ICU staff noise (N=473, 91%) (range 100% Denmark, Norway to 78% Canada). Only 95 ICUs (18%) used earplugs on a frequent basis (range 0% Greece, Cyprus, Denmark to 57% Sweden). Propofol was the drug used most commonly for sedation (N=359, 69%) (range 96% Sweden to 29% Canada). Chloral hydrate was used by only 63 (12%) ICUs (range 0% Greece, Cyprus, Denmark, Italy to 56% Germany). Sedation scales were used on a routine basis by 77% of the 522 ICUs. Participants scored nursing autonomy for sleep and sedation management as moderate; median score of 5 (scale of 0 to 10), range 7 (Canada, Greece, Sweden) to 4 (Norway, Poland). Nursing influence on sleep and sedation decisions was perceived considerable; median score 8, range 9 (Denmark) to 5 (Poland).
Conclusions We found considerable across country variation in sleep promotion and sedation management practices though most have adopted a sedation scale as recommended in professional society guidelines. Most ICUs in all countries used a range of pharmacological and non-pharmacological interventions to promote sleep. Most units reported inter-professional decision-making with nurses perceived to have substantial influence on sleep/sedation decisions.


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The cardiac catheterisation laboratory (CCL) is a specialised medical radiology facility where both chronic-stable and life-threatening cardiovascular illness is evaluated and treated. Although there are many potential sources of discomfort and distress associated with procedures performed in the CCL, a general anaesthetic is not usually required. For this reason, an anaesthetist is not routinely assigned to the CCL. Instead, to manage pain, discomfort and anxiety during the procedure, nurses administer a combination of sedative and analgesic medications according to direction from the cardiologist performing the procedure. This practice is referred to as nurse-administered procedural sedation and analgesia (PSA). While anecdotal evidence suggested that nurse-administered PSA was commonly used in the CCL, it was clear from the limited information available that current nurse-led PSA administration and monitoring practices varied and that there was contention around some aspects of practice including the type of medications that were suitable to be used and the depth of sedation that could be safely induced without an anaesthetist present. The overall aim of the program of research presented in this thesis was to establish an evidence base for nurse-led sedation practices in the CCL context. A sequential mixed methods design was used over three phases. The objective of the first phase was to appraise the existing evidence for nurse-administered PSA in the CCL. Two studies were conducted. The first study was an integrative review of empirical research studies and clinical practice guidelines focused on nurse-administered PSA in the CCL as well as in other similar procedural settings. This was the first review to systematically appraise the available evidence supporting the use of nurse-administered PSA in the CCL. A major finding was that, overall, nurse-administered PSA in the CCL was generally deemed to be safe. However, it was concluded from the analysis of the studies and the guidelines that were included in the review, that the management of sedation in the CCL was impacted by a variety of contextual factors including local hospital policy, workforce constraints and cardiologists’ preferences for the type of sedation used. The second study in the first phase was conducted to identify a sedation scale that could be used to monitor level of sedation during nurse-administered PSA in the CCL. It involved a structured literature review and psychometric analysis of scale properties. However, only one scale was found that was developed specifically for the CCL, which had not undergone psychometric testing. Several weaknesses were identified in its item structure. Other sedation scales that were identified were developed for the ICU. Although these scales have demonstrated validity and reliability in the ICU, weaknesses in their item structure precluded their use in the CCL. As findings indicated that no existing sedation scale should be applied to practice in the CCL, recommendations for the development and psychometric testing of a new sedation scale were developed. The objective of the second phase of the program of research was to explore current practice. Three studies were conducted in this phase using both quantitative and qualitative research methods. The first was a qualitative explorative study of nurses’ perceptions of the issues and challenges associated with nurse-administered PSA in the CCL. Major themes emerged from analysis of the qualitative data regarding the lack of access to anaesthetists, the limitations of sedative medications, the barriers to effective patient monitoring and the impact that the increasing complexity of procedures has on patients' sedation requirements. The second study in Phase Two was a cross-sectional survey of nurse-administered PSA practice in Australian and New Zealand CCLs. This was the first study to quantify the frequency that nurse-administered PSA was used in the CCL setting and to characterise associated nursing practices. It was found that nearly all CCLs utilise nurse-administered PSA (94%). Of note, by characterising nurse-administered PSA in Australian and New Zealand CCLs, several strategies to improve practice, such as setting up protocols for patient monitoring and establishing comprehensive PSA education for CCL nurses, were identified. The third study in Phase Two was a matched case-control study of risk factors for impaired respiratory function during nurse-administered PSA in the CCL setting. Patients with acute illness were found to be nearly twice as likely to experience impaired respiratory function during nurse-administered PSA (OR=1.78; 95%CI=1.19-2.67; p=0.005). These significant findings can now be used to inform prospective studies investigating the effectiveness of interventions for impaired respiratory function during nurse-administered PSA in the CCL. The objective of the third and final phase of the program of research was to develop recommendations for practice. To achieve this objective, a synthesis of findings from the previous phases of the program of research informed a modified Delphi study, which was conducted to develop a set of clinical practice guidelines for nurse-administered PSA in the CCL. The clinical practice guidelines that were developed set current best practice standards for pre-procedural patient assessment and risk screening practices as well as the intra and post-procedural patient monitoring practices that nurses who administer PSA in the CCL should undertake in order to deliver safe, evidence-based and consistent care to the many patients who undergo procedures in this setting. In summary, the mixed methods approach that was used clearly enabled the research objectives to be comprehensively addressed in an informed sequential manner, and, as a consequence, this thesis has generated a substantial amount of new knowledge to inform and support nurse-led sedation practice in the CCL context. However, a limitation of the research to note is that the comprehensive appraisal of the evidence conducted, combined with the guideline development process, highlighted that there were numerous deficiencies in the evidence base. As such, rather than being based on high-level evidence, many of the recommendations for practice were produced by consensus. For this reason, further research is required in order to ascertain which specific practices result in the most optimal patient and health service outcomes. Therefore, along with necessary guideline implementation and evaluation projects, post-doctoral research is planned to follow up on the research gaps identified, which are planned to form part of a continuing program of research in this field.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sedation scales have the potential to facilitate effective procedural sedation and analgesia in the cardiac catheterization laboratory (CCL). For this potential to become realised, a scale that is suitable for use in the CCL either needs to be identified or developed. To identify sedation scales, a review of Medline and CINHAL was conducted. One sedation scale for the CCL, the NASPE SED, and 15 Intensive Care Unit (ICU) scales met the inclusion and exclusion criteria. Analysis of the scale’s item structures and psychometric properties was then performed. None of these scales were deemed suitable for use in the CCL. As such, further research is required to develop a new scale. The new scale should consist of more than one item because it will be the most effective for tracking the patient’s response to medications. Specific tests required to conduct a rigorous evaluation of the new scale’s psychometric properties are outlined in this paper.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The quality of sedation management in mechanically ventilated patients has been a source of concern in recent years. This paper summarises the literature on the principles of optimal sedation, discusses the consequences of over and undersedation, highlighting the importance of appropriate pain management, and presents a case study using the results of an audit of 48 mechanically ventilated adults. As a result of the review and audit, we are implementing changes to practice.

The most important recommendations from the literature are the use of a sedation scale, setting of a goal sedation score, appropriate pain management and implementation of a nurse initiated sedation algorithm. Other recommendations include use of bolus rather than continuous sedative infusions and recommencing regular medications for anxiety, depression and other phychiatric disorders as soon as possible. A recommendation arising from our audit was the need to identify patients at high risk of oversedation and undersedation and adopt a proactive rather than reactive approach to management. The practice goal is to provide adequate and appropriate analgesia and anxiolysis for patients. This will improve patient comfort while reducing length of mechanical ventilation and minimising risk of complications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Sedation protocols, including the use of sedation scales and regular sedation stops, help to reduce the length of mechanical ventilation and intensive care unit stay. Because clinical assessment of depth of sedation is labor-intensive, performed only intermittently, and interferes with sedation and sleep, processed electrophysiological signals from the brain have gained interest as surrogates. We hypothesized that auditory event-related potentials (ERPs), Bispectral Index (BIS), and Entropy can discriminate among clinically relevant sedation levels. METHODS: We studied 10 patients after elective thoracic or abdominal surgery with general anesthesia. Electroencephalogram, BIS, state entropy (SE), response entropy (RE), and ERPs were recorded immediately after surgery in the intensive care unit at Richmond Agitation-Sedation Scale (RASS) scores of -5 (very deep sedation), -4 (deep sedation), -3 to -1 (moderate sedation), and 0 (awake) during decreasing target-controlled sedation with propofol and remifentanil. Reference measurements for baseline levels were performed before or several days after the operation. RESULTS: At baseline, RASS -5, RASS -4, RASS -3 to -1, and RASS 0, BIS was 94 [4] (median, IQR), 47 [15], 68 [9], 75 [10], and 88 [6]; SE was 87 [3], 46 [10], 60 [22], 74 [21], and 87 [5]; and RE was 97 [4], 48 [9], 71 [25], 81 [18], and 96 [3], respectively (all P < 0.05, Friedman Test). Both BIS and Entropy had high variabilities. When ERP N100 amplitudes were considered alone, ERPs did not differ significantly among sedation levels. Nevertheless, discriminant ERP analysis including two parameters of principal component analysis revealed a prediction probability PK value of 0.89 for differentiating deep sedation, moderate sedation, and awake state. The corresponding PK for RE, SE, and BIS was 0.88, 0.89, and 0.85, respectively. CONCLUSIONS: Neither ERPs nor BIS or Entropy can replace clinical sedation assessment with standard scoring systems. Discrimination among very deep, deep to moderate, and no sedation after general anesthesia can be provided by ERPs and processed electroencephalograms, with similar P(K)s. The high inter- and intraindividual variability of Entropy and BIS precludes defining a target range of values to predict the sedation level in critically ill patients using these parameters. The variability of ERPs is unknown.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose We hypothesized that reduced arousability (Richmond Agitation Sedation Scale, RASS, scores −2 to −3) for any reason during delirium assessment increases the apparent prevalence of delirium in intensive care patients. To test this hypothesis, we assessed delirium using the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and Intensive Care Delirium Screening Checklist (ICDSC) in intensive care patients during sedation stops, and related the findings to the level of sedation, as assessed with RASS score. Methods We assessed delirium in 80 patients with ICU stay longer than 48 h using CAM-ICU and ICDSC during daily sedation stops. Sedation was assessed using RASS. The effect of including patients with a RASS of −2 and −3 during sedation stop (“light to moderate sedation”, eye contact less than 10 s or not at all, respectively) on prevalence of delirium was analyzed. Results A total of 467 patient days were assessed. The proportion of CAM-ICU-positive evaluations decreased from 53 to 31 % (p < 0.001) if assessments from patients at RASS −2/−3 (22 % of all assessments) were excluded. Similarly, the number of positive ICDSC results decreased from 51 to 29 % (p < 0.001). Conclusions Sedation per se can result in positive items of both CAM-ICU and ICDSC, and therefore in a diagnosis of delirium. Consequently, apparent prevalence of delirium is dependent on how a depressed level of consciousness after sedation stop is interpreted (delirium vs persisting sedation). We suggest that any reports on delirium using these assessment tools should be stratified for a sedation score during the assessment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To examine the effect of an algorithm-based sedation guideline developed in a North American intensive care unit (ICU) on the duration of mechanical ventilation of patients in an Australian ICU. The intervention was tested in a pre-intervention, post-intervention comparative investigation in a 14-bed adult intensive care unit. Adult mechanically ventilated patients were selected consecutively (n =322) The pre-intervention and post-intervention groups were similar except for a higher number of patients with a neurological diagnosis in the pre-intervention group. An algorithm-based sedation guideline including a sedation scale was introduced using a multifaceted implementation strategy. The median duration of ventilation was 5.6 days in the post-intervention group, compared with 4.8 days for the pre-intervention group (P = 0.99). The length of stay was 8.2 days in the post-intervention group versus 7.1 days in the pre-intervention group (P = 0.04). There were no statistically significant differences for the other secondary outcomes, including the score on the Experience of Treatment in ICU 7 item questionnaire, number of tracheostomies and number of self-extubations. Records of compliance to recording the sedation score during both phases revealed that patients were slightly more deeply sedated when the guideline was used. The use of the algorithm-based sedation guideline did not reduce duration of mechanical ventilation in the setting of this study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Paediatric intensive care is an expanding specialty that has been shown to improve the quality of care provided to critically ill children. An important aspect of the management of critically ill children includes the provision of effective sedation to reduce stress and anxiety during their stay in intensive care. However, to achieve effective and safe sedation in these children, is recognised as a challenge that is not without risk. Often children receive too much or too little sedation resulting in over sedation or under sedation respectively. These problems have arisen owing to a lack of information regarding altered pharmacokinetics and pharmacodynamics of medicines administered to critically ill children. In addition there are few validated sedation scoring systems in practice with which to monitor level of sedation and titrate medication appropriately. This study consisted of two stages. Stage 1 investigated the reproducibility and practicality of two observational sedation assessment scales for use in critically ill children. The two scales were different in design, the first being simple in design requiring a single assessment of the patient. The second was more complex in design requiring assessment of five patient parameters to obtain an overall sedation score. Both scales were found to achieve good reproducibility (kappa values 0.50 and 0.62 respectively). Practicality of each sedation scale was undertaken by obtaining nursing staff opinion about both scales using questionnaire and interview technique. It was established that nursing staff preferred the second, more complex sedation scale mainly because it was perceived to give a more accurate assessment of level of sedation and anxiety rather than merely level of sedation. Stage 2 investigated the pharmacokinetics and pharmacodynamics of midazolam in critically ill children. 52 children, aged between 0 and 18 years were recruited to the study and 303 blood samples taken to analyse midazolam and its metabolites, I-hydroxyrnidazolam (I-OR) and 4-hydroxymidazolam (4-0H). Analysis of plasma was undertaken using high performance liquid chromatography. A significant correlation was found between midazolam plasma concentration and sedative effect (r=0.598, p=O.OI). It was found that a midazolam plasma concentration of 223ng/ml (±31.9) achieved a satisfactory level of sedation. Only a poor correlation was found between dose of midazolam and plasma concentration of midazolam. Similarly only a poor correlation was found between sedative effect and dose of midazolam. Clearance of midazolam was found to be 6.3mllkglmin (±0.36), which is lower than that reported in healthy children (9.Il-13.3mllkg/min). Age related differences in midazolam clearance were observed in the study. Neonates produced the lowest clearance values (l.63mllkg/min), compared to children aged 1 to 12 months (8.52mllkg/min) who achieved the highest clearance values. Clearance was found to decrease after the age of 12 months to values of 5.34mllkglmin in children aged 7 years and above. Patients with renal (n=5) and liver impairment (n~4) were found to have reduced midazolam clearance (1.37 and 0.74ml/kg/min respectively). Plasma concentrations of I-OH and 4-0H ranged from 0-5 1 89nglml and 0-27 Inglml respectively. All children were found to be capable of producing both metabolites irrespective of age, although no trend was established between age and extent of production of either metabolite. Disease state was found to affect production of l-OH. Patients with renal impairment (n=5) produced the lowest I-OH midazolam plasma ratio (0.059) compared to patients with head injury (0.858). Patients with severe liver impairment were found to be capable of manufacturing both metabolites despite having a severely damaged liver.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background. Excessive sedation is associated with adverse patient outcomes during critical illness, and a validated monitoring technology could improve care. We developed a novel method, the responsiveness index (RI) of the frontal EMG. We compared RI data with Ramsay clinical sedation assessments in general and cardiac intensive care unit (ICU) patients. Methods. We developed the algorithm by iterative analysis of detailed observational data in 30 medical–surgical ICU patients and described its performance in this cohort and 15 patients recovering from scheduled cardiac surgery. Continuous EMG data were collected via frontal electrodes and RI data compared with modified Ramsay sedation state assessments recorded regularly by a blinded trained observer. RI performance was compared with EntropyTM across Ramsay categories to assess validity. Results. RI correlated well with the Ramsay category, especially for the cardiac surgery cohort (general ICU patients r¼0.55; cardiac surgery patients r¼0.85, both P,0.0001). Discrimination across all Ramsay categories was reasonable in the general ICU patient cohort [PK¼0.74 (SEM 0.02)] and excellent in the cardiac surgery cohort [PK¼0.92 (0.02)]. Discrimination between ‘lighter’ vs ‘deeper’ (Ramsay 1–3 vs 4–6) was good for general ICU patients [PK¼0.80 (0.02)] and excellent for cardiac surgery patients [PK¼0.96 (0.02)]. Performance was significantly better than EntropyTM. Examination of individual cases suggested good face validity. Conclusions. RI of the frontal EMG has promise as a continuous sedation state monitor in critically ill patients. Further investigation to determine its utility in ICU decision-making is warranted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: To describe the positioning of patients managed in an intensive care unit (ICU); assess how frequently these patients were repositioned; and determine if any specific factors influenced how, why or when patients were repositioned in the ICU. Background: Alterations in body position of ICU patients are important for patient comfort and are believed to prevent and/or treat pressure ulcers, improve respiratory function and combat the adverse effects of immobility. There is a paucity of research on the positioning of critically ill patients in Saudi Arabian ICUs. Design and Methods: A prospective observational study was undertaken. Participant demographic data were collected as were clinical factors (i.e. ventilation status, primary diagnosis, co-morbidities and Ramsay sedation score) and organizational factors (i.e. time of day, type of mattress or beds used, nurse/patient ratio and the patient's position). Clinical and some organization data were recorded over a continuous 48 hour period. Result: Twenty-eight participants were recruited to the study. No participant was managed in either a flat or prone position. Obese participants were most likely to be managed in a supine position. The mean time between turns was two hours. There was no significant association between the mean time between turns and the recorded variables related to patients' demographic and organizational considerations. Conclusion: Results indicate that patient positioning in the ICU was a direct result of unit policy - it appeared that patients were not repositioned based upon evaluation of their clinical condition but rather according to a two-hour ICU timetable

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En la unidad de cuidado intensivo pediátrico (UCIP) es esencial garantizar una adecuada sedación y analgesia del paciente en ventilación mecánica para mejorar su adaptación, disminuyendo el estrés y ansiedad de la situación crítica. Una estrategia utilizada es la combinación de midazolam más fentanyl, sin embargo no se encuentra en la literatura estudios sobre la repercusión de la forma de preparación sobre los grados de sedación, objetivo principal de este estudio. Materiales y métodos: Se realizó un estudio analítico retrospectivo para evaluar las diferencias sobre la escala Comfort de sedación con dos medicamentos: fentanyl y midazolam diluidos en solución salina y sin diluir. Se revisaron 1321 historias clínicas desde enero del 2005 a junio del 2010; 70 cumplieron con los criterios de inclusión y se agruparon en 2 cohorte. La cohorte No 1 fueron los pacientes que recibieron medicamentos puros y la cohorte 2 aquellos que los recibieron diluidos en solución salina. Se hizo un análisis estadístico mediante chi cuadrado y regresión logística. Resultados: Se encontró una diferencia estadísticamente significativa a favor de medicamentos sin diluir en términos de grado de “sedación óptima” (p< 0.01). No hubo diferencias al evaluar tiempo de estancia en UCIP (p=0.67), duración de ventilación mecánica (p=0.15), número de medicamentos coadyuvantes utilizados (p=0.1) ni de la frecuencia de presentación del síndrome de abstinencia (p=0.77). Conclusión: Se encontró una diferencia en el número de pacientes que alcanzaron el puntaje óptimo en la escala Comfort utilizando la estrategia de sedación con medicamentos preparados sin diluir.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: La escala LLANTO para dolor es una escala que hasta la fecha ha sido solo validada en población infantil española, actualmente no se conocen datos en población colombiana. Se pretende validar la escala de dolor LLANTO en pacientes neonatos y menores de 5 años, a través de su aplicación en pacientes atendidos en una de tres instituciones, además comparándola con las escalas FLACC y PIPP dependiendo de edad del paciente. Metodología: Se incluyeron niños con cualquier tipo de dolor, clasificándolos en dos grupos por edad: 1) neonatos y 2) niños entre 1 mes y 5 años de edad, que asistieron a la Fundación Cardioinfantil, Clínica Infantil Colsubsidio o al Hospital Universitario Mayor. Las escalas fueron aplicadas por dos residentes de pediatría y una enfermera especializada en el cuidado de población infantil. Para la prueba piloto se diseñó un cuestionario determinar dificultades en la aplicación de la escala LLANTO. Una vez corregidos los problemas identificados se procederá a la validación de la escala. Resultados: Se presentan los datos de la prueba piloto. Se incluyeron 8 neonatos y 8 niños entre 1 mes y 5 años, esta muestra fue obtenida en un periodo de un mes, con la encuesta se evaluó la aceptación y entendimiento de la escala LLANTO por parte de los evaluadores. La prueba piloto mostró resultados favorables en el 100% de los encuestados. Discusión: Se considera que la escala LLANTO no requiere cambios para continuar con su validación.