863 resultados para pupil filter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combining differential confocal microscopy and an annular pupil filter, we obtained the normalized axial intensity distribution curve of an optical system. We used the sharp slopes of the axial response curve of the optical system to measure the surface profile of a reflection grating. Experimental results prove that this method can extend the axial dynamic range and improve the transverse resolution of three-dimensional profilometry by sacrificing axial resolution. (C) 2000 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new method for designing three-zone optical pupil filter is presented. The phase-only optical pupil filter and the amplitude-only optical pupil filters were designed. The first kind of pupil for optical data storage can increase the transverse resolution. The second kind of pupil filter can increase the axial and transverse resolution at the same time, which is applicable in three-dimension imaging in confocal microscopy. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate that it is possible to reduce the focal spot size by inserting a uniform nonlinear thin film at the aperture of a focusing lens. The reduction of spot size is tunable by adjusting the incoming laser power. In comparison with the original diffraction spot, the transverse spot size can be reduced 0.65 times. The nonlinear thin film acts effectively as a Toraldo filter, and the phase and amplitude modulation stems from the laser-induced variances in the transmission of the thin film. The proposed technique removes the need of fabricating annular pupil filters. (C) 2008 Optical Society of America.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper an electrically controllable radial birefringent pupil filter is proposed. It consists of two polarizers and an improved electrically controllable optical azimuth rotator which has two lambda/4 retarders, one electro-optical crystal and one radial birefringent crystal. The evolution and distribution of polarization states of this pupil filter are discussed. The most interesting and useful advantage of such a structure is that the characteristic of transverse superresolution and axial extended focal depth or focal shift can be obtained merely by controlling the applied voltage on the electro-optical crystal. The radial birefringent crystal azimuth angle cooperating with different electrical inductive phase differences will determine the transverse and axial intensity distribution. It is shown that for particular ranges of electrical inductive phase difference it is possible to obtain transverse superresolution along with extended focal depth or with a focal shift.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

基于双折射波片的特性,提出了一种具有双调节模式的连续可调超分辨光瞳滤波器。该滤波器通过两种调节模式实现超分辨,且在一定范围内连续可调。在横向旋转模式下,该滤波器为复振幅型光瞳滤波器,纵向倾斜模式下为纯相位型超分辨滤波器。通过对超分辨参量的分析,得到最佳设计参量,可以实现大的视场角,大的超分辨范围、高的调节精度。这种滤波器为实际应用提供了更多的方便。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A two-mode adjustable superresolving filter based on a birefringent filter is proposed. This kind of filter has superresolution in two modes of adjustment. One is rotation of the binary pupil filter on the optical axis of the system and the other is the tilt of the filter away from the pupil plane on axis parallel or perpendicular to the optical axis of the crystal. The filters act as complex amplitude filters in the former mode, and as pure phase filters in the latter. By analyzing two superresolving parameters, we obtain the optimal design parameters that ensure a large field of view, a large superresolving range, and a high setting accuracy. This kind of filter can provide more flexibility in practical applications. (c) 2006 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

光瞳滤波器作为实现超分辨的基本元件之一,它的设计以及制作都非常重要。设计了一种正弦变化的振幅型光瞳滤波器,可以通过调节少量的参量实现各种不同的超分辨模式。选择正弦函数的周期以及光瞳中心点透过率变化两个参量来实现对最终超分辨效果的调节。数值计算结果表明:在整个人射光瞳上的透过率瞳函数分布具有0.5~2个正弦振幅周期时,较为合适。小于0.5个周期将不会有任何超分辨效果,大于2个周期超分辨效果反而变差。数值计算中还注意到,当周期数为整数时,斯特雷尔比将保持0.25不变。对正弦变化振幅型光瞳滤波器的计算结果,显示

Relevância:

60.00% 60.00%

Publicador:

Resumo:

星间激光通讯中,精跟踪起着十分重要的作用,而精密偏转镜(FSM)是精跟踪系统中最为关键的部件.基于光学矢量反射定律,推导得到了FSM的精确光学特性,这一特性为精跟踪控制系统提供了精确的理论依据.设计了基于FSM精确光学特性的精跟踪控制系统,对系统整定所用的单纯形法进行了两点重要改进,并对所设计的精跟踪系统进行了数字模拟,由此实现了对FSM的精确控制,提高了精跟踪系统的精确性;将光学衍射超分辨原理应用到星间激光通讯中.利用三区位相光瞳滤波器的超分辨性能,改变光学系统的点扩散函数,从而改变接收端焦平面上的光强

Relevância:

60.00% 60.00%

Publicador:

Resumo:

超分辨技术中现有的纯振幅型或纯相位型光瞳滤波器,大部分只能实现轴向或横向超分辨而不能实现三维超分辨,三维超分辨在三维成像系统中有着重要的作用。因此为提高成像系统中的三维分辨能力,设计了一种复振幅光瞳滤波器,并对其三维超分辨性能进行了研究。详细分析了该光瞳滤波器的第一区半径和透射率对施特雷尔比、轴向和横向超分辨因子以及旁瓣能量的影响。通过一系列的模拟证明,借助于复振幅光瞳滤波器可以实现三维超分辨。该滤波器的优点是容易实现三维超分辨,且有比较高的施特雷尔比,缺点是三维超分辨的实现总是伴随着旁瓣能量的增加,但可

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The bipolar point spread function (PSF) corresponding to the Wiener filter tor correcting linear-motion-blurred pictures is implemented in a noncoherent optical processor. The following two approaches are taken for this implementation: (1) the PSF is modulated and biased so that the resulting function is non-negative and (2) the PSF is split into its positive and sign-reversed negative parts, and these two parts are dealt with separately. The phase problem associated with arriving at the pupil function from these modified PSFs is solved using both analytical and combined analytical-iterative techniques available in the literature. The designed pupil functions are experimentally implemented, and deblurring in a noncoherent processor is demonstrated. The postprocessing required (i.e., demodulation in the first approach to modulating the PSF and intensity subtraction in the second approach) are carried out either in a coherent processor or with the help of a PC-based vision system. The deblurred outputs are presented.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method of eye localisation and face segmentation for use in a face recognition system. By using two near infrared light sources, we have shown that the face can be coarsely segmented, and the eyes can be accurately located, increasing the accuracy of the face localisation and improving the overall speed of the system. The system is able to locate both eyes within 25% of the eye-to-eye distance in over 96% of test cases.