938 resultados para prosthesis and implants
Resumo:
This clinical report describes a method to reduce the number of clinical sessions for the rehabilitation of implant-supported fixed dentures through a simplified and versatile procedure indicated mainly for immediate loading. According to this method, the immediate implant-supported fixed dentures for edentulous patients can be safely fabricated within 2 days. In this technique, the teeth in the wax are prepared on a base of light-polymerized resin, and both wax teeth and metallic superstructure trials are accomplished at the same session.
Resumo:
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.
Resumo:
Here, we present a case report on prosthetic reconstruction of posterior teeth and composite resin restoration of anterior teeth yielding considerable esthetic improvement, reestablishment of disocclusion guides and function.
Resumo:
The present article discusses an atrophic maxilla reconstruction with iliac crest bone block and particulate grafts and dental implants. Onlay block grafts were used to restore bone volume of the anterior maxilla, whereas bilateral sinus floor augmentation was performed using a particulate graft. Ten months after the grafting surgery, 9 dental implants were placed to rehabilitate the case. Results of a 7-year follow-up were obtained clinically and by cone beam computed tomographic images.
Resumo:
The role of and interaction between bacterial infection and biomechanical impact in the development of peri-implant inflammatory processes is not clear.
Resumo:
PURPOSE: In the present cohort study, overdentures with a combined root and implant support were evaluated and compared with either exclusively root- or implant-supported overdentures. Results of a 2-year follow-up period are reported, namely survival of implants, root copings, and prostheses, plus prosthetic complications, maintenance service, and patient satisfaction. MATERIALS AND METHODS: Fourteen patients were selected for the combined overdenture therapy and were compared with 2 patient groups in which either roots or implants provided overdenture support. Altogether, 14, 17, and 15 patients (in groups 1, 2, and 3, respectively) were matched with regard to age, sex, treatment time, and observation period. The mean age was around 67 years. Periodontal parameters were recorded, radiographs were taken, and all complications and failures were registered during the entire observation time. The patients answered a 9-item questionnaire by means of a visual analogue scale (VAS). RESULTS: One implant failed and 1 tooth root was removed following longitudinal root fracture. Periodontal/peri-implant parameters gave evidence of good oral hygiene for roots and implants, and slight crestal bone resorption was measured for both. Technical complications and service performed were significantly higher in the first year (P < .04) in all 3 groups and significantly higher in the tooth root group (P < .03). The results of the VAS indicated significantly lower scores for satisfaction, speaking ability, wearing comfort, and denture stability with combined or exclusive root support (P < .05 and .02, respectively). Initial costs of overdentures with combined or root support were 10% lower than for implant overdentures. CONCLUSION: The concept of combined root and implant support can be integrated into treatment planning and overdenture design for patients with a highly reduced dentition.
Resumo:
This case series reports on the use of nonsilica-based high-strength full ceramics for different prosthetic indications. Fifty-two consecutive patients received tooth- or implant-supported zirconia reconstructions during a 2-year period. The observation period for reexamination was 12 to 30 months. The most frequent indications were single crowns and short-span fixed partial dentures. A few implant superstructures were screw-retained, whereas all remaining restorations were cemented on natural teeth or zirconia implant abutments. Clinical examination included biologic (probing depths, bleeding on probing) and esthetic (Papilla Index) parameters, as well as technical complications. No implant was lost or caused any problems, but two teeth were lost after horizontal fracture. Overall, the periodontal parameters were favorable. Fractures of frameworks or implant abutments were not observed. Abutment-screw loosening occurred once for one premolar single crown. Furthermore, five implant crowns in the posterior region exhibited chipping of the porcelain veneering material. With regard to esthetics, no reconstructions were considered unacceptable, but three crowns were remade shortly after delivery. In this short-term study, it was observed that biologic, esthetic, and mechanical properties of zirconia were favorable, and the material could be used in various prosthetic indications on teeth or implants.
Resumo:
BACKGROUND Limited data exist on the longitudinal crestal bone changes around teeth compared with implants in partially edentulous patients. This study sought to compare the 10-year radiographic crestal bone changes (bone level [BL]) around teeth and implants in periodontally compromised (PCPs) and periodontally healthy (PHPs) patients. METHODS A total of 120 patients were evaluated for the radiographic crestal BL around dental implants and adjacent teeth at time of implant crown insertion and at the 10-year follow-up. Sixty patients had a previous history of periodontitis (PCPs), and the remaining 60 were PHPs. In each category (PCP and PHP), two different implant systems were used. The mean BL change at the implant and at the adjacent tooth at the interproximal area was calculated by subtracting the radiographic crestal BL at the time of crown cementation from the radiographic crestal BL at the 10-year follow-up. RESULTS At 10 years after therapy, the survival rate ranged from 80% to 95% for subgroups for implants, whereas it was 100% for the adjacent teeth. In all eight different patient categories evaluated, teeth demonstrated a significantly more stable radiographic BL compared with adjacent dental implants (teeth BL, 0.44 ± 0.23 mm; implant BL, 2.28 ± 0.72 mm; P <0.05). Radiographic BL changes around teeth seemed not to be influenced by the presence or absence of advanced bone loss (≥3 mm) at the adjacent implants. CONCLUSIONS Natural teeth yielded better long-term results with respect to survival rate and marginal BL changes compared with dental implants. Moreover, these findings also extend to teeth with an initial reduced periodontal attachment level, provided adequate periodontal treatment and maintenance are performed. As a consequence, the decision of tooth extraction attributable to periodontal reasons in favor of a dental implant should be carefully considered in partially edentulous patients.
Resumo:
OBJECTIVE To determine the microbiota at implants and adjacent teeth 10 years after placement of implants with a sandblasted and acid-etched surface. MATERIAL AND METHODS Plaque samples obtained from the deepest sites of 504 implants and of 493 adjacent teeth were analyzed for certain bacterial species associated with periodontitis, for staphylococci, for aerobic gram-negative rods, and for yeasts using nucleic acid-based methods. RESULTS Species known to be associated with periodontitis were detectable at 6.2-78.4% of the implants. Significantly higher counts at implants in comparison with teeth were assessed for Tannerella forsythia, Parvimonas micra, Fusobacterium nucleatum/necrophorum, and Campylobacter rectus. Higher counts of periodontopathogenic species were detectable at implants of current smokers than at those of non-smokers. In addition, those species were found in higher quantities at implants of subjects with periodontitis. The prevalence of Prevotella intermedia, Treponema denticola, C. rectus, and moreover of Staphylococcus warneri might be associated with peri-implant inflammation. Selected staphylococcal species (not Staphylococcus aureus), aerobic gram-negative rods, and yeasts were frequently detected, but with the exception of S. warneri, they did not show any association with periodontal or peri-implant diseases. CONCLUSIONS Smoking and periodontal disease are risk factors for colonization of periodontopathic bacteria at implants. Those bacterial species may play a potential role in peri-implant inflammation. The role of S. warneri needs further validation.
Resumo:
OBJECTIVES To assess a selection of host-derived biomarkers in peri-implant sulcus fluid (PISF) and gingival crevicular fluid (GCF) from adjacent teeth 10 years following implant placement. MATERIAL AND METHODS Peri-implant sulcus fluid and GCF samples obtained from the deepest sites of 504 implants and 493 adjacent teeth were analysed for levels of interleukin (IL)-1β, matrix metalloproteinase (MMP)-3, MMP-8, MMP-1, and MMP-1 bound to tissue inhibitor of MMP (TIMP)-1 (MMP-1/TIMP-1) by enzyme-linked immunosorbent assay (ELISA) technique. RESULTS Overall, MMP-8 was detected in 90% of the sites. In more than 50% of the sites, IL-1β was identified while in 30% of the sites MMP-1, MMP-1/TIMP-1 and MMP-3 were found over the detection level. Increased biomarkers levels from PISF and GCF were positively correlated (r = 0.375-0.702; P < 0.001). However, no qualitative and quantitative differences were found between PISF and GCF. The levels of MMP-1 were negatively correlated with those of MMP-1/TIMP-1 at implants (r = -0.644; P < 0.001). Median MMP-1 levels at implants were high (5.17 pg/site) in subjects with severe chronic periodontitis and low in patients with mild-to-moderate chronic periodontitis (0 pg/site; P = 0.026) or gingivitis (0 pg/site; P = 0.034). Levels of IL-1β were found to be different in GCF according to the periodontal conditions (P = 0.001) with the highest level found in mild-to-moderate periodontitis (6.2 pg/site). Clinical attachment levels at implants demonstrated an inverse correlation with MMP-1/TIMP-1 (r = -0.147; P = 0.001). CONCLUSIONS Increased levels of MMP-8 and IL-1β in PISF or GCF may be associated with inflammation around teeth and implants while lower levels of MMP-1/TIMP-1 may be an indicator of disease progression around implants.
Resumo:
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.
Resumo:
An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.