10 resultados para prefilled


Relevância:

10.00% 10.00%

Publicador:

Resumo:

objective. To describe the management of patients with long-term central venous catheters (CVCs) during an outbreak of infection due to Pseudomonas putida and Stenotrophomonas maltophilia associated with contaminated heparin catheter-lock solution. design. Descriptive study. setting. Private, 250-bed tertiary-care hospital. methods. In March 2003, we identified 2 febrile cancer patients with P. putida bacteremia. Over 2 days, 7 cases of bacteremia were identified; lots of syringes prefilled with heparin catheter-lock solution, supplied by a compounding pharmacy, were recalled and samples were cultured. More cases of bacteremia appeared during the following days, and any patient who had had a catheter lock infused with the suspect solution was asked to provide blood samples for culture, even if the patient was asymptomatic. Isolates that were recovered from culture were typed by pulsed-field gel electrophoresis. Antimicrobial salvage treatment of long-term CVCs was attempted. results. A total of 154 patients had had their catheter lock infused with solution from the lots that were suspected of being contaminated. Only 48 of these patients had CVCs. By day 7 of the outbreak, 18 of these patients had become symptomatic. Twenty-six of the remaining 30 asymptomatic patients then also provided blood samples for culture, 10 of whom developed fever shortly after samples were collected. Thirty-two patients were identified who had P. putida bacteremia; 9 also had infection due to S. maltophilia. Samples from 1 of the 3 lots of prefilled syringes in use at the time of the outbreak also grew P. putida on culture. Molecular typing identified 3 different clones of P. putida from patients and heparin catheter-lock solution, and 1 clone of S. maltophilia. A total of 27 patients received antimicrobial therapy regimens, some of which included decontamination of the catheter lock with anti- infective lock solution. Of 27 patients, 19 (70%) retained their long-term CVC during the 6-month follow-up period. conclusions. To our knowledge, this is one of the largest prospective experiences in the management of bloodstream infection associated with long-term CVCs. The infections were caused by gram-negative bacilli and were managed without catheter removal, with a high response rate. We emphasize the risks of using intravenous formulations of medications supplied by compounding pharmacies that produce large quantities of drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kishi D; Videira RLR Description of Nosocomial Infection Prevention Practices by Anesthesiologists in a University Hospital. Background and objectives: Anesthesiologists play an important role in the prevention of nosocomial infections. In anesthetic practice, physiologic barriers are routinely breached, allowing patient contamination with microorganisms and the consequent development of infection. The lack of adhesion to recommended practices can facilitate transmission of microorganisms. It is important to describe prophylactic practices of anesthesia-related nosocomial infections performed by anesthesiologists. Methods: Structured questionnaires were distributed to be answered voluntarily and anonymously by anesthesiologists. Results: Among 112 anesthesiologists, 75% answered the questionnaire. Surgical mask is used by 95.2% of anesthesiologists, 96.3% wear gloves frequently, 98.9% wear sterile gloves for neuraxial block, 91.3% use sterile technique for central venous puncture, 95.1% wash their hands between cases, 91.6% try to maintain the endotracheal tube sterile, 96.3% discard the prefilled propofol syringe at the end of each anesthesia, 30% clean the vials before using it in the neuraxial blocks, and 19.8% clean the vials before intravenous use. Conclusions: Respondents showed good adhesion to practices of nosocomial infection prophylaxis and to improve them educational multidisciplinary campaigns are necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Differences in physico-chemical characteristics of bone grafts to fill bone defects have been demonstrated to influence in vitro bacterial biofilm formation. Aim of the study was to investigate in vivo staphylococcal biofilm formation on different calcium phosphate bone substitutes. A foreign-body guinea-pig infection model was used. Teflon cages prefilled with β-tricalcium phosphate, calcium-deficient hydroxyapatite, or dicalcium phosphate (DCP) scaffold were implanted subcutaneously. Scaffolds were infected with 2 × 10(3) colony-forming unit of Staphylococcus aureus (two strains) or S. epidermidis and explanted after 3, 24 or 72 h of biofilm formation. Quantitative and qualitative biofilm analysis was performed by sonication followed by viable counts, and microcalorimetry, respectively. Independently of the material, S. aureus formed increasing amounts of biofilm on the surface of all scaffolds over time as determined by both methods. For S. epidermidis, the biofilm amount decreased over time, and no biofilm was detected by microcalorimetry on the DCP scaffolds after 72 h of infection. However, when using a higher S. epidermidis inoculum, increasing amounts of biofilm were formed on all scaffolds as determined by microcalorimetry. No significant variation in staphylococcal in vivo biofilm formation was observed between the different materials tested. This study highlights the importance of in vivo studies, in addition to in vitro studies, when investigating biofilm formation of bone grafts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives A pharmacy Central Intravenous Additives Service (CIVAS) provides ready to use injectable medicines. However, manipulation of a licensed injectable medicine may significantly alter the stability of drug(s) in the final product. The aim of this study was to develop a stability indicating assay for CIVAS produced dobutamine 500 mg in 50 ml dextrose 1% (w/v) prefilled syringes, and to allocate a suitable shelf life. Methods A stability indicating high performance liquid chromatography (HPLC) assay was established for dobutamine. The stability of dobutamine prefilled syringes was evaluated under storage conditions of 4°C (protected from light), room temperature (protected from light), room temperature (exposed to light) and 40°C (protected from light) at various time points (up to 42 days). Results An HPLC method employing a Hypersil column, mobile phase (pH=4.0) consisting of 82:12:6 (v/v/v) 0.05 M KH2PO4:acetonitrile:methanol plus 0.3% (v/v) triethylamine with UV detection at λ=280 nm was specific for dobutamine. Under different storage conditions only samples stored at 40°C showed greater than 5% degradation (5.08%) at 42 days and had the shortest T95% based on this criterion (44.6 days compared with 111.4 days for 4°C). Exposure to light also reduced dobutamine stability. Discolouration on storage was the limiting factor in shelf life allocation, even when dobutamine remained within 5% of the initial concentration. Conclusions A stability indicating HPLC assay for dobutamine was developed. The shelf life recommended for the CIVAS product was 42 days at 4°C and 35 days at room temperature when protected from light.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objectives: Glass ampoules have been widely used in packaging injection drugs. Glass has important characteristics that allow it to be widely used in fabrication of recipients for drugs and other sterile substances. However, contamination of solutions with glass microparticles on breaking open glass ampoules, the presence of metals, percutaneous injury, and biological contamination justify the need of educational materials to orient the manipulation of ampoules. Contents: Glass microparticles generated in the snap-opening of ampoules, as well as metals that contaminate their contents can be aspirated and injected through several routes. Exogenous contaminations by glass and metals can reach several sites in the organism. They trigger organic reactions that may give rise to injuries. Opening ampoules can expose professionals to the risk of percutaneous injuries. These lesions increase the biological risk as they are the gateway for viruses and bacteria. Ampoules opening systems (VIBRAC and OPC) have been developed to reduce the incidence of such accidents. Alternative materials to glass may represent an interesting strategy to increase safety. The use of prefilled syringes may represent an evolution regarding safety. Conclusions: Team training and information provided by the pharmaceutical industry on the use of ampoules are fundamental in the prophylaxis of accidents and contaminations. The search for safer materials to replace glass is also important. © 2011 Elsevier Editora Ltda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Decompressive laparotomy followed by temporary abdominal closure (TAC) is an established prophylaxis and treatment for abdominal compartment syndrome. The herein presented study aimed at the comparison of volume reserve capacity and development of intra-abdominal hypertension after forced primary abdominal closure and different TAC techniques in a porcine model. METHODS: Eight anesthesized and mechanically ventilated domestic pigs underwent a standardized midline laparotomy. A bag was placed into the abdominal cavity. Before abdominal closure, the bag was prefilled with 3,000 mL water to simulate increased intra-abdominal volume. The intra-abdominal pressure (IAP) was then increased in 2 mm Hg steps up to 30 mm Hg by adding volume (volume reserve capacity) to the intra-abdominal bag. Volume reserve capacity with the corresponding IAP were analyzed and compared for primary abdominal closure, bag silo closure, a zipper system, and vacuum-assisted closure (VAC) with different negative pressures (-50, -100, and -150 mm Hg). Hemodynamic and pulmonary parameters were monitored throughout the experiment. RESULTS: Volume reserve capacity was the highest for bag silo closure followed by the zipper system and VAC with primary abdominal closure providing the least volume reserve capacity in the whole IAP range. Of interest, VAC -50 mm Hg resulted in a lower volume reserve capacity when compared with VAC -100 and -150 mm Hg. Pulmonary and hemodynamic parameters demonstrated no significant differences between primary abdominal closure and the evaluated TAC techniques at all IAP levels. CONCLUSIONS: The present experimental in vivo study indicates that bag silo closure and zipper systems may be favorable TAC techniques after decompressive laparotomy. In contrast, the VAC techniques resulted in lower volume reserve capacity and therefore may bear an increased risk for recurrent intra-abdominal hypertension in the initial phase after decompressive laparotomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report automated DNA sequencing in 16-channel microchips. A microchip prefilled with sieving matrix is aligned on a heating plate affixed to a movable platform. Samples are loaded into sample reservoirs by using an eight-tip pipetting device, and the chip is docked with an array of electrodes in the focal plane of a four-color scanning detection system. Under computer control, high voltage is applied to the appropriate reservoirs in a programmed sequence that injects and separates the DNA samples. An integrated four-color confocal fluorescent detector automatically scans all 16 channels. The system routinely yields more than 450 bases in 15 min in all 16 channels. In the best case using an automated base-calling program, 543 bases have been called at an accuracy of >99%. Separations, including automated chip loading and sample injection, normally are completed in less than 18 min. The advantages of DNA sequencing on capillary electrophoresis chips include uniform signal intensity and tolerance of high DNA template concentration. To understand the fundamentals of these unique features we developed a theoretical treatment of cross-channel chip injection that we call the differential concentration effect. We present experimental evidence consistent with the predictions of the theory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential for microbial contamination associated with a recently developed needleless closed luer access device (CLAD) (Q-Syte™ Becton Dickinson, Sandy, UT, USA) was evaluated in vitro. Compression seals of 50 multiply activated Q-Syte devices were inoculated with Staphylococcus epidermidis NCTC 9865 in 25% (v/v) human blood and then disinfected with 70% (v/v) isopropyl alcohol followed by flushing with 0.9% (w/v) sterile saline. Forty-eight of 50 (96%) saline flushes passed through devices that had been activated up to a maximum of 70 times remained sterile. A further 25 Q-Syte CLADs that had undergone multiple activations were challenged with prefilled 0.9% (w/v) sterile saline syringes, the external luer tips of which had been inoculated with S. epidermidis NCTC 9865 prior to accessing the devices. None of the devices that had been accessed up to 70 times allowed passage of micro-organisms, despite challenge micro-organisms being detected on both the syringe tip after activation and the compression seals before decontamination. These findings suggest that the Q-Syte CLAD may be activated up to 70 times with no increased risk of microbial contamination within the fluid pathway. The device may also offer protection from the external surface of syringe tips contaminated with micro-organisms. © 2005 Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To compare and examine the storage stability of compounded bevacizumab in polycarbonate (PC) and polypropylene (PP) syringes over a 6-month period. PC syringes have been used in a recent clinical study and bevacizumab stability has not been reported for this type of syringe. Methods Repackaged bevacizumab was obtained from Moorfields Pharmaceuticals in polycarbonate (PC) and polypropylene (PP) syringes. Bevacizumab from the stored syringes was analysed at monthly time points for a 6-month period and compared with bevacizumab from a freshly opened vial at each time point. SDS-PAGE electrophoresis and size-exclusion chromatography (SEC) was used to observe aggregation and degradation. Dynamic light scattering (DLS) provided information about the hydrodynamic size and particle size distribution of bevacizumab in solution. VEGF binding and the active concentration of bevacizumab was determined by surface plasmon resonance (SPR) using Biacore. Results SDS-PAGE and SEC analysis did not show any changes in the presence of higher molecular species (HMWS) or degradation products in PC and PP syringes from T0 to T6 compared to bevacizumab sampled from a freshly opened vial. The hydrodynamic diameter of bevacizumab in the PC syringe after six months of storage was not significantly different to bevacizumab taken from a freshly opened vial. Using SPR, the VEGF binding activity of bevacizumab in the PC syringe was comparable with bevacizumab taken from a freshly opened vial. Conclusion No significant difference over a 6-month period was observed in the quality of bevacizumab repackaged into prefilled PC polycarbonate and PP polypropylene syringes when compared to bevacizumab that is supplied from the vial.