19 resultados para powerline


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autonomous mini-helicopters have been seen as a viable option for aerial-based powerline inspections, however there are numerous research and engineering challenges in developing a system capable of achieving this task in a dependable manner. We have developed an autonomous helicopter as a research platform which will allow us to demonstrate proof-of-concept capabilities for powerline inspections. Through numerous development cycles and from flight test experience we have gained insights into the key challenges in this area. We discuss these insights, describe the helicopter platform and present our research progress in the area of obstacle avoidance for mini-helicopters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High voltage powerlines may give rise to corona breakdown, resulting in the release of large concentrations of charged ions into the surrounding environment. These ions quickly attach to aerosols and the resulting charged particles are carried by prevalent winds. This paper describes a study carried out at a site near an overhead double circuit ac transmission voltage powerline to investigate factors that control the rate at which charged particles are produced, and to determine the total particle number concentrations, total particle charge concentrations and vertical dc electric fields in the proximity of the line. Measured mean values of these three parameters at a perpendicular distance of 50m from the line were 1.8 x 103 particle cm-3, 518 ions cm3 and 520 V m-1 respectively. The net electric charge was positive and the electric field was directed downwards. These parameters were correlated with each other and monitored at four different distances from the line. Effects of meteorological parameters such as wind speed and wind direction were also investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following paper presents a Powerline Communication (PLC) Method for grid interfaced inverters, for smart grid application. The PLC method is based on the concept of the composite vector which involves multiple components rotating at different harmonic frequencies. The pulsed information is modulated on the fundamental component of the grid current as a specific repeating sequence of a particular harmonic. The principle of communication is same as that of power flow, thus reducing the complexity. The power flow and information exchange are simultaneously accomplished by the interfacing inverters based on current programmed vector control, thus eliminating the need for dedicated hardware. Simulation results have been shown for inter-inverter communication, both under ideal and distorted conditions, using various harmonic modulating signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following paper presents a Powerline Communication (PLC) Method for Single Phase interfaced inverters in domestic microgrids. The PLC method is based on the injection of a repeating sequence of a specific harmonic, which is then modulated on the fundamental component of the grid current supplied by the inverters to the microgrid. The power flow and information exchange are simultaneously accomplished by the grid interacting inverters based on current programmed vector control, hence there is no need for dedicated hardware. Simulation results have been shown for inter-inverter communication under different operating conditions to propose the viability. These simulations have been experimentally validated and the corresponding results have also been presented in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Management of powerline corridors in Australia has traditionally focused on the complete removal of vegetation using short rotation times owing to the perceived hazard of fire associated with corridor vegetation. Because of the intense management associated with fire hazards, little thought has been given to use of powerline corridors by wildlife. This has resulted in corridors traditionally being viewed as a source of fragmentation and habitat loss within forested ecosystems. We investigated the responses of small mammal communities living in a powerline corridor to management-induced vegetation changes at different successional stages, to determine whether a compromise could be reached between managing corridors for fire and biodiversity. Habitat modelling in the corridor and adjacent forest for three native and one introduced small mammal species demonstrated that species responded to changes in vegetation structural complexity, rather than time-since-management per se. Early seral stages of vegetation recovery after corridor management encouraged the introduced house mouse (Mus domesticus) into corridors and contributed little to biodiversity. Mid-seral-stage vegetation, however, provided habitat for native species that were rare in adjacent forest habitats. As the structural complexity of the vegetation increased, the small mammal community became similar to that of the forest so that corridor vegetation contributed fewer biodiversity benefits while posing an unacceptable fire risk. If ecologically sensitive management regimes are implemented to encourage mid-seral vegetation and avoid complete vegetation removal, powerline corridors have the potential to improve biodiversity. This would maintain landscape connectivity and provide habitat for native species uncommon in the forest while still limiting fuel loads in the corridor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utility corridors such as powerlines are widespread linear easements of highly modified vegetation which often fragment natural areas of conservation significance. Vegetation management along these easements is aimed at modifying vegetation structure by the removal of all tall shrubs and trees, which may have adverse impacts on flora and fauna diversity. Victoria's Bunyip State Park is bisected by a high voltage powerline easement which is managed by a four year slashing cycle. Repeated slashing has altered plant species composition and structure of the drier slope and ridge vegetation compared to unslashed adjacent Open Forest vegetation, but Wet Heath within the management zone has remained largely unmodified. At a broad level, plant species diversity in the easement is increased, and higher vegetation density has created small mammal habitat. The powerline easement did not appear to facilitate weed invasion. Vegetation management by repeated slashing has altered the vegetation, but does not appear to have had adverse conservation impacts on local plant and small mammal diversity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Powerline corridor management in Australia has traditionally focused on the complete removal of vegetation using short rotation times due to the perceived fire hazard associated with corridor vegetation. This study assessed vegetation recovery in a powerline corridor, following management, at three sites spanning corridor and forest habitat. Forest and corridor vegetation communities differed significantly between sites and over time. As vegetation recovered, the corridor community became a mix of plants common in the surrounding forest and open areas, changing within the 3-year study from a grass–fern to shrub–sedge community encroached by midstorey species. The current short rotations between management events unnecessarily maintain the corridor in a cycle of degradation, remove resources for native species and may allow introduced grasses and saplings to proliferate in the corridor. Maintaining a shrub layer would help avoid loss of species richness, encourage native species and limit colonisation opportunities of introduced species. Spot spraying emergent saplings and problem plants and mosaic slashing, would keep fire risk low and maintain biodiversity without increasing biomass to dangerous levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Powerline corridors through forested ecosystems have been criticised due their potential to fragment the landscape and facilitate the intrusion of undesirable species into natural areas. This study investigates the effects of vegetation management (slashing), on: (1) timing of small mammal recolonisation; (2) vegetation characteristics that drive small mammal responses; and (3) the point where corridor resources are sufficient to provide functional habitat for native species. Small mammal trapping was undertaken within Bunyip State Park, Australia, across three sites, once a month from January 2001 to May 2002 and every 2 months thereafter until January 2004. Changes in vegetation around each trap station were assessed annually in the forest and bi-annually in the corridor. Principal components analysis on the vegetation structural complexity values produced factors for use in species abundance models. Native small mammal species recolonised the corridor 1.5–3.5 years after management and the corridor supported a breeding population of small mammals around 2.5 years post-management. Males however, generally recolonised the corridor first, resulting in a sex-biased population in these areas. Species corridor habitat models for five native and one introduced species suggested cover and shelter were more important in determining corridor use than plant species per se. Powerline corridors have the potential to create a mixture of different successional stages, enhancing habitat availability for many species. However, the intensity of current management needs to be reduced and an integrated approach to management needs to be undertaken if powerline corridors are to continuously provide habitat for native small mammal species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis investigated the ecological impacts of powerline corridor management on small mammals. The study found that powerline corridors provide habitat for native small mammal species, contrary to common belief that Australian powerline corridors are poor in native species. It is important however, that ecological sensitive management regimes are implemented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The following paper presents an evaluation of airborne sensors for use in vegetation management in powerline corridors. Three integral stages in the management process are addressed including, the detection of trees, relative positioning with respect to the nearest powerline and vegetation height estimation. Image data, including multi-spectral and high resolution, are analyzed along with LiDAR data captured from fixed wing aircraft. Ground truth data is then used to establish the accuracy and reliability of each sensor thus providing a quantitative comparison of sensor options. Tree detection was achieved through crown delineation using a Pulse-Coupled Neural Network (PCNN) and morphologic reconstruction applied to multi-spectral imagery. Through testing it was shown to achieve a detection rate of 96%, while the accuracy in segmenting groups of trees and single trees correctly was shown to be 75%. Relative positioning using LiDAR achieved a RMSE of 1.4m and 2.1m for cross track distance and along track position respectively, while Direct Georeferencing achieved RMSE of 3.1m in both instances. The estimation of pole and tree heights measured with LiDAR had a RMSE of 0.4m and 0.9m respectively, while Stereo Matching achieved 1.5m and 2.9m. Overall a small number of poles were missed with detection rates of 98% and 95% for LiDAR and Stereo Matching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fixed-wing aircraft equipped with downward pointing cameras and/or LiDAR can be used for inspecting approximately piecewise linear assets such as oil-gas pipelines, roads and power-lines. Automatic control of such aircraft is important from a productivity and safety point of view (long periods of precision manual flight at low-altitude is not considered reasonable from a safety perspective). This paper investigates the effect of any unwanted coupling between guidance and autopilot loops (typically caused by unmodeled delays in the aircraft’s response), and the specific impact of any unwanted dynamics on the performance of aircraft undertaking inspection of piecewise linear corridor assets (such as powerlines). Simulation studies and experimental flight tests are used to demonstrate the benefits of a simple compensator in mitigating the unwanted lateral oscillatory behaviour (or coupling) that is caused by unmodeled time constants in the aircraft dynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, the effect of ions and ultrafine particles on ambient air quality and human health has been well documented, however, knowledge about their sources, concentrations and interactions within different types of urban environments remains limited. This thesis presents the results of numerous field studies aimed at quantifying variations in ion concentration with distance from the source, as well as identifying the dynamics of the particle ionisation processes which lead to the formation of charged particles in the air. In order to select the most appropriate measurement instruments and locations for the studies, a literature review was also conducted on studies that reported ion and ultrafine particle emissions from different sources in a typical urban environment. The initial study involved laboratory experiments on the attachment of ions to aerosols, so as to gain a better understanding of the interaction between ions and particles. This study determined the efficiency of corona ions at charging and removing particles from the air, as a function of different particle number and ion concentrations. The results showed that particle number loss was directly proportional to particle charge concentration, and that higher small ion concentrations led to higher particle deposition rates in all size ranges investigated. Nanoparticles were also observed to decrease with increasing particle charge concentration, due to their higher Brownian mobility and subsequent attachment to charged particles. Given that corona discharge from high voltage powerlines is considered one of the major ion sources in urban areas, a detailed study was then conducted under three parallel overhead powerlines, with a steady wind blowing in a perpendicular direction to the lines. The results showed that large sections of the lines did not produce any corona at all, while strong positive emissions were observed from discrete components such as a particular set of spacers on one of the lines. Measurements were also conducted at eight upwind and downwind points perpendicular to the powerlines, spanning a total distance of about 160m. The maximum positive small and large ion concentrations, and DC electric field were observed at a point 20 m downwind from the lines, with median values of 4.4×103 cm-3, 1.3×103 cm-3 and 530 V m-1, respectively. It was estimated that, at this point, less than 7% of the total number of particles was charged. The electrical parameters decreased steadily with increasing downwind distance from the lines but remained significantly higher than background levels at the limit of the measurements. Moreover, vehicles are one of the most prevalent ion and particle emitting sources in urban environments, and therefore, experiments were also conducted behind a motor vehicle exhaust pipe and near busy motorways, with the aim of quantifying small ion and particle charge concentration, as well as their distribution as a function of distance from the source. The study found that approximately equal numbers of positive and negative ions were observed in the vehicle exhaust plume, as well as near motorways, of which heavy duty vehicles were believed to be the main contributor. In addition, cluster ion concentration was observed to decrease rapidly within the first 10-15 m from the road and ion-ion recombination and ion-aerosol attachment were the most likely cause of ion depletion, rather than dilution and turbulence related processes. In addition to the above-mentioned dominant ion sources, other sources also exist within urban environments where intensive human activities take place. In this part of the study, airborne concentrations of small ions, particles and net particle charge were measured at 32 different outdoor sites in and around Brisbane, Australia, which were classified into seven different groups as follows: park, woodland, city centre, residential, freeway, powerlines and power substation. Whilst the study confirmed that powerlines, power substations and freeways were the main ion sources in an urban environment, it also suggested that not all powerlines emitted ions, only those with discrete corona discharge points. In addition to the main ion sources, higher ion concentrations were also observed environments affected by vehicle traffic and human activities, such as the city centre and residential areas. A considerable number of ions were also observed in a woodland area and it is still unclear if they were emitted directly from the trees, or if they originated from some other local source. Overall, it was found that different types of environments had different types of ion sources, which could be classified as unipolar or bipolar particle sources, as well as ion sources that co-exist with particle sources. In general, fewer small ions were observed at sites with co-existing sources, however particle charge was often higher due to the effect of ion-particle attachment. In summary, this study quantified ion concentrations in typical urban environments, identified major charge sources in urban areas, and determined the spatial dispersion of ions as a function of distance from the source, as well as their controlling factors. The study also presented ion-aerosol attachment efficiencies under high ion concentration conditions, both in the laboratory and in real outdoor environments. The outcomes of these studies addressed the aims of this work and advanced understanding of the charge status of aerosols in the urban environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Corona discharge is responsible for the small ions found near overhead power lines, and these are capable of modifying the ambient electrical environment such as the dc electric field at ground level (Fews, Wilding et al. 2002). Once produced, small ions quickly attach to aerosol particles in the air, producing ‘large ions’ which are roughly 1 nm to 1 µm in diameter. However, very few studies have reported measurements of ions produced by power lines and its impact on particle charge concentrations. In this present study, the measurements were conducted as a function of normal downwind distance from a 275kV power line for investigating the effect of corona ions on air ions, aerosol particle charge concentration and dc e-filed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Corona discharge is responsible for the flux of small ions from overhead power lines, and is capable of modifying the ambient electrical environment, such as the air ion concentrations at ground level. Once produced, small ions quickly attach to aerosol particles in the air, producing ‘large ions’, approximately 1 nm to 1 µm in diameter. However, very few studies have measured air ion concentrations directly near high voltage transmission lines. The present study involved the simultaneously measurement of small ion concentration and net large ion concentration using air ion counters and an aerosol electrometer at four power line sites. Both positive and negative small ion concentration (<1.6nm), net large ion concentration (2nm-5μm) and particle number concentration (10nm-2μm) were measured using air ion counters and an aerosol electrometer at four power line sites. Measurements at sites 1 and 2 were conducted at both upwind and downwind sides. The results showed that total ion concentrations on the downwind side were 3-5 times higher than on the upwind side, while particle number concentrations did not show a significant difference. This result also shows that a large number of ions were emitted from the power lines at sites 1 and 2. Furthermore, both positive and negative ions were observed at different power line sites. Dominant positive ions were observed at site 1, with a concentration of 4.4 x 103 ions cm-3, which was 10 times higher than on the upwind side. Contrary to site 1, sites 2 to 4 showed negative ion emissions, with concentrations of -1.2 x 103, -460 and -410 ions cm-3, respectively. These values were higher than the background urban negative ion concentration of 400 cm-3. At site 1 and site 2, the net ion concentration and net particle charge concentration on downwind side of the lines showed same polarities. Further investigations were also conducted into the correlation between net ion concentration and net charge particle concentration 20 m downwind of the power lines at site 2. The two parameters showed a correlation coefficient of 0.72, indicating that a substantial number of ions could attach to particles and affect the particle charge status within a short distance from the source.