960 resultados para pollen concentration in the air
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: a) conventional air distribution system with ceiling supply and return; b) conventional air distribution system with ceiling supply and return near the floor; c) underfloor air distribution system; and d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the Indoor/Outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used.
Resumo:
This study detailed the structure of turbulence in the air-side and water-side boundary layers in wind-induced surface waves. Inside the air boundary layer, the kurtosis is always greater than 3 (the value for normal distribution) for both horizontal and vertical velocity fluctuations. The skewness for the horizontal velocity is negative, but the skewness for the vertical velocity is always positive. On the water side, the kurtosis is always greater than 3, and the skewness is slightly negative for the horizontal velocity and slightly positive for the vertical velocity. The statistics of the angle between the instantaneous vertical fluctuation and the instantaneous horizontal velocity in the air is similar to those obtained over solid walls. Measurements in water show a large variance, and the peak is biased towards negative angles. In the quadrant analysis, the contribution of quadrants Q2 and Q4 is dominant on both the air side and the water side. The non-dimensional relative contributions and the concentration match fairly well near the interface. Sweeps in the air side (belonging to quadrant Q4) act directly on the interface and exert pressure fluctuations, which, in addition to the tangential stress and form drag, lead to the growth of the waves. The water drops detached from the crest and accelerated by the wind can play a major role in transferring momentum and in enhancing the turbulence level in the water side.On the air side, the Reynolds stress tensor's principal axes are not collinear with the strain rate tensor, and show an angle α σ≈=-20°to-25°. On the water side, the angle is α σ≈=-40°to-45°. The ratio between the maximum and the minimum principal stresses is σ a/σ b=3to4 on the air side, and σ a/σ b=1.5to3 on the water side. In this respect, the air-side flow behaves like a classical boundary layer on a solid wall, while the water-side flow resembles a wake. The frequency of bursting on the water side increases significantly along the flow, which can be attributed to micro-breaking effects - expected to be more frequent at larger fetches. © 2012 Elsevier B.V.
Resumo:
O objetivo deste trabalho foi avaliar os efeitos do aumento da concentração de CO2 do ar sobre o crescimento de plantas e sobre a mancha foliar causada por Cylindrocladium candelabrum em Eucalyptus urophylla. As mudas foram cultivadas durante 30 dias, a 451, 645, 904, 1.147 µmol mol-1 de CO2 ; em seguida, elas foram inoculadas com o patógeno e mantidas nas mesmas condições por sete dias. O aumento da concentração de CO2 aumentou a altura de plantas e a massa de matéria seca da parte aérea, e diminuiu a incidência e a severidade da doença. O diâmetro do caule não foi afetado pelos tratamentos. O aumento das concentrações de CO2 atmosférico afeta favoravelmente o crescimento de plântulas de eucalipto e reduz a severidade da mancha foliar.
Resumo:
dall'avvento della liberalizzazione, aeroporti e vettori hanno vissuto cambiamenti. Il maggior miglioramneto nella gestione degli aeroporti è una gestione più commerciale ed efficiente. Le forme di regolazione economica e le caratteristiche della gestione manageriale sono state indagate. Dodici paesi sono stati scelti per indagare la situazione del trasporto aereo mondiale, fra questi sia paesi con un sistema maturo sia paesi emergenti. La distribuzione del traffico è stata analizzata con l'indice HHI per evidenziare aeroporti con concentrazione maggiore di 0,25 (in accordo con la normativa statunitense); il sistema aeroportuale è stato analizzato con l'indice di Gini e con l'indice di dominanza. Infine, la teoria dei giochi si è dimostrata un valido supporto per studiare il mercato del trasporto aereo anche con l'uso di giochi di tipo DP
Resumo:
We explored the temporal and spatial variations in airborne Alternaria spore quantitative and phenological features in Europe using 23 sites with annual time series between 3 and 15 years. The study covers seven countries and four of the main biogeographical regions in Europe. The observations were obtained with Hirst-type spore traps providing time series with daily records. Site locations extend from Spain in the south to Denmark in the north and from England in the West to Poland in the East. The study is therefore the largest assessment ever carried out for Europe concerning Alternaria. Aerobiological data were investigated for temporal and spatial patterns in their start and peak season dates and their spore indices. Moreover, the effects of climate were checked using meteorological data for the same period, using a crop growth model. We found that local climate, vegetation patterns and management of landscape are governing parameters for the overall spore concentration, while the annual variations caused by weather are of secondary importance but should not be neglected. The start of the Alternaria spore season varies by several months in Europe, but the peak of the season is more synchronised in central northern Europe in the middle of the summer, while many southern sites have peak dates either earlier or later than northern Europe. The use of a crop growth model to explain the start and peak of season suggests that such methods could be useful to describe Alternaria seasonality in areas with no available observations.
Resumo:
The human health effects following exposure to ultrafine (<100nm) particles (UFPs) produced by fuel combustion, while not completely understood, are generally regarded as detrimental. Road tunnels have emerged as locations where maximum exposure to these particles may occur for the vehicle occupants using them. This study aimed to quantify and investigate the determinants of UFP concentrations in the 4km twin-bore (eastbound and westbound) M5 East tunnel in Sydney, Australia. Sampling was undertaken using a condensation particle counter (CPC) mounted in a vehicle traversing both tunnel bores at various times of day from May through July, 2006. Supplementary measurements were conducted in February, 2008. Over three hundred transects of the tunnel were performed, and these were distributed evenly between the bores. Additional comparative measurements were conducted on a mixed route comprising major roads and shorter tunnels, all within Sydney. Individual trip average UFP concentrations in the M5 East tunnel bores ranged from 5.53 × 104 p cm-3 to 5.95 × 106 p cm-3. Data were sorted by hour of capture, and hourly median trip average (HMA) UFP concentrations ranged from 7.81 × 104 p cm-3 to 1.73 × 106 p cm-3. Hourly median UFP concentrations measured on the mixed route were between 3.71 × 104 p cm-3 and 1.55 × 105 p cm-3. Hourly heavy diesel vehicle (HDV) traffic volume was a very good determinant of UFP concentration in the eastbound tunnel bore (R2 = 0.87), but much less so in the westbound bore (R2 = 0.26). In both bores, the volume of passenger vehicles (i.e. unleaded gasoline-powered vehicles) was a significantly poorer determinant of particle concentration. When compared with similar studies reported previously, the measurements described here were among the highest recorded concentrations, which further highlights the contribution road tunnels may make to the overall UFP exposure of vehicle occupants.
Resumo:
This latest briefing by Professor Reece Walters in the What is crime? series, draws attention to an area of harm that is often absent from criminological debate. He highlights the human costs of air pollution and failed attempts to adequately regulate and control such harm. Arguing for a cross disciplinary ‘eco-crime’ narrative, the author calls for greater understanding of the far-reaching consequences of air pollution which could set in train changes which may lead to a ‘more robust and meaningful system of justice’. Describing current arrangements in place to control and regulate air pollution, Walters draws attention to the lack of neutrality in current arrangements and the bias ‘towards the economic imperatives of free trade over and above the centrality of environmental protection’. While attention is often given to direct and individualised instances of ‘crime’, the serious consequences of air pollution are frequently neglected. The negative effects of pollution on health and well-being are often borne by people already experiencing a range of other disadvantages. In a global and national context, it is often the poor who are affected most. Ultimately, political and economic imperatives have historically helped to shape legal and regulatory regimes. Whether this is an inherent flaw in current systems or something that can be overcome in favour of dealing with more wide-ranging harms is an area that requires further discussion and debate.
Resumo:
Aims: To investigate methods for the recovery of airborne bacteria within pig sheds and to then use the appropriate methods to determine the levels of heterotrophs and Escherichia coli in the air within sheds. Methods and Results: AGI-30 impingers and a six-stage Andersen multi-stage sampler (AMS) were used for the collection of aerosols. Betaine and catalase were added to impinger collection fluid and the agar plates used in the AMS. Suitable media for enumerating E. coli with the Andersen sampler were also evaluated. The addition of betaine and catalase gave no marked increase in the recovery of heterotrophs or E. coli. No marked differences were found in the media used for enumeration of E. coli. The levels of heterotrophs and E. coli in three piggeries, during normal pig activities, were 2Æ2 · 105 and 21 CFU m)3 respectively. Conclusions: The failure of the additives to improve the recovery of either heterotrophs or E. coli suggests that these organisms are not stressed in the piggery environment. The levels of heterotrophs in the air inside the three Queensland piggeries investigated are consistent with those previously reported in other studies. Flushing with ponded effluent had no marked or consistent effect on the heterotroph or E. coli levels. Significance and Impact of the Study: Our work suggests that levels of airborne heterotrophs and E. coli inside pig sheds have no strong link with effluent flushing. It would seem unlikely that any single management activity within a pig shed has a dominant influence on levels of airborne heterotrophs and E. coli
Resumo:
Two high-frequency (HF) radar stations were installed on the coast of the south-eastern Bay of Biscay in 2009, providing high spatial and temporal resolution and large spatial coverage of currents in the area for the first time. This has made it possible to quantitatively assess the air-sea interaction patterns and timescales for the period 2009-2010. The analysis was conducted using the Barnett-Preisendorfer approach to canonical correlation analysis (CCA) of reanalysis surface winds and HF radar-derived surface currents. The CCA yields two canonical patterns: the first wind-current interaction pattern corresponds to the classical Ekman drift at the sea surface, whilst the second describes an anticyclonic/cyclonic surface circulation. The results obtained demonstrate that local winds play an important role in driving the upper water circulation. The wind-current interaction timescales are mainly related to diurnal breezes and synoptic variability. In particular, the breezes force diurnal currents in waters of the continental shelf and slope of the south-eastern Bay. It is concluded that the breezes may force diurnal currents over considerably wider areas than that covered by the HF radar, considering that the northern and southern continental shelves of the Bay exhibit stronger diurnal than annual wind amplitudes.
Resumo:
To determine the environmental factors influencing C, phytoplankton chlorophyll a (Ch1 a), field investigations 4 were conducted in three river-connected lakes (Dongting Lake, Poyang Lake and Shijiu Lake) of the Yangtze floodplain in 2004. Results showed that the average Chi a concentration in these lakes ranged from 2.98 to 3.65 mg m(-3). The major factors influencing Chl a in lentic and lotic regions were total phosphorus (TP) and water velocity (U), respectively. Multiple relationships including total nitrogen (log(10)TN) and water depth (log(10)Z) were established. Further analyses found that the absolute Chi a and slope of log(10)Chl a=f (log(10)TP) in the river-connected lakes were obviously lower than those in the river-isolated lakes. This suggests the river-lake connectivity can significantly modify relationship between TP and chlorophyll a concentration.