499 resultados para plc opc


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This report discusses developing a software log tool for analysis of industrial processes. The target was to develop software that can help electro Engineers for monitor and fault finding in industrial processes. The tool is called PLS (Process log server), and is developed in Visual Studio.NET Framework 2005. PLS works as a client with Beijer Electronics OPC Server. The program is able to read data from PLC (Programmable Logic Controller), trough the OPC Server. PLS connects to all kind of controllers that is supported by the Beijer Electronics OPC Server. Signal data is stored in a database for later analysis. Chosen signals data can easily be exported into a text file. The text file is adopted for import to MS Office Excel. User manual [UM-07] is written as a separate document. The software acted stable through the function test. The final product becomes a first-rate tool that is simple to use. As an advantage, the software can be developed with more functions in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atualmente, no segmento metro-ferroviário, há uma tendência para que todos os equipamentos que constituem os sistemas auxiliares de uma estação (escadas mecânicas, elevadores, bloqueadores, validadores de bilhética, ventiladores, bombas, entre outros) sejam dotados de inteligência. Tipicamente, um conjunto de equipamentos são ligados a um autómato que permite o controlo local e remoto e é vulgar que, sendo de fabricantes diferentes, suportem tecnologias distintas. Um sistema de supervisão que permita o acesso à informação disponibilizada por cada um dos autómatos, ou à atuação sobre um deles, terá por isso que implementar e suportar diversos protocolos de comunicação de forma a não ficar limitado a um tipo de tecnologia. De forma a diminuir os custos de desenvolvimento e operação de um sistema de supervisão e controlo e facilitar a integração de novos equipamentos, com diferentes características, têm sido procuradas soluções que garantam uma mais fácil comunicação entre os diversos módulos intervenientes. Nesta dissertação são implementadas soluções baseadas em clientes OPC-DA e OPC-AE e no protocolo IEC 60870-5-104, permitindo que os sistemas de supervisão e de controlo comuniquem com os equipamentos através destes três módulos. Os principais aspectos inovadores estão associados à implementação de uma arquitetura multiprotocolo usando as novas tendências de supervisão e controlo baseadas em soluções distribuídas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Even though the involvement of intracellular Ca(2+) (Ca(i)(2+)) in hematopoiesis has been previously demonstrated, the relationship between Ca(i)(2+) signaling and cytokine-induced intracellular pathways remains poorly understood. Herein, the molecular mechanisms integrating Ca(2+) signaling with the extracellular signal-regulated kinase 1/2 (ERK1/2) pathway in primary murine and human hematopoietic stem/progenitor cells stimulated by IL-3 and GM-CSF were studied. Our results demonstrated that IL-3 and GM-CSF stimulation induced increased inositol 1,4,5-trisphosphate (IP(3)) levels and Ca(i)(2+) release in murine and human hematopoietic stem/ progenitor cells. In addition, Ca(i)(2+) signaling inhibitors, such as inositol 1,4,5-trisphosphate receptor antagonist (2-APB), PKC inhibitor (GF109203), and CaMKII inhibitor (KN-62), blocked phosphorylation of MEK activated by IL-3 and GM-CSF, suggesting the participation of Ca(2+)-dependent kinases in MEK activation. In addition, we identify phospholipase C gamma 2 (PLC gamma 2) as a PLC gamma responsible for the induction of Ca(2+) release by IL-3 and GM-CSF in hematopoietic stem/progenitor cells. Furthermore, the PLCg inhibitor U73122 significantly reduced the numbers of granulocyte-macrophage colony-forming units after cytokine stimulation. Similar results were obtained in both murine and human hematopoietic stem/progenitor cells. Taken together, these data indicate a role for PLC gamma 2 and Ca(2+) signaling through the modulation of MEK in both murine and human hematopoietic stem/ progenitor cells. J. Cell. Physiol. 226: 1780-1792, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The syndrome of inappropriate secretion of antidiuretic hormone is a rare disorder in dogs characterised by hypo-osmolality and persistent arginine vasopressin production in the absence of hypovolaemia and/or hypotension. The study describes the efficacy and safety of the nonpeptide selective arginine vasopressin V-2 receptor antagonist OPC-31260 in a dog with the naturally occurring syndrome. Design The detailed case history of a dog with spontaneous syndrome of inappropriate secretion of antidiuretic hormone that received long-term therapy with oral OPC-31260 is presented. Effects of the first dose of OPC-31260 and of a dose administered after a continuous dosing period of 12 days are reported. Procedure Packed cell volume, plasma sodium, total protein, arginine vasopressin, renin activity, atrial natriuretic peptide, urine specific gravity, urine output, heart rate and body weight were monitored for 2 h before, and for 4 h after, the first dose of OPC-31260. The same parameters plus plasma osmolality and urine osmolality were monitored when an identical dose was administered after 12 days of therapy. Results Oral administration of OPC-31260 at 3 mg/kg body weight resulted in marked aquaresis with increased urine output and decline in urine specific gravity within 1 h. Corresponding increases in concentrations of plasma sodium, plasma osmolality and plasma renin activity were recorded over a 4 h period. Arginine vasopressin concentration remained inappropriately elevated throughout the study. Results were similar when the trial procedure was repeated after a stabilisation period of 12 days. Long-term therapy with OPC-31260 at a dose of 3 mg/kg body weight orally every 12 h resulted in good control of clinical signs with no deleterious effects detected during a 3-year follow-up period. Despite sustained clinical benefits observed in this case, plasma sodium did not normalise with continued administration of the drug. Conclusions Treatment of a dog with naturally occurring syndrome of inappropriate secretion of antidiuretic hormone with OPC-31260 at 3 mg/kg body weight orally every 12 h resulted in marked aquaresis and significant palliation of clinical signs with no discernible side-effects detected over a 3-year period. Thus, OPC-31260 appears to offer a feasible medical alternative to water restriction for treatment of dogs with syndrome of inappropriate secretion of antidiuretic hormone. Higher doses of OPC-31260 may be required to achieve and maintain normal plasma sodium in dogs with this syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho pretende preencher uma lacuna no controlo difuso em todos os autómatos/controladores que usam a plataforma Codesys para a sua programação. Começando por um levantamento histórico e a respetiva compreensão do que é a lógica difusa até à análise do que existe no mercado nos dias de hoje. Será realizada uma abordagem do que é a plataforma Codesys e a utilização da norma IEC61131-3. Sendo efetuada também uma análise da norma IEC61131-7 que explica como deve ser realizado o controlo difuso em PLC. Para colmatar a lacuna existente foi desenvolvido um software tendo por base a plataforma Codesys e validado e testado com o software SoMachine da Schneider Electric. Esse software será devidamente descrito para ser entendido de uma forma fácil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equity research report

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equity research report

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the determinism of the AS-lnterface network and the 3 main families of control systems, which may use it, namely PLC, PC and RTOS. During the course of this study the PROFIBUS and Ethernet field level networks were also considered in order to ensure that they would not introduce unacceptable latencies into the overall control system. This research demonstrated that an incorrectly configured Ethernet network introduces unacceptable variable duration latencies into the control system, thus care must be exercised if the determinism of a control system is not to be compromised. This study introduces a new concept of using statistics and process capability metrics in the form of CPk values, to specify how suitable a control system is for a given control task. The PLC systems, which were tested, demonstrated extremely deterministic responses, but when a large number of iterations were introduced in the user program, the mean control system latency was much too great for an AS-I network. Thus the PLC was found to be unsuitable for an AS-I network if a large, complex user program Is required. The PC systems, which were tested were non-deterministic and had latencies of variable duration. These latencies became extremely exaggerated when a graphing ActiveX was included in the control application. These PC systems also exhibited a non-normal frequency distribution of control system latencies, and as such are unsuitable for implementation with an AS-I network. The RTOS system, which was tested, overcame the problems identified with the PLC systems and produced an extremely deterministic response, even when a large number of iterations were introduced in the user program. The RTOS system, which was tested, is capable of providing a suitable deterministic control system response, even when an extremely large, complex user program is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treball que, després de revisar el concepte de PLC i d'exposar la necessitat de solucions obertes, defineix el concepte de PLC obert, basat en programari lliure i presenta alguns projectes interessants de PLC obert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

S'ha realitzat un estudi per conèixer que és el PLC, quins tipus existeixen, la normativa que hi ha al voltant, quin hardware utilitza per després crear i analitzar dos cassos d'estudi: una xarxa domèstica i un edifici de nova construcció, en el que s'oferirà als futurs compradors Internet en qualsevol endoll de l'edifici.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La Universitat de Vic disposa, entre altres equips, d’una cèl·lula flexible de fabricació, del fabricant Festo, que simula un procés de formació de palets amb els productes que es disposen en un magatzem intermedi. Aquesta cèl·lula està composta de quatre estacions de muntatge diferenciades (càrrega de palets, càrrega de plaques, magatzem intermedi i transport). Cada una disposa d'un PLC SIEMENS S7-300 per la seva automatització, i tots aquests es troben interconnectats amb una xarxa industrial Profibus. L'objectiu d'aquest projecte és implantar el sistema SCADA Vijeo Citect pel control i supervisió de l'estació magatzem d'aquesta cèl·lula flexible de fabricació, establint també un intercanvi de dades entre l'SCADA i el Microsoft Access, per poder ser utilitzat per la docència. Aquest projecte s'ha desenvolupat en cinc fases diferents: 1. La primera fase s'ha dedicat a l'automatització pròpiament de l'estació magatzem a partir de l'autòmat programable Siemens S7-300 i complint amb les necessitats plantejades. 2. En la segona fase s'ha programat i establert la comunicació per l'intercanvi de dades (lectura i escriptura) entre el sistema SCADA Vijeo Citect i la base de dades de Microsoft Access. 3. En la tercera fase s'ha elaborat i programat l'entorn gràfic de supervisió i control del procés a partir del sistema SCADA Vijeo Citect. 4. En la quarta fase s'ha instal·lat un OPC Server en el PC i s'ha establert la comunicació entre el PLC i el sistema SCADA. 5. Finalment s'ha anat revisant i depurant les diferents programacions i comunicacions per tal de que el sistema funcioni com a un conjunt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whether adenosine, a crucial regulator of the developing cardiovascular system, can provoke arrhythmias in the embryonic/fetal heart remains controversial. Here, we aimed to establish a mechanistic basis of how an adenosinergic stimulation alters function of the developing heart. Spontaneously beating hearts or dissected atria and ventricle obtained from 4-day-old chick embryos were exposed to adenosine or specific agonists of the receptors A(1)AR (CCPA), A(2A)AR (CGS-21680) and A(3)AR (IB-MECA). Expression of the receptors was determined by quantitative PCR. The functional consequences of blockade of NADPH oxidase, extracellular signal-regulated kinase (ERK), phospholipase C (PLC), protein kinase C (PKC) and L-type calcium channel (LCC) in combination with adenosine or CCPA, were investigated in vitro by electrocardiography. Furthermore, the time-course of ERK phosphorylation was determined by western blotting. Expression of A(1)AR, A(2A)AR and A(2B)AR was higher in atria than in ventricle while A(3)AR was equally expressed. Adenosine (100μM) triggered transient atrial ectopy and second degree atrio-ventricular blocks (AVB) whereas CCPA induced mainly Mobitz type I AVB. Atrial rhythm and atrio-ventricular propagation fully recovered after 60min. These arrhythmias were prevented by the specific A(1)AR antagonist DPCPX. Adenosine and CCPA transiently increased ERK phosphorylation and induced arrhythmias in isolated atria but not in ventricle. By contrast, A(2A)AR and A(3)AR agonists had no effect. Interestingly, the proarrhythmic effect of A(1)AR stimulation was markedly reduced by inhibition of NADPH oxidase, ERK, PLC, PKC or LCC. Moreover, NADPH oxidase inhibition or antioxidant MPG prevented both A(1)AR-mediated arrhythmias and ERK phosphorylation. These results suggest that pacemaking and conduction disturbances are induced via A(1)AR through concomitant stimulation of NADPH oxidase and PLC, followed by downstream activation of ERK and PKC with LCC as possible target.