5 resultados para photodocumentation
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
ABSTRACT A detailed protocol for chemical clearing of bee specimens is presented. Dry specimens as well as those preserved in liquid media can be cleared using this protocol. The procedure consists of a combined use of alkaline solution (KOH or NaOH) and hydrogen peroxide (H2O2), followed by the boiling of the cleared specimens in 60–70% EtOH. Clearing is particularly useful for internal skeletal morphological research. This procedure allows for efficient study of internal projections of the exoskeleton (e.g., apodemes, furcae, phragmata, tentoria, internal ridges and sulci), but this process makes external features of the integument, as some sutures and sulci, readily available for observation as well. Upon completion of the chemical clearing process the specimens can be stored in glycerin. This procedure was developed and evaluated for the preparation of bees and other Apoidea, but modifications for use with other insect taxa should be straightforward after some experimentation on variations of timing of steps, concentration of solutions, temperatures, and the necessity of a given step. Comments on the long-term storage, morphological examination, and photodocumentation of cleared specimens are also provided.
Resumo:
AIM: To assess functional impairment in terms of visual acuity reduction and visual field defects in inactive ocular toxoplasmosis. METHODS: 61 patients with known ocular toxoplasmosis in a quiescent state were included in this prospective, cross-sectional study. A complete ophthalmic examination, retinal photodocumentation and standard automated perimetry (Octopus perimeter, program G2) were performed. Visual acuity was classified on the basis of the World Health Organization definition of visual impairment and blindness: normal (> or =20/25), mild (20/25 to 20/60), moderate (20/60 to 20/400) and severe (<20/400). Visual field damage was correspondingly graded as mild (mean defect <4 dB), moderate (mean defect 4-12 dB) or severe (mean defect >12 dB). RESULTS: 8 (13%) patients presented with bilateral ocular toxoplasmosis. Thus, a total of 69 eyes was evaluated. Visual field damage was encountered in 65 (94%) eyes, whereas only 28 (41%) eyes had reduced visual acuity, showing perimetric findings to be more sensitive in detecting chorioretinal damage (p<0.001). Correlation with the clinical localisation of chorioretinal scars was better for visual field (in 70% of the instances) than for visual acuity (33%). Moderate to severe functional impairment was registered in 65.2% for visual field, and in 27.5% for visual acuity. CONCLUSION: In its quiescent stage, ocular toxoplasmosis was associated with permanent visual field defects in >94% of the eyes studied. Hence, standard automated perimetry may better reflect the functional damage encountered by ocular toxoplasmosis than visual acuity.
Resumo:
BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.
Resumo:
By making the photogrammetric monoplotting-procedure operational, this new method is now applicable for the documentation of glacial snow depletion. In a time series taken in summer 1990 monoplotting was the first time used for terrestrial survey of a glacier. The monoplotting-procedure, the terrestrial photodocumentation and the geodetic evaluation are described. The results from the Stubacher Sonnblickkees are presented in tabular form as well as in a series of thematic maps. A comparison of monoplotting and aerophotogrammetric survey confirms the suitability of the monoplotting-procedure for the mapping of glacial snow depletion.