977 resultados para pc


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parallel combinatory orthogonal frequency division multiplexing (PC-OFDM yields lower maximum peak-to-average power ratio (PAR), high bandwidth efficiency and lower bit error rate (BER) on Gaussian channels compared to OFDM systems. However, PC-OFDM does not improve the statistics of PAR significantly. In this chapter, the use of a set of fixed permutations to improve the statistics of the PAR of a PC-OFDM signal is presented. For this technique, interleavers are used to produce K-1 permuted sequences from the same information sequence. The sequence with the lowest PAR, among K sequences is chosen for the transmission. The PAR of a PC-OFDM signal can be further reduced by 3-4 dB by this technique. Mathematical expressions for the complementary cumulative density function (CCDF)of PAR of PC-OFDM signal and interleaved PC-OFDM signal are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In just under 3 months worldwide sales of Apple's iPad tablet device stood at over 3 million units sold. The iPad device, along with rival products signify a shift in the way in which print and other media products are purchased and consumed by users. While facing initial skepticism about the uptake of the device numerous industries have been quick to adapt the device to their specific needs. Based around a newly developed six point typology of “post PC” device utility this project undertook a significant review of publicly available material to identify worldwide trends in iPad adoption and use within the tertiary sector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed digital image registration program for a MC 68000 based fundus image processing system (FIPS). FIPS not only is capable of executing typical image processing algorithms in spatial as well as Fourier domain, the execution time for many operations has been made much quicker by using a hybrid of "C", Fortran and MC6000 assembly languages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Needs assessment strategies can facilitate prioritisation of resources. To develop a needs assessment tool for use with advanced cancer patients and caregivers, to prompt early intervation. A convenience sample of 103 health professionals viewed three videotaped consultations involving a simulated patient, his/her caregiver and a health professional, completed the Palliative Care Needs Assessment Tool (PC-NAT) and provided feedback on clarity, content and acceptability of the PC-NAT. Face and content validity, acceptability and feasibility of the PC-NAT were confirmed. Kappa scores indicated adequate inter-rater reliability for the majority of domains; the patient spirituality domain and the caregiver physical and family and relationship domains had low reliability. The PC-NAT can be used by health professionals with a range of clinical expertise to identify individuals' needs, thereby enabling early intervention. Further psychometric testing and an evaluation to assess the impact of the systematic use of the PC-NAT on quality of life, unmet needs and service utilisation of patients and caregivers are underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Quality of life (QOL) measures are an important patient-relevant outcome measure for clinical studies. Currently there is no fully validated cough-specific QOL measure for paediatrics. The objective of this study was to validate a cough-specific QOL questionnaire for paediatric use. Method 43 children (28 males, 15 females; median age 29 months, IQR 20–41 months) newly referred for chronic cough participated. One parent of each child completed the 27-item Parent Cough-Specific QOL questionnaire (PC-QOL), and the generic child (Pediatric QOL Inventory 4.0 (PedsQL)) and parent QOL questionnaires (SF-12) and two cough-related measures (visual analogue score and verbal category descriptive score) on two occasions separated by 2–3 weeks. Cough counts were also objectively measured on both occasions. Results Internal consistency for both the domains and total PC-QOL at both test times was excellent (Cronbach alpha range 0.70–0.97). Evidence for repeatability and criterion validity was established, with significant correlations over time and significant relationships with the cough measures. The PC-QOL was sensitive to change across the test times and these changes were significantly related to changes in cough measures (PC-QOL with: verbal category descriptive score, rs=−0.37, p=0.016; visual analogue score, rs=−0.47, p=0.003). Significant correlations of the difference scores for the social domain of the PC-QOL and the domain and total scores of the PedsQL were also noted (rs=0.46, p=0.034). Conclusion The PC-QOL is a reliable and valid outcome measure that assesses QOL related to childhood cough at a given time point and measures changes in cough-specific QOL over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To assess the usability and validity of the Primary Care Practice Improvement Tool (PC-PIT), a practice performance improvement tool based on 13 key elements identified by a systematic review. It was co-created with a range of partners and designed specifically for primary health care. Design This pilot study examined the PC-PIT using a formative assessment framework and mixed-methods research design. Setting and participants Six high-functioning general practices in Queensland, Australia, between February and July 2013. A total of 28 staff participated — 10 general practitioners, six practice or community nurses, 12 administrators (four practice managers; one business manager and eight reception or general administrative staff). Main outcome measures Readability, content validity and staff perceptions of the PC-PIT. Results The PC-PIT offers an appropriate and acceptable approach to internal quality improvement in general practice. Quantitative assessment scores and qualitative data from all staff identified two areas in which the PC-PIT required modification: a reduction in the indicative reading age, and simplification of governance-related terms and concepts. Conclusion The PC-PIT provides an innovative approach to address the complexity of organisational improvement in general practice and primary health care. This initial validation will be used to develop a suite of supporting, high-quality and free-to-access resources to enhance the use of the PC-PIT in general practice. Based on these findings, a national trial is now underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new range of programmable logic devices are revolutionizing the way complex digital hardware is designed and built all over the world. Being able to test these devices in order to validate and dynamically improve on the design is crucial. This paper describes a low-cost FPGA tester that can test SRAM based FPGAs in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design and development of a comprehensive digital protection scheme for applications in 25 KV a.c railway traction system. The scheme provides distance protection, detection of wrong phase coupling both in the lagging and leading directions, high set instantaneous trip and PT fuse failure. Provision is also made to include fault location and disturbance recording. The digital relaying scheme has been tried on two types of hardware platforms, one with PC/AT based hardware and the other with a custom designed standalone 16-bit microcontroller based card. Compared to the existing scheme, the operating time is around one cycle and the relaying algorithm has been optimised to minimise the number of computations. The prototype has been rigorously tested in the laboratory using a specially designed PC based relay test bench and the results are highly satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The localization and dispersion quality of as received NH2 terminated multiwall carbon nanotubes (MWNT-I) and ethylene diamine (EDA) functionalized MWNTs in melt mixed blends of polycarbonate ( PC) and poly(styrene-co-acrylonitrile) (SAN) were assessed in this study using rheo-electrical and electromagnetic interference (EMI) shielding measurements. In order to improve the dispersion quality and also to selectively localize MWNTs in the PC phase of the blends, EDA was grafted onto MWNTs by two different strategies like diazonium reaction of the para-substituted benzene ring of MWNTs with EDA ( referred to as MWNT-II) and acylation of carboxyl functionalized MWNTs with thionyl chloride ( referred to as MWNT-III). By this approach we could systematically vary the concentration of NH2 functional groups on the surface of MWNTs at a fixed concentration (1 wt%) in PC/SAN blends. XPS was carried to evaluate the % concentration of N in different MWNTs and was observed to be highest for MWNT-III manifesting in a large surface coverage of EDA on the surface of MWNTs. Viscoelastic properties and melt electrical conductivities were measured to assess the dispersion quality of MWNTs using a rheo-electrical set-up both in the quiescent as well as under steady shear conditions. Rheological properties revealed chain scission of PC in the presence of MWNT-III which is due to specific interactions between EDA and PC leading to smaller PC grafts on the surface of MWNTs. The observed viscoelastic properties in the blends were further correlated with the phase morphologies under quiescent and annealed conditions. Electromagnetic interference (EMI) shielding effectiveness in X and K-u-band frequencies were measured to explore these composites for EMI shielding applications. Interestingly, MWNT-II showed the highest electrical conductivity and EMI shielding in the blends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, multiwall carbon nanotubes (MWNTs) were chemically grafted onto dopamine anchored iron oxide (Fe3O4) nanoparticles via diazotization reaction to design electromagnetic (EM) shielding materials based on PC (polycarbonate)/SAN poly (styrene-co-acrylonitrile)] blends. A two step mixing protocol was adopted to selectively localize the nanoparticles in a given phase of the blends. In the first step, MWNT-g-Fe3O4 nanoparticles were solution blended with PC, followed by dilution with SAN during melt mixing in the subsequent step. This strategy, besides improving the quality of dispersion of MWNTs in the blends, facilitated enhanced EM interference shielding effectiveness (SE). Both, the MWNTs and the modified MWNTs, selectively localized in the PC phase and led to high electrical conductivity, in striking contrast to PC filled MWNT composites. The SE was measured on toroidal samples over a broad range of frequencies; X-band (8.2-12 GHz) and K-u-band (12-18 GHz). It was observed that the shielding mechanism mostly involved reflection in the blends with MWNTs, whereas absorption dominated in the case of blends with MWNT-g-Fe3O4. To realize the efficacy of this strategy, a few compositions were prepared by physical mixing MWNTs with Fe3O4 nanoparticles. Intriguingly, blends with MWNT-g-Fe3O4 nanoparticles manifested enhanced microwave absorption over physically mixed nanoparticles. An SE of -32.5 dB was observed (at 18 GHz) for MWNT (3 wt%)-g-Fe3O4 (3 vol%) in PC/SAN blends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanoscale ordering in a polymer blend structure is indispensable to obtain materials with tailored properties. It was established here that controlling the arrangement of nanoparticles, with different characteristics, in co-continuous PC/PVDF (polycarbonate/poly(vinylidene fluoride)) blends can result in outstanding microwave absorption (ca. 90%). An excellent reflection loss (RL) of ca. -71 dB was obtained for a model blend structure wherein the conducting (multiwall carbon nanotubes, MWNTs) and the magnetic inclusions (Fe3O4) are localized in PVDF and the dielectric inclusion (barium titanate, BT) is in PC. The MWNTs were modified using polyaniline, which facilitates better charge transport in the blends. Furthermore, by introducing surface active groups on BT nanoparticles and changing the macroscopic processing conditions, the localization of BT nanoparticles can be tailored, otherwise BT nanoparticles would localize in the preferred phase (PVDF). In this study, we have shown that by ordered arrangement of nanoparticles, the incoming EM radiation can be attenuated. For instance, when PANI-MWNTs were localized in PVDF, the shielding was mainly through reflection. Now by localizing the conducting inclusion and the magnetic lossy materials in PVDF and the dielectric materials in PC, an outstanding shielding effectiveness of ca. -37 dB was achieved where shielding was mainly through absorption (ca. 90%). Thus, this study clearly demonstrates that lightweight microwave absorbers can be designed using polymer blends as a tool.