463 resultados para palatal obturator
Resumo:
Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.
Resumo:
In cases of total or partial maxillectomies, the prosthetic rehabilitation is an effective alternative to minimize the sequelae left by surgical resection. The present study reports a clinical case of a 52-year-old patient who underwent partial maxillectomy, with upper lip involvement. The oronasal communication, resultant from surgical resection, did not allow the patient to return to her normal social life. Besides, the upper lip partial resection damaged her face's aesthetics. The proposed treatment was the confection of an upper lip prosthesis retained by a palatal obturator. The prosthesis insertion restored the patient's facial aesthetics, contributing not only to function, but also to psychosocial adaptation.
Resumo:
A 41-year-old man with cleft palate presented with a wide dehiscence and missing teeth. Six implants had been placed for fabrication of an overdenture, which was unsatisfactory. A bar was waxed and cast for connection to the implants; precision attachments were placed laterally for retention. A fixed partial denture was fabricated, and milled crowns were fabricated at the molar region to provide a guiding plane for insertion of a removable palatal obturator. Good swallowing and speech outcomes were achieved. This technique provided functional and esthetic benefits, enhanced oral hygiene, and improved the psychological condition of the patient.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To determine the immediate and longer-term effect(s) on tongue movement following the placement of an experimental opening through a palatal obturator (replicate of subject's prosthesis) worn by an adult male with an unrepaired cleft of the hard and soft palate.Methods: Tongue movements associated with an anterior experimental opening of 20 mm(2) were examined under three conditions: a control condition in which the subject wore the experimental obturator completely occluded, a condition immediately after drilling the experimental openings through the obturator, and a condition after 5 days in which the subject wore the experimental obturator with the experimental opening. An Electromagnetic Articulograph was used for obtaining tongue movements during speech.Results: the findings partly revealed that the immediate introduction of a perturbation to the speech system (experimental fistula) had a temporary effect on tongue movement. After sustained perturbation (for 5 days), the system normalized (going back toward control condition's behavior). Perceptual data were consistent with kinematic tongue movement direction in most of the cases.Conclusions: Although the immediate response can be interpreted as indicative of the subject's attempts to move the tongue toward the opening to compensate for air loss, the findings following a sustained perturbation indicate that with time, other physiological adjustments (such as respiratory adjustments, for example) may help reestablish the requirements of a pressure-regulating system.
Resumo:
Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning. © 2013 SPIE.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Aim: The aim of this report is to describe a quick and simple method of positioning retention magnets when deformed patients are rehabilitated with an oculopalpebral prostheses attached to a maxillary denture/obturator. Background: In patients with deformities requiring complex rehabilitations, the use of magnets is the most efficient means of providing combined prostheses with retention quality and stability. Usually prostheses with magnets are in sections and have a magnet in each section. When the sections are put together properly, the magnets are attracted to each other and retain the sections. Report: An edentulous patient presented for a post-surgical evaluation of a maxillofacial prosthesis used to repair a partial maxillectomy and left orbital exoneration which removed all adjacent tissues leaving an open communication between the oral, nasal, and orbital cavities. The proposed treatment plan included construction of a maxillary complete denture with a palatal obturator and a mandibular complete denture. Magnets were used to attach the oculopalpebral prosthesis to the maxillary denture/obturator. Summary: Use of retention magnets simplify the clinical and laboratorial phase, retains the denture, and makes it stable and comfortable for the patient. This treatment is one successful approach to the restoration of oral function and increases the patient’s quality of life.
Resumo:
Nos pacientes com defeitos ósseos palatinos congénitos ou adquiridos, quando a possibilidade de reconstrução cirúrgica não existe, poderá ter de se utilizar uma prótese obturadora palatina, com vista ao restabelecimento das funções do sistema estomatognático, tais como, a fonética, deglutição e mastigação. Contudo, esta necessidade não é só funcional mas também estética e psicológica, com vista a melhorar a qualidade de vida dos pacientes. As próteses obturadoras palatinas têm vindo a desenvolver há alguns séculos, com o aprimoramento das técnicas de confecção e materiais dentários que auxiliam na elaboração, cada vez mais eficientes, principalmente no que se refere a sua adaptação. Neste trabalho realizou-se uma revisão narrativa da literatura sobre próteses obturas palatinas utilizando as palavras-chave: maxillary birth bony defects; maxillary acquired bony defects; obturator prosthesis; prosthetic rehabilitation in maxillary defects; inflatable hollow obturator; prosthodontic rehabilitation of maxillary defects. Os objectivos deste trabalho foi o de conhecer os diferentes tipos de próteses obturadoras palatinas utilizadas na reabilitação de pacientes com defeitos ósseos palatinos, bem como, as suas indicações, contra-indicações, os cuidados de utilização e o protocolo clínico e laboratorial de confecção. As próteses obturadoras palatinas são assim uma solução possível na reabilitação funcional de um número grande de pacientes com defeitos ósseos palatinos, no entanto, o seu sucesso está dependente do correcto planeamento e da execução clínica e laboratorial cuidadosa.
Resumo:
Patients using obturator prostheses often present denture-induced stomatitis. In order to detect the presence of oral Candida albicans in patients with oronasal communications and to evaluate the effectiveness of a topical antifungal treatment, cytological smears obtained from the buccal and palatal mucosa of 10 adult patients, and from the nasal acrylic surface of their obturator prostheses were examined. A therapeutic protocol comprising the use of oral nystatin (Mycostatin®) and prosthesis disinfection with sodium hypochlorite was prescribed for all patients. Seven patients were positive for C. albicans in the mucosa, with 1 negative result for the prosthetic surface in this group of patients. Post-treatment evaluation revealed the absence of C. albicans on prosthesis surface and on the oral mucosa of all patients. The severity of the candidal infection was significantly higher in the palatal mucosa than in the buccal mucosa, but similar in the palatal mucosa and prosthesis surface, indicating that the mucosa underlying the prosthesis is more susceptible to infection. The therapeutic protocol was effective in all cases, which emphasizes the need for denture disinfection in order to avoid reinfection of the mucosa.
Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)
Resumo:
Objective: To assess, in patients undergoing glossectomy, the influence of the palatal augmentation prosthesis on the speech intelligibility and acoustic spectrographic characteristics of the formants of oral vowels in Brazilian Portuguese, specifically the first 3 formants (F1 [/a,e,u/], F2 [/o,o,u/], and F3 [/a,o/]). Design: Speech evaluation with and without a palatal augmentation prosthesis using blinded randomized listener judgments. Setting: Tertiary referral center. Patients: Thirty-six patients (33 men and 3 women) aged 30 to 80 (mean [SD], 53.9 [10.5]) years underwent glossectomy (14, total glossectomy; 12, total glossectomy and partial mandibulectomy; 6, hemiglossectomy; and 4, subtotal glossectomy) with use of the augmentation prosthesis for at least 3 months before inclusion in the study. Main Outcome Measures: Spontaneous speech intel-ligibility (assessed by expert listeners using a 4-category scale) and spectrographic formants assessment. Results: We found a statistically significant improvement of spontaneous speech intelligibility and the average number of correctly identified syllables with the use of the prosthesis (P < .05). Statistically significant differences occurred for the F1 values of the vowels /a,e,u/; for F2 values, there was a significant difference of the vowels /o,o,u/; and for F3 values, there was a significant difference of the vowels la,61 (P < .001). Conclusions: The palatal augmentation prosthesis improved the intelligibility of spontaneous speech and syllables for patients who underwent glossectomy. It also increased the F2 and F3 values for all vowels and the F I values for the vowels /o,o,u/. This effect brought the values of many vowel formants closer to normal.