753 resultados para packages
Resumo:
This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.
Resumo:
A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.
Resumo:
Toxoplasma gondii causes severe disease both to man and livestock and its detection in meat after slaughtering requires PCR or biological tests. Meat packages contain retained exudate that could be used for serology due to its blood content. Similar studies reported false negative assays in those tests. We standardized an anti-T. gondii IgG ELISA in muscle juices from experimentally infected rabbits, with blood content determination by cyanhemoglobin spectrophotometry. IgG titers and immunoblotting profiles were similar in blood, serum or meat juice, after blood content correction. These assays were adequate regardless of the storage time up to 120 days or freeze-thaw cycles, without false negative results. We also found 1.35% (1/74) positive sample in commercial Brazilian rabbit meat cuts, by this assay. The blood content determination shows ELISA of meat juice may be useful for quality control for toxoplasmosis monitoring. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The nutritional composition found in the laboratory and those present on labels of manufactured foods can differ significantly. The purpose of this study was to determine the nutritional composition of hamburgers and meatballs and compare them with your labels. The food analysis was performed following the Analytical Standards Institute`s Adolfo Lutz and energy content was determined by bomb calorimetry. Regarding the energy value, all the samples had values less than informed on the label. The content of lipids of hamburgers and meatballs ( except the beef) were lower than those reported on the label. The values of protein for the meatballs and chicken hamburger had lower values than those labels. Thus, the labels may overestimate as underestimate some nutritional values, leading to population erroneous information.
The structure of middle management remuneration packages: An application to Australian mine managers
Resumo:
This paper investigates the composition of remuneration packages for middle managers and relates the structure of remuneration contracts to firm-specific attributes. A statutorily defined position in a single industry is studied as an example of middle management. This allows us to control for differences in task complexity across managers and industry-induced factors that could determine differences in remuneration contracts. Higher-risk firms are expected to pay their mine managers a greater proportion of variable salaries and market and/or accounting-based compensation than low-risk firms. Results indicate that high-risk firms pay a higher proportion of variable salaries and more compensation based on market and/or accounting performance.
Resumo:
Relationships were examined between environmental conditions mediated by packaging and handling and the deterioration of harvested Geraldton waxflower cv. 'Fortune Cookie'. Disease severity plus flower and leaf drop caused by inoculation with Botrytis cinerea were reduced by lowering handling temperatures to 0, 5 or 5/20 degreesC alternated daily, versus 20 degreesC. They were also reduced by inhibition of ethylene action with a silver thiosulfate pulse pretreatment. Additionally, treatments that enhanced water loss, such as packing dry, keeping forced air-cooling holes open and strategic placement of extra ventilation holes may also reduce disease severity and flower plus leaf fall. Inclusion of KMnO4-based Bloomfresh ethylene scrubbing sachets in packages did not reduce disease severity or lessen flower plus leaf fall. Thus, deterioration of waxflower packaged in commercial cartons can be minimised by keeping temperatures low, packing plant material dry, use of cartons with strategically placed ventilation holes and/or pretreatment with silver thiosulfate.
Resumo:
Acioly, A. S. G., Soares, M. M., & Arezes, P. M. (2015). Possible uses of augmented reality as a tool for guidance of users of packages. Paper presented at the Occupational Safety and Hygiene III - Selected Extended and Revised Contributions from the International Symposium on Safety and Hygiene.
Resumo:
Problema apresentado pelo Hospital de Braga no 109th European Study Group with Industry 10 a 15 de maio de 2015. Departamento de Produção e Sistemas Escola de Engenharia da Universidade do Minho Guimarães Portugal 24 de julho de 2015
Resumo:
Department of Health and Children Evaluation of Home Care Packages Click here to download PDF 1.6mb
Resumo:
Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, ωc=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (ρc). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (ρc=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.
Resumo:
Aim. Several software packages (SWP) and models have been released for quantification of myocardial perfusion (MP). Although they all are validated against something, the question remains how well their values agree. The present analysis focused on cross-comparison of three SWP for MP quantification of 13N-ammonia PET studies. Materials & Methods. 48 rest and stress MP 13N-ammonia PET studies of hypertrophic cardiomyopathy (HCM) patients (Sciagrà et al., 2009) were analysed with three SW packages - Carimas, PMOD, and FlowQuant - by three observers blinded to the results of each other. All SWP implement the one-tissue-compartment model (1TCM, DeGrado et al. 1996), and first two - the two-tissue-compartment model (2TCM, Hutchins et al. 1990) as well. Linear mixed model for the repeated measures was fitted to the data. Where appropriate we used Bland-Altman plots as well. The reproducibility was assessed on global, regional and segmental levels. Intraclass correlation coefficients (ICC), differences between the SWPs and between models were obtained. ICC≥0.75 indicated excellent reproducibility, 0.4≤ICC<0.75 indicated fair to good reproducibility, ICC<0.4 - poor reproducibility (Rosner, 2010). Results. When 1TCM MP values were compared, the SW agreement on global and regional levels was excellent, except for Carimas vs. PMOD at RCA: ICC=0.715 and for PMOD vs. FlowQuant at LCX:ICC=0.745 which were good. In segmental analysis in five segments: 7,12,13, 16, and 17 the agreement between all SWP was excellent; in the remaining 12 segments the agreement varied between the compared SWP. Carimas showed excellent agreement with FlowQuant in 13 segments and good in four - 1, 5, 6, 11: 0.687≤ICCs≤0.73; Carimas had excellent agreement with PMOD in 11 segments, good in five_4, 9, 10, 14, 15: 0.682≤ICCs≤0.737, and poor in segment 3: ICC=0.341. PMOD had excellent agreement with FlowQuant in eight segments and substantial-to-good in nine_1, 2, 3, 5, 6,8-11: 0.585≤ICCs≤0.738. Agreement between Carimas and PMOD for 2TCM was good at a global level: ICC=0.745, excellent at LCX (0.780) and RCA (0.774), good at LAD (0.662); agreement was excellent for ten segments, fair-to-substantial for segments 2, 3, 8, 14, 15 (0.431≤ICCs≤0.681), poor for segments 4 (0.384) and 17 (0.278). Conclusions. The three SWP used by different operators to analyse 13N-ammonia PET MP studies provide results that agree well at a global level, regional levels, and mostly well even at a segmental level. Agreement is better for 1TCM. Poor agreement at segments 4 and 17 for 2TCM needs further clarification.
Resumo:
Työn tarkoituksena oli testata jo tutkimuskeskuksella käytössä ollutta ja tutkimuskeskukselle tässä työssä kehitettyä pakkauksen vesihöyrytiiveyteen liittyvää mittausmenetelmää. Saatuja tuloksia verrattiin keskenään sekä materiaalista mitattuihin arvoihin. Elintarvikepakkauksia tutkittiin myös kosteussensoreiden, säilyvyyskokeen sekä kuljetussimuloinnin avulla. Optimoinnilla tutkittiin pakkauksen muodon vaikutusta vesihöyrytiiveyteen. Pakkauksen vesihöyrynläpäisyn mittaamiseen kehitetty menetelmä toimi hyvin ja sen toistettavuus oli hyvä. Verrattaessa sitä jo olemassa olleeseen menetelmään tulokseksi saatiin, että uusi menetelmä oli nopeampi ja vaati vähemmän työaikaa, mutta molemmat menetelmät antoivat hyviä arvoja rinnakkaisille näytteille. Kosteussensoreilla voitiin tutkia tyhjän pakkauksen sisällä olevan kosteuden muutoksia säilytyksen aikana. Säilyvyystesti tehtiin muroilla ja parhaan vesihöyrysuojan antoivat pakkaukset joissa oli alumiinilaminaatti- tai metalloitu OPP kerros. Kuljetustestauksen ensimmäisessä testissä pakkauksiin pakattiin muroja ja toisessa testissä nuudeleita. Kuljetussimuloinnilla ei ollutvaikutusta pakkausten sisäpintojen eheyteen eikä siten pakkausten vesihöyrytiiveyteen. Optimoinnilla vertailtiin eri muotoisten pakkausten tilavuus/pinta-ala suhdetta ja vesihöyrytiiveyden riippuvuutta pinta-alasta. Optimaalisimmaksi pakkaukseksi saatiin pallo, jonka pinta-ala oli pienin ja materiaalin sallima vesihöyrynläpäisy suurin ja vesihöyrybarrierin määrä pienin.
Resumo:
High barrier materiaaleilla pyritään pidentämään pakattujen elintarvikkeiden hyllyikää. Barrierin tärkein tehtävä on elintarvikkeen suojaaminen hapelta ja kosteudelta. Alumiinin käyttöä barriermateriaalina pyritään vähentämään korvaamalla alumiini polymeereillä, jotka täyttävät elintarvikkeiden asettamat korkeat säilyvyysvaatimukset. Etyylivinyylialkoholin (EVOH) hapenläpäisevyys on kuivissa olosuhteissa alhaisin kaupallisista muovilaaduista. EVOH tarjoaa myös erinomaisen suojan muita kaasuja, rasvoja, hajuja ja aromeja vastaan ja sitä on helppo prosessoida. Polyamideilla on erinomainen kaasutiiveys sekä hyvä lujuus ja sitkeys. Eri muovilaatuja sekoittamalla voidaan vähentää hapenläpäisyä ja parantaa prosessointia. Polyolefiineja käytetään yleisesti päällystysmateriaaleina, koska ne suojaavat tuotetta erinomaisesti kosteudelta. Hapenläpäisyllä tarkoitetaan hapen kulkeutumista materiaalin läpi joko permeaation kautta tai reikien ja vuotojen läpi. Kaasun permeoitumiseen materiaalin läpi vaikuttavat materiaalin vapaa tilavuus, kiteisyysaste, orientaatio, substituointi, suhteellinen kosteus, lämpötila, barrierkerroksen paksuus, paine-ero ja permeoituvan molekyylin ominaisuudet. Kokeellisessa osassa analysoitiin ja vertailtiin kartonkipohjaisia mehutölkkejä, joissa käytettävät high barrier materiaalit olivat EVOH ja PA. Kartonkipohjaisia alumiinitölkkejä käytettiin referenssinä. Pakkausten hapenläpäisevyysmittauksissa saatiin samasta näytteestä toistettavia tuloksia, vaikka vuotomittauksissa saadut tulokset eivät olleet vertailukelpoisia hapenläpäisytulosten kanssa. Tölkkien valmistus vaikutti oleellisesti pakkausten tiiveysominaisuuksiin. Hapenläpäisy vuotojen ja reikien läpi oli merkittävämpää kuin hapenläpäisy materiaalin läpi. Pakkausten tiiveysominaisuuksia analysoitiin mittaamalla appelsiinimehun askorbiini-happopitoisuus. Askorbiinihapon hajoaminen mitattiin koetölkkeihin pakatusta appelsiinimehusta, ja lämpötilan, valon ja hapen vaikutusta askorbiinihapon hajoamiseen tutkittiin 12 viikon ajan. Lämpötilalla oli suurin vaikutus askorbiinihapon hajoamiseen huolimatta käytetystä pakkausmateriaalista.
Resumo:
One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.