986 resultados para operating characteristics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cover title.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Purdue Research Foundation. Research project no.1717. Project Ae-33. This research was supported by the McDonnell Aircraft Corporation under Contract no. 6140-20 P. O. 7S4899-R."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis "COMPARATIVE ANALYSIS OF EFFICIENCY AND OPERATING CHARACTERISTICS OF AUTOMOTIVE POWERTRAIN ARCHITECTURES THROUGH CHASSIS DYNAMOMETER TESTING" was completed through a collaborative partnership between Michigan Technological University and Argonne National Laboratory under a contractual agreement titled "Advanced Vehicle Characterization at Argonne National Laboratory". The goal of this project was to investigate, understand and document the performance and operational strategy of several modern passenger vehicles of various architectures. The vehicles were chosen to represent several popular engine and transmission architectures and were instrumented to allow for data collection to facilitate comparative analysis. In order to ensure repeatability and reliability during testing, each vehicle was tested over a series of identical drive cycles in a controlled environment utilizing a vehicle chassis dynamometer. Where possible, instrumentation was preserved between vehicles to ensure robust data collection. The efficiency and fuel economy performance of the vehicles was studied. In addition, the powertrain utilization strategies, significant energy loss sources, tailpipe emissions, combustion characteristics, and cold start behavior were also explored in detail. It was concluded that each vehicle realizes different strengths and suffers from different limitations in the course of their attempts to maximize efficiency and fuel economy. In addition, it was observed that each vehicle regardless of architecture exhibits significant energy losses and difficulties in cold start operation that can be further improved with advancing technology. It is clear that advanced engine technologies and driveline technologies are complimentary aspects of vehicle design that must be utilized together for best efficiency improvements. Finally, it was concluded that advanced technology vehicles do not come without associated cost; the complexity of the powertrains and lifecycle costs must be considered to understand the full impact of advanced vehicle technology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work proposes a new approach using a committee machine of artificial neural networks to classify masses found in mammograms as benign or malignant. Three shape factors, three edge-sharpness measures, and 14 texture measures are used for the classification of 20 regions of interest (ROIs) related to malignant tumors and 37 ROIs related to benign masses. A group of multilayer perceptrons (MLPs) is employed as a committee machine of neural network classifiers. The classification results are reached by combining the responses of the individual classifiers. Experiments involving changes in the learning algorithm of the committee machine are conducted. The classification accuracy is evaluated using the area A. under the receiver operating characteristics (ROC) curve. The A, result for the committee machine is compared with the A, results obtained using MLPs and single-layer perceptrons (SLPs), as well as a linear discriminant analysis (LDA) classifier Tests are carried out using the student's t-distribution. The committee machine classifier outperforms the MLP SLP, and LDA classifiers in the following cases: with the shape measure of spiculation index, the A, values of the four methods are, in order 0.93, 0.84, 0.75, and 0.76; and with the edge-sharpness measure of acutance, the values are 0.79, 0.70, 0.69, and 0.74. Although the features with which improvement is obtained with the committee machines are not the same as those that provided the maximal value of A(z) (A(z) = 0.99 with some shape features, with or without the committee machine), they correspond to features that are not critically dependent on the accuracy of the boundaries of the masses, which is an important result. (c) 2008 SPIE and IS&T.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction. Hepatic steatosis due to non-alcoholic fatty liver disease is associated with obesity, dyslipidemia, insulin resistance, and type 2 diabetes. The Finnish Diabetes Risk Score (FINDRISC) is a prognostic screening tool to detect people at risk for type 2 diabetes without the use of any blood test. The objective of this study was to evaluate whether FINDRISC can also be used to screen for the presence of hepatic steatosis. Patients and methods. Steatosis was determined by ultrasound. The study sample consisted of 821 non-diabetic subjects without previous hepatic disease; 81% were men (mean age 45 +/- 9 years) and 19% women (mean age 41 +/- 10 years). Results. Steatosis was present in 44% of men and 10% of women. The odds ratio for one unit increase in the FINDRISC associated with the risk of steatosis was 1.30 (95% CI 1.25-1.35), similar for men and women. The area under the receiver operating characteristics curve for steatosis was 0.80 (95% CI 0.77-0.83); 0.80 in men (95% CI 0.77-0.83) and 0.83 (95% CI 0.73-0.93) in women. Conclusions. Our data suggest that the FINDRISC could be a useful primary screening tool for the presence of steatosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Real time myocardial contrast echocardiography (RTMCE) is an emerging imaging modality for assessing myocardial perfusion that allows for noninvasive quantification of regional myocardial blood flow (MBF). Aim: We sought to assess the value of qualitative analysis of myocardial perfusion and quantitative assessment of myocardial blood flow (MBF) by RTMCE for predicting regional function recovery in patients with ischemic heart disease who underwent coronary artery bypass grafting (CABG). Methods: Twenty-four patients with coronary disease and left ventricular systolic dysfunction (ejection fraction < 45%) underwent RTMCE before and 3 months after CABG. RTMCE was performed using continuous intravenous infusion of commercially available contrast agent with low mechanical index power modulation imaging. Viability was defined by qualitative assessment of myocardial perfusion as homogenous opacification at rest in >= 2 segments of anterior or >= 1 segment of posterior territory. Viability by quantitative assessment of MBF was determined by receiver-operating characteristics curve analysis. Results: Regional function recovery was observed in 74% of territories considered viable by qualitative analysis of myocardial perfusion and 40% of nonviable (P = 0.03). Sensitivity, specificity, positive and negative predictive values of qualitative RTMCE for detecting regional function recovery were 74%, 60%, 77%, and 56%, respectively. Cutoff value of MBF for predicting regional function recovery was 1.76 (AUC = 0.77; 95% CI = 0.62-0.92). MBF obtained by RTMCE had sensitivity of 91%, specificity of 50%, positive predictive value of 75%, and negative predictive value of 78%. Conclusion: Qualitative and quantitative RTMCE provide good accuracy for predicting regional function recovery after CABG. Determination of MBF increases the sensitivity for detecting hibernating myocardium. (Echocardiography 2011;28:342-349).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The delay in the diagnosis of infections can be deleterious in renal transplant recipients. Thus, laboratory tests leading to an earlier diagnosis are very useful for these patients. Purpose: To assess the behavior of C-reactive protein (CRP) in renal transplant recipients with a diagnosis of cytomegalovirus (CMV) infection, tuberculosis (TB) and bacterial infection (BI). Methods: A retrospective analysis of 129 patients admitted at our hospital, from 2006 to 2008 because of CMV, TB or BI, was carried out. Appropriate statistical analysis was done and values were expressed as medians, range. Results: When CRP levels were compared among the groups with CMV disease, TB or BI, the group with CMV disease presented lower levels of CRP (18.4 mg/L, 0.28-44 mg/L) than the TB and BI (p < 0.05) groups. The area under the receiver-operating characteristics curve, distinguishing CMV disease from TB/BI, was 0.96 (p < 0.0001), resulting in 100% sensitivity and 90.63% specificity to detect CMV disease when CRP < 44.5 mg/L. The subgroup analysis of CMV infection showed increasing levels of CRP (0.28, 16 and 29.5 mg/L) in the asymptomatic, symptomatic and invasive disease subgroups, respectively (p < 0.05). Conclusion: The measurement of CRP levels may be a useful tool for differentiating CMV infection from the other types (bacterial or TB) of infection in kidney transplant recipients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Hypertension, a risk factor for cardiovascular diseases, and obesity are becoming a health problem in many developed and developing countries, as Brazil. Although hypertension and obesity are both closely associated, there is no universal anthropometric marker of this association. This is probably due to distinct population characteristics, and in the case of Brazil, the highly heterogeneous population. We evaluated which anthropometric measurement closely relates to high blood pressure in a sample of Brazilian factory workers. METHODS A cross-sectional study was designed. In this study, multiple logistic regression and receiver operating characteristics analysis were performed in order to obtain the precise relevance of each anthropometric measurement as a blood pressure marker. Nine hundred and thirteen men, 36 +/- 8 years-old, were submitted to a standardized questionnaire of demographic and risk factors knowledge, anthropometric and conventional blood pressure measurements were taken, and blood sample evaluations of glucose, total cholesterol, LDL-Cholesterol, and triglycerides were performed. RESULTS Overweightness or obesity was identified in 64, 11.1% were smokers and hypertension was detected in 29.2% of the participants. A linear correlation was significant (P < 0.001) between both the systolic and diastolic blood pressure and all anthropometric measurements, except for the systolic blood pressure and waist-to-hip ratio. Waist circumference (WC) was the only independent anthropometric measurement related to hypertension. Hypertensive patients presented all anthropometric measurements larger than normotensives. CONCLUSIONS Age and WC were the only independent predictors of hypertension, indicating that this simple measurement may be useful as a marker of hypertension in the Brazilian male, younger adult population. Am J Hypertens 2009; 22:980-984 (C) 2009 American Journal of Hypertension, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The Edinburgh Postnatal Depression Scale (EPDS) has been validated and used extensively in screening for depression in new mothers, both in English speaking and non-English speaking communities. While some studies have reported the use of the EPDS with Fathers, none have validated it for this group, and thus the appropriate cut-off score for screening for depression or anxiety caseness for this population is not known. Method: Couples were recruited antenatally and interviewed at six weeks postpartum. EPDS scores and distress caseness (depression or anxiety disorders) for 208 fathers and 230 mothers were determined using the Diagnostic Interview Schedule. Results: Analyses of the EPDS for fathers using distress caseness (depression or anxiety disorders) as the criterion shows that a cut-off of 5/6 has optimum receiver operating characteristics. Furthermore acceptable reliability (split-half and internal consistency) and validity (concurrent) coefficients were obtained. For mothers the optimum cut-off screening value to detect distress caseness was 7/8. Item analysis revealed that fathers endorsed seven of the ten items at lower rates to mothers, with the most significant being that referring to crying. Conclusions: The EPDS is a reliable and valid measure of mood in fathers. Screening for depression or anxiety disorders in fathers requires a two point lower cut-off than screening for depression or anxiety in mothers, and we recommend this cut-off to he 5/6. (C) 2001 Elsevier Science B.V. All rights reserved.