862 resultados para ocular ultrasonography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the advent of high frequency transducers, the use of ocular ultrasound has become widely used because it provides definitions of major ocular structures. This diagnostic tool is useful in the evaluation of ophthalmic injuries, and also used for qualitative and quantitative evaluation of intraocular and orbital lesions. It is a noninvasive, safe and fast, easy to use and can be performed in an awake animal. The ocular ultrasonography is indicated in cases of ocular opacity, when the ophthalmic examination cannot be done, and in eyes with ocular trauma or suspected orbital disease. Ultrasound biomicroscopy (UBM) is a diagnostic tool with high cost and sedation or general anesthesia is necessary, but has the advantage of evaluating structures poorly defined or visualized in the anterior segment of the eye. Therefore, this paper aims to show the importance of ocular ultrasonography and UBM to veterinary practitioners, and to demonstrate its advantages and indications in ophthalmic routine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The authors present the unique clinical features of cavitary uveal melanoma. Design: Retrospective chart review. Participants: Eight patients with cavitary uveal melanoma. Main Outcome Measures: The clinical, ultrasonographic, and histopathologic features of eight patients with cavitary melanoma of the ciliary body were studied. Results: In all eyes there was a brown ciliary body mass that blocked transmission of light on trans-scleral transillumination. Ocular ultrasonography revealed a large, single hollow cavity (unilocular 'pseudocyst') in five cases and multiple hollow cavities (multilocular 'pseudocyst') in three cases. The cavity occupied a mean of 55% of the entire mass thickness (range, 31%-79%). In five cases, a basal uveal mass was noted on ultrasonography. Four patients underwent tumor resection; one had enucleation, and three had 1251 radioactive plaque treatment. In the five cases confirmed histopathologically, the cavitation was empty, contained erythrocytes, serous fluid, and/or pigment-laden macrophages. In no case was the cavity lined by necrotic tumor, endothelial cells, or epithelial cells. Conclusion: Ciliary body melanoma can develop an intralesional cavity resembling an intraocular cyst. The presence of a solid mass at the base and a thick wall surrounding the cavity can assist in the differentiation of cavitary melanoma from benign cyst.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conhecer o aspecto e as dimensões de olhos de cabras facilita o uso da ultrassonografia na avaliação de doenças oculares. O objetivo do presente trabalho foi o de avaliar os achados ultrassonográficos e ecobiométricos em olhos de cabras adultas. Ultrassonogramas nos modos A e B foram realizados em 30 caprinos adultos (60 olhos) (n=15 fêmeas intactas e n=15 machos castrados). O exame ultrassonográfico foi realizado após a instilação de colírio anestésico. Gel a base de água foi utilizado sobre o transdutor de 20 MHz posicionado-o de forma longitudinasobre a córneal, até que imagens no modo B estivessem de acordo com os ecos gerados pelo modo A. Utilizou-se análise estatística para se comparar os achados ecobiométricos entre os sexos (p<0,05). As médias com seus respectivos desvios padrões das estruturas oculares em machos e fêmeas foram, respectivamente, 3,46±0,55, 3,33±0,46mm (profundidade da câmara anterior); 8,60±0,34, 8,65±0,39mm (espessura da lente); 11,34±0,61, 11,39±0,66mm (profundidade da câmara vítrea) e 23,43±0,92, 23,39±0.86mm (comprimento axial do bulbo ocular). Não foi observada diferença significativa entre os olhos direito e esquerdo, assim como entre machos e fêmeas (p>0,05). O aspecto ultrassonográfico de olhos de cabras se assemelha com o de outras espécies domésticas e silvestres.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PurposeUltrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length.MethodSixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease.Result and DiscussionThe measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 +/- 0.03 cm, D2 0.35 +/- 0.02 cm, D3 0.73 +/- 0.04 cm and the axial length 1.26 +/- 0.06 cm. In the right eye D1 0.17 +/- 0.02 cm, D2 0.34 +/- 0.02 cm, D3 0.74 +/- 0.03 cm and the axial length 1.25 +/- 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The practice of covering in herds is often used in Crioulo breeding farms, thus not allowing the determination of ovulation dates and the early detection of pregnancies. This fact complicates the estimation of gestational age after 70 days of conception. This study aimed to evaluate the diameter of the fetal orbits of Crioulo mares to develop a formula to estimate a gestational date. Measurements of 164 fetal ocular orbits were performed in 124 Crioulo mares with gestational ages ranging between 119 and 341 days. The current study observed a linear growth pattern of Crioulo fetal orbits up to 341 days of gestation. Thus, obtaining a suitable linear regression model to determine the gestational age of Crioulo mares based on fetal ocular orbit diameter measure is possible. The obtained model was y = 8.3756x + 11.90, where y represents the gestational age in days, and x represents the diameter of the fetal ocular orbit in millimeters. This formula had anr2 of 0.985 (P < .001). We conclude that this model allows researchers and veterinarians to accurately estimate the gestational age of Crioulo mares between 4 and 11months of pregnancy. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Avaliou-se 31 cães saudáveis, sem raça definida, sendo 10 machos e 21 fêmeas, com 8 meses a 7 anos de idade e peso de1,5-28 kg. Inicialmente foram mensurados os diâmetros fronto-occiptal (DFO) e bizigomático (DBZ) do crânio com o auxílio de um paquímetro. A ultra-sonografia transpalpebral em modo-B foi realizada para mensurar as estruturas do bulbo ocular, conforme se segue: D1- espessura da córnea; D2- distância entre o ponto central da imagem da córnea e a da cápsula anterior do cristalino (câmara anterior); D3- distância entre o ponto central da imagem da córnea e a da cápsula posterior do cristalino; D4- espessura do cristalino, que corresponde a distância entre a imagem da cápsula anterior e a cápsula posterior do cristalino; D5- diâmetro do cristalino, distância entre as imagens dos pólos do cristalino; D6– área do cristalino; D7- câmara vítrea, distância entre a imagem da cápsula posterior do cristalino e a retina; D8- distância entre a cápsula anterior do cristalino e a retina; D9- distância entre a imagem da córnea e a retina. Com exceção da D4, houve efeito dos DFO e DBZ sobre as medidas das estruturas internas do BO. A análise de regressão linear entre as medidas das estruturas do bulbo ocular e os DFO e DBZ foram significativas para D1, D2, D3, D4, D5, D6, D7, D8 e D9.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ObjectiveThis study aimed to evaluate the benefit and specifically the feasibility of using ultrasound in ophthalmologic periconal block, and the occurrence of complications.Study designProspective experimental study.AnimalsTen healthy New Zealand White rabbits (6-8months of age), weighing 2.0-3.5kg.MethodsRabbits were anesthetized by intramuscular injection of acepromazine (1mgkg(-1)), ketamine (30mgkg(-1)) and xylazine (3mgkg(-1)). Ultrasound-assisted periconal block with lidocaine was performed on 18 eyes. Intraocular pressure was measured by applanation tonometry whereas corneal sensitivity was assessed using an esthesiometer, before and after each periconal anesthesia.ResultsIn all 18 eyes, it was possible to adequately visualize the needle shaft within the periconal space, as well as muscular cone, optic nerve and local anesthetic solution spread. Lidocaine 2% without epinephrine (0.790.19mL) was injected into the periconal space. There was no statistical difference between the intraocular pressure (meanSD) measured before (10.9 +/- 2.9mmHg) and after (11.9 +/- 3.8mmHg) the periconal anesthesia (p=0.38). The effectiveness of the ultrasound-assisted technique was shown according to the values for corneal sensitivity, assessed before and after periconal anesthesia (p<0.0001). Complications were not observed in this study.ConclusionsEye ultrasonography allowed visualization of all anatomic structures necessary to perform a periconal block, as well as the needle insertion and anesthetic spread in real time. Further studies are required to prove the real potential of ultrasound for reducing the incidence of complications associated with ophthalmic blocks, especially when anatomic disorders of the eye could potentially increase the risk.Clinical relevanceUltrasonography is a painless, noninvasive tool that may improve safety of ophthalmic regional blocks, potentially by reducing the prevalence of globe perforation or penetration of the optic nerve associated with the needle-based techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. Methods: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. Results: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). Conclusions: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: (1) To describe the ultrasonographic appearance of multiple congenital ocular anomalies (MCOA) in the eyes of horses with the PMEL17 (Silver) mutant gene. (2) To compare the accuracy of B-mode ocular ultrasound to conventional direct ophthalmoscopy. ANIMALS STUDIED: Sixty-seven Comtois and 18 Rocky Mountain horses were included in the study. PROCEDURES: Horses were classified as being carriers or noncarriers of the PMEL17 mutant allele based on coat color or genetic testing. Direct ophthalmoscopy followed by standardized ultrasonographic examination was performed in all horses. RESULTS: Seventy-five of 85 horses (88.24%) carried at least one copy of the Silver mutant allele. Cornea globosa, severe iridal hypoplasia, uveal cysts, cataracts, and retinal detachment could be appreciated with ultrasound. Carrier horses had statistically significantly increased anterior chamber depth and decreased thickness of anterior uvea compared with noncarriers (P < 0.05). Uveal cysts had a wide range of location and ultrasonographic appearances. In 51/73 (69.86%) carrier horses, ultrasound detected ciliary cysts that were missed with direct ophthalmoscopy. CONCLUSIONS: In this study, ultrasonography was useful to identify uveal cysts in PMEL17 mutant carriers and to assess anterior chamber depth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements (autokeratometry, A-scan ultrasonography and video ophthalmophakometry) of ocular surface radii, axial separations and alignment were made in the horizontal meridian of nine emmetropes (aged 20-38 years) with relaxed (cycloplegia) and active accommodation (mean ± 95% confidence interval: 3.7 ± 1.1 D). The anterior chamber depth (-1.5 ± 0.3 D) and both crystalline lens surfaces (front 3.1 ± 0.8 D; rear 2.1 ± 0.6 D) contributed to dioptric vergence changes that accompany accommodation. Accommodation did not alter ocular surface alignment. Ocular misalignment in relaxed eyes is mainly because of eye rotation (5.7 ± 1.6° temporally) with small amounts of lens tilt (0.2 ± 0.8° temporally) and decentration (0.1 ± 0.1 mm nasally) but these results must be viewed with caution as we did not account for corneal asymmetry. Comparison of calculated and empirically derived coefficients (upon which ocular surface alignment calculations depend) revealed that negligible inherent errors arose from neglect of ocular surface asphericity, lens gradient refractive index properties, surface astigmatism, effects of pupil size and centration, assumed eye rotation axis position and use of linear equations for analysing Purkinje image shifts. © 2004 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A new commercially available optical low coherence reflectometry device (Lenstar, Haag-Streit or Allegro Biograph, Wavelight) provides high-resolution non-contact measurements of ocular biometry. The study evaluates the validity and repeatability of these measurements compared with current clinical instrumentation. Method: Measurements were taken with the LenStar and IOLMaster on 112 patients aged 41–96 years listed for cataract surgery. A subgroup of 21 patients also had A-scan applanation ultrasonography (OcuScan) performed. Intersession repeatability of the LenStar measurements was assessed on 32 patients Results: LenStar measurements of white-to-white were similar to the IOLMaster (average difference 0.06 (SD 0.03) D; p?=?0.305); corneal curvature measurements were similar to the IOLMaster (average difference -0.04 (0.20) D; p?=?0.240); anterior chamber depth measurements were significantly longer than the IOLMaster (by 0.10 (0.40) mm) and ultrasound (by 0.32 (0.62) mm; p<0.001); crystalline lens thickness measurements were similar to ultrasound (difference 0.16 (0.83) mm, p?=?0.382); axial length measurements were significantly longer than the IOLMaster (by 0.01 (0.02) mm) but shorter than ultrasound (by 0.14 (0.15) mm; p<0.001). The LensStar was unable to take measurements due to dense media opacities in a similar number of patients to the IOLMaster (9–10%). The LenStar biometric measurements were found to be highly repeatable (variability =2% of average value). Conclusions: Although there were some statistical differences between ocular biometry measurements between the LenStar and current clinical instruments, they were not clinically significant. LenStar measurements were highly repeatable and the instrument easy to use.