This study was conducted to measure the levels of 23 PCB congeners and 6 organochlorine pesticides (OCPs) in human milk and three food types collected from Luqiao and Pingqiao in Zhejiang Province, China. An effort was also made to explore the potential health risk for the mothers and breast-fed infants living in these two localities. Luqiao was selected as the sampling site because it is the largest place for the disassembly of obsolete transformers and electrical waste in China. Pingqiao, located 100 kin NW of Luqiao, is not known to be a place for any electronic or electrical waste and hence was chosen as the control site. Both localities are important agricultural places in the province. The organochlorines were measured in the samples using the GC-PECD technique. Micro-EROD bioassay method was also used as a complement of the chemical analysis to estimate the TEQ levels of dioxin-like PCBs in human milk. The data showed that the human milk, rice, hen egg, and fish samples from Luqiao were more heavily contaminated with PCBs than those from Pingqiao, suggesting that the mothers and their breast-fed infants in Luqiao tended to receive greater exposure to PCBs than those living in Pingqiao. The OCP levels in the two localities were found comparable, suggesting that the major source of contamination with these pesticides was from their agricultural uses. Significant correlation (R-2 = 0.87, P < 0.001) of PCB TEQs was found between the bioassay and chemical analysis method, suggesting that micro-EROD is an effective method for comprehensive determination of TEQ levels in human milk. Comparison with literature data showed that the PCB levels in milk samples from Luqiao were significantly higher than those from localities in other Chinese provinces and comparable to those in developed or industrialized countries. (c) 2007 Published by Elsevier B.V.
Resumo:
Prenatal exposures to persistent organic pollutants were assessed using the levels of PCBs and organochlorine pesticides (OCPs) measured in cord blood and meconium samples from Luqiao and two other localities of the Zhejiang province in China. Luqiao is a town with the largest site for disassembly of PCB-containing obsolete transformers and electrical waste in China. The other two localities Pingqiao (100 km NW of Luqiao) and Lin'an (500 km NW of Luqiao) are towns without known electronic or electrical waste sites. A total of 23 PCB congeners (including 12 dioxin-like) and 6 OCPs were measured using the traditional GC-mu ECD technique. Micro-EROD bioassay was additionally used to measure TCDD-based TEQ levels of the 12 dioxin-like PCBs. Significant correlations were found between the TEQs measured by the two methods, supporting the application of micro-EROD as a practical toot for complementing the chemical analysis. The data showed that beta-HCH, p,p'-DDE, and 6 PCB congeners (101, 138 153, 180, 183, and 187) were the predominant pollutants, with PCB 138 being the best indicator (predictor) for total PCB levels. Cord blood and meconium from Luqiao have higher levels of PCBs than those from the other two localities, suggesting that a disassembly site for electronic and electric waste would provide an environment for greater exposure to these chemicals. The cord blood or meconium levels of beta-HCH, though likewise considerably high, were comparable in the three localities. Similar findings were observed for p,p'-DDE. Pollution by these OCPs might have come from past use of agricultural pesticides in the three localities. (c) 2007 Published by Elsevier B.V.
Resumo:
Samples of groundwater, river water, river sediment, paddy soil, rice seeds, hen eggs, fish, umbilical cord blood, and newborn meconium were collected from October 2002 to October 2003 near a large site in China used for the disassembly of obsolete transformers and other electronic or electrical waste. Six indicator PCB congeners, three non-ortho dioxin-like PCB congeners, and six organochlorine pesticides were determined in the samples by GC with electron capture detector. The results demonstrated that the local environment and edible foods had been seriously polluted by toxic PCBs and organochlorine pesticides. The actual daily intakes (ADIs) of these pollutants were estimated for local residents living in the area. The intake data showed that the contents of PCBs in these local residents were substantial, as the ADI estimates greatly exceed the reference doses set by the World Health Organization and the United States Agency for Toxic Substances and Disease Registry. The presence of the indicator PCB congeners in the cord blood and the meconium samples, as well as significant correlations (r(2) > 0.80, p < 0.05) between these levels, suggests a potential biotransfer of these indicators from mothers to their newborns. This preliminary study showed that obsolete transformers and other electronic or electrical waste can be an important source for the emission of persistent organic pollutants into the local environment, such as through leakage, evaporation, runoff, and leaching. Contamination from this source appears to have reached the level considered to be a serious threat to environmental and human health around the disassembly site.
Resumo:
Power transformers are one of the most important and costly equipment in power generation, transmission and distribution systems. Current average age of transformers in Australia is around 25 years and there is a strong economical tendency to use them up to 50 years or more. As the transformers operate, they get degraded due to different loading and environmental operating stressed conditions. In today‘s competitive energy market with the penetration of distributed energy sources, the transformers are stressed more with minimum required maintenance. The modern asset management program tries to increase the usage life time of power transformers with prognostic techniques using condition indicators. In the case of oil filled transformers, condition monitoring methods based on dissolved gas analysis, polarization studies, partial discharge studies, frequency response analysis studies to check the mechanical integrity, IR heat monitoring and other vibration monitoring techniques are in use. In the current research program, studies have been initiated to identify the degradation of insulating materials by the electrical relaxation technique known as dielectrometry. Aging leads to main degradation products like moisture and other oxidized products due to fluctuating thermal and electrical loading. By applying repetitive low frequency high voltage sine wave perturbations in the range of 100 to 200 V peak across available terminals of power transformer, the conductive and polarization parameters of insulation aging are identified. An in-house novel digital instrument is developed to record the low leakage response of repetitive polarization currents in three terminals configuration. The technique is tested with known three transformers of rating 5 kVA or more. The effects of stressing polarization voltage level, polarizing wave shapes and various terminal configurations provide characteristic aging relaxation information. By using different analyses, sensitive parameters of aging are identified and it is presented in this thesis.
Resumo:
IEC 61850 Process Bus technology has the potential to improve cost, performance and reliability of substation design. Substantial costs associated with copper wiring (designing, documentation, construction, commissioning and troubleshooting) can be reduced with the application of digital Process Bus technology, especially those based upon international standards. An IEC 61850-9-2 based sampled value Process Bus is an enabling technology for the application of Non-Conventional Instrument Transformers (NCIT). Retaining the output of the NCIT in its native digital form, rather than conversion to an analogue output, allows for improved transient performance, dynamic range, safety, reliability and reduced cost. In this paper we report on a pilot installation using NCITs communicating across a switched Ethernet network using the UCAIug Implementation Guideline for IEC 61850-9-2 (9-2 Light Edition or 9-2LE). This system was commissioned in a 275 kV Line Reactor bay at Powerlink Queensland’s Braemar substation in 2009, with sampled value protection IEDs 'shadowing' the existing protection system. The results of commissioning tests and twelve months of service experience using a Fibre Optic Current Transformer (FOCT) from Smart Digital Optics (SDO) are presented, including the response of the system to fault conditions. A number of remaining issues to be resolved to enable wide-scale deployment of NCITs and IEC 61850-9-2 Process Bus technology are also discussed.
Resumo:
There have only been minor improvements in rigid lens material developments since silicone acrylates and fluoro-silicone acrylates were introduced over a quarter of a century ago. Although there have been enhancements in mechanical lathing technology in the rigid lens field - primarily as a result of developments in computer-controlled systems - rigid lenses are still manufactured using labour-intensive lathing processes, which is why the lens unit cost remains much higher than for disposable soft lenses.
Resumo:
Available industrial energy meters offer high accuracy and reliability, but are typically expensive and low-bandwidth, making them poorly suited to multi-sensor data acquisition schemes and power quality analysis. An alternative measurement system is proposed in this paper that is highly modular, extensible and compact. To minimise cost, the device makes use of planar coreless PCB transformers to provide galvanic isolation for both power and data. Samples from multiple acquisition devices may be concentrated by a central processor before integration with existing host control systems. This paper focusses on the practical design and implementation of planar coreless PCB transformers to facilitate the module's isolated power, clock and data signal transfer. Calculations necessary to design coreless PCB transformers, and circuits designed for the transformer's practical application in the measurement module are presented. The designed transformer and each application circuit have been experimentally verified, with test data and conclusions made applicable to coreless PCB transformers in general.
Resumo:
The Dissolved Gas Analysis (DGA) a non destructive test procedure, has been in vogue for a long time now, for assessing the status of power and related transformers in service. An early indication of likely internal faults that may exist in Transformers has been seen to be revealed, to a reasonable degree of accuracy by the DGA. The data acquisition and subsequent analysis needs an expert in the concerned area to accurately assess the condition of the equipment. Since the presence of the expert is not always guaranteed, it is incumbent on the part of the power utilities to requisition a well planned and reliable artificial expert system to replace, at least in part, an expert. This paper presents the application of Ordered Ant Mner (OAM) classifier for the prediction of involved fault. Secondly, the paper also attempts to estimate the remaining life of the power transformer as an extension to the elapsed life estimation method suggested in the literature.
Resumo:
Inadvertent failure of power transformers has serious consequences on the power system reliability, economics and the revenue accrual. Insulation is the weakest link in the power transformer prompting periodic inspection of the status of insulation at different points in time. A close Monitoring of the electrical, chemical and such other properties on insulation as are sensitive to the amount of time-dependent degradation becomes mandatory to judge the status of the equipment. Data-driven Diagnostic Testing and Condition Monitoring (DTCM) specific to power transformer is the aspect in focus. Authors develop a Monte Carlo approach for augmenting the rather scanty experimental data normally acquired using Proto-types of power transformers. Also described is a validation procedure for estimating the accuracy of the Model so developed.