934 resultados para objective measures
Resumo:
Purpose: Concerns about self-reports have led to calls for objective measures of blood alcohol concentration (BAC). The present study compared objective measures with self-reports. Methods: BAC from breath or blood samples were obtained from 272 randomly sampled injured patients who were admitted to a Swiss emergency department (ED). Self-reports were compared a) between those providing and refusing a BAC test, and b) to estimated peak BAC (EPBAC) values based on BACs using the Widmark formula. Results: Those providing BACs were significantly (P < 0.05) younger, more often male, and less often reported alcohol consumption before injury, but consumed higher quantities when drinking. Eighty-eight percent of those with BAC measures gave consistent reports (positive or negative). Significantly more patients reported consumption with negative BAC measures (N = 29) than vice versa (N = 3). Duration of consumption and times between injury and BAC measurement predicted EPBAC better than did the objective BAC measure. Conclusions: There is little evidence that patients who provide objective BAC measures deliberately conceal consumption. ED studies must rely on self-reports, eg, take the time period between injury and ED admission into account. Clearly, objective measures are of clinical relevance, eg, to provide optimal treatment in the ED. However, they may be less relevant to establishing effects in an epidemiologic sense, such as estimating risk relationships. In this respect, efforts to increase the validity and reliability of self-reports should be preferred over the collection of additional objective measures.
Resumo:
This study examined hearing impaired listeners’ subjective perceptions of listening environments through a listening questionnaire and compared these results to objective measures mimicked by the questionnaire in the datalogging device SAM (Sound Activity Meter). Results indicate audiologists should not rely on patient reports of “typical” listening environments for hearing aid selection as significant discrepancies were present between several of the subjective and objective measures.
Resumo:
Inconsistencies exist between traditional objective measures such as speech recognition and localization, and subjective reports of bimodal benefit. The purpose of this study was to expand the set of objective measures of bimodal benefit to include non-traditional listening tests, and to examine possible correlations between objective measures of auditory perception and subjective satisfaction reports.
Resumo:
Background: The aim of this study was to evaluate stimulant medication response following a single dose of methylphenidate (MPH) in children and young people with hyperkinetic disorder using infrared motion analysis combined with a continuous performance task (QbTest system) as objective measures. The hypothesis was put forward that a moderate testdose of stimulant medication could determine a robust treatment response, partial response and non-response in relation to activity, attention and impulse control measures. Methods: The study included 44 children and young people between the ages of 7-18 years with a diagnosis of hyperkinetic disorder (F90 & F90.1). A single dose-protocol incorporated the time course effects of both immediate release MPH and extended release MPH (Concerta XL, Equasym XL) to determine comparable peak efficacy periods post intake. Results: A robust treatment response with objective measures reverting to the population mean was found in 37 participants (84%). Three participants (7%) demonstrated a partial response to MPH and four participants (9%) were determined as non-responders due to deteriorating activity measures together with no improvements in attention and impulse control measures. Conclusion: Objective measures provide early into prescribing the opportunity to measure treatment response and monitor adverse reactions to stimulant medication. Most treatment responders demonstrated an effective response to MPH on a moderate testdose facilitating a swift and more optimal titration process.
Resumo:
Objective: To investigate whether advanced visualizations of spirography-based objective measures are useful in differentiating drug-related motor dysfunctions between Off and dyskinesia in Parkinson’s disease (PD). Background: During the course of a 3 year longitudinal clinical study, in total 65 patients (43 males and 22 females with mean age of 65) with advanced PD and 10 healthy elderly (HE) subjects (5 males and 5 females with mean age of 61) were assessed. Both patients and HE subjects performed repeated and time-stamped assessments of their objective health indicators using a test battery implemented on a telemetry touch screen handheld computer, in their home environment settings. Among other tasks, the subjects were asked to trace a pre-drawn Archimedes spiral using the dominant hand and repeat the test three times per test occasion. Methods: A web-based framework was developed to enable a visual exploration of relevant spirography-based kinematic features by clinicians so they can in turn evaluate the motor states of the patients i.e. Off and dyskinesia. The system uses different visualization techniques such as time series plots, animation, and interaction and organizes them into different views to aid clinicians in measuring spatial and time-dependent irregularities that could be associated with the motor states. Along with the animation view, the system displays two time series plots for representing drawing speed (blue line) and displacement from ideal trajectory (orange line). The views are coordinated and linked i.e. user interactions in one of the views will be reflected in other views. For instance, when the user points in one of the pixels in the spiral view, the circle size of the underlying pixel increases and a vertical line appears in the time series views to depict the corresponding position. In addition, in order to enable clinicians to observe erratic movements more clearly and thus improve the detection of irregularities, the system displays a color-map which gives an idea of the longevity of the spirography task. Figure 2 shows single randomly selected spirals drawn by a: A) patient who experienced dyskinesias, B) HE subject, and C) patient in Off state. Results: According to a domain expert (DN), the spirals drawn in the Off and dyskinesia motor states are characterized by different spatial and time features. For instance, the spiral shown in Fig. 2A was drawn by a patient who showed symptoms of dyskinesia; the drawing speed was relatively high (cf. blue-colored time series plot and the short timestamp scale in the x axis) and the spatial displacement was high (cf. orange-colored time series plot) associated with smooth deviations as a result of uncontrollable movements. The patient also exhibited low amount of hesitation which could be reflected both in the animation of the spiral as well as time series plots. In contrast, the patient who was in the Off state exhibited different kinematic features, as shown in Fig. 2C. In the case of spirals drawn by a HE subject, there was a great precision during the drawing process as well as unchanging levels of time-dependent features over the test trial, as seen in Fig. 2B. Conclusions: Visualizing spirography-based objective measures enables identification of trends and patterns of drug-related motor dysfunctions at the patient’s individual level. Dynamic access of visualized motor tests may be useful during the evaluation of drug-related complications such as under- and over-medications, providing decision support to clinicians during evaluation of treatment effects as well as improve the quality of life of patients and their caregivers. In future, we plan to evaluate the proposed approach by assessing within- and between-clinician variability in ratings in order to determine its actual usefulness and then use these ratings as target outcomes in supervised machine learning, similarly as it was previously done in the study performed by Memedi et al. (2013).
Resumo:
The post-processing of association rules is a difficult task, since a large number of patterns can be obtained. Many approaches have been developed to overcome this problem, as objective measures and clustering, which are respectively used to: (i) highlight the potentially interesting knowledge in domain; (ii) structure the domain, organizing the rules in groups that contain, somehow, similar knowledge. However, objective measures don't reduce nor organize the collection of rules, making the understanding of the domain difficult. On the other hand, clustering doesn't reduce the exploration space nor direct the user to find interesting knowledge, making the search for relevant knowledge not so easy. This work proposes the PAR-COM (Post-processing Association Rules with Clustering and Objective Measures) methodology that, combining clustering and objective measures, reduces the association rule exploration space directing the user to what is potentially interesting. Thereby, PAR-COM minimizes the user's effort during the post-processing process.
Resumo:
Critically ill and injured patients require pain relief and sedation to reduce the body's stress response and to facilitate painful diagnostic and therapeutic procedures. Presently, the level of sedation and analgesia is guided by the use of clinical scores which can be unreliable. There is therefore, a need for an objective measure of sedation and analgesia. The Bispectral Index (BIS) and Patient State Index (PSI) were recently introduced into clinical practice as objective measures of the depth of analgesia and sedation. ^ Aim. To compare the different measures of sedation and analgesia (BIS and PSI) to the standard and commonly used modified Ramsay Score (MRS) and determine if the monitors can be used interchangeably. ^ Methods. MRS, BIS and PSI values were obtained in 50 postoperative cardiac surgery patients requiring analgesia and sedation from June to December 2004. The MRS, BIS and PSI values were assessed hourly for up to 6-h by a single observer. ^ The relationship between BIS and PSI values were explored using scatter plots and correlation between MRS, BIS and PSI was determined using Spearman's correlation coefficient. Intra-class correlation (ICC) was used to determine the inter-rater reliability of MRS, BIS and PSI. Kappa statistics was used to further evaluate the agreement between BIS and PSI at light, moderate and deep levels of sedation. ^ Results. There was a positive correlation between BIS and PSI values (Rho = 0.731, p<0.001). Intra-class correlation between BIS and PSI was 0.58, MRS and BIS 0.43 and MRS and PSI 0.27. Using Kappa statistics, agreement between MRS and BIS was 0.35 (95% CI: 0.27–0.43) and for MRS and PSI was 0.21 (95% CI: 0.15–0.28). The kappa statistic for BIS and PSI was 0.45 (95% CI: 0.37–0.52). Receiver operating characteristics (ROC) curves constructed to detect undersedation indicated an area under the curve (AUC) of 0.91 (95% CI = 0.87 to 0.94) for the BIS and 0.84 (95% CI = 0.79 to 0.88) for the PSI. For detection of oversedation, AUC for the BIS was 0.89 (95% CI = 0.84 to 0.92) and 0.80 (95% CI = 0.75 to 0.85) for the PSI. ^ Conclusions. There is a statistically significant positive correlation between the BIS and PSI but poor correlation and poor test agreement between the MRS and BIS as well as MRS and PSI. Both the BIS and PSI demonstrated a high level of prediction for undersedation and oversedation; however, the BIS and PSI can not be considered interchangeable monitors of sedation. ^
Resumo:
In industrialised countries age-related macular disease (ARMD) is the leading cause of visual loss in older people. Because oxidative stress is purported to be associated with an increased risk of disease development the role of antioxidant supplementation is of interest. Lutein is a carotenoid antioxidant that accumulates within the retina and is thought to filter blue light. Increased levels of lutein have been associated with reduced risk of developing ARMD and improvements in visual and retinal function in eyes with ARMD. The aim of this randomised controlled trial (RCT) was to investigate the effect of a lutein-based nutritional supplement on subjective and objective measures of visual function in healthy eyes and in eyes with age-related maculopathy (ARM) – an early form of ARMD. Supplement withdrawal effects were also investigated. A sample size of 66 healthy older (HO), healthy younger (HY), and ARM eyes were randomly allocated to receive a lutein-based supplement or no treatment for 40 weeks. The supplemented group then stopped supplementation to look at the effects of withdrawal over a further 20 weeks. The primary outcome measure was multifocal electroretinogram (mfERG) N1P1 amplitude. Secondary outcome measures were mfERG N1, P1 and N2 latency, contrast sensitivity (CS), Visual acuity (VA) and macular pigment optical density (MPOD). Sample sizes were sufficient for the RCT to have an 80% power to detect a significant clinical effect at the 5% significance level for all outcome measures when the healthy eye groups were combined, and CS, VA and mfERG in the ARM group. This RCT demonstrates significant improvements in MPOD in HY and HO supplemented eyes. When HY and HO supplemented groups were combined, MPOD improvements were maintained, and mfERG ring 2 P1 latency became shorter. On withdrawal of the supplement mfERG ring 1 N1P1 amplitude reduced in HO eyes. When HO and HY groups were combined, mfERG ring 1 and ring 2 N1P1 amplitudes were reduced. In ARM eyes, ring 3 N2 latency and ring 4 P1 latency became longer. These statistically significant changes may not be clinically significant. The finding that a lutein-based supplement increases MPOD in healthy eyes, but does not increase mfERG amplitudes contrasts with the CARMIS study and contributes to the debate on the use of nutritional supplementation in ARM.
Resumo:
An enormous burst of interest in the public health burden from chronic disease in Africa has emerged as a consequence of efforts to estimate global population health. Detailed estimates are now published for Africa as a whole and each country on the continent. These data have formed the basis for warnings about sharp increases in cardiovascular disease (CVD) in the coming decades. In this essay we briefly examine the trajectory of social development on the continent and its consequences for the epidemiology of CVD and potential control strategies. Since full vital registration has only been implemented in segments of South Africa and the island nations of Seychelles and Mauritius - formally part of WHO-AFRO - mortality data are extremely limited. Numerous sample surveys have been conducted but they often lack standardization or objective measures of health status. Trend data are even less informative. However, using the best quality data available, age-standardized trends in CVD are downward, and in the case of stroke, sharply so. While acknowledging that the extremely limited available data cannot be used as the basis for inference to the continent, we raise the concern that general estimates based on imputation to fill in the missing mortality tables may be even more misleading. No immediate remedies to this problem can be identified, however bilateral collaborative efforts to strength local educational institutions and governmental agencies rank as the highest priority for near term development.
Resumo:
This exploratory study intends to characterize the neuropsychological profile in persons with post-traumatic stress disorder (PTSD) and mild traumatic brain injury (mTBI) using objective measures of cognitive performance. A neuropsychological battery of tests for attention, memory and executive functions was administered to four groups: PTSD (n = 25), mTBI (n = 19), subjects with two formal diagnoses: Post-traumatic Stress Disorder and Mild Traumatic Brain Injury (mTBI/PTSD) (n = 6) and controls (n = 25). Confounding variables, such as medical, developmental or neurological antecedents, were controlled and measures of co-morbid conditions, such as depression and anxiety, were considered. The PTSD and mTBI/PTSD groups reported more anxiety and depressive symptoms. They also presented more cognitive deficits than the mTBI group. Since the two PTSD groups differ in severity of PTSD symptoms but not in severity of depression and anxiety symptoms, the PTSD condition could not be considered as the unique factor affecting the results. The findings underline the importance of controlling for confounding medical and psychological co-morbidities in the evaluation and treatment of PTSD populations, especially when a concomitant mTBI is also suspected.
Resumo:
Empirical Mode Decomposition (EMD) is a data driven technique for extraction of oscillatory components from data. Although it has been introduced over 15 years ago, its mathematical foundations are still missing which also implies lack of objective metrics for decomposed set evaluation. Most common technique for assessing results of EMD is their visual inspection, which is very subjective. This article provides objective measures for assessing EMD results based on the original definition of oscillatory components.
Resumo:
Background Along the internal carotid artery (ICA), atherosclerotic plaques are often located in its cavernous sinus (parasellar) segments (pICA). Studies indicate that the incidence of pre-atherosclerotic lesions is linked with the complexity of the pICA; however, the pICA shape was never objectively characterized. Our study aims at providing objective mathematical characterizations of the pICA shape. Methods and results Three-dimensional (3D) computer models, reconstructed from contrast enhanced computed tomography (CT) data of 30 randomly selected patients (60 pICAs) were analyzed with modern visualization software and new mathematical algorithms. As objective measures for the pICA shape complexity, we provide calculations of curvature energy, torsion energy, and total complexity of 3D skeletons of the pICA lumen. We further measured the posterior knee of the so-called ""carotid siphon"" with a virtual goniometer and performed correlations between the objective mathematical calculations and the subjective angle measurements. Conclusions Firstly, our study provides mathematical characterizations of the pICA shape, which can serve as objective reference data for analyzing connections between pICA shape complexity and vascular diseases. Secondly, we provide an objective method for creating Such data. Thirdly, we evaluate the usefulness of subjective goniometric measurements of the angle of the posterior knee of the carotid siphon.
Resumo:
A challenge for the clinical management of advanced Parkinson’s disease (PD) patients is the emergence of fluctuations in motor performance, which represents a significant source of disability during activities of daily living of the patients. There is a lack of objective measurement of treatment effects for in-clinic and at-home use that can provide an overview of the treatment response. The objective of this paper was to develop a method for objective quantification of advanced PD motor symptoms related to off episodes and peak dose dyskinesia, using spiral data gathered by a touch screen telemetry device. More specifically, the aim was to objectively characterize motor symptoms (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Digitized upper limb movement data of 65 advanced PD patients and 10 healthy (HE) subjects were recorded as they performed spiral drawing tasks on a touch screen device in their home environment settings. Several spatiotemporal features were extracted from the time series and used as inputs to machine learning methods. The methods were validated against ratings on animated spirals scored by four movement disorder specialists who visually assessed a set of kinematic features and the motor symptom. The ability of the method to discriminate between PD patients and HE subjects and the test-retest reliability of the computed scores were also evaluated. Computed scores correlated well with mean visual ratings of individual kinematic features. The best performing classifier (Multilayer Perceptron) classified the motor symptom (bradykinesia or dyskinesia) with an accuracy of 84% and area under the receiver operating characteristics curve of 0.86 in relation to visual classifications of the raters. In addition, the method provided high discriminating power when distinguishing between PD patients and HE subjects as well as had good test-retest reliability. This study demonstrated the potential of using digital spiral analysis for objective quantification of PD-specific and/or treatment-induced motor symptoms.
Resumo:
OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.