961 resultados para nuclear recoils


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso, Italy are presented. Data from measurements with an external AmB(241)e neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy-dependent charge-yield Q(y) and relative scintillation efficiency L-eff. A very good level of absolute spectral matching is achieved in both observable signal channels-scintillation S1 and ionization S2-along with agreement in the two-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les observations astronomiques et cosmologiques suggèrent fortement la présence d’une matière exotique, non-relativiste et non-baryonique qui représenterait 26% du contenu de masse-énergie de l’Univers actuel. Cette matière dite sombre et froide serait compo- sée de particules neutres, massives et interagissant faiblement avec la matière ordinaire (WIMP : Weakly Interactive Massive Particles). Le projet PICASSO (Projet d’Identification des CAndidats Supersymétriques de la matière SOmbre) est une des expériences installées dans le site souterrain de SNOLAB à Sudbury en Ontario, qui tente de détecter directement un des candidats de la matière sombre, proposé dans le cadre des extensions supersymétriques du modèle standard : le neutralino. Pour cela, PICASSO utilise des détecteurs à gouttelettes surchauffées de C4F10, basés sur le principe de la chambre à bulles. Les transitions de phase dans les liquides surchauffés peuvent être déclenchées par le recul du 19 F, causé par une collision élastique avec les neutralinos. La nucléation de la gouttelette génère une onde sonore enregistrée par des senseurs piézo-électriques. Cette thèse présentera les récents progrès de l’expérience PICASSO qui ont conduit à une augmentation substantielle de sa sensibilité dans la recherche du neutralino. En effet, de nouvelles procédures de fabrication et de purification ont permis de réduire à un facteur de 10, la contamination majeure des détecteurs, causée par les émetteurs alpha. L’étude de cette contamination dans les détecteurs a permis de localiser la source de ces émetteurs. Les efforts effectués dans le cadre de l’analyse des données, ont permis d’améliorer l’effet de discrimination entre des évènements engendrés par les particules alpha et par les reculs nucléaires. De nouveaux outils d’analyse ont également été implémentés dans le but de discriminer les évènements générés par des particules de ceux générés par des bruits de fond électroniques ou acoustiques. De plus, un mécanisme important de suppression de bruit de fond indésirable à haute température, a permis à l’expérience PICASSO d’être maintenant sensible aux WIMPs de faibles masses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter weakly interacting massive particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We study the sensitivity of large-scale xenon detectors to low-energy solar neutrinos, to coherent neutrino-nucleus scattering and to neutrinoless double beta decay. As a concrete example, we consider the xenon part of the proposed DARWIN (Dark Matter WIMP Search with Noble Liquids) experiment. We perform detailed Monte Carlo simulations of the expected backgrounds, considering realistic energy resolutions and thresholds in the detector. In a low-energy window of 2–30 keV, where the sensitivity to solar pp and 7Be-neutrinos is highest, an integrated pp-neutrino rate of 5900 events can be reached in a fiducial mass of 14 tons of natural xenon, after 5 years of data. The pp-neutrino flux could thus be measured with a statistical uncertainty around 1%, reaching the precision of solar model predictions. These low-energy solar neutrinos will be the limiting background to the dark matter search channel for WIMP-nucleon cross sections below ~2X 10-48 cm2 and WIMP masses around 50 GeV c 2, for an assumed 99.5% rejection of electronic recoils due to elastic neutrino-electron scatters. Nuclear recoils from coherent scattering of solar neutrinos will limit the sensitivity to WIMP masses below ~6 GeV c-2 to cross sections above ~4X10-45cm2. DARWIN could reach a competitive half-life sensitivity of 5.6X1026 y to the neutrinoless double beta decay of 136Xe after 5 years of data, using 6 tons of natural xenon in the central detector region.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic acquired resistance (SAR) is a broad-spectrum resistance in plants that involves the upregulation of a battery of pathogenesis-related (PR) genes. NPR1 is a key regulator in the signal transduction pathway that leads to SAR. Mutations in NPR1 result in a failure to induce PR genes in systemic tissues and a heightened susceptibility to pathogen infection, whereas overexpression of the NPR1 protein leads to increased induction of the PR genes and enhanced disease resistance. We analyzed the subcellular localization of NPR1 to gain insight into the mechanism by which this protein regulates SAR. An NPR1–green fluorescent protein fusion protein, which functions the same as the endogenous NPR1 protein, was shown to accumulate in the nucleus in response to activators of SAR. To control the nuclear transport of NPR1, we made a fusion of NPR1 with the glucocorticoid receptor hormone binding domain. Using this steroid-inducible system, we clearly demonstrate that nuclear localization of NPR1 is essential for its activity in inducing PR genes.