995 resultados para nuclear power


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Great Tohoku-Kanto earthquake and resulting tsunami has brought considerable attention to the issue of the construction of new power plants. We argue in this paper, nuclear power is not a sustainable solution to energy problems. First, we explore the stock of uranium-235 and the different schemes developed by the nuclear power industry to exploit this resource. Second, we show that these methods, fast breeder and MOX fuel reactors, are not feasible. Third, we show that the argument that nuclear energy can be used to reduce CO2 emissions is false: the emissions from the increased water evaporation from nuclear power generation must be accounted for. In the case of Japan, water from nuclear power plants is drained into the surrounding sea, raising the water temperature which has an adverse affect on the immediate ecosystem, as well as increasing CO2 emissions from increased water evaporation from the sea. Next, a short exercise is used to show that nuclear power is not even needed to meet consumer demand in Japan. Such an exercise should be performed for any country considering the construction of additional nuclear power plants. Lastly, the paper is concluded with a discussion of the implications of our findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When decommissioning a nuclear facility it is important to be able to estimate activity levels of potentially radioactive samples and compare with clearance values defined by regulatory authorities. This paper presents a method of calibrating a clearance box monitor based on practical experimental measurements and Monte Carlo simulations. Adjusting the simulation for experimental data obtained using a simple point source permits the computation of absolute calibration factors for more complex geometries with an accuracy of a bit more than 20%. The uncertainty of the calibration factor can be improved to about 10% when the simulation is used relatively, in direct comparison with a measurement performed in the same geometry but with another nuclide. The simulation can also be used to validate the experimental calibration procedure when the sample is supposed to be homogeneous but the calibration factor is derived from a plate phantom. For more realistic geometries, like a small gravel dumpster, Monte Carlo simulation shows that the calibration factor obtained with a larger homogeneous phantom is correct within about 20%, if sample density is taken as the influencing parameter. Finally, simulation can be used to estimate the effect of a contamination hotspot. The research supporting this paper shows that activity could be largely underestimated in the event of a centrally-located hotspot and overestimated for a peripherally-located hotspot if the sample is assumed to be homogeneously contaminated. This demonstrates the usefulness of being able to complement experimental methods with Monte Carlo simulations in order to estimate calibration factors that cannot be directly measured because of a lack of available material or specific geometries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Previous studies on childhood cancer and nuclear power plants (NPPs) produced conflicting results. We used a cohort approach to examine whether residence near NPPs was associated with leukaemia or any childhood cancer in Switzerland. METHODS: We computed person-years at risk for children aged 0-15 years born in Switzerland from 1985 to 2009, based on the Swiss censuses 1990 and 2000 and identified cancer cases from the Swiss Childhood Cancer Registry. We geo-coded place of residence at birth and calculated incidence rate ratios (IRRs) with 95% confidence intervals (CIs) comparing the risk of cancer in children born <5 km, 5-10 km and 10-15 km from the nearest NPP with children born >15 km away, using Poisson regression models. RESULTS: We included 2925 children diagnosed with cancer during 21 117 524 person-years of follow-up; 953 (32.6%) had leukaemia. Eight and 12 children diagnosed with leukaemia at ages 0-4 and 0-15 years, and 18 and 31 children diagnosed with any cancer were born <5 km from a NPP. Compared with children born >15 km away, the IRRs (95% CI) for leukaemia in 0-4 and 0-15 year olds were 1.20 (0.60-2.41) and 1.05 (0.60-1.86), respectively. For any cancer, corresponding IRRs were 0.97 (0.61-1.54) and 0.89 (0.63-1.27). There was no evidence of a dose-response relationship with distance (P > 0.30). Results were similar for residence at diagnosis and at birth, and when adjusted for potential confounders. Results from sensitivity analyses were consistent with main results. CONCLUSIONS: This nationwide cohort study found little evidence of an association between residence near NPPs and the risk of leukaemia or any childhood cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ydinvoimalaitokset on suunniteltu ja rakennettu niin, että niillä on kyky selviytyä erilaisista käyttöhäiriöistä ja onnettomuuksista ilman laitoksen vahingoittumista sekä väestön ja ympäristön vaarantumista. On erittäin epätodennäköistä, että ydinvoimalaitosonnettomuus etenee reaktorisydämen vaurioitumiseen asti, minkä seurauksena sydänmateriaalien hapettuminen voi tuottaa vetyä. Jäädytyspiirin rikkoutumisen myötä vety saattaa kulkeutua ydinvoimalaitoksen suojarakennukseen, jossa se voi muodostaa palavan seoksen ilman hapen kanssa ja palaa tai jopa räjähtää. Vetypalosta aiheutuvat lämpötila- ja painekuormitukset vaarantavat suojarakennuksen eheyden ja suojarakennuksen sisällä olevien turvajärjestelmien toimivuuden, joten tehokas ja luotettava vedynhallintajärjestelmä on tarpeellinen. Passiivisia autokatalyyttisiä vetyrekombinaattoreita käytetäänyhä useammissa Euroopan ydinvoimaitoksissa vedynhallintaan. Nämä rekombinaattorit poistavat vetyä katalyyttisellä reaktiolla vedyn reagoidessa katalyytin pinnalla hapen kanssa muodostaen vesihöyryä. Rekombinaattorit ovat täysin passiivisiaeivätkä tarvitse ulkoista energiaa tai operaattoritoimintaa käynnistyäkseen taitoimiakseen. Rekombinaattoreiden käyttäytymisen tutkimisellatähdätään niiden toimivuuden selvittämiseen kaikissa mahdollisissa onnettomuustilanteissa, niiden suunnittelun optimoimiseen sekä niiden optimaalisen lukumäärän ja sijainnin määrittämiseen suojarakennuksessa. Suojarakennuksen mallintamiseen käytetään joko keskiarvoistavia ohjelmia (Lumped parameter (LP) code), moniulotteisia virtausmalliohjelmia (Computational Fluid Dynamics, CFD) tai näiden yhdistelmiä. Rekombinaattoreiden mallintaminen on toteutettu näissä ohjelmissa joko kokeellisella, teoreettisella tai yleisellä (eng. Global Approach) mallilla. Tämä diplomityö sisältää tulokset TONUS OD-ohjelman sisältämän Siemens FR90/1-150 rekombinaattorin mallin vedynkulutuksen tarkistuslaskuista ja TONUS OD-ohjelmalla suoritettujen laskujen tulokset Siemens rekombinaattoreiden vuorovaikutuksista. TONUS on CEA:n (Commissariat à 1'En¬ergie Atomique) kehittämä LP (OD) ja CFD -vetyanalyysiohjelma, jota käytetään vedyn jakautumisen, palamisenja detonaation mallintamiseen. TONUS:sta käytetään myös vedynpoiston mallintamiseen passiivisilla autokatalyyttisillä rekombinaattoreilla. Vedynkulutukseen vaikuttavat tekijät eroteltiin ja tutkittiin yksi kerrallaan. Rekombinaattoreiden vuorovaikutuksia tutkittaessa samaan tilavuuteen sijoitettiin eri kokoisia ja eri lukumäärä rekombinaattoreita. Siemens rekombinaattorimalli TONUS OD-ohjelmassa laskee vedynkulutuksen kuten oletettiin ja tulokset vahvistavat TONUS OD-ohjelman fysikaalisen laskennan luotettavuuden. Mahdollisia paikallisia jakautumia tutkitussa tilavuudessa ei voitu havaita LP-ohjelmalla, koska se käyttäälaskennassa suureiden tilavuuskeskiarvoja. Paikallisten jakautumien tutkintaan tarvitaan CFD -laskentaohjelma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis includes several thermal hydraulic analyses related to the Loviisa WER 440 nuclear power plant units. The work consists of experimental studies, analysis of the experiments, analysis of some plant transits and development of a calculational model for calculation of boric acid concentrations in the reactor. In the first part of the thesis, in the case of won of boric acid solution behaviour during long term cooling period of LOCAs, experiments were performed in scaled down test facilities. The experimental data together with the results of RELAPS/MOD3 simulations were used to develop a model for calculations of boric acid concentrations in the reactor during LOCAs. The results of calculations showed that margins to critical concentrations that would lead to boric acid crystallization were large, both in the reactor core and in the lower plenum. This was mainly caused by the fact that water in the primary cooling circuit includes borax (Na)BsO,.IOHZO), which enters the reactor when ECC water is taken from the sump and greatly increases boric acid solubility in water. In the second part, in the case of simulation of horizontal steam generators, experiments were performed with PACTEL integral test loop to simulate loss of feedwater transients. The PACTEL experiments, as well as earlier REWET III natural circulation tests, were analyzed with RELAPS/MOD3 Version Sm5 code. The analysis showed that the code was capable of simulating the main events during the experiments. However, in the case of loss of secondary side feedwater the code was not completely capable to simulate steam superheating in the secondary side of the steam generators. The third part of the work consists of simulations of Loviisa VVER reactor pump trip transients with RELAPSlMODI Eur, RELAPS/MOD3 and CATHARE codes. All three codes were capable to simulate the two selected pump trip transients and no significant differences were found between the results of different codes. Comparison of the calculated results with the data measured in the Loviisa plant also showed good agreement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityön tarkoituksena oli tutkia vaatimusten hallintaa suunnittelu- ja konsultointiyrityksen kannalta Suomen ydinvoimaprojekteissa keskittyen ydinturvallisuus- ja laatuvaatimuksiin. Ydinvoimaprojekteissa toimiminen on edellyttänyt menettelyohjeiden ja laatujärjestelmän uudelleen organisointia yrityksessä ja esiin on noussut haasteita liittyen muun muassa vaatimusten tunnistamiseen ja todentamiseen erityyppisissä ja erilaajuisissa projekteissa. Työ toteutettiin perehtymällä ydinvoimaan liittyvään lainsäädäntöön Suomessa, ohjeisiin ja standardeihin sekä haastattelemalla yrityksen omia asiantuntijoita. Viimeaikaisista sekä meneillään olevista projekteista kerättiin kokemuksia sekä arvioitiin ydinvoima projekteja varten laaditun projektin toteutusohjeen toimivuutta ja käytettävyyttä esimerkkiprojektin avulla. Suurimmiksi haasteiksi tunnistettiin lainsäädännöllisten vaatimusten, kuten ydinvoima- laitosohjeiden (YVL) muuttuminen ja tulkinnanvaraisuus sekä asiakkaiden perehtymät- tömyys Suomen lainsäädäntöön ja vaatimustasoon liittyen ydinturvallisuuteen. Työn tuloksena tunnistettiin hyviä vaatimusten hallintaan liittyviä projektinhallintaa ja ydin- turvallisuutta edistäviä asioita, kuten vaatimusten täsmentäminen jo sopimustasolla sekä niiden täyttymisen seuranta projektin aikana. Erillisen vaatimustietokannan luomista ydinvoimaprojekteja varten tutkittiin, mutta siitä luovuttiin teknisten vaatimusten osalta kannattamattomana, sillä standardien ja vaatimusten määrä kasvoi niin suureksi, että niiden hallitseminen vaatisi enemmän työtä kuin mitä projektien taso yleensä sallisi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently widely accepted consensus is that greenhouse gas emissions produced by the mankind have to be reduced in order to avoid further global warming. The European Union has set a variety of CO2 reduction and renewable generation targets for its member states. The current energy system in the Nordic countries is one of the most carbon free in the world, but the aim is to achieve a fully carbon neutral energy system. The objective of this thesis is to consider the role of nuclear power in the future energy system. Nuclear power is a low carbon energy technology because it produces virtually no air pollutants during operation. In this respect, nuclear power is suitable for a carbon free energy system. In this master's thesis, the basic characteristics of nuclear power are presented and compared to fossil fuelled and renewable generation. Nordic energy systems and different scenarios in 2050 are modelled. Using models and information about the basic characteristics of nuclear power, an opinion is formed about its role in the future energy system in Nordic countries. The model shows that it is possible to form a carbon free Nordic energy system. Nordic countries benefit from large hydropower capacity which helps to offset fluctuating nature of wind power. Biomass fuelled generation and nuclear power provide stable and predictable electricity throughout the year. Nuclear power offers better energy security and security of supply than fossil fuelled generation and it is competitive with other low carbon technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this master’s thesis is to gain an understanding of passive safety systems’ role in modern nuclear reactors projects and to research the failure modes of passive decay heat removal safety systems which use phenomenon of natural circulation. Another purpose is to identify the main physical principles and phenomena which are used to establish passive safety tools in nuclear power plants. The work describes passive decay heat removal systems used in AES-2006 project and focuses on the behavior of SPOT PG system. The descriptions of the main large-scale research facilities of the passive safety systems of the AES-2006 power plant are also included. The work contains the calculations of the SPOT PG system, which was modeled with thermal-hydraulic system code TRACE. The dimensions of the calculation model are set according to the dimensions of the real SPOT PG system. In these calculations three parameters are investigated as a function of decay heat power: the pressure of the system, the natural circulation mass flow rate around the closed loop, and the level of liquid in the downcomer. The purpose of the calculations is to test the ability of the SPOT PG system to remove the decay heat from the primary side of the nuclear reactor in case of failure of one, two, or three loops out of four. The calculations show that three loops of the SPOT PG system have adequate capacity to provide the necessary level of safety. In conclusion, the work supports the view that passive systems could be widely spread in modern nuclear projects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter brings a human security lens to bear on the energy-mix question in post-Fukushima Japan. In particular, two of the four elements of human security identified in the 1994 Human Development Report (HDR), prevention and people-centeredness, are mobilized. We trace developments in Japan’s post-Fukushima nuclear politics through the demise of DPJ rule to the advent of the LDP government, and evaluate the current nuclear energy strategy of the Abe administration. Using a human security framework, we consider the economic security dimension of the arguments for and against the use of nuclear power, and weigh the result of this consideration against a concern with the six other elements of human security identified in the 1994 HDR. We conclude that the risks and threats to human security engendered by the use of nuclear energy outweigh any benefits that could reasonably be argued to accrue from its use. The notion of prevention, so central to the concept of human security, performs a further ‘trumping’ function, in leading us to put a premium on the downside risk of the use of nuclear energy.