816 resultados para normative values


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Auditory event-related potentials (AERPs) are widely used in diverse fields of today’s neuroscience, concerning auditory processing, speech perception, language acquisition, neurodevelopment, attention and cognition in normal aging, gender, developmental, neurologic and psychiatric disorders. However, its transposition to clinical practice has remained minimal. Mainly due to scarce literature on normative data across age, wide spectrumof results, variety of auditory stimuli used and to different neuropsychological meanings of AERPs components between authors. One of the most prominent AERP components studied in last decades was N1, which reflects auditory detection and discrimination. Subsequently, N2 indicates attention allocation and phonological analysis. The simultaneous analysis of N1 and N2 elicited by feasible novelty experimental paradigms, such as auditory oddball, seems an objective method to assess central auditory processing. The aim of this systematic review was to bring forward normative values for auditory oddball N1 and N2 components across age. EBSCO, PubMed, Web of Knowledge and Google Scholarwere systematically searched for studies that elicited N1 and/or N2 by auditory oddball paradigm. A total of 2,764 papers were initially identified in the database, of which 19 resulted from hand search and additional references, between 1988 and 2013, last 25 years. A final total of 68 studiesmet the eligibility criteria with a total of 2,406 participants from control groups for N1 (age range 6.6–85 years; mean 34.42) and 1,507 for N2 (age range 9–85 years; mean 36.13). Polynomial regression analysis revealed thatN1latency decreases with aging at Fz and Cz,N1 amplitude at Cz decreases from childhood to adolescence and stabilizes after 30–40 years and at Fz the decrement finishes by 60 years and highly increases after this age. Regarding N2, latency did not covary with age but amplitude showed a significant decrement for both Cz and Fz. Results suggested reliable normative values for Cz and Fz electrode locations; however, changes in brain development and components topography over age should be considered in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 +/- 3.4, coronary sinus 34.2 +/- 4.1, sino-tubular junction 29.7 +/- 3.4 and mid ascending aorta 32.7 +/- 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 +/- 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 +/- 3.7, and between both coronary ostia 7.2 +/- 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 +/- 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 +/- 3.3, CV 13-43%. Mean aortic valve area was 582.0 +/- 131.9 mm(2). The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assessments of spinal nociceptive withdrawal reflexes can be used in human research both to evaluate the effect of analgesics and explore pain mechanisms related to sensitization. Before the reflex can be used as a clinical tool, normative values need to be determined in large scale studies. The aim of this study was to determine the reference values of spinal nociceptive reflexes and subjective pain thresholds (to single and repeated stimulation), and of the area of the reflex receptive fields (RRF) in 300 pain-free volunteers. The influences of gender, age, height, weight, body-mass index (BMI), body side of testing, depression, anxiety, catastrophizing and parameters of Short-Form 36 (SF-36) were analyzed by multiple regressions. The 95% confidence intervals were determined for all the tests as normative values. Age had a statistically and quantitatively significant impact on the subjective pain threshold to single stimuli. The reflex threshold to single stimulus was lower on the dominant compared to the non-dominant side. Depression had a negative impact on the subjective pain threshold to single stimuli. All the other analyses either did not reveal statistical significance or displayed quantitatively insignificant correlations. In conclusion, normative values of parameters related to the spinal nociceptive reflex were determined. This allows their clinical application for assessing central hyperexcitability in individual patients. The parameters investigated explore different aspects of sensitization processes that are largely independent of demographic characteristics, cognitive and affective factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: In the Swiss version of the Freiburg speech intelligibility test five test words from the original German recording which are rarely used in Switzerland have been exchanged. Furthermore, differences in the transfer functions between headphone and loudspeaker presentation are not taken into account during calibration. New settings for the levels of the individual test words in the recommended recording and small changes in calibration procedures led us to make a verification of the currently used normative values.PATIENTS AND METHODS: Speech intelligibility was measured in 20 subjects with normal hearing using monosyllabic words and numbers via headphones and loudspeakers.RESULTS: On average, 50% speech intelligibility was reached at levels which were 7.5 dB lower under free-field conditions than for headphone presentation. The average difference between numbers and monosyllabic words was found to be 9.6 dB, which is considerably lower than the 14 dB of the current normative curves.CONCLUSIONS: There is a good agreement between our measurements and the normative values for tests using monosyllabic words and headphones, but not for numbers or free-field measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The Melbourne Edge Test (MET) is a portable forced-choice edge detection contrast sensitivity (CS) test. The original externally illuminated paper test has been superseded by a backlit version. The aim of this study was to establish normative values for age and to assess change with visual impairment. Method: The MET was administered to 168 people with normal vision (18-93 years old) and 93 patients with visual impairment (39-97 years old). Distance visual acuity (VA) was measured with a log MAR chart. Results: In those eyes without disease, MET CS was stable until the age of 50 years (23.8 ± .7 dB) after which it decreased at a rate of ≈1.5 dB per decade. Compared with normative values, people with low vision were found to have significantly reduced CS, which could not be totally accounted for by reduced VA. Conclusions: The MET provides a quick and easy measure of CS, which highlights a reduction in visual function that may not be detectable using VA measurements. © 2004 The College of Optometrists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Our aim was to determine the normative reference values of cardiorespiratory fitness (CRF) and to establish the proportion of subjects with low CRF suggestive of future cardio-metabolic risk.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Isometric grip strength, evaluated with a handgrip dynamometer, is a marker of current nutritional status and cardiometabolic risk and future morbidity and mortality. We present reference values for handgrip strength in healthy young Colombian adults (aged 18 to 29 years). Methods: The sample comprised 5.647 (2.330 men and 3.317 women) apparently healthy young university students (mean age, 20.6±2.7 years) attending public and private institutions in the cities of Bogota and Cali (Colombia). Handgrip strength was measured two times with a TKK analogue dynamometer in both hands and the highest value used in the analysis. Sex- and age-specific normative values for handgrip strength were calculated using the LMS method and expressed as tabulated percentiles from 3 to 97 and as smoothed centile curves (P3, P10, P25, P50, P75, P90 and P97). Results: Mean values for right and left handgrip strength were 38.1±8.9 and 35.9±8.6 kg for men, and 25.1±8.7 and 23.3±8.2 kg for women, respectively. Handgrip strength increased with age in both sexes and was significantly higher in men in all age categories. The results were generally more homogeneous amongst men than women. Conclusions: Sex- and age-specific handgrip strength normative values among healthy young Colombian adults are defined. This information may be helpful in future studies of secular trends in handgrip strength and to identify clinically relevant cut points for poor nutritional and elevated cardiometabolic risk in a Latin American population. Evidence of decline in handgrip strength before the end of the third decade is of concern and warrants further investigation

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper discusses whether the use of tympanometry and current normative values are applicable in assessing middle ear status in children with cochlear implants.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Quantitative sensory tests are widely used in human research to evaluate the effect of analgesics and explore altered pain mechanisms, such as central sensitization. In order to apply these tests in clinical practice, knowledge of reference values is essential. The aim of this study was to determine the reference values of pain thresholds for mechanical and thermal stimuli, as well as withdrawal time for the cold pressor test in 300 pain-free subjects. Pain detection and pain tolerance thresholds to pressure, heat and cold were determined at three body sites: (1) lower back, (2) suprascapular region and (3) second toe (for pressure) or the lateral aspect of the leg (for heat and cold). The influences of gender, age, height, weight, body-mass index (BMI), body side of testing, depression, anxiety, catastrophizing and parameters of Short-Form 36 (SF-36) were analyzed by multiple regressions. Quantile regressions were performed to define the 5th, 10th and 25th percentiles as reference values for pain hypersensitivity and the 75th, 90th and 95th percentiles as reference values for pain hyposensitivity. Gender, age and/or the interaction of age with gender were the only variables that consistently affected the pain measures. Women were more pain sensitive than men. However, the influence of gender decreased with increasing age. In conclusion, normative values of parameters related to pressure, heat and cold pain stimuli were determined. Reference values have to be stratified by body region, gender and age. The determination of these reference values will now allow the clinical application of the tests for detecting abnormal pain reactions in individual patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To determine normal values for four commonly used clinical functional balance tests from community-dwelling women aged 20 to 80 and to identify any significant decline due to aging. DESIGN: A cross-sectional study was undertaken to provide normative values for four clinical balance tests across 6 decade cohorts. SETTING: The Betty Byrne-Henderson Center for Women and Aging, Royal Womens' Hospital, Brisbane, Australia. PARTICIPANTS: Four hundred fifty-six community-dwelling, independently ambulant women with no obvious neurological or musculoskeletal-related disability, aged 20 to 80, were randomly recruited from a large metropolitan region. MEASUREMENTS: The clinical balance measures/tests were the Timed Up and Go test, step test, Functional Reach test, and lateral reach test. Multivariate analysis was used to test the effect for age, height, and activity level. RESULTS: Normal data were produced for each test across each decade cohort. Gradual decline in balance performance was confirmed, with significant effect for age demonstrated. CONCLUSION: New normative data across the adult age decades are available for these clinical tests. Use of clinical balance tests could complement other balance tests and be used to screen women aged 40 to 60 whose performance is outside the normal values for age and to decrease later falls risk.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study presents tympanometric normative data for Australian children at school entry in view of the lack of age-specific population-based data for this group. Participants were 327 children (164 boys, 163 girls) aged between 5 and 6 years, who had no history of middle ear infection, and passed pure-tone screening at 20 dB HL. Normative values for static admittance (SA), ear canal volume (ECV), tympanometric peak pressure, tympanometric width (TW) and tympanometric gradient were established. Based on these normative data, the use of the ASHA (1997) guidelines for medical referral, in which ECV > 1.0 ml in the presence of a flat tympanogram, SA < 0.3 ml, or TW > 200 daPa may not provide the best criteria for Australian children aged between 5 and 6 years. If SA < 0.3 ml were used instead of SA < 0.16 ml, a greater proportion of Australian children would have failed tympanometry, thus increasing the false alarm rate.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We have attempted to establish normative values of components of the magnetic evoked field to flash and pattern reversal stimuli prior to clinical use of the MEG. Full visual field, binocular evoked magnetic fields were recorded from 100 subjects 16 to 86 years of age with a single channel dc Squid (BTI) second-order gradiometer at a point 5-6cm above the inion. The majority of subjects showed a large positive component (out going magnetic field) of mean latency 115 ms (SD range 2.5 -11.8 in different decades of life) to the pattern reversal stimulus. In many subjects, this P100M was preceeded and succeeded by negative deflections (in going field). About 6% of subjects showed an inverted response i.e. a PNP wave. Waveforms to flash were more variable in shape with several positive components; the most consistent having a mean latency of 110ms (SD range 6.4-23.2). Responses to both stimuli were consistent when measured on the same subject on six different occasions (SD range 4.8 to 7.3). The data suggest that norms can be established for evoked magnetic field components, in particular for the pattern reversal P100M, which could be used in the diagnosis of neuro-opthalmological disease.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El propósito del presente estudio era generar los valores normativos de salto largo para niños de 9-17.9 años, e investigar las diferencias de sexo y grupo de edad

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Maximization of bone accrual during the growing years is thought to be an important factor in minimizing fracture risk in old age. Mechanical loading through physical activity has been recommended as a modality for the conservation of bone mineral in adults; however, few studies have evaluated the impact of different loading regimes in growing children. The purpose of this study was to compare bone mineral density (BMD) in weight-bearing and non-weight-bearing limbs in 17 children with unilateral Legg Calve Perthes Disease (LCPD). Children with this condition have an altered weight-bearing pattern whereby there is increased mechanical loading on the noninvolved normal hip and reduced loading on the involved painful hip. Thus, these children provide a unique opportunity to study the impact of differential mechanical loading on BMD during the growing years while controlling for genetic disposition. BMD at four regions of the proximal femur (trochanter, intertrochanter, femoral neck, total of the regions) was measured using dual energy x-ray absorptiometry (DXA), and the values were compared between the involved and noninvolved sides of the children with LCPD. The BMD of both sides also were compared with normative values based on both chronological and skeletal age data. A significantly higher BMD was found on the noninvolved side over the involved side for all regions (P