962 resultados para nondecalcified sections


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: this study aimed to develop a nondecalcified bone sample processing technique enabling immunohistochemical labeling of proteins by kappa-beta nuclear factor (NF-kB) utilizing the Technovit 7200 VCR (R) in adult male Wistar rats. Study Method: A 1.8 mm diameter defect was performed 0.5mm from the femur proximal joint by means of a round bur. Experimental groups were divided according to fixing solution prior to histologic processing: Group 1- ethanol 70%; Group 2-10% buffered formalin; and Group 3- Glycerol diluted in 70% ethanol at a 70/30 ratio + 10% buffered formalin. The post-surgical periods ranged from 01 to 24 hours. Control groups included a nonsurgical procedure group (NSPG) and surgical procedures where bone exposure was performed (SPBE) without drilling. Prostate carcinoma was the positive control (PC) and samples subjected to incomplete immunohistochemistry protocol were the negative control (NC). Following euthanization, all samples were kept at 4 degrees C for 7 days, and were dehydrated in a series of alcohols at -20 degrees C. The polymer embedding procedure was performed at ethanol/polymer ratios of 70%-30%, 50%-50%, 30%-70%, 100%, and 100% for 72 hours at -20 degrees C. Polymerization followed the manufacturer`s recommendation. The samples were grounded and polished to 10-15 mu m thickness, and were deacrylated. The sections were rehydrated and were submitted to the primary polyclonal antibody anti-NF-kB on a 1:75 dilution for 12 hours at room temperature. Results: Microscopy showed that the Group 2 presented positive reaction to NF-kB, diffuse reactions for NSPG and SPBE, and no reaction for the NC group. Conclusion: The results obtained support the feasibility of the developed immunohistochemistry technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: To evaluate the haemostatic efficacy and the histologic tissue responses after the application of different haemostatic agents used in periradicular surgery. METHODOLOGY: The study was conducted in the calvarium of six rabbits. Standardized bone defects (diameter 4 mm) were trephined, and different haemostatic agents were applied and compared with control defects: bone wax (left for 10 min), Stasis (ferric sulphate, left for 5 s), Expasyl (aluminium chloride, left for 2 min and left permanently in situ), and a combination of Expasyl (2 min) and Stasis (5 s). The sites were photographed before the application and after the removal of the haemostatic agents. Three independent examiners judged the initial and final bleeding (on the photographs) using a bleeding score for each site and treatment. The results were compared using Wilcoxon's signed rank test. For the histologic analysis, three animals were killed after 3 weeks and three animals after 12 weeks. Transverse, nondecalcified sections were stained with combined basic fuchsin and toluidine blue for descriptive histology. RESULTS: The most efficient haemorrhage control was provided by Expasyl in combination with Stasis and by Expasyl alone, whereas bone wax had the weakest bleeding reduction effect. The histologic analysis after 3 weeks demonstrated an inflammatory and foreign body tissue response towards all haemostatic agents. At 12 weeks, this tissue response was less pronounced but still present in sites treated with bone wax or Expasyl. In general, the inflammatory tissue reactions were limited to the bone defects, and never extended into the surrounding tissues. CONCLUSIONS: Expasyl alone or in combination with Stasis appeared to be the most efficient of tested agents to control the bleeding within the bony defects created in a rabbit calvarium model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total cross sections for neutron scattering from nuclei, with energies ranging from 10 to 600 MeV and from many nuclei spanning the mass range 6Li to 238U, have been analyzed using a simple, three-parameter, functional form. The calculated cross sections are compared with results obtained by using microscopic (g-folding) optical potentials as well as with experimental data. The functional form reproduces those total cross sections very well. When allowance is made for Ramsauer-like effects in the scattering, the parameters of the functional form required vary smoothly with energy and target mass. They too can be represented by functions of energy and mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past decade, a significant amount of research has been conducted internationally with the aim of developing, implementing, and verifying "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures. Application of these methods permits comprehensive assessment of the actual failure modes and ultimate strengths of structural systems in practical design situations, without resort to simplified elastic methods of analysis and semi-empirical specification equations. Advanced analysis has the potential to extend the creativity of structural engineers and simplify the design process, while ensuring greater economy and more uniform safety with respect to the ultimate limit state. The application of advanced analysis methods has previously been restricted to steel frames comprising only members with compact cross-sections that are not subject to the effects of local buckling. This precluded the use of advanced analysis from the design of steel frames comprising a significant proportion of the most commonly used Australian sections, which are non-compact and subject to the effects of local buckling. This thesis contains a detailed description of research conducted over the past three years in an attempt to extend the scope of advanced analysis by developing methods that include the effects of local buckling in a non-linear analysis formulation, suitable for practical design of steel frames comprising non-compact sections. Two alternative concentrated plasticity formulations are presented in this thesis: the refined plastic hinge method and the pseudo plastic zone method. Both methods implicitly account for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the methods for the analysis of steel frames comprising non-compact sections has been established by comparison with a comprehensive range of analytical benchmark frame solutions. Both the refined plastic hinge and pseudo plastic zone methods are more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations. For example, the pseudo plastic zone method predicts the ultimate strength of the analytical benchmark frames with an average conservative error of less than one percent, and has an acceptable maximum unconservati_ve error of less than five percent. The pseudo plastic zone model can allow the design capacity to be increased by up to 30 percent for simple frames, mainly due to the consideration of inelastic redistribution. The benefits may be even more significant for complex frames with significant redundancy, which provides greater scope for inelastic redistribution. The analytical benchmark frame solutions were obtained using a distributed plasticity shell finite element model. A detailed description of this model and the results of all the 120 benchmark analyses are provided. The model explicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. Its accuracy was verified by comparison with a variety of analytical solutions and the results of three large-scale experimental tests of steel frames comprising non-compact sections. A description of the experimental method and test results is also provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the behaviour of very high strength (VHS) circular steel tubes strengthened by carbon fibre reinforced polymer (CFRP) and subjected to axial tension. A series of tests were conducted with different bond lengths and number of layers. The distribution of strain through the thickness of CFRP layers and along CFRP bond length was studied. The strain was found to generally decrease along the CFRP bond length far from the joint. The strain through the thickness of the CFRP layers was also found to decrease from bottom to top layer. The effective bond length for high modulus CFRP was established. Finally empirical models were developed to estimate the maximum load for a given CFRP arrangement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The LiteSteel Beam (LSB) is a new hollow flange section with a unique geometry consisting of torsionally rigid rectangular hollow flanges and a relatively slender web. It is subjected to lateral distortional buckling when used as flexural members, which reduces its member moment capacity. An investigation into the flexural behaviour of LSBs using experiments and numerical analyses led to the development of new design rules for LSBs subject to lateral distortional buckling. However, the comparison of moment capacity results with the new design rules showed that they were conservative for some LSB sections while slightly unconservative for others due to the effects of section geometry. It is also unknown whether these design rules are applicable to other hollow flange sections such as hollow flange beams (HFB). This paper presents the details of a study into the lateral distortional buckling behaviour of hollow flange sections such as LSBs, HFBs and their variations. A geometrical parameter defined as the ratio of flange torsional rigidity to the major axis flexural rigidity of the web (GJf/EIxweb) was found to be a critical parameter in evaluating the lateral distortional buckling behaviour and moment capacities of hollow flange sections. New design rules were therefore developed by using a member slenderness parameter modified by K, where K is a function of GJf/EIxweb. The new design rules based on the modified slenderness parameter were found to be accurate in calculating the moment capacities of not only LSBs and HFBs, but also other types of hollow flange sections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of urban morphology has become an expanding field of research within the architectural discipline, providing theories to be used as tools in the understanding and design of urban landscapes from the past, the present and into the future. Drawing upon contemporary architectural design theory, this investigation reveals what a sectional analysis of an urban landscape can add to the existing research methods within this field. This paper conducts an enquiry into the use of the section as a tool for urban morphological analysis. Following the methodology of the British school of urban morphology, sections through the urban fabric of the case study city of Brisbane are compared. The results are categorised to depict changes in scale, components and utilisation throughout various timeframes. The key findings illustrate how the section, when read in conjunction with the plan can be used to interpret changes to urban form and the relationship that this has to the quality of the urban environment in the contemporary city.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual-mode vibration of nanowires has been reported experimentally through actuation of the nanowire at its resonance frequency, which is expected to open up a variety of new modalities for the NEMS that could operate in the nonlinear regime. In the present work, we utilize large scale molecular dynamics simulations to investigate the dual-mode vibration of <110> Ag nanowires with triangular, rhombic and truncated rhombic cross-sections. By incorporating the generalized Young-Laplace equation into Euler-Bernoulli beam theory, the influence of surface effects on the dual-mode vibration is studied. Due to the different lattice spacing in principal axes of inertia of the {110} atomic layers, the NW is also modeled as a discrete system to reveal the influence from such specific atomic arrangement. It is found that the <110> Ag NW will under a dual-mode vibration if the actuation direction is deviated from the two principal axes of inertia. The predictions of the two first mode natural frequencies by the classical beam model appear underestimated comparing with the MD results, which are found to be enhanced by the discrete model. Particularly, the predictions by the beam theory with the contribution of surface effects are uniformly larger than the classical beam model, which exhibit better agreement with MD results for larger cross-sectional size. However, for ultrathin NWs, current consideration of surface effects is still experiencing certain inaccuracy. In all, for all different cross-sections, the inclusion of surface effects is found to reduce the difference between the two first mode natural frequencies. This trend is observed consistent with MD results. This study provides a first comprehensive investigation on the dual-mode vibration of <110> oriented Ag NWs, which is supposed to benefit the applications of NWs that acting as a resonating beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin-sectioned samples mounted on glass slides with common petrographic epoxies cannot be easily removed (for subsequent ion-milling) by standard methods such as heating or dissolution in solvents. A method for the removal of such samples using a radio frequency (RF) generated oxygen plasma has been investigated for a number of typical petrographic and ceramic thin sections. Sample integrity and thickness were critical factors that determined the etching rate of adhesive and the survivability of the sample. Several tests were performed on a variety of materials in order to estimate possible heating or oxidation damage from the plasma. Temperatures in the plasma chamber remained below 138°C and weight changes in mineral powders etched for 76 hr were less than ±4%. A crystal of optical grade calcite showed no apparent surface damage after 48 hr of etching. Any damage from the oxygen plasma is apparently confined to the surface of the sample, and is removed during the ion-milling stage of transmission electron microscopy (TEM) sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon fibre reinforced polymer (CFRP) sheets have many outstanding properties such as high strength, high elastic modulus, light weight and good durability which are made them a suitable alternative for steel in strengthening work. This paper describe the ultimate load carrying capacity of steel hollow sections at effective bond length in terms of its cross sectional area and the stress distribution within bond region for different layers CFRP. It was found that depending on their size and orientation of uni- directional CFRP layers, the ultimate tensile load was different. Along with these tests, non linear finite element analysis was also performed to validate the ultimate load carrying capacity depending on their cross sections. The predicted ultimate loads from FE analysis are found very close to the laboratory test results. The validated model has been used to determine the stress distribution at bond joint for different orientation of CFRP. This research shows the effect of stress distribution and suitable wrapping layer to be used for the strengthening of steel hollow sections in tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Application of "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures permits direct and accurate determination of ultimate system strengths, without resort to simplified elastic methods of analysis and semi-empirical specification equations. However, the application of advanced analysis methods has previously been restricted to steel frames comprising only compact sections that are not influenced by the effects of local buckling. A refined plastic hinge method suitable for practical advanced analysis of steel frame structures comprising non-compact sections is presented in a companion paper. The method implicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the method for the analysis of steel frames comprising non-compact sections is established in this paper by comparison with a comprehensive range of analytical benchmark frame solutions. The refined plastic hinge method is shown to be more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations.