842 resultados para non-invasive blood pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study's objective was to realize comparisons among different acepromazine, chlorpromazine and methotrimeprazine doses, evaluate parametric changes, test analgesia using press and term algimetry, and evaluate bispectral condition. 90 mongrel dogs were used, male and female, adult, weighting 10 to 15 Kg as a rule, distributed in 9 groups with 10 animals each. At first, second and third groups acepromazine was used at 0,1; 0,05 e 0,025 mg/Kg, respectively. At forth, fifth and sixth groups, chlorpromazine was used at 1,0; 0,5 and 0,25 mg/Kg, respectively. At seventh, eighth and ninth groups, methotrimeprazine at 1,0; 0,5 and 0,25 mg/Kg was used, respectively. All drugs were administered intravenously. objects of study: heart rate (HR), non invasive blood pressure (SAP, MAP, DAP), respiratory rate (f), capnography (ETCO(2)), pulse oxymetry (SatO(2)), mouth and rectal temperature, bispectral index (BIS), electromyography (EMG%), press and term algimetry. Somatic analgesia was evaluated by animal's response to nociceptives stimulus. We concluded that chlorpromazine had more bypotension. Dogs showed higher hypnosis level at: chlorpromazine group, with evident myorelaxation. All groups showed analgesia to thermic and mechanic stimulus. Acepromazine group showed high duration to both pain stimuli. Bispectral index was shorten at chlorpromazine group at 1,0 mg/kg doses, showing higher hypnosis index, and acepromazine was the less depressing considering the bispectral index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Verificar o efeito sedativo da clonidina, um a2-agonista, e do midazolam, um benzodiazepínico, quando utilizados na medicação pré-anestésica, empregando-se avaliação clínica e eletroencefalográfica bispectral. MÉTODO: Após aprovação institucional e consentimento escrito fornecido, 45 pacientes de 18 a 65 anos, estado físico ASA I, foram aleatoriamente distribuídos nos grupos placebo (P), clonidina (C) ou midazolam (M), em que receberam, respectivamente placebo, 150 µg de clonidina ou 15 mg de midazolam por via oral, 60 minutos antes da indução da anestesia (n = 15 por grupo). A monitorização constituiu-se de eletrocardiograma (D II), pressão arterial não invasiva, freqüência cardíaca, saturação de pulso de oxigênio, freqüência respiratória, temperatura axilar e da sala de cirurgia e eletroencefalograma bispectral para determinação do índice bispectral (BIS). Esses atributos e a escala de sedações (1 - ansioso, 2 - calmo, 3 - sonolento, 4 - dormindo com reflexo, 5 - dormindo sem reflexo) foram obtidos aos 0 (M0), 15 (M15), 30 (M30), 40 (M40), 50 (M50) e 60 (M60) minutos após a medicação. RESULTADOS: Nos grupos não houve alteração significante dos parâmetros respiratórios, hemodinâmicos e de temperatura. Houve diferença significante entre os grupos na ES (M60: M=C>P) e no BIS (M50 e M60: M=C>P). CONCLUSÕES: Nas condições utilizadas, a clonidina e o midazolam determinaram níveis de sedação adequados e semelhantes na medicação pré-anestésica de pacientes estado físico ASA I, quando avaliados pela escala de sedação e pelo índice bispectral, sem determinarem alterações hemodinâmicas e respiratórias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Due to the high incidence of technical and neurological complications, continuous spinal blocks were not performed for several years. With the advent of intermediate catheters the technique has been used more often and gaining acceptance among anesthesiologists. The objective of this report was to demonstrate the usefulness of the technique as a viable alternative for medium and major size surgeries. CASE REPORT: This is a 58 years old female patient, weighing 62 kg, physical status ASA I, with a history of migraines, low back pain, and prior surgeries under spinal block without intercurrence. The patient was scheduled for exploratory laparotomy for a probable pelvic tumor. After venoclysis with an 18G catheter, monitoring with cardioscope, non-invasive blood pressure and pulse oximetry was instituted; she was sedated with 2 mg of midazolam and 100 μg of fentanyl, and placed in left lateral decubitus. The patient underwent continuous spinal block through the median approach in L 3-L 4; 9 mg of 0.5% hyperbaric bupivacaine and 120 μ g of morphine sulfate were administered. Inspection of the abdominal cavity revealed a gastric stromal tumor that required an increase in the incision for a partial gastrectomy. A small dose of hyperbaric solution was required for the entire procedure, which was associated with complete hemodynamic stability. Postoperative admission to the ICU was not necessary; the patient presented a good evolution without complaints and with a high degree of satisfaction. She was discharged from the hospital after 72 hours without intercurrence. CONCLUSIONS: Intermediate catheters used in continuous spinal blocks have shown the potential to turn it an attractive and useful technique in medium and large size surgeries and it can even be an effective alternative in the management of critical patients to whom hemodynamic repercussions can be harmful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. Methods We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. Results Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. Conclusion StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive, real-time dynamic monitoring of pressure inside a column with the aid of Fiber Bragg Grating (FBG) sensor is presented in the present work. A bare FBG sensor is adhered on the circumference of a pressure column normal to its axis, which has the ability to acquire the hoop strain induced by the pressure variation inside the column. Pressure induced hoop strain response obtained using FBG sensor is validated against the pressure measurements obtained from conventional pressure gauge. Further, a protrusion setup on the outer surface of the column has been proposed over which a secondary FBG sensor is bonded normal to its axis, in order to increase the gauge length of this FBG sensor. This is carried out in order to validate the variation in sensitivity of the protrusion bonded FBG sensor compared to the bare FBG sensor bonded over the surface. A comparative study is done between the two FBG sensors and a conventional pressure gauge in order to establish the capacity of FBG sensor obtained hoop strain response for pressure monitoring inside the column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A real-time VHF swept frequency (20–300 MHz) reflectometry measurement for radio-frequency capacitive-coupled atmospheric pressure plasmas is described. The measurement is scalar, non-invasive and deployed on the main power line of the plasma chamber. The purpose of this VHF signal injection is to remotely interrogate in real-time the frequency reflection properties of plasma. The information obtained is used for remote monitoring of high-value atmospheric plasma processing. Measurements are performed under varying gas feed (helium mixed with 0–2% oxygen) and power conditions (0–40 W) on two contrasting reactors. The first is a classical parallel-plate chamber driven at 16 MHz with well-defined electrical grounding but limited optical access and the second is a cross-field plasma jet driven at 13.56 MHz with open optical access but with poor electrical shielding of the driven electrode. The electrical measurements are modelled using a lumped element electrical circuit to provide an estimate of power dissipated in the plasma as a function of gas and applied power. The performances of both reactors are evaluated against each other. The scalar measurements reveal that 0.1% oxygen admixture in helium plasma can be detected. The equivalent electrical model indicates that the current density between the parallel-plate reactor is of the order of 8–20 mA cm-2 . This value is in accord with 0.03 A cm-2 values reported by Park et al (2001 J. Appl. Phys. 89 20–8). The current density of the cross-field plasma jet electrodes is found to be 20 times higher. When the cross-field plasma jet unshielded electrode area is factored into the current density estimation, the resultant current density agrees with the parallel-plate reactor. This indicates that the unshielded reactor radiates electromagnetic energy into free space and so acts as a plasma antenna.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The identification of pre-clinical microvascular damage in hypertension by non-invasive techniques has proved frustrating for clinicians. This proof of concept study investigated whether entropy, a novel summary measure for characterizing blood velocity waveforms, is altered in participants with hypertension and may therefore be useful in risk stratification.

Methods: Doppler ultrasound waveforms were obtained from the carotid and retrobulbar circulation in 42 participants with uncomplicated grade 1 hypertension (mean systolic/diastolic blood pressure (BP) 142/92 mmHg), and 26 healthy controls (mean systolic/diastolic BP 116/69 mmHg). Mean wavelet entropy was derived from flow-velocity data and compared with traditional haemodynamic measures of microvascular function, namely the resistive and pulsatility indices.

Results: Entropy, was significantly higher in control participants in the central retinal artery (CRA) (differential mean 0.11 (standard error 0.05 cms(-1)), CI 0.009 to 0.219, p 0.017) and ophthalmic artery (0.12 (0.05), CI 0.004 to 0.215, p 0.04). In comparison, the resistive index (0.12 (0.05), CI 0.005 to 0.226, p 0.029) and pulsatility index (0.96 (0.38), CI 0.19 to 1.72, p 0.015) showed significant differences between groups in the CRA alone. Regression analysis indicated that entropy was significantly influenced by age and systolic blood pressure (r values 0.4-0.6). None of the measures were significantly altered in the larger conduit vessel.

Conclusion: This is the first application of entropy to human blood velocity waveform analysis and shows that this new technique has the ability to discriminate health from early hypertensive disease, thereby promoting the early identification of cardiovascular disease in a young hypertensive population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectifs : Le bruxisme survenant au cours du sommeil est un trouble du mouvement caractérisé par du grincement de dents et l’activité rythmique des muscles masticateurs (ARMM). Le bruxisme/ARMM est souvent associé à des mouvements du corps et des à éveils corticaux. Une séquence d’activation précède le ARMM/bruxisme. Ces événements incluent une augmentation des variables suivants : l’activité sympathique (-4 minutes), les activités encéphalographique (-4 second), le fréquence cardiaque, l’amplitude de la respiration (-1 second) et l’activité des muscle suprahyoïdiens (-0.8 second). La présente étude a examiné l’association entre le bruxisme et les changements de la pression artérielle. Méthodes: Dix sujets avec le bruxisme (5 hommes, 5 femmes, âge moyen = 26 ± 1,8) ont complétés 3 nuits de polysomnographie qui comprenait l'enregistrement non invasive de la pression artérielle. La première nuit a servi de dépistage et d’habituation au laboratoire. L'analyse a été réalisée sur les deuxièmes et troisièmes nuits enregistrements. Seuls les épisodes de bruxisme isolés survenant au cours du stade 2 du sommeil ont été utilisés pour l’analyse, pour un total de 65 épisodes. Les mesures des pressions systolique et diastolique ont été prises 20 battements avant et 23 battements après l'apparition de chaque épisode bruxisme lors du sommeil. Les épisodes de bruxisme ont été classés comme suit: 1) bruxisme avec éveil cortical; 2) bruxisme avec mouvement du corps (MC), 3) bruxisme avec éveil cortical et MC. Une quatrième catégorie, bruxisme seul, a également été analysée, mais utilisée comme donnée préliminaire puisque la catégorie se composait de seulement 4 épisodes de bruxisme. Résultats: Les deux pressions systolique et diastolique ont augmenté avec les épisodes de bruxisme. Cette augmentation a été statistiquement significative pour la pression systolique et diastolique pour les épisodes de bruxisme avec éveil cortical et/ou MC (p ≤ 0,05). L’augmentation moyenne de la pression (systolique / diastolique ± SE) a été : 28,4 ± 2,4/13,2 ± 1,5 mm Hg pour le bruxisme avec éveil cortical; 30,7 ± 1,6/19.4 ± 2.3 mm Hg pour bruxisme avec MC; 26.4 ± 2,8 / 14,6 ± 2.0mm Hg pour bruxisme avec éveil cortical et MC; 22,9 ± 5,2/12,4 ± 3,3mm Hg pour les épisodes de bruxisme seuls. Conclusion: Le bruxisme du sommeil est associé à des hausses de la pression artérielle pendant le sommeil. Cette hausse est supérieure dans les épisodes de bruxisme associés à un éveil cortical et / ou MC, qui sont souvent associés avec les événements bruxisme. Ces résultats sont en accord avec nos observations antérieures, où le bruxisme est précédé par une augmentation de l'activité sympathique et de la tachycardie sinusale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le traitement chirurgical des anévrismes de l'aorte abdominale est de plus en plus remplacé par la réparation endovasculaire de l’anévrisme (« endovascular aneurysm repair », EVAR) en utilisant des endoprothèses (« stent-grafts », SGs). Cependant, l'efficacité de cette approche moins invasive est compromise par l'incidence de l'écoulement persistant dans l'anévrisme, appelé endofuites menant à une rupture d'anévrisme si elle n'est pas détectée. Par conséquent, une surveillance de longue durée par tomodensitométrie sur une base annuelle est nécessaire ce qui augmente le coût de la procédure EVAR, exposant le patient à un rayonnement ionisants et un agent de contraste néphrotoxique. Le mécanisme de rupture d'anévrisme secondaire à l'endofuite est lié à une pression du sac de l'anévrisme proche de la pression systémique. Il existe une relation entre la contraction ou l'expansion du sac et la pressurisation du sac. La pressurisation résiduelle de l'anévrisme aortique abdominale va induire une pulsation et une circulation sanguine à l'intérieur du sac empêchant ainsi la thrombose du sac et la guérison de l'anévrisme. L'élastographie vasculaire non-invasivenon-invasive vascular elastography », NIVE) utilisant le « Lagrangian Speckle Model Estimator » (LSME) peut devenir une technique d'imagerie complémentaire pour le suivi des anévrismes après réparation endovasculaire. NIVE a la capacité de fournir des informations importantes sur l'organisation d'un thrombus dans le sac de l'anévrisme et sur la détection des endofuites. La caractérisation de l'organisation d'un thrombus n'a pas été possible dans une étude NIVE précédente. Une limitation de cette étude était l'absence d'examen tomodensitométrique comme étalon-or pour le diagnostic d'endofuites. Nous avons cherché à appliquer et optimiser la technique NIVE pour le suivi des anévrismes de l'aorte abdominale (AAA) après EVAR avec endoprothèse dans un modèle canin dans le but de détecter et caractériser les endofuites et l'organisation du thrombus. Des SGs ont été implantés dans un groupe de 18 chiens avec un anévrisme créé dans l'aorte abdominale. Des endofuites de type I ont été créés dans 4 anévrismes, de type II dans 13 anévrismes tandis qu’un anévrisme n’avait aucune endofuite. L'échographie Doppler (« Doppler ultrasound », DUS) et les examens NIVE ont été réalisés avant puis à 1 semaine, 1 mois, 3 mois et 6 mois après l’EVAR. Une angiographie, une tomodensitométrie et des coupes macroscopiques ont été réalisées au moment du sacrifice. Les valeurs de contrainte ont été calculées en utilisant l`algorithme LSME. Les régions d'endofuite, de thrombus frais (non organisé) et de thrombus solide (organisé) ont été identifiées et segmentées en comparant les résultats de la tomodensitométrie et de l’étude macroscopique. Les valeurs de contrainte dans les zones avec endofuite, thrombus frais et organisé ont été comparées. Les valeurs de contrainte étaient significativement différentes entre les zones d'endofuites, les zones de thrombus frais ou organisé et entre les zones de thrombus frais et organisé. Toutes les endofuites ont été clairement caractérisées par les examens d'élastographie. Aucune corrélation n'a été trouvée entre les valeurs de contrainte et le type d'endofuite, la pression de sac, la taille des endofuites et la taille de l'anévrisme.