900 resultados para new collection technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Force measurement in hypervelocity expansion tubes is not possible using conventional techniques. The stress wave force balance technique can be applied in expansion tubes to measure forces despite the short test times involved. This paper presents a new calibration technique for multiple-component stress wave force balances where an impulse response created using a load distribution is required and no orthogonal surfaces on the model exist.. This new technique relies on the tensorial superposition of single-component impulse responses analogous to the vectorial superposition of the calibration loads. The example presented here is that of a scale model of the Mars Pathfinder, but the technique is applicable to any geometry and may be useful for cases where orthogonal loads cannot be applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the estuary of the Mamanguape River (Paraíba, Brazil), a new collection technique was developed and applied with virgin poles of mangrove trees Avicennia schaueriana (Verbenaceae), Rhizophora mangle (Rhizophoraceae), and Laguncularia racemosa (Combretaceae), taking into account wood preference, water salinity and depth influence during teredinid larval settlement. Sets of poles were vertically fixed in the riverbed at three sites along a decreasing salinity gradient, where they stayed for four months. The poles were collected and divided into upper, median, and lower segments, in agreement with different immersion regimes. An increase of 239% was obtained in the number of individuals when compared to a previous study in the same area using a different methodology. The species Teredo bartschi (Clapp, 1923), Nausitora fusticula (Jeffreys, 1860) and Bankia fimbriatula Moll & Roch, 1931 were registered in both studies, and the species Psiloteredo healdi (Bartsch, 1931) is here registered for the first time as occurring in that estuary. The species Neoteredo reynei (Bartsch, 1920), previously registered on tree branches of the mangrove habitat, was not found in the present work. Bankia fimbriatula, the most abundant species, did not show preference for any substratum but occurred significantly on the lower segment of the poles. N. fusticula, second in abundance, preferred to settle on poles of A. schaueriana and on any of the three segments. Aiming to assess the habitat variations, a more accurate study on teredinids diversity in mangrove ecosystems should be performed through a concomitant analysis from tree branches of the mangrove habitat, as well as from poles of mangrove trees or panels made of pine wood or mangrove trees wood. These collection devices should be maintained along a decreasing salinity gradient exposed to different tide levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Abdominoperineal resection (APR) following radiotherapy is associated with a high rate of perineal wound complications. The anterolateral thigh (ALT) flap, combined with the vastus lateralis (VL) muscle, can cover complex perineal and pelvic anteroposterior defects. This is used for the first time transabdominally through the pelvis and the perineum (TAPP) in the infero-posterior directions; this technique has been described and illustrated in this study. METHODS: Among over 90 patients who underwent perineal reconstruction between May 2004 and June 2011, six patients presented high-grade tumours invading perineum, pelvis and sacrum, thereby resulting in a continuous anteroposterior defect. ALT + VL TAPP reconstructions were performed after extended APR and, subsequently, sacrectomy. Patients were examined retrospectively to determine demographics, operative time, complications (general and flap-related), time to complete healing and length of hospital stay. Long-term flap coverage, flap volume stability and functional and aesthetic outcomes were assessed. RESULTS: Mean operating time of the reconstruction was 290 min. No deaths occurred. One patient presented partial flap necrosis. Another patient presented a novel wound dehiscence after flap healing, due to secondary skin dissemination of the primary tumour. Following volumetric flap analysis on serial post-operative CT scans, no significant flap atrophy was observed. All flaps fully covered the defects. No late complications such as fistulas or perineal hernias occurred. Donor-site recovery was uneventful with no functional deficits. CONCLUSIONS: The use of the ALT + VL flap transabdominally is an innovative method to reconstruct exceptionally complex perineal and pelvic defects extending up to the lower back. This flap guarantees superior bulk, obliterating all pelvic dead space, with the fascia lata (FL) supporting the pelvic floor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lichenologists and users of lichenometry have long used calipers or photogrammetry to measure the growth of crustose lichens. Now, digital photography and popular computer software provide methodological alternatives. This thesis developed and tested a new methodology for tracking change and growth of the lichen, Rhizocarpon geographicum. Adobe Photoshop CS3 Extended software and a photographic time series (1996,2003,2006 and 2007) were used to measure thallus diameter, area, prothallus width and areolae area in 115 small R. geographicum thalli (0.53-1049.88 mm2 ). Measures of 8 diameters per thallus showed that change in diameter was highly variable and is a weak index of growth. Thallus area was a reliable measure of growth (power correlation, R2 = 0.89). Rapid, highly irregular growth occurred in small thalli «30 mm2 ), and steady, uniform growth occurred in larger thalli (>30 mm2 ). This new methodology is tedious but can potentially generate accurate and precise measures for even the tiniest of lichens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the technologies for the fabrication of high quality microarray advances rapidly, quantification of microarray data becomes a major task. Gridding is the first step in the analysis of microarray images for locating the subarrays and individual spots within each subarray. For accurate gridding of high-density microarray images, in the presence of contamination and background noise, precise calculation of parameters is essential. This paper presents an accurate fully automatic gridding method for locating suarrays and individual spots using the intensity projection profile of the most suitable subimage. The method is capable of processing the image without any user intervention and does not demand any input parameters as many other commercial and academic packages. According to results obtained, the accuracy of our algorithm is between 95-100% for microarray images with coefficient of variation less than two. Experimental results show that the method is capable of gridding microarray images with irregular spots, varying surface intensity distribution and with more than 50% contamination

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction A high saturated fatty acid intake is a well recognized risk factor for coronary heart disease development. More recently a high intake of n-6 polyunsaturated fatty acids (PUFA) in combination with a low intake of the long chain n-3 PUFA, eicosapentaenoic acid and docosahexaenoic acid has also been implicated as an important risk factor. Aim To compare total dietary fat and fatty acid intake measured by chemical analysis of duplicate diets with nutritional database analysis of estimated dietary records, collected over the same 3-day study period. Methods Total fat was analysed using soxhlet extraction and subsequently the individual fatty acid content of the diet was determined by gas chromatography. Estimated dietary records were analysed using a nutrient database which was supplemented with a selection of dishes commonly consumed by study participants. Results Bland & Altman statistical analysis demonstrated a lack of agreement between the two dietary assessment techniques for determining dietary fat and fatty acid intake. Conclusion The lack of agreement observed between dietary evaluation techniques may be attributed to inadequacies in either or both assessment techniques. This study highlights the difficulties that may be encountered when attempting to accurately evaluate dietary fat intake among the population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flow along rivers, an integral part of many cities, might provide a key mechanism for ventilation – which is important for air quality and heat stress. Since the flow varies in space and time around rivers, there is limited utility in point measurements. Ground-based remote sensing offers the opportunity to study 3D flow in locations which are hard to observe. For three months in the winter and spring of 2011, the atmospheric flow above the River Thames in central London was observed using a scanning Doppler lidar, a dual-beam scintillometer and sonic anemometry. First, an inter-comparison showed that lidar-derived mean wind-speed estimates compare almost as well to sonic anemometers (root-mean-square error (rmse) 0.65–0.68 m s–1) as comparisons between sonic anemometers (0.35–0.73 m s–1). Second, the lidar duo-beam scanning strategy provided horizontal transects of wind vectors comparison with scintillometer rmse 1.12–1.63 m s–1) which revealed mean and turbulent flow across the river and surrounds; in particular: chanelling flow along the river and turbulence changes consistent with the roughness changes between built to river environments. The results have important consequences for air quality and dispersion around urban rivers, especially given that many cities have high traffic rates on bankside roads.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pathoanatomic studies have failed to map accurately the primary lymphatic landing sites of the urinary bladder.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous Kirschner wire fixation represents the classic treatment for displaced supracondylar humeral fractures in childhood. This type of treatment first requires satisfactory reduction of the fracture. Failure to achieve a satisfactory reduction or inadequate stabilization can result in instability of the fracture fragments, which can result in either an unsatisfactory cosmetic or functional outcome. In our experience, these problems can be overcome with the use of a small lateral external fixator. METHODS: Between 1999 and 2005, thirty-one of 170 Gartland type-III supracondylar humeral fractures were treated with a lateral external fixator. The outcome of treatment was analyzed with regard to limb alignment, elbow movement, cosmetic appearance, and patient satisfaction. RESULTS: In twenty-eight of the thirty-one patients, a satisfactory reduction was achieved with closed methods. All children except one had a normal or good range of movement. The cosmetic result was excellent in all cases. All of the children and their parents stated that they would choose this treatment again. CONCLUSIONS: The use of a small lateral external fixator seems to be a safe alternative for the treatment of displaced supracondylar fractures of the humerus when a closed reduction appears to be unattainable by means of manipulation alone or when sufficient stability is not achieved with standard methods of Kirschner wire fixation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A compact system based on time-resolved diffuse reflectance spectroscopy (TDRS) has been developed to measure internal fruit quality parameters and has been applied to the non-destructive estimation of firmness, sugar content and acidity of kiwifruits. This new optical technique, developed in medical applications and related areas, provides a complete optical characterisation of a diffusive sample as it estimates at the same time and independently the light absorption inside the tissues and the scattering across them. The working principle of the technique is the analysis of the attenuation and broadening of the time-distribution of the remitted light, and the correct interpretation with a proper theoretical model. This main advantage compared to conventional optical techniques (which are only able to register the global attenuation spectrum) added to the compact, portable prototype developed along a three-year work opens the possibilities of this new measurement method in the food industry.