998 resultados para nasal cannula therapy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: High-flow nasal cannulae (HFNC) create positive oropharyngeal airway pressure but it is unclear how their use affects lung volume. Electrical impedance tomography (EIT) allows assessment of changes in lung volume by measuring changes in lung impedance. Primary objectives were to investigate the effects of HFNC on airway pressure (Paw) and end-expiratory lung volume (EELV), and to identify any correlation between the two. Secondary objectives were to investigate the effects of HFNC on respiratory rate (RR), dyspnoea, tidal volume and oxygenation; and the interaction between body mass index (BMI) and EELV. Methods: Twenty patients prescribed HFNC post-cardiac surgery were investigated. Impedance measures, Paw, PaO2/FiO2 ratio, RR and modified Borg scores were recorded first on low flow oxygen (nasal cannula or Hudson face mask) and then on HFNC. Results: A strong and significant correlation existed between Paw and end-expiratory lung impedance (EELI) (r=0.7, p<0.001). Compared with low flow oxygen, HFNC significantly increased EELI by 25.6% (95% CI 24.3, 26.9) and Paw by 3.0 cmH2O (95% CI 2.4, 3.7). RR reduced by 3.4 breaths per minute (95% CI 1.7, 5.2) with HFNC use, tidal impedance variation increased by 10.5% (95% CI 6.1, 18.3) and PaO2/FiO2 ratio improved by 30.6 mmHg (95% CI 17.9, 43.3). HFNC improved subjective dyspnoea scoring (p=0.023). Increases in EELI were significantly influenced by BMI, with larger increases associated with higher BMIs (p<0.001). Conclusions: This study suggests that HFNC improve dyspnoea and oxygenation by increasing both EELV and tidal volume, and are most beneficial in patients with higher BMIs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design--consumer-grade pumps, medical tubing, and regulators--it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Fisioterapia - FCT

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nasopharyngeal oxygen (NPO) therapy may overcome some of the difficulties associated with nasal prongs and facemask oxygen delivery devices. In response to a lack of published studies of NPO therapy in adults, we conducted a prospective randomised crossover trial to compare the effectiveness of NPO, nasal prongs (NP) and facemasks (FM) when used in an adult population (n=37) from the intensive care unit and general hospital wards. We measured oxygen saturation (Sp[O.sub.2]) using pulse oximetry, oxygen flow (litres per minute), respiration rate (per minute) and comfort using a horizontal visual analogue scale. All three devices were effective in maintaining a Sp[O.sub.2] of [greater than or equal to]95% (NP 97.0[+ or -]1.9, NPO 97.7[+ or -]1.7, FM 98.8[+ or -]1.3%). NPO therapy consumed less oxygen than NP and FM therapy (NP 2.6[+ or -]1.0, NPO 2.2[+ or -]0.9, FM 6.1[+ or -]0.4 l/min, P <0.001). There was no significant difference in patients' respiratory rates (NP 19.9[+ or -]3.2, NPO 19.9[+ or -]3.0, FM 19.8[+ or -]3.1 per minute, P=0.491). In terms of comfort, patients rated NP higher than NPO and FM using a horizontal visual analogue scale (100 mm=most comfortable) (NP 65.5[+ or -]14.3, NPO 62.8[+ or -]19.4, FM 49.4[+ or -]21.4 mm, P <0.001). We conclude that for adult patients, nasal prongs and nasopharyngeal oxygen therapy consume less oxygen and provide greater comfort than facemasks while still maintaining Sp[O.sub.2] [greater than or equal to]95%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to develop a mucoadhesive stimuli-sensitive drug delivery system for nasal administration of zidovudine (AZT). The system was prepared by formulating a low viscosity precursor of a liquid crystal phase, taking advantage of its lyotropic phase behavior. Flow rheology measurements showed that the formulation composed of PPG-5-CETETH-20, oleic acid and water (55, 30, 15% w/w), denominated P, has Newtonian flow behavior. Polarized light microscopy (PLM) revealed that formulation P is isotropic, whereas its 1:1 (w/w) dilution with artificial nasal mucus (ANM) changed the system to an anisotropic lamellar phase (PD). Oscillatory frequency sweep analysis showed that PD has a high storage modulus (G′) at nasal temperatures. Measurement of the mucoadhesive force against excised porcine nasal mucosa or a mucin disk proved that the transition to the lamellar phase tripled the work of mucoadhesion. Ex vivo permeation studies across porcine nasal mucosa exhibited an 18-fold rise in the permeability of AZT from the formulation. The Weibull mathematical model suggested that the AZT is released by Fickian diffusion mechanisms. Hence, the physicochemical characterization, combined with ex vivo studies, revealed that the PPG-5-CETETH-20, oleic acid, and water formulation could form a mucoadhesive matrix in contact with nasal mucus that promoted nasal absorption of the AZT. For an in vivo assessment, the plasma concentrations of AZT in rats were determined by HPLC method following intravenous and intranasal administration of AZT-loaded P formulation (PA) and AZT solution, respectively, at a dose of 8 mg/kg. The intranasal administration of PA resulted in a fast absorption process (Tmax = 6.7 min). Therefore, a liquid crystal precursor formulation administered by the nasal route might represent a promising novel tool for the systemic delivery of AZT and other antiretroviral drugs. In the present study, the uptake of AZT absorption in the nasal mucosa was demonstrated, providing new foundations for clinical trials in patients with AIDS. © 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulmonary fluid clearance is regulated by the active transport of Na+ and Cl- through respiratory epithelial ion channels. Ion channel dysfunction contributes to the pathogenesis of various pulmonary fluid disorders including high-altitude pulmonary edema (HAPE) and neonatal respiratory distress syndrome (RDS). Nasal potential difference (NPD) measurement allows an in vivo investigation of the functionality of these channels. This technique has been used for the diagnosis of cystic fibrosis, the archetypal respiratory ion channel disorder, for over a quarter of a century. NPD measurements in HAPE and RDS suggest constitutive and acquired dysfunction of respiratory epithelial Na+ channels. Acute lung injury (ALI) is characterized by pulmonary edema due to alveolar epithelial-interstitial-endothelial injury. NPD measurement may enable identification of critically ill ALI patients with a susceptible phenotype of dysfunctional respiratory Na+ channels and allow targeted therapy toward Na+ channel function. text of link

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present experiments were undertaken to pharmacologically characterize a noninvasive, chronic, experimental dog model of nasal congestion with the overall goal of developing an effective tool for studying the mechanism of action of nasal decongestant drugs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) using a haematoporphyrin derivative (Photogem (R), General Physics Institute and clustes Ltda) as photosensitizer and light emitting diodes (LEDs) as the light source was evaluated in 12 cats with cutaneous squamous cell carcinoma. Lesions were illuminated with LEDs, (300 J/cm for 30 min) 24 h after the administration of the photosensitizer. Clinical responses were classified as complete disappearance of the tumour with total re-epithelialization; partial response (a reduction greater than 50%); and no response (less than 50% reduction). Tumours localized to the pinna treated with one (n = 3) or two (n = 4) applications of PDT yielded no response. Highly invasive tumours of the nose and nasal planum also showed no response, after two treatments (n = 2). A combination of PDT and surgery was performed in three cases. Two cats showed partial response and one complete response with one application of therapy 30 days after nasal surgery. Small and noninfiltrative lesions (n = 3) of the nasal planum showed a PR with one application (n = 2) and a CR with two applications (n = 1). This study shows that PDT using Photogem (R) and LEDs can provide local control of low-grade feline squamous cell carcinoma. The addition of PDT to surgery in more invasive cases may help prevent recurrence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução O espelho de Glatzel (EG) é correntemente utilizado em consultórios fonoaudiológicos para a avaliação rápida da permeabilidade nasal. O mesmo foi descrito inicialmente em 1898 por Zwaardemaker. Porém, estudos de validação inexistem na literatura. Este estudo teve por objetivos verificar a reprodutibilidade do EG e a correlação intra-sujeito entre área de condensação e percepção subjetiva de permeabilidade nasal. Material e Métodos Vinte e cinco sujeitos foram avaliados com o EG por cinco minutos consecutivos (475 medidas por sujeito); cada meia hora por quatro horas; cada dia no início da tarde, por cinco dias e toda a quinta-feira por cinco semanas consecutivas. Utilizou-se uma escala análoga visual para avaliar a percepção de respiração nos períodos de horas, dias e semanas. Resultados O coeficiente de correlação total (área direita mais esquerda) encontrado entre área de condensação e percepção subjetiva foi de r=0,04 (p=0,3761). No lado esquerdo foi de r=0,08 (p=0,0984) e no lado direito de r=0,05 (p=0,2862). Os coeficientes de variação unilaterais medianos foram menores que 15% e os totais menores que 12%, independente do intervalo de tempo entre teste e re-teste. Conclusão Não se evidenciou correlação significativa entre a percepção subjetiva e a área de condensação nasal. A variabilidade unilateral foi maior do que quando considerados os valores totais (direito mais esquerdo) e não houve diferença na variabilidade das medidas de área de condensação nasal nos diferentes momentos do tempo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)