988 resultados para multimode-interference-type device
Resumo:
Differential Phase Shift Keying (DPSK) modulation format has been shown as a robust solution for next-generation optical transmission systems. One key device enabling such systems is the delay interferometer, converting the signal phase information into intensity modulation to be detected by the photodiodes. Usually, Mach-Zehnder interferometer (MZI) is used for demodulating DPSK signals. In this paper, we developed an MZI which is based on all-fiber Multimode Interference (MI) structure: a multimode fiber (MMF) located between two single-mode fibers (SMF) without any transition zones. The standard MZI is not very stable since the two beams go through two different paths before they recombine. In our design the two arms of the MZI are in the same fiber, which will make it less temperature-sensitive than the standard MZI. Performance of such MZI will be analyzed from transmission spectrum. Finally such all-fiber MI-based MZI (MI-MZI) is used to demodulate 10 Gbps DPSK signals. The demodulated signals are analyzed from eye diagram and bit error rate (BER).
Resumo:
Differential Phase Shift Keying (DPSK) modulation format has been shown as a robust solution for next-generation optical transmission systems. One key device enabling such systems is a delay interferometer, converting the phase modulation signal into the intensity modulation signal to be detected by the photodiodes. Usually, a standard Mach-Zehnder interferometer (MZI) is used for demodulating a DPSK signal. In this paper, we develop an MZI which is based on all-fiber Multimode Interference (MI) structure: a multimode fiber (MMF) with a central dip, located between two single-mode fibers (SMFs) without any transition zones. The MI based MZI (MI-MZI) is more stable than the standard MZI as the two arms share the same MMF, reducing the impact of the external effects, such as temperature and others. Performance of this MI-MZI is analyzed theoretically and experimentally from transmission spectrum. Experimental results shows that high interference extinction ratio is obtained, which is far higher than that obtained from a normal graded-index based MI-MZI. Finally, by software simulation, we demonstrate that our proposed MI-MZI can be used for demodulating a 40 Gbps DPSK signal. The performance of the MI-MZI based DPSK receiver is analyzed from the sensitivity. Simulation results show that sensitivity of the proposed receiver is about -22.3 dBm for a BER of 10-15 and about -23.8 dBm for a BER of 10-9.
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia
Resumo:
In this thesis an electric propulsion system is designed on a device level using Cadence ORCAD. The vehicle belongs to the Helsinki Metropolia University of Applied Sci-ences and it is to compete in the Automotive X-Prize competition held in the USA. In this thesis the electric propulsion system and related electric safety measures are designed. Also electro-magnetic compatibility and interferences present in the system are examined by examining the birth mechanisms and transmission paths of interference. Per device effects of interference and solutions to minimize them were examined and proposed. Suitability of permanent magnet synchronous machines for passenger vehicle use was examined by examining the torque production capability of the motor and the torque requirements of the vehicle. Also a short overview of history of electric vehicles is given.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Adhesive restorations have increasingly been used in dentistry, and the adhesive system application technique may determine the success of the restorative procedure. The aim of this study was to evaluate the influence of the application technique of two adhesive systems (Clearfil SE Bond and Adper Scotchbond MultiPurpose) on the bond strength and adhesive layer of composite resin restorations. Eight human third molars were selected and prepared with Class I occlusal cavities. The teeth were restored with composite using various application techniques for both adhesives, according to the following groups (n = 10): group 1 (control), systems were applied and adhesive was immediately light activated for 20 seconds without removing excesses; group 2, excess adhesive was removed with a gentle jet of air for 5 seconds; group 3, excess was removed with a dry microbrush-type device; and group 4, a gentle jet of air was applied after the microbrush and then light activation was performed. After this, the teeth were submitted to microtensile testing. For the two systems tested, no statistical differences were observed between groups 1 and 2. Groups 3 and 4 presented higher bond strength values compared with the other studied groups, allowing the conclusion that excess adhesive removal with a dry micro-brush could improve bond strength in composite restorations. Predominance of adhesive fracture and thicker adhesive layer were observed via scanning electron microscopy (SEM) in groups 1 and 2. For groups 3 and 4, a mixed failure pattern and thinner adhesive layer were verified. Clinicians should be aware that excess adhesive may negatively affect bond strength, whereas a thin, uniform adhesive layer appears to be favorable. (Quintessence Int 2013;44:9-15)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Photonic structures with a sub-wavelength pitch, small enough to suppress diffraction, can behave as equivalent homogenous materials that can be engineered to exhibit a specific refractive index and dispersion. Here we discuss the design of a variety of integrated photonic devices, ranging from grating couplers to multimode interference couplers, for which the use of sub-wavelength structures enables unique characteristics. We will place special emphasis on the design and experimental demonstration of multi-mode interference couplers with an unprecedented bandwidth beyond 200nm at telecom wavelengths.
Resumo:
This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (Sao Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a conical geometry with spiral impellers, showing characteristics that are intermediate between a centrifugal VAD and an axial VAD. The effectiveness of this new type of blood pumping principle was showed by tests and by using it in heart surgery for external blood circulation. However, the developed VAD uses a combination of ball bearings and mechanical seals, limiting the life for some 10 h, making impossible its long-term use or its use as an implantable VAD. As a part of development of an implantable VAD, this work aims at the replacement of ball bearings by a magnetic bearing. The most important magnetic bearing principles are studied and the magnetic bearing developed by Escola Politecnica of Sao Paulo University (EPUSP-MB) is elected because of its very simple architecture. Besides presenting the principle of the EPUSP-MB, this work presents one possible alternative for applying the EPUSP-MB in the IDPC-VAD.
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. Results: For permanent teeth, the LFpen cut‑off were 0– 27 (sound), 28– 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0– 7 (sound), 8– 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. Conclusion: LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.
Resumo:
AIM To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. MATERIALS AND METHODS A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. RESULTS For permanent teeth, the LFpen cut‑off were 0- 27 (sound), 28- 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0- 7 (sound), 8- 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. CONCLUSION LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.
Resumo:
The gene encoding tissue-type plasminogen activator (t-PA) is an immediate response gene, downstream from CREB-1 and other constitutively expressed transcription factors, which is induced in the hippocampus during the late phase of long-term potentiation (L-LTP). Mice in which the t-PA gene has been ablated (t-PA-/-) showed no gross anatomical, electrophysiological, sensory, or motor abnormalities but manifest a selective reduction in L-LTP in hippocampal slices in both the Schaffer collateral-CA1 and mossy fiber-CA3 pathways. t-PA-/- mice also exhibit reduced potentiation by cAMP analogs and D1/D5 agonists. By contrast, hippocampal-dependent learning and memory were not affected in these mice, whereas performance was impaired on two-way active avoidance, a striatum-dependent task. These results provide genetic evidence that t-PA is a downstream effector gene important for L-LTP and show that modest impairment of L-LTP in CA1 and CA3 does not result in hippocampus-dependent behavioral phenotypes.