968 resultados para multi-cervical unit
Resumo:
External stimulus/loading initiates adaptations within skeletal muscle. It has been previously found that the cervical area has the highest loading while performing flying maneuvers under +Gz. The first purpose of this study was to examine the neck muscle response to the physical environment associated with flight training, incorporating limited exposure to +Gz force, in a Pilatus PC-9 aircraft. The second purpose was to examine the short-term range of movement (ROM) response to flight training. Isometric cervical muscle strength and ROM was monitored in 9 RAAF pilots completing an 8-mo flight-training course at Pearce Airbase in Western Australia, and in 10 controls matched for gender, age, height, and weight. Isometric cervical muscle strength and ROM were measured at baseline and at 8 mo using the multi-cervical rehabilitation unit (Hanoun Medical, Downsview, Ontario, Canada). Results indicated that an increase in pilot neck strength was limited to flexion while in a neutral position. No strength changes were recorded in any other site in the pilots or for the controls. These findings suggest that short-term exposure to the physical environment associated with flight training had a limited significant effect on increasing isometric cervical muscle strength. No significant changes were observed in pilot ROM, indicating that short-term exposure to flight does not effect ROM.
Resumo:
Objective To compare two neck strength training modalities. Background Neck injury in pilots flying high performance aircraft is a concern in aviation medicine. Strength training may be an effective means to strengthen the neck and decrease injury risk. Methods The cohort consisted of 32 age-height-weight matched participants, divided into two experimental groups; the Multi-Cervical Unit (MCU) and Thera-Band tubing groups (THER), and a control (CTRL) group. Ten weeks of training were undertaken and pre-and post isometric strength testing for all groups was performed on the MCU. Comparisons between the three groups were made using a Kruskal-Wallis test and effect sizes between the MCU and the THER groups and the THER and CTRL groups were also calculated. Results The MCU group displayed the greatest increase in isometric strength (flexion 64.4%, extension 62.9%, left lateral flexion 53.3%, right lateral flexion 49.1%) and differences were only statistically significant (p<0.05) when compared to the CTRL group. Increases in neck strength for the THER group were lower than that shown in the MCU group (flexion 42.0%, extension 29.9%, left lateral flexion 26.7%, right lateral flexion 24.1%). Moderate to large effect sizes were found between the MCU and THER as well as the THER and CTRL groups. Conclusions This study demonstrated that the MCU was the most effective training modality to increase isometric cervical muscle strength. Thera-Band tubing did however, produce moderate gains in isometric neck strength
Resumo:
This paper describes some new wireless sensor hardware developed for pastoral and environmental applications. From our early experiments with Mote hardware we were inspired to develop our devices with improved radio range, solar power capability, mechanical and electrical robustness, and with unique combinations of sensors. Here we describe the design and evolution of a small family of devices: radio/processor board, a soil moisture sensor interface, and a single board multi-sensor unit for animal tracking experiments.
Resumo:
The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS) which aims to harness potential growth in order to correct spinal deformity. This study compared through in-vitro experiments the biomechanical response of two different rod designs under axial rotation loading. The study showed that a new design of telescoping growing rod preserved the rotational flexibility of the spine in comparison with rigid rods indicating them to be a more physiological way to improve the spinal deformity.
Resumo:
INTRODUCTION Managing spinal deformities in young children is challenging, particularly early onset scoliosis (EOS). Surgical intervention is often required if EOS has been unresponsive to conservative treatment particularly with rapidly progressive curves. An emerging treatment option for EOS is fusionless scoliosis surgery. Similar to bracing, this surgical option potentially harnesses growth, motion and function of the spine along with correcting spinal deformity. Dual growing rods are one such fusionless treatment, which aims to modulate growth of the vertebrae. The aim of this study was to ascertain the extent to which semiconstrained growing rods (Medtronic, Sofamor, Danek, Memphis, TN) with a telescopic sleeve component, reduce rotational constraint on the spine compared with standard "constrained / rigid" rods and hence potentially provide a more physiological mechanical environment for the growing spine. METHODS Six 40-60kg English Large White porcine spines served as a model for the paediatric human spine. Each spine was dissected into a 7 level thoracolumbar multi-segment unit (MSU), removing all non-ligamentous soft tissues and leaving 3cm of ribs either side. Pure nondestructive axial rotation moments of ±4Nm at a constant rotation rate of 8deg.s-1 were applied to the mounted MSU spines using a biaxial Instron testing machine. Displacement of each vertebral level was captured using a 3D motion tracking system (Optotrak 3020, Northern Digital Inc, Waterloo, ON). Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained growing rods and rigid rods in alternating sequence. The rods were secured by multi-axial pedicle screws (Medtronic CD Horizon) at levels 2 and 6 of the construct. The range of motion (ROM), neutral zone (NZ) size and stiffness (Nm.deg-1) were calculated from the Instron load-displacement data and intervertebral ROM was calculated through a MATLAB algorithm from Optotrak data. RESULTS Irrespective of the order of testing, rigid rods significantly reduced the total ROM compared with semi-constrained rods (p<0.05) with in a significantly stiffer spine for both left and right axial rotation (p<0.05). Analysing the intervertebral motion within the instrumented levels 2-6, rigid rods showed reduced ROM compared with semi-constrained growing rods and compared with un-instrumented motion segments. CONCLUSION Semi-constrained growing rods maintain similar stiffness in axial rotation to un-instrumented spines, while dual rigid rods significantly reduce axial rotation. Clinically the effect of semi-constrained growing rods as observed in this study is that they would be expected to allow growth via the telescopic rod components while maintaining the axial flexibility of the spine, which may reduce occurrence of the crankshaft phenomenon.
Resumo:
INTRODUCTION Managing spinal deformities in young children is challenging, particularly early-onset scoliosis (EOS). Any progressive spinal deformity particularly in early life presents significant health risks for the child and a challenge for the treating surgeon. Surgical intervention is often required if EOS has been unresponsive to conservative treatment particularly with rapidly progressive curves. An emerging treatment option particularly for EOS is fusionless scoliosis surgery. Similar to bracing this surgical option potentially harnesses growth, motion and function of the spine along with correcting spinal deformity. Dual growing rods is one such fusionless treatment, which aims to modulate growth of the vertebrae. The aim of this study was to ascertain the extent to which semi-constrained growing rods (Medtronic, Memphis, TN) with a telescopic sleeve component, reduce rotational constraint on the spine compared with standard rigid rods and hence potentially provide a more physiological mechanical environment for the growing spine. METHODS Six 40-60kg English Large White porcine spines served as a model for the paediatric human spine. Each spine was dissected into 7 level thoracolumbar multi-segment unit (MSU) spines, removing all non-ligamentous soft tissues. Appropriately sized semi-constrained growing rods and rigid rods were secured by multi-axial screws (Medtronic) prior to testing in alternating sequences for each spine. Pure nondestructive moments of +/4Nm at a constant rotation rate of 8deg/s was applied to the mounted MSU spines. Displacement of each level was captured using an Optotrak (Northern Digital Inc, Waterloo, ON). The range of motion (ROM), neutral zone (NZ) size and stiffness (Nm/deg) were calculated from the Instron load-displacement data and intervertebral ROM was calculated through a MATLAB algorithm from Optotrak data. RESULTS Irrespective of sequence order rigid rods significantly reduced the total ROM (deg) than compared to semi-constrained rods (p<0.05) and resulted in a significantly stiffer (Nm/deg) spine for both left and right axial rotation testing (p<0.05). Analysing the intervertebral motion within the instrumented levels, rigid rods showed reduced ROM (Deg) than compared to semi-constrained growing rods and the un-instrumented (UN-IN) test sequences. CONCLUSION The semi-constrained growing rods maintained rotation similar to UN-IN spines while the rigid rods showed significantly reduced axial rotation across all instrumented levels. Clinically the effect of semi-constrained growing rods evaluated in this study is that they will allow growth via the telescopic rod components while maintaining the axial rotation ability of the spine, which may also reduce the occurrence of the crankshaft phenomenon.
Resumo:
Background The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS), which aims of harness potential growth in order to correct spinal deformity. The purpose of this study was to compare the in-vitro biomechanical response of two different dual rod designs under axial rotation loading. Methods Six porcine spines were dissected into seven level thoracolumbar multi-segmental units. Each specimen was mounted and tested in a biaxial Instron machine, undergoing nondestructive left/right axial rotation to peak moments of 4Nm at a constant rotation rate of 8deg.s-1. A motion tracking system (Optotrak) measured 3D displacements of individual vertebrae. Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained growing rods and ‘rigid’ rods in alternating sequence. Range of motion, neutral zone size and stiffness were calculated from the moment-rotation curves and intervertebral ranges of motion were calculated from Optotrak data. Findings Irrespective of test sequence, rigid rods showed significantly reduction of total rotation across all instrumented levels (with increased stiffness) whilst semi-constrained rods exhibited similar rotation behavior to the un-instrumented (P<0.05). An 11% and 8% increase in stiffness for left and right axial rotation respectively and 15% reduction in total range of motion was recorded with dual rigid rods compared with semi-constrained rods. Interpretation Based on these findings, the semi-constrained growing rods do not increase axial rotation stiffness compared with un-instrumented spines. This is thought to provide a more physiological environment for the growing spine compared to dual rigid rod constructs.
Resumo:
Os óxidos de enxofre (SOx) são um dos maiores poluentes atmosféricos e um dos precursores da chuva ácida. Um levantamento feito na Petrobrás mostrou que cerca de 17% dos SOx emitidos numa refinaria são oriundos do processo de FCC. Com o avanço dos controles ambientais, traduzido numa legislação mais restritiva, a técnica de incorporação de aditivos para remoção de SOx em UFCCs apresenta-se como a alternativa de menor custo frente outras tecnologias de abate das emissões de SOx. No presente trabalho, foram estudados aditivos constituídos por compostos derivados de hidrotalcitas com a substituição parcial do magnésio e do alumínio por cobre e/ou manganês, sendo estes impregnados ou não por dióxido de cério. Estes aditivos foram submetidos a testes de desempenho em uma unidade multi-propósito acoplada a um micro-GC/TCD. Em todos os testes, a corrente gasosa para a etapa de adsorção oxidativa foi de 1700 ppm de SO2 e 1,5% O2 em He e, para a etapa de regeneração, 30% H2/He. No primeiro conjunto de testes, realizou-se uma adsorção a 720C de 10 min e regeneração com um patamar a 530C, seguido de um TPR até 800C. Observou-se que as amostras impregnadas com cério apresentaram o melhor desempenho na remoção de SO2, indicando que o cério pode ter um papel de promotor da oxidação de SO2 a SO3. Os resultados do TPR mostram que as amostras com cério e com manganês parecem apresentar menores temperaturas de redução dos sulfatos, apesar das maiores liberações de H2S serem identificadas nas amostras com cobre. No segundo conjunto de testes, a adsorção foi a 720C durante 35 min e a regeneração a 650C por 5 minutos em um patamar de 5 minutos, seguida de um TPR até 800C. Para os tempos de sulfatação curtos (5 e 10 min), os resultados confirmaram o efeito positivo que a incorporação de CeO2 apresenta sobre a adsorção oxidativa do SO2. Todavia, para tempos de reação maiores (35 min), não se observou uma correlação clara entre a composição química do catalisador e a quantidade total de SOx removida. Os aditivos foram ainda testados em ciclos de reação-regeneração em condições equivalentes ao segundo conjunto de testes descrito. De um modo geral, os aditivos que contêm cobre têm uma vida útil superior aos demais, possivelmente, pelo fato do cobre ter importante papel na regeneração do aditivo
Resumo:
在黑白仰鼻猴(Rhinopithecus bieti)分布区北端的南仁(99o04’E, 28o34’N), 野外工作分别于2001年4月10日 - 6月30 日(代表冬末和春季),9月14日 - 12月20日(夏秋季)进行。我们分别用粪便取样法、录像带记录和直接观察法收集了猴群生境的垂直利用、过夜处选择和社会组织数据。此外,我们于1998年8月20日到12月31日在中科院昆明动物研究所老所利用全发生取样法(All-Occurence sampling)收集了一个单雄多雌单元(One-male, multi-female unit: OMU)的性行为数据。另外,我们利用昆明动物所1994 - 2003年和昆明动物园1991 - 2003年笼养黑白仰鼻猴群的出生记录来说明出生季节和出生间隔。 黑白仰鼻猴群全年在3500 - 4300 m的林带上活动,集中利用的海拔带为3900 - 4200 m,这可能与猴群的主食(松萝)主要分布于高海拔有关。冬季, 山沟中的粪便密度高于山脊,这可能是猴群在沟中过夜的缘故。猴群喜欢在树高(27.5 ± 3.2 m)较高、胸径(57.9 ± 16.9 cm)和树冠(6.3 ± 1.4 m)大的针叶树(云冷杉)上过夜。猴群冬季喜欢在阳坡中部的针叶树上过夜,这样既安全又可以接受适量的阳光照射。这是猴群在选择最安全和最暖和过夜处的一种折衷策略。 1994年猴群OMUs大小为7.8 ± 1.7(n = 17),成年性比(M/F)是1.0: 3.8。2001年OMUs大小为10.1 ± 3.7 (n = 15),成年性比是1.0: 4.9。1994-2001年,OMUs中每个成年雌性每年的平均增长率是0.04。这种OMU-band两层社会组织与Kirkpatrick(1996)的报道一致。 雌性以匍匐地面或栖木上,同时面部和视线左右摆动,或者坐着上下移动头部的动作邀配;雄性则以伴有特别的叫声、露齿动颌表情邀配。在有射精记录的观察日中,平均每5.2次爬跨有1次射精,而单次爬跨就射精的仅占4.4%。雌性邀配了18次射精爬跨的大多数(72%),但163次非射精爬跨中她们邀配的仅为45%。雄性在射精交配中叫声多于非射精交配。该种交配模式与其它疣猴亚科动物相似,而性内交配竞争可能与这种模式的进化有关。 笼养黑白仰鼻猴群的出生日期为12 - 6月份,出生高峰期为3 - 5月份。猴群的平均出生日期为4月18日(标准差为43天),中位出生日期为4月10日。猴群的出生间隔平均为624 ± 150天(n = 15,范围:332 - 787天)。幼猴可活到1岁后的出生间隔(706 ± 71, n = 12, 498 - 787天)显著长于1岁内死亡或流产后的出生间隔(428 ± 87, n = 5, 332 - 568天)。婴猴性比(M/F)显著偏离1: 1。
Resumo:
Our attention, is focused on designing an optimal procurement mechanism which a buyer can use for procuring multiple units of a homogeneous item based on bids submitted by autonomous, rational, and intelligent suppliers. We design elegant optimal procurement mechanisms for two different situations. In the first situation, each supplier specifies the maximum quantity that can be supplied together with a per unit price. For this situation, we design an optimal mechanism S-OPT (Optimal with Simple bids). In the more generalized case, each supplier specifies discounts based on the volume of supply. In this case, we design an optimal mechanism VD-OPT (Optimal with Volume Discount, bids). The VD-OPT mechanism uses the S-OPT mechanism as a building block. The proposed mechanisms minimize the cost to the buyer, satisfying at the same time, (a) Bayesian, incentive compatibility and (b) interim individual rationality.
Resumo:
A high-speed path-following controller for long combination vehicles (LCVs) was designed and implemented on a test vehicle consisting of a rigid truck towing a dolly and a semitrailer. The vehicle was driven through a 3.5 m wide lane change maneuver at 80 km/h. The axles of the dolly and trailer were steered actively by electrically-controlled hydraulic actuators. Substantial performance benefits were recorded compared with the unsteered vehicle. For the best controller weightings, performance improvements relative to unsteered case were: lateral tracking error 75% reduction, rearward amplification (RA) of lateral acceleration 18% reduction, and RA of yaw rate 37% reduction. This represents a substantial improvement in stability margins. The system was found to work well in conjunction with the braking-based stability control system of the towing vehicle with no negative interaction effects being observed. In all cases, the stability control system and the steering system improved the yaw stability of the combination. © 2014 by ASME.
Resumo:
En entornos donde los recursos son precederos y la asignación de recursos se repite en el tiempo con el mismo conjunto o un conjunto muy similar de agentes, las subastas recurrentes pueden ser utilizadas. Una subasta recurrente es una secuencia de subastas donde el resultado de una subasta puede influenciar en las siguientes. De todas formas, este tipo de subastas tienen problemas particulares cuando la riqueza de los agentes esta desequilibrada y los recursos son precederos. En esta tesis se proponen algunos mecanismos justos o equitativos para minimizar los efectos de estos problemas. En una subasta recurrente una solución justa significa que todos los participantes consiguen a largo plazo sus objetivos en el mismo grado o en el grado más parecido posible, independientemente de su riqueza. Hemos demostrado experimentalmente que la inclusión de justicia incentiva a los bidders en permanecer en la subasta minimizando los problemas de las subastas recurrentes.