983 resultados para motion sensor


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the design of mobile sensor networks for optimal data collection. The development is strongly motivated by the application to adaptive ocean sampling for an autonomous ocean observing and prediction system. A performance metric, used to derive optimal paths for the network of mobile sensors, defines the optimal data set as one which minimizes error in a model estimate of the sampled field. Feedback control laws are presented that stably coordinate sensors on structured tracks that have been optimized over a minimal set of parameters. Optimal, closed-loop solutions are computed in a number of low-dimensional cases to illustrate the methodology. Robustness of the performance to the influence of a steady flow field on relatively slow-moving mobile sensors is also explored © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the problems of effective in situ measurement of the real-time strain for bridge weigh in motion in reinforced concrete bridge structures through the use of optical fiber sensor systems. By undertaking a series of tests, coupled with dynamic loading, the performance of fiber Bragg grating-based sensor systems with various amplification techniques were investigated. In recent years, structural health monitoring (SHM) systems have been developed to monitor bridge deterioration, to assess load levels and hence extend bridge life and safety. Conventional SHM systems, based on measuring strain, can be used to improve knowledge of the bridge's capacity to resist loads but generally give no information on the causes of any increase in stresses. Therefore, it is necessary to find accurate sensors capable of capturing peak strains under dynamic load and suitable methods for attaching these strain sensors to existing and new bridge structures. Additionally, it is important to ensure accurate strain transfer between concrete and steel, adhesives layer, and strain sensor. The results show the benefits in the use of optical fiber networks under these circumstances and their ability to deliver data when conventional sensors cannot capture accurate strains and/or peak strains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because of their learned avoidance of humans and the dense cover provided by forested areas, observation of coyote activity is often very limited in the Southeast. In this study we used digital motion-sensor cameras to detect activity among coyote populations in various urban and rural habitats. Camera stations were placed adjacent to regenerating clear cuts, forest trails and roads, agriculture fields, residential areas, and within city parks to determine activity and presence of coyotes in these various areas. Cameras were successful in detecting coyotes in all study sites throughout the year. Coyotes appear to show no avoidance of camera stations. Cameras may be helpful in gathering general biological and activity information on coyote populations in an area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En este proyecto, se presenta un informe técnico sobre la cámara Leap Motion y el Software Development Kit correspondiente, el cual es un dispositivo con una cámara de profundidad orientada a interfaces hombre-máquina. Esto es realizado con el propósito de desarrollar una interfaz hombre-máquina basada en un sistema de reconocimiento de gestos de manos. Después de un exhaustivo estudio de la cámara Leap Motion, se han realizado diversos programas de ejemplo con la intención de verificar las capacidades descritas en el informe técnico, poniendo a prueba la Application Programming Interface y evaluando la precisión de las diferentes medidas obtenidas sobre los datos de la cámara. Finalmente, se desarrolla un prototipo de un sistema de reconocimiento de gestos. Los datos sobre la posición y orientación de la punta de los dedos obtenidos de la Leap Motion son usados para describir un gesto mediante un vector descriptor, el cual es enviado a una Máquina Vectores Soporte, utilizada como clasificador multi-clase.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Biomechanical signals due to human movements during exercise are represented in time-frequency domain using Wigner Distribution Function (WDF). Analysis based on WDF reveals instantaneous spectral and power changes during a rhythmic exercise. Investigations were carried out on 11 healthy subjects who performed 5 cycles of sun salutation, with a body-mounted Inertial Measurement Unit (IMU) as a motion sensor. Variance of Instantaneous Frequency (I.F) and Instantaneous Power (I.P) for performance analysis of the subject is estimated using one-way ANOVA model. Results reveal that joint Time-Frequency analysis of biomechanical signals during motion facilitates a better understanding of grace and consistency during rhythmic exercise.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This project proposes an approach for supporting Indoor Navigation Systems using Pedestrian Dead Reckoning-based methods and by analyzing motion sensor data available in most modern smartphones. Processes suggested in this investigation are able to calculate the distance traveled by a user while he or she is walking. WLAN fingerprint- based navigation systems benefit from the processes followed in this research and results achieved to reduce its workload and improve its positioning estimations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this review was to examine the utility and accuracy of commercially available motion sensors to measure step-count and time spent upright in frail older hospitalized patients. A database search (CINAHL and PubMed, 2004–2014) and a further hand search of papers’ references yielded 24 validation studies meeting the inclusion criteria. Fifteen motion sensors (eight pedometers, six accelerometers, and one sensor systems) have been tested in older adults. Only three have been tested in hospital patients, two of which detected postures and postural changes accurately, but none estimated step-count accurately. Only one motion sensor remained accurate at speeds typical of frail older hospitalized patients, but it has yet to be tested in this cohort. Time spent upright can be accurately measured in the hospital, but further validation studies are required to determine which, if any, motion sensor can accurately measure step-count.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Wearable monitors are increasingly being used to objectively monitor physical activity in research studies within the field of exercise science. Calibration and validation of these devices are vital to obtaining accurate data. This article is aimed primarily at the physical activity measurement specialist, although the end user who is conducting studies with these devices also may benefit from knowing about this topic. Best Practices Initially, wearable physical activity monitors should undergo unit calibration to ensure interinstrument reliability. The next step is to simultaneously collect both raw signal data (e.g., acceleration) from the wearable monitors and rates of energy expenditure, so that algorithms can be developed to convert the direct signals into energy expenditure. This process should use multiple wearable monitors and a large and diverse subject group and should include a wide range of physical activities commonly performed in daily life (from sedentary to vigorous). Future Directions New methods of calibration now use "pattern recognition" approaches to train the algorithms on various activities, and they provide estimates of energy expenditure that are much better than those previously available with the single-regression approach. Once a method of predicting energy expenditure has been established, the next step is to examine its predictive accuracy by cross-validating it in other populations. In this article, we attempt to summarize the best practices for calibration and validation of wearable physical activity monitors. Finally, we conclude with some ideas for future research ideas that will move the field of physical activity measurement forward.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A vessel stabilizer control system includes a sensor fault detection means which senses the availability of sensing signals from a gyrostabilizer precession motion sensor and a vessel roll motion sensor. The control system controls the action of a gyro-actuator which is mechanically coupled to a gyrostabilizer. The benefit of employing fault sensing of the sensors providing the process control variables is that the sensed number of available process control variables (or sensors) can be used to activate a tiered system of control modes. Each tiered control mode is designed to utilize the available process control variables to ensure safe and effective operation of the gyrostabilizer that is tolerant of sensor faults and loss of power supply. A control mode selector is provided for selecting the appropriate control mode based on the number of available process control variables.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le diabète de type 1 (DT1) est une maladie complexe qui requiert une implication importante des patients pour contrôler leur glycémie et ainsi prévenir les complications et comorbidités. L’activité physique (AP) régulière et une attention constante pour les glucides ingérés sont des adjuvants essentiels au traitement insulinique. Nous avons démontré que le questionnaire BAPAD-1, spécifiquement développé pour des adultes atteints de DT1, est un outil valide (validité prédictive, fiabilité interne et reproductibilité) pour définir des barrières associées à l’AP. Bien que le niveau de barrières envers l’AP soit faible, la crainte de l’hypoglycémie est la barrière la plus importante chez cette population. L’adoption d’un mode de vie actif est associée à un profil corporel favorable. Les adultes, avec un DT1 et non diabétique, qui maintiennent un bon niveau d’AP, soit un ratio entre la dépense énergétique totale et celle au repos ≥ 1.7, ont une masse grasse, un indice de masse corporelle et un tour de taille significativement inférieurs à ceux d’adultes moins actifs. Le niveau d’AP peut être estimé au moyen d’un moniteur d’AP comme le SenseWear Armband™. Afin de compléter les études de validation de cet outil, nous avons évalué et démontré la reproductibilité des mesures. Toutefois, la dépense énergétique est sous-estimée durant les 10 premières minutes d’une AP d’intensité modérée sur ergocycle. L’utilisation de cet appareil est donc justifiée pour une évaluation de la dépense énergétique sur de longues périodes. Le calcul des glucides est une méthode largement utilisée pour évaluer la quantité d’insuline à injecter lors des repas. Nous avons évalué dans un contexte de vie courante, sans révision de la technique, la précision des patients pour ce calcul. L’erreur moyenne est de 15,4 ± 7,8 g par repas, soit 20,9 ± 9,7 % du contenu glucidique. L’erreur moyenne est positivement associée à de plus grandes fluctuations glycémiques mesurées via un lecteur de glucose en continu. Une révision régulière du calcul des glucides est probablement nécessaire pour permettre un meilleur contrôle glycémique. Nous avons développé et testé lors d’un essai clinique randomisé contrôlé un programme de promotion de l’AP (PEP-1). Ce programme de 12 semaines inclut une séance hebdomadaire en groupe ayant pour but d’initier l’AP, d’établir des objectifs et d’outiller les adultes atteints de DT1 quant à la gestion de la glycémie à l’AP. Bien que n’ayant pas permis d’augmenter la dépense énergétique, le programme a permis un maintien du niveau d’AP et une amélioration de la condition cardio-respiratoire et de la pression artérielle. À la fin du programme, une plus grande proportion de patients connaissait la pharmacocinétique de l’insuline et une plus grande variété de méthodes pour contrer l’hypoglycémie associée à l’AP était utilisée. En conclusion, le diabète de type 1 engendre des défis quotidiens particuliers. D’une part, le calcul des glucides est une tâche complexe et son imprécision est associée aux fluctuations glycémiques quotidiennes. D’autre part, l’adoption d’un mode de vie actif, qui est associée à un meilleur profil de composition corporelle, est limitée par la crainte des hypoglycémies. Le programme PEP-1 offre un support pour intégrer l’AP dans les habitudes de vie des adultes avec un DT1 et ainsi améliorer certains facteurs de risque cardio-vasculaire.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a different experimental setup compared with the traditional ones, in order to determine the acceleration of gravity, which is carried out by using a fluid at a constant rotation. A computerized rotational system-by using a data acquisition system with specific software, a power amplifier and a rotary motion sensor-is employed in order to evaluate the angular velocity and g. An equation to determine g is inferred from fluid mechanics. For this purpose, the fluid's parabolic shape inside a cylindrical receptacle is considered using a rotational movement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A monitoração dos níveis de prática de atividade física em segmentos da população jovem tem se tornado importante tema de interesse entre especialistas da área. O Objetivo do estudo foi verificar o nível de atividade física de escolares, baseando-se em duas recomendações vigentes, e analisar a existência de associações entre a quantidade de passos/dia e diferentes indicadores de adiposidade corporal. A casuística foi composta por 162 indivíduos de dez a 18 anos (65 do sexo masculino e 97 do sexo feminino). Foram calculados o Índice de Massa Corporal e o percentual de gordura por impedância bioelétrica. O nível de atividade física habitual foi mensurado por meio de pedômetro (New Lifestyles modelo NL-2000) e analisado de acordo com duas recomendações internacionais: Duncan et al. (masculino: 16.000 passos/dia e feminino: 13.000 passos/dia) e Tudor-Locke et al. (masculino: 15.000 passos/dia e feminino: 12.000 passos/dia). O teste t de Student e a ANOVA One-Away (Post Hoc - LSD) compararam os grupos formados. O nível de significância adotado foi de 5% (p£0,05). Dos resultados, apenas 18,5% da amostra cumpriu as recomendações propostas por Duncan e 25,9% cumpriram os pontos de corte propostos por Tudor-Locke et al.. Os adolescentes que não cumpriram as recomendações propostas por Duncan et al., apresentaram valores percentuais de gordura corporal maiores quando comparados aos jovens que cumpriram (p<0,05). Pode-se concluir que uma elevada taxa de jovens não cumpriu as duas recomendações analisadas, bem como, apenas um indicador de adiposidade associou-se com o cumprimento de umas das recomendações.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências da Motricidade - IBRC

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Zeitreihen sind allgegenwärtig. Die Erfassung und Verarbeitung kontinuierlich gemessener Daten ist in allen Bereichen der Naturwissenschaften, Medizin und Finanzwelt vertreten. Das enorme Anwachsen aufgezeichneter Datenmengen, sei es durch automatisierte Monitoring-Systeme oder integrierte Sensoren, bedarf außerordentlich schneller Algorithmen in Theorie und Praxis. Infolgedessen beschäftigt sich diese Arbeit mit der effizienten Berechnung von Teilsequenzalignments. Komplexe Algorithmen wie z.B. Anomaliedetektion, Motivfabfrage oder die unüberwachte Extraktion von prototypischen Bausteinen in Zeitreihen machen exzessiven Gebrauch von diesen Alignments. Darin begründet sich der Bedarf nach schnellen Implementierungen. Diese Arbeit untergliedert sich in drei Ansätze, die sich dieser Herausforderung widmen. Das umfasst vier Alignierungsalgorithmen und ihre Parallelisierung auf CUDA-fähiger Hardware, einen Algorithmus zur Segmentierung von Datenströmen und eine einheitliche Behandlung von Liegruppen-wertigen Zeitreihen.rnrnDer erste Beitrag ist eine vollständige CUDA-Portierung der UCR-Suite, die weltführende Implementierung von Teilsequenzalignierung. Das umfasst ein neues Berechnungsschema zur Ermittlung lokaler Alignierungsgüten unter Verwendung z-normierten euklidischen Abstands, welches auf jeder parallelen Hardware mit Unterstützung für schnelle Fouriertransformation einsetzbar ist. Des Weiteren geben wir eine SIMT-verträgliche Umsetzung der Lower-Bound-Kaskade der UCR-Suite zur effizienten Berechnung lokaler Alignierungsgüten unter Dynamic Time Warping an. Beide CUDA-Implementierungen ermöglichen eine um ein bis zwei Größenordnungen schnellere Berechnung als etablierte Methoden.rnrnAls zweites untersuchen wir zwei Linearzeit-Approximierungen für das elastische Alignment von Teilsequenzen. Auf der einen Seite behandeln wir ein SIMT-verträgliches Relaxierungschema für Greedy DTW und seine effiziente CUDA-Parallelisierung. Auf der anderen Seite führen wir ein neues lokales Abstandsmaß ein, den Gliding Elastic Match (GEM), welches mit der gleichen asymptotischen Zeitkomplexität wie Greedy DTW berechnet werden kann, jedoch eine vollständige Relaxierung der Penalty-Matrix bietet. Weitere Verbesserungen umfassen Invarianz gegen Trends auf der Messachse und uniforme Skalierung auf der Zeitachse. Des Weiteren wird eine Erweiterung von GEM zur Multi-Shape-Segmentierung diskutiert und auf Bewegungsdaten evaluiert. Beide CUDA-Parallelisierung verzeichnen Laufzeitverbesserungen um bis zu zwei Größenordnungen.rnrnDie Behandlung von Zeitreihen beschränkt sich in der Literatur in der Regel auf reellwertige Messdaten. Der dritte Beitrag umfasst eine einheitliche Methode zur Behandlung von Liegruppen-wertigen Zeitreihen. Darauf aufbauend werden Distanzmaße auf der Rotationsgruppe SO(3) und auf der euklidischen Gruppe SE(3) behandelt. Des Weiteren werden speichereffiziente Darstellungen und gruppenkompatible Erweiterungen elastischer Maße diskutiert.