989 resultados para modulation index


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel and simple method for measuring the chirp parameter, frequency, and intensity modulation indexes of directly modulated lasers is proposed in a small-signal modulation scheme. A graphical approach is presented. An analytical solution to the measurement of low chirp parameters is also given. The measured results agree well with those obtained using the conventional methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The J(1)...J(3) is a recent optical method for linear readout of dynamic phase modulation index in homodyne interferometers. In this work, the J(1)... J(3) method is applied to measure voltage in an optical voltage sensor. Based on the classical J(1)...J(4) method, the J(1)... J(3) technique shows to be more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is enhanced. The agreement between theoretical and experimental results, based on 1/f noise, is demonstrated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, a fixed-switching-frequency closed-loop modulation of a voltage-source inverter (VSI), upon the digital implementation of the modulation process, is analyzed and characterized. The sampling frequency of the digital processor is considered as an integer multiple of the modulation switching frequency. An expression for the determination of the modulation design parameter is developed for smooth modulation at a fixed switching frequency. The variation of the sampling frequency, switching frequency, and modulation index has been analyzed for the determination of the switching condition under closed loop. It is shown that the switching condition determined based on the continuous-time analysis of the closed-loop modulation will ensure smooth modulation upon the digital implementation of the modulation process. However, the stability properties need to be tested prior to digital implementation as they get deteriorated at smaller sampling frequencies. The closed-loop modulation index needs to be considered maximum while determining the design parameters for smooth modulation. In particular, a detailed analysis has been carried out by varying the control gain in the sliding-mode control of a two-level VSI. The proposed analysis of the closed-loop modulation of the VSI has been verified for the operation of a distribution static compensator. The theoretical results are validated experimentally on both single- and three-phase systems.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A few advanced bus-clamping pulse width modulation (ABCPWM) methods have been proposed recently for a three-phase inverter. With these methods, each phase is clamped, switched at nominal frequency, and switched at twice the nominal frequency in different regions of the fundamental cycle. This study proposes a generalised ABCPWM scheme, encompassing the few ABCPWM schemes that have been proposed and many more ABCPWM schemes that have not been reported yet. Furthermore, analytical closed-form expression is derived for the harmonic distortion factor corresponding to the generalised ABCPWM. This factor is independent of load parameters. The analytical expression derived here brings out the dependence of root-mean-square (RMS) current ripple on modulation index, and can be used to evaluate the RMS current ripple corresponding to any ABCPWM scheme. The analytical closed-form expression is validated experimentally in terms of measured weighted total harmonic distortion (THD) in line voltage (V-WTHD) and measured THD in line current (I-THD) on a 6 kW induction motor drive.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Optimal switching angles for minimization of total harmonic distortion of line current (I-THD) in a voltage source inverter are determined traditionally by imposing half-wave symmetry (HWS) and quarter-wave symmetry (QWS) conditions on the pulse width modulated waveform. This paper investigates optimal switching angles with QWS relaxed. Relaxing QWS expands the solution space and presents the possibility of improved solutions. The optimal solutions without QWS are shown here to outperform the optimal solutions with QWS over a range of modulation index (M) between 0.82 and 0.94 for a switching frequency to fundamental frequency ratio of 5. Theoretical and experimental results are presented on a 2.3kW induction motor drive.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PWM waveforms with positive voltage transition at the positive zero crossing of the fundamental voltage (type-A) are generally considered for PWM waveform with even number of switching angles per quarter whereas, waveforms with negative voltage transition at the positive zero crossing (type-B) are considered for odd number of switching angles per quarter. Optimal PWM, for minimization of total harmonic distortion of line to line (VWTHD), is generally solved with the aforementioned criteria. This paper establishes that a combination of both types of waveforms gives better performance than any individual type in terms of minimum VWTHD for complete range of modulation index (M). Optimal PWM for minimum VWTHD is solved for PWM waveforms with pulse numbers (P) of 5 and 7. Both type-A and type-B waveforms are found to be better in different ranges of M. The theoretical findings are confirmed through simulation and experimental results on a 3.7 kW squirrel cage induction motor in an open-loop V/f drive. Further, the optimal PWM is analysed from a space vector point of view.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

this paper quantifies effects of using three different pulse width modulation (PWM) schemes on the losses in the inverter and induction motor of a 1 kW drive. Direct measurements of losses have been made with a calorimeter. Results show that for the inverter, discontinuous PWM excitation reduces losses by up to 15% compared to sine and symmetrical space vector PWM methods. However, at a low modulation index the greater harmonic content with discontinuous PWM increased motor losses by nearly 20%. This study demonstrates the importance of careful choice of modulation scheme to achieve high overall drive efficiency. © 2005 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PRINCIPLES Prediction of arrhythmic events (AEs) has gained importance with the availability of implantable cardioverter-defibrillators (ICDs), but is still imprecise. This study evaluated the innovative Wedensky modulation index (WMI) as predictor of AEs. METHODS In this prospective cohort, 179 patients with coronary artery disease (CAD) referred for AE risk assessment underwent baseline evaluation including measurement of R-/T-wave WMI (WMI(RT)) and left ventricular ejection fraction (LVEF). Two endpoints were assessed 3 years after the baseline evaluation: sudden cardiac death or appropriate ICD event (EP1) and any cardiac death or appropriate ICD event (EP2). Associations between baseline predictors (WMI(RT) and LVEF) and endpoints were evaluated in regression models. RESULTS Only three patients were lost to follow-up. EP1 and EP2 occurred in 24 and 27 patients, respectively. WMI(RT) (odds ratio [OR] per 1 point increase for EP1 20.1, 95% confidence interval [CI] 1.8-221.4, p = 0.014, and for EP2 73.3, 95% CI 6.6-817.7, p <0.001) and LVEF (OR per 1% increase for EP1 0.94, 95% CI 0.90-0.99, p = 0.013, and for EP2 0.93, 95% CI 0.89-0.97, p = 0.002) were significantly associated with both endpoints. In bivariable regression controlled for LVEF, WMI(RT) was independently associated with EP1 (p = 0.047) and EP2 (p = 0.007). The combination of WMI(RT) ≥0.60 and LVEF ≤30% resulted in a positive predictive value of 36% for EP1 and 50% for EP2. CONCLUSIONS WMI(RT) is a significant predictor of AEs independent of LVEF and has potential to improve AE risk prediction in CAD patients. However, WMI(RT) should be evaluated in larger and independent samples before recommendations for clinical routine can be made.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents several shaft voltage reduction techniques for doubly-fed induction generators in wind turbine applications. These techniques includes: pulse width modulated voltage without zero vectors, multi-level inverters with proper PWM strategy, better generator design to minimize effective capacitive couplings in shaft voltage, active common-mode filter, reducing dc-link voltage and increasing modulation index. These methods have been verified with mathematical analysis and simulations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose Multi-level diode-clamped inverters have the challenge of capacitor voltage balancing when the number of DC-link capacitors is three or more. On the other hand, asymmetrical DC-link voltage sources have been applied to increase the number of voltage levels without increasing the number of switches. The purpose of this paper is to show that an appropriate multi-output DC-DC converter can resolve the problem of capacitor voltage balancing and utilize the asymmetrical DC-link voltages advantages. Design/methodology/approach A family of multi-output DC-DC converters is presented in this paper. The application of these converters is to convert the output voltage of a photovoltaic (PV) panel to regulate DC-link voltages of an asymmetrical four-level diode-clamped inverter utilized for domestic applications. To verify the versatility of the presented topology, simulations have been directed for different situations and results are presented. Some related experiments have been developed to examine the capabilities of the proposed converters. Findings The three-output voltage-sharing converters presented in this paper have been mathematically analysed and proven to be appropriate to improve the quality of the residential application of PV by means of four-level asymmetrical diode-clamped inverter supplying highly resistive loads. Originality/value This paper shows that an appropriate multi-output DC-DC converter can resolve the problem of capacitor voltage balancing and utilize the asymmetrical DC-link voltages advantages and that there is a possibility of operation at high-modulation index despite reference voltage magnitude and power factor variations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The planning of IMRT treatments requires a compromise between dose conformity (complexity) and deliverability. This study investigates established and novel treatment complexity metrics for 122 IMRT beams from prostate treatment plans. The Treatment and Dose Assessor software was used to extract the necessary data from exported treatment plan files and calculate the metrics. For most of the metrics, there was strong overlap between the calculated values for plans that passed and failed their quality assurance (QA) tests. However, statistically significant variation between plans that passed and failed QA measurements was found for the established modulation index and for a novel metric describing the proportion of small apertures in each beam. The ‘small aperture score’ provided threshold values which successfully distinguished deliverable treatment plans from plans that did not pass QA, with a low false negative rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bit-stream-based control, which uses one bit wide signals to control power electronics applications, is a new approach for controller design in power electronic systems. This study presents a novel family of three-phase space vector modulators, which are based on the bit-stream technique and suitable for three-phase inverter systems. Each of the proposed modulators simultaneously converts a two-phase reference to the three-phase domain and reduces switching frequencies to reasonable levels. The modulators do not require carrier oscillators, trigonometric functions or, in some cases, sector detectors. A complete three-phase modulator can be implemented in as few as 102 logic elements. The performance of the proposed modulators is compared through simulation and experimental testing of a 6 kW, three-phase DC-to-AC inverter. Subject to limits on the modulation index, the proposed modulators deliver spread-spectrum output currents with total harmonic distortion comparable to a standard carrier-based space vector pulse width modulator.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bit-Stream based control, which uses one bit wide signals to control power electronics applications, is a new approach for controller design in power electronic systems. Bit-Stream signals are inherently high frequency in nature, and as such some form of down sampling or modulating is essential to avoid excessive switching losses. This paper presents a novel three-phase space vector modulator, which is based on the Bit-Stream technique and suitable for standard three-phase inverter systems. The proposed modulator simultaneously converts a two phase reference to the three-phase domain and reduces switching frequencies to reasonable levels. The modulator consumes relatively few logic elements and does not require sector detectors, carrier oscillators or trigonometric functions. The performance of the modulator was evaluated using ModelSim. Results indicate that, subject to limits on the modulation index, the proposed modulator delivers a spread-spectrum output with total harmonic distortion comparable to standard space vector pulse width modulation techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity (FMC), modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 IMRT and VMAT treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams (p < 0.00008). For example, Values of SAS (with MLC apertures narrower than 10 mm defined as “small”) less than 0.2 also identified QA passing IMRT beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360◦ arcs or as 60◦ sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a multilevel inverter which produces hexagonal voltage space vector structure in lower modulation region and a 12-sided polygonal space vector structure in the over-modulation region. Normal conventional multilevel inverter produces 6n +/- 1 (n=odd) harmonics in the phase voltage during over-modulation and in the extreme square wave mode operation. However, this inverter produces a 12-sided polygonal space vector location leading to the elimination of 6n 1 (n=odd) harmonics in over-modulation region extending to a final 12-step mode operation. The inverter consists of three conventional cascaded two level inverters with asymmetric dc bus voltages. The switching frequency of individual inverters is kept low throughout the modulation index. In the low speed region, hexagonal space phasor based PWM scheme and in the higher modulation region, 12-sided polygonal voltage space vector structure is used. Experimental results presented in this paper shows that the proposed converter is suitable for high power applications because of low harmonic distortion and low switching losses.