983 resultados para minimal invasive surgery
Resumo:
Operative treatment of coronoid fracture often requires a large dissection of soft tissue, resulting in elbow stiffness and functional limitation. The authors present a minimal invasive, safe technique, useful in the case of isolated coronoid fracture associated with elbow dislocation. This technique does not require soft tissue dissection and allows an early unlimited resumption of sports activities.
Resumo:
AIM: Transanal minimal invasive surgery (TAMIS) of rectal lesions is increasingly being used, but the technique is not yet standardized. The aims of this study were to evaluate peri-operative complications and long-term functional outcome of the technique and to analyse whether or not the rectal defect needs to be closed. METHOD: Consecutive patients undergoing TAMIS using the SILS port (Covidien) and standard laparoscopic instruments were studied. RESULTS: Seventy-five patients (68% male) of mean age 67 (± 15) years underwent single-port transanal surgery at three different centres for 37 benign lesions and 38 low-risk cancers located at a mean of 6.4 ± 2.3 cm from the anal verge. The median operating time was 77 (25-245) min including a median time for resection of 36 (15-75) min and for closure of the rectal defect of 38 (9-105) min. The defect was closed in 53% using interrupted (75%) or a running suture (25%). Intra-operative complications occurred in six (8%) patients and postoperative morbidity was 19% with only one patient requiring reoperation for Grade IIIb local infection. There was no difference in the incidence of complications whether the rectal defect was closed or left open. Patients were discharged after 3.4 (1-21) days. At a median follow-up of 12.8 (2-29) months, the continence was normal (Vaizey score of 1.5; 0-16). CONCLUSION: Transanal rectal resection can be safely and efficiently performed by means of a SILS port and standard laparoscopic instruments. The rectal defect may be left open and at 1 year continence is not compromised.
Resumo:
Minimal invasive extracorporeal circulation (MiECC) systems have initiated important efforts within science and technology to further improve the biocompatibility of cardiopulmonary bypass components to minimize the adverse effects and improve end-organ protection. The Minimal invasive Extra-Corporeal Technologies international Society was founded to create an international forum for the exchange of ideas on clinical application and research of minimal invasive extracorporeal circulation technology. The present work is a consensus document developed to standardize the terminology and the definition of minimal invasive extracorporeal circulation technology as well as to provide recommendations for the clinical practice. The goal of this manuscript is to promote the use of MiECC systems into clinical practice as a multidisciplinary strategy involving cardiac surgeons, anaesthesiologists and perfusionists.
Resumo:
We read with great interest the large-scale network meta-analysis by Kowalewski et al. comparing clinical outcomes of patients undergoing coronary artery bypass grafting (CABG) operated on using minimal invasive extracorporeal circulation (MiECC) or off-pump (OPCAB) with those undergoing surgery on conventional cardiopulmonary bypass (CPB) [1]. The authors actually integrated into single study two recently published meta-analysis comparing MiECC and OPCAB with conventional CPB, respectively [2, 3] into a single study. According to the results of this study, MiECC and OPCAB are both strongly associated with improved perioperative outcomes following CABG when compared with CABG performed on conventional CPB. The authors conclude that MiECC may represent an attractive compromise between OPCAB and conventional CPB. After carefully reading the whole manuscript, it becomes evident that the role of MiECC is clearly undervalued. Detailed statistical analysis using the surface under the cumulative ranking probabilities indicated that MiECC represented the safer and more effective intervention regarding all-cause mortality and protection from myocardial infarction, cerebral stroke, postoperative atrial fibrillation and renal dysfunction when compared with OPCAB. Even though no significant statistical differences were demonstrated between MiECC and OPCAB, the superiority of MiECC is obvious by the hierarchy of treatments in the probability analysis, which ranked MiECC as the first treatment followed by OPCAB and conventional CPB. Thus, MiECC does not represent a compromise between OPCAB and conventional CPB, but an attractive dominant technique in CABG surgery. These results are consistent with the largest published meta-analysis by Anastasiadis et al. comparing MiECC versus conventional CPB including a total of 2770 patients. A significant decrease in mortality was observed when MiECC was used, which was also associated with reduced risk of postoperative myocardial infarction and neurological events [4]. Similarly, another recent meta-analysis by Benedetto et al. compared MiECC versus OPCAB and resulted in comparable outcomes between these two surgical techniques [5]. As stated in the text, superiority of MiECC observed in the current network meta-analysis, when compared with OPCAB, could be attributed to the fact that MiECC offers the potential for complete revascularization, whereas OPCAB poses a challenge for unexperienced surgeons; especially when distal marginal branches on the lateral and/or posterior wall of the heart need revascularization. This is reflected by a significantly lower number of distal anastomoses performed in OPCAB when compared with conventional CPB. Therefore, taking into consideration the literature published up to date, including the results of the current article, we advocate that MiECC should be integrated in the clinical practice guidelines as a state-of-the-art technique and become a standard practice for perfusion in coronary revascularization surgery.
Resumo:
Background: Presently the surgical approach to the adrenal gland is in a state of flux. While the traditional approach to the adrenal gland has been the open transabdominal technique, more recently laparoscopic approaches, particularly via the transabdominal route, have increasingly been utilized. However, laparoscopic intervention for the adrenal gland can be problematic in certain circumstances, particularly for large adrenal masses and in instances of adrenal malignancies. Methods: In this report we describe the use of hand-assisted laparoscopic adrenalectomy as an alternative minimal invasive surgical approach to the adrenal gland. Hand-assisted laparoscopic adrenalectomy using the HandPort system (Smith & Nephew, Sydney, Australia) was undertaken in three patients requiring adrenalectomy for mass lesions including one patient with Conn's syndrome. Results: In all three cases, surgery proceeded promptly and uneventfully. In the present paper, the details of the technique of hand-assisted adrenalectomy are described. This is the first report in the world literature of this new technique for the adrenal gland. Conclusions: Hand-assisted laparoscopic adrenalectomy is an easily performed technique, which can be completed within a short operative time span and which has the advantage of providing intraoperative tactile localization for the adrenal gland. It may be particularly applicable for large adrenal tumours, yet only involves the performance of a small abdominal incision. Postoperative recovery is comparable with that reported for the laparoscopic-only technique. Hand-assisted adrenalectomy is a new technique which has great potential and which warrants further evaluation.
Resumo:
STUDY DESIGN Technical note and case series. OBJECTIVE To introduce an innovative minimal-invasive surgical procedure reducing surgery time and blood loss in management of U-shaped sacrum fractures. SUMMARY OF BACKGROUND Despite their seldom appearance, U-shaped fractures can cause severe neurological deficits and surgical management difficulties. According to the nature of the injury normally occurring in multi-injured patients after a fall from height, a jump, or road traffic accident, U-shaped fractures create a spinopelvic dissociation and hence are highly unstable. In the past, time-consuming open procedures like large posterior constructs or shortening osteotomies with or without decompression were the method of choice, sacrificing spinal mobility. Insufficient restoration of sacrococcygeal angle and pelvic incidence with conventional techniques may have adverse long-term effects in these patients. METHODS In a consecutive series of 3 patients, percutaneous reduction of the fracture with Schanz pins inserted in either the pedicles of L5 or the S1 body and the posterior superior iliac crest was achieved. The Schanz pins act as lever, allowing a good manipulation of the fracture. The reduction is secured by a temporary external fixator to permit optimal restoration of pelvic incidence and sacral kyphosis. Insertion of 2 transsacral screws allow fixation of the restored spinopelvic alignment. RESULTS Anatomic alignment of the sacrum was possible in each case. Surgery time ranged from 90 to 155 minutes and the blood loss was <50 mL in all 3 cases. Two patients had very good results in the long term regarding maintenance of pelvic incidence and sacrococcygeal angle. One patient with previous cauda equina decompression had loss of correction after 6 months. CONCLUSIONS Percutaneous reduction and transsacral screw fixation offers a less invasive method for treating U-shaped fractures. This can be advantageous in treatment of patients with multiple injuries.
Resumo:
HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.
Resumo:
To evaluate patients with transverse fractures of the shaft of the humerus treated with indirect reduction and internal fixation with plate and screws through minimally invasive technique. Inclusion criteria were adult patients with transverse diaphyseal fractures of the humerus closed, isolated or not occurring within 15 days of the initial trauma. Exclusion criteria were patients with compound fractures. In two patients, proximal screw loosening occurred, however, the fractures consolidated in the same mean time as the rest of the series. Consolidation with up to 5 degrees of varus occurred in five cases and extension deficit was observed in the patient with olecranon fracture treated with tension band, which was not considered as a complication. There was no recurrence of infection or iatrogenic radial nerve injury. It can be concluded that minimally invasive osteosynthesis with bridge plate can be considered a safe and effective option for the treatment of transverse fractures of the humeral shaft. Level of Evidence III, Therapeutic Study.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2014