976 resultados para miniature portable


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Research is being conducted on the use of transcranial direct current stimulation (tDCS) for therapeutic effects, and also on the mechanisms through which such therapeutic effects are mediated. A bottleneck in the progress of the research has been the large size of the existing tDCS systems which prevents subjects from performing their daily activities. To help research into the principles, mechanisms, and benefits of tDCS, reduction of size and weight, improvement in simplicity and user friendliness, portability, and programmability of tDCS systems are vital. This paper presents a design for a low-cost, light-weight, programmable, and portable tDCS device. The device is head-mountable and can be concealed in a hat and worn on the head by the subject while receiving the stimulation. The strength of the direct current stimulation can be selected through a simple user interface. The device is constructed and its performance evaluated through bench and in vivo tests. The tests validated the operation of the device in inducing neuromodulatory changes in primary motor cortex, M1, through measuring excitability of dominant M1 of resting right first dorsal interosseus muscle by transcranial magnetic stimulation induced motor evoked potentials. It was observed that the tDCS device induced comparable neuromodulatory effects in M1 as the existing bulky tDCS systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tungsten coil atomic emission spectrometry is an ideal technique for field applications because of its simplicity, low cost, low power requirement, and independence from cooling systems. A new, portable, compact design is reported here. The tungsten coil is extracted from an inexpensive 24 V, 250 W commercial light bulb. The coil is housed in a small, aluminum cell. The emission signal exits from a small aperture in the cell, while the bulk of the blackbody emission from the tungsten coil is blocked. The resulting spectra exhibit extremely low background signals. The atomization cell, a single lens, and a hand-held charge coupled device (CCD) spectrometer are fixed on a 1 x 6 x 30 cm ceramic base. The resulting system is robust and easily transported. A programmable, miniature 400 W solid-state constant current power supply controls the temperature of the coil. Fifteen elements are determined with the system (Ba, Cs, Li, Rb, Cr, Sr, Eu, Yb, Mn, Fe, Cu, Mg, V, Al, and Ga). The precision ranges from 4.3% to 8.4% relative standard deviation for repetitive measurements of the same solution. Detection limits are in the 0.04 to 1500 mu g/L range. Accuracy is tested using standard reference materials for polluted water, peach leaves, and tomato leaves. For those elements present above the detection limit, recoveries range from 72% to 147%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system’s position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device’s projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Jing Ltd. miniature combustion aerosol standard (Mini-CAST) soot generator is a portable, commercially available burner that is widely used for laboratory measurements of soot processes. While many studies have used the Mini-CAST to generate soot with known size, concentration, and organic carbon fraction under a single or few conditions, there has been no systematic study of the burner operation over a wide range of operating conditions. Here, we present a comprehensive characterization of the microphysical, chemical, morphological, and hygroscopic properties of Mini-CAST soot over the full range of oxidation air and mixing N-2 flow rates. Very fuel-rich and fuel-lean flame conditions are found to produce organic-dominated soot with mode diameters of 10-60nm, and the highest particle number concentrations are produced under fuel-rich conditions. The lowest organic fraction and largest diameter soot (70-130nm) occur under slightly fuel-lean conditions. Moving from fuel-rich to fuel-lean conditions also increases the O:C ratio of the soot coatings from similar to 0.05 to similar to 0.25, which causes a small fraction of the particles to act as cloud condensation nuclei near the Kelvin limit (kappa similar to 0-10(-3)). Comparison of these property ranges to those reported in the literature for aircraft and diesel engine soots indicates that the Mini-CAST soot is similar to real-world primary soot particles, which lends itself to a variety of process-based soot studies. The trends in soot properties uncovered here will guide selection of burner operating conditions to achieve optimum soot properties that are most relevant to such studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Miniature direct methanol fuel cells (DMFCs) are promising micro power sources for portable appliction. Low temperature cofired ceramic (LTCC), a competitive technology for current MEMS based fabrication, provides cost-effective mass manufacturing route for miniature DMFCs. Porous silver tape is adapted as electrodes to replace the traditional porous carbon electrodes due to its compatibility to LTCC processing and other electrochemical advantages. Electrochemical evaluation of silver under DMFCs operating conditions demonstrated that silver is a good electrode for DMFCs because of its reasonable corrosion resistance, low passivating current, and enhanced catalytic effect. Two catalyst loading methods (cofiring and postfiring) of the platinum and ruthenium catalysts are evaluated for LTCC based processing. The electrochemical analysis exhibits that the cofired path out-performs the postfiring path both at the anode and cathode. The reason is the formation of high surface area precipitated whiskers. Self-constraint sintering is utilized to overcome the difficulties of the large difference of coefficient of thermal expansion (CTE) between silver and LTCC (Dupont 951) tape during cofiring. The graphite sheet employed as a cavity fugitive insert guarantees cavity dimension conservation. Finally, performance of the membrane electrode assembly (MEA) with the porous silver electrode in the regular graphite electrode based cell and the integrated cofired cell is measured under passive fuel feeding condition. The MEA of the regular cell performs better as the electrode porosity and temperature increased. The power density of 10 mWcm-2 was obtained at ambient conditions with 1M methanol and it increased to 16 mWcm -2 at 50°C from an open circuit voltage of 0.58V. For the integrated prototype cell, the best performance, which depends on the balance methanol crossover and mass transfer at different temperatures and methanol concentrations, reaches 1.13 mWcm-2 at 2M methanol solution at ambient pressure. The porous media pore structure increases the methanol crossover resistance. As temperature increased to 60°C, the device increases to 2.14 mWcm-2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a portable neural recording device for use with laboratory animals. It can detect and record neural signals from the cortical region of the brain during pre-clinical trials. The device utilizes simplified circuitry to perform signal detection, filtering, sampling, and storage. It includes analog and digital components each implemented on a separate small printed circuit board. The two printed circuit boards are then attached to one another to form the device. It is capable of uninterrupted operation for over 2 hours on a single coin battery. A bench-testing of the device was performed with pre-recorded neural signal which then injected to the input of the device to give validation of efficient operation of the device. Its amplification and filtration features have been analyzed. An overall 56 dB amplification and filtration in the frequency range of 300 Hz to 4 KHz was achieved. Sampling and storage at a reduced power and computational load is demonstrated with uninterrupted storage of the neural signal. A comparison of the input and reconstructed neural signals shows minimal variation error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on a six month longitudinal study exploring people’s personal and social emotional experience with Portable Interactive Devices (PIDs). The study is concerned with the experience design approach and based on the theoretical framework of Activity Theory. The focus is on emotional experiences and how artefacts mediate and potentially enhance this experience. The outcomes of the study identified interesting aspects of PID interaction. Findings revealed people interact with PIDs emotionally both at a personal and a social level, supporting previous studies. Further, the social level impacts significantly on the emotional experience attained. If negative social experiences exceeded negative personal experiences the emotional experience was constant over six months. If negative personal experiences surpassed negative social experiences the emotional experience was varied over six months. The findings are discussed in regards to their significance to the field of design, their implication for future PID design and future research directions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on a six month longitudinal study exploring people’s personal and social emotional experience with health related portable interactive devices (PIDs). The focus is on emotions and how health PIDs mediate this experience in everyday contexts. The study reported here is an extension of a previous experiment conducted by the authors exploring media related PIDs [1]. The findings identified interesting aspects of health device interaction. Findings revealed people interact with health PIDs emotionally both at a personal and a social level. However, in contrast to media PIDs, participants reported significantly less social experiences than personal experiences. Nevertheless, the social level plays an important role such that negative social experiences had a significant influence on the perceived emotional experience over the course of six months. When no negative social experiences were reported the emotional experience over the course of six months became neutral. The findings are discussed in regards to their significance to the field of design, their implication for future health PID design and future research directions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this preliminary study was to determine the relevance of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees. The objectives were a) to introduce a categorization of load regime, b) to present some descriptors of each activity, and c) to report the results for a case. The load applied on the osseointegrated fixation of one transfemoral amputee was recorded using a portable kinetic system for 5 hours. The periods of directional locomotion, localized locomotion, and stationary loading occurred 44%, 34%, and 22% of recording time and each accounted for 51%, 38%, and 12% of the duration of the periods of activity, respectively. The absolute maximum force during directional locomotion, localized locomotion, and stationary loading was 19%, 15%, and 8% of the body weight on the anteroposterior axis, 20%, 19%, and 12% on the mediolateral axis, and 121%, 106%, and 99% on the long axis. A total of 2,783 gait cycles were recorded. Approximately 10% more gait cycles and 50% more of the total impulse than conventional analyses were identified. The proposed categorization and apparatus have the potential to complement conventional instruments, particularly for difficult cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on a six month longitudinal study exploring people’s emotional experience with two categories of portable interactive devices (PIDs); media and health related PIDs. The focus is on emotions and how PIDs mediate these experiences in everyday contexts. Previous findings presented by the authors (Gomez 2009, 2010) revealed that people’s emotional experiences with PIDs over time are influenced by whether interactions were at a personal or social level. This paper presents four categories of activities identified and their relationship to emotional experiences with PIDs that have been developed through further analysis of the data. It concludes with a discussion of the findings and their implications to the field of Design on the design of future PIDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raman spectroscopy, when used in spatially offset mode, has become a potential tool for the identification of explosives and other hazardous substances concealed in opaque containers. The molecular fingerprinting capability of Raman spectroscopy makes it an attractive tool for the unambiguous identification of hazardous substances in the field. Additionally, minimal sample preparation is required compared with other techniques. We report a field portable time resolved Raman sensor for the detection of concealed chemical hazards in opaque containers. The new sensor uses a pulsed nanosecond laser source in conjunction with an intensified CCD detector. The new sensor employs a combination of time and space resolved Raman spectroscopy to enhance the detection capability. The new sensor can identify concealed hazards by a single measurement without any chemometric data treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dengue virus is the most significant human viral pathogen spread by the bite of an infected mosquito. With no vaccine or antiviral therapy currently available, disease prevention relies largely on surveillance and mosquito control. Preventing the onset of dengue outbreaks and effective vector management would be considerably enhanced through surveillance of dengue virus prevalence in natural mosquito populations. However, current approaches to the identification of virus in field-caught mosquitoes require relatively slow and labor intensive techniques such as virus isolation or RT-PCR involving specialized facilities and personnel. A rapid and portable method for detecting dengue virus-infected mosquitoes is described. Using a hand held battery operated homogenizer and a dengue diagnostic rapid strip the viral protein NS1 was detected as a marker of dengue virus infection. This method could be performed in less than 30 min in the field, requiring no downstream processing, and is able to detect a single infected mosquito in a pool of at least 50 uninfected mosquitoes. The method described in this study allows rapid, real-time monitoring of dengue virus presence in mosquito populations and could be a useful addition to effective monitoring and vector control responses.