795 resultados para middle ear
Resumo:
Otitis media (OM) (a middle ear infection) is a common childhood illness that can leave some children with permanent hearing loss. OM can arise following infection with a variety of different pathogens, including a coinfection with influenza A virus (IAV) and Streptococcus pneumoniae (the pneumococcus). We and others have demonstrated that coinfection with IAV facilitates the replication of pneumococci in the middle ear. Specifically, we used a mouse model of OM to show that IAV facilitates the outgrowth of S. pneumoniae in the middle ear by inducing middle ear inflammation. Here, we seek to understand how the host inflammatory response facilitates bacterial outgrowth in the middle ear. Using B cell-deficient infant mice, we show that antibodies play a crucial role in facilitating pneumococcal replication. We subsequently show that this is due to antibody-dependent neutrophil extracellular trap (NET) formation in the middle ear, which, instead of clearing the infection, allows the bacteria to replicate. We further demonstrate the importance of these NETs as a potential therapeutic target through the transtympanic administration of a DNase, which effectively reduces the bacterial load in the middle ear. Taken together, these data provide novel insight into how pneumococci are able to replicate in the middle ear cavity and induce disease.
Resumo:
Välikorvaleikkauksiin usein liittyvän välikorvan ja kuuloluuketjun kirurgisen rekonstruktion tavoitteena on luoda olosuhteet, jotka mahdollistavat hyvän kuulon sekä välikorvan säilymisen tulehduksettomana ja ilmapitoisena. Välikorvan rekonstruktiossa on käytetty implanttimateriaaleina perinteisesti potilaan omia kudoksia sekä tarvittaessa erilaisia hajoamattomia biomateriaaleja, mm. titaania ja silikonia. Ongelmana biomateriaalien käytössä voi olla bakteerien adherenssi eli tarttuminen vieraan materiaalin pintaan, mikä saattaa johtaa biofilmin muodostumiseen. Tämä voi aiheuttaa kroonisen, huonosti antibiootteihin reagoivan infektion kudoksessa, mikä usein käytännössä johtaa uusintaleikkaukseen ja implantin poistoon. Maitohappo- ja glykolihappopohjaiset biologisesti hajoavat polymeerit ovat olleet kliinisessä käytössä jo vuosikymmeniä. Niitä on käytetty erityisesti tukimateriaaleina mm. ortopediassa sekä kasvo- ja leukakirurgiassa. Niitä ei ole toistaiseksi käytetty välikorvakirurgiassa. Korvan kuvantamiseen käytetään ensisijaisesti tietokonetomografiaa (TT). TT-tutkimuksen ongelmana on potilaan altistuminen suhteellisen korkealle sädeannokselle, joka kasvaa kumulatiivisesti, jos kuvaus joudutaan toistamaan. Väitöskirjatyö selvittää uuden, aiemmin kliinisessä työssä rutiinisti lähinnä hampaiston ja kasvojen alueen kuvantamiseen käytetyn rajoitetun kartiokeila-TT:n soveltuvuutta korvan alueen kuvantamiseen. Väitöskirjan kahdessa ensimmäisessä osatyössä tutkittiin ja verrattiin kahden kroonisia ja postoperatiivisia korvainfektioita aiheuttavan bakteerin, Staphylococcus aureuksen ja Pseudomonas aeruginosan, in vitro adherenssia titaanin, silikonin ja kahden eri biohajoavan polymeerin (PLGA) pintaan. Lisäksi tutkittiin materiaalien albumiinipinnoituksen vaikutusta adherenssiin. Kolmannessa osatyössä tutkittiin eläinmallissa PLGA:n biokompatibiliteettia eli kudosyhteensopivuutta kokeellisessa välikorvakirurgiassa. Chinchillojen välikorviin istutettiin PLGA-materiaalia, eläimiä seurattiin, ja ne lopetettiin 6 kk:n kuluttua operaatiosta. Biokompatibiliteetin arviointi perustui kliinisiin havaintoihin sekä kudosnäytteisiin. Neljännessä osatyössä tutkittiin kartiokeila-TT:n soveltuvuutta korvan alueen kuvantamiseen vertaamalla sen tarkkuutta perinteisen spiraali-TT:n tarkkuuteen. Molemmilla laitteilla kuvattiin ohimo- eli temporaaliluita korvan alueen kliinisesti ja kirurgisesti tärkeiden rakenteiden kuvantumisen tarkkuuden arvioimiseksi. Viidennessä osatyössä arvioitiin myös operoitujen temporaaliluiden kuvantumista kartiokeila-TT:ssa. Bakteeritutkimuksissa PLGA-materiaalin pintaan tarttui keskimäärin korkeintaan saman verran tai vähemmän bakteereita kuin silikonin tai titaanin. Albumiinipinnoitus vähensi bakteeriadherenssia merkitsevästi kaikilla materiaaleilla. Eläinkokeiden perusteella PLGA todettiin hyvin siedetyksi välikorvassa. Korvakäytävissä tai välikorvissa ei todettu infektioita, tärykalvon perforaatioita tai materiaalin esiin työntymistä. Kudosnäytteissä näkyi lievää tulehdusreaktiota ja fibroosia implantin ympärillä. Temporaaliluutöissä rajoitettu kartiokeila-TT todettiin vähintään yhtä tarkaksi menetelmäksi kuin spiraali-TT välikorvan ja sisäkorvan rakenteiden kuvantamisessa, ja sen aiheuttama kertasäderasitus todettiin spiraali-TT:n vastaavaa huomattavasti vähäisemmäksi. Kartiokeila-TT soveltui hyvin välikorvaimplanttien ja postoperatiivisen korvan kuvantamiseen. Tulokset osoittavat, että PLGA on välikorvakirurgiaan soveltuva, turvallinen ja kudosyhteensopiva biomateriaali. Biomateriaalien pinnoittaminen albumiinilla vähentää merkittävästi bakteeriadherenssia niihin, mikä puoltaa pinnoituksen soveltamista implanttikirurgiassa. Kartiokeila-TT soveltuu korvan alueen kuvantamiseen. Sen tarkkuus kliinisesti tärkeiden rakenteiden osoittamisessa on vähintään yhtä hyvä ja sen potilaalle aiheuttama sädeannos pienempi kuin nykyisen korva-spiraali-TT:n. Tämä tekee menetelmästä spiraali-TT:aa potilasturvallisemman vaihtoehdon erityisesti, jos potilaan tilanne vaatii seurantaa ja useampia kuvauksia, ja jos halutaan kuvata rajoitettuja alueita uni- tai bilateraalisesti.
Resumo:
10 p.
Resumo:
Background: Acute respiratory infections are usual in children under three years old occurring in upper respiratory tract, having an impact on child and caregiver’s quality of life predisposing to otitis media or bronchiolitis. There are few valid and reliable measures to determine the child’s respiratory condition and to guide the physiotherapy intervention. Aim: To assess the intra and inter rater reliability of nasal auscultation, to analyze the relation between sounds’ classification and middle ear’s pressure and compliance as well as with the Clinical Severity Score. Methods: A cross-sectional observational study was composed by 125 nursery children aged up to three years old. Tympanometry, pulmonary and nasal auscultation and application of Clinical Severity Score were performed to each child. Nasal auscultation sounds’ were recorded and sent to 3 blinded experts, that classified, as “obstructed” and “unobstructed”, with a 48 hours interval, in order to analyze inter and intra rater reliability. Results: Nasal auscultation revealed a substantial inter and intra rater reliability (=0,749 and evaluator A - K= 0,691; evaluator B - K= 0,605 and evaluator C - K= 0,724, respectively). Both ears’ pressure was significantly lower in children with an "unobstructed" nasal sound when compared with an “obstructed” nasal sound (t=-3,599, p<0,001 in left ear; t=-2,258, p=0,026 in right ear). Compliance in both ears was significantly lower in children with an "obstructed" nasal sound when compared with “unobstructed” nasal sound (t=-2,728, p=0,007 in left ear; t=-3,830, p<0,001 in right ear). There was a statistically significant association between sounds’ classification and tympanograms types in both ear’s (=11,437, p=0,003 in left ear; =13,535, p=0,001 in right ear). There was a trend to children with an "unobstructed" nasal sound that had a lower clinical severity score when compared with “obstructed” children. Conclusion: It was observed a good intra and substantial inter reliability for nasal auscultation. Nasal auscultation sounds’ classification was related to middle ears’ pressure and compliance.
Resumo:
This paper discusses the use of tympanometric gradient, middle ear resonance and static admittance as diagnostic tools for testing the hearing of children and infants.
Resumo:
This paper is a review of a study to determine whether the use of otoscopic examination and middle ear impedance measurement are feasible tools for use by an audiologist during a screening program.
Resumo:
Hypothesis: The aim of this study was to measure the mass loading effect of an active middle-ear implant (the Vibrant Soundbridge) in cadaver temporal bones. Background: Implantable middle ear hearing devices such as Vibrant Soundbridge have been used as an alternative to conventional hearing aids for the rehabilitation of sensorineural hearing loss. Other than the obvious disadvantage of requiring implantation middle ear surgery, it also applies a direct weight on the ossicular chain which, in turn, may have an impact on residual hearing. Previous studies have shown that applying a mass directly on the ossicular chain has a damping effect on its response to sound. However, little has been done to investigate the magnitude and the frequency characteristics of the mass loading effect in devices such as the Vibrant Soundbridge. Methods: Five fresh cadaver temporal bones were used. The stapes displacement was measured using laser Doppler vibrometry before and after the placement of a Vibrant Sound-bridge floating mass transducer. The effects of mass and attachment site were compared with the unloaded response. Measurements were obtained at frequencies between 0.1 and 10 kHz and at acoustic input levels of 100 dB sound pressure level. Each temporal bone acted as its own control. Results: Placement of the floating mass transducer caused a reduction of the stapes displacement. There were variations between the bones. The change of the stapes displacement varied from 0 dB to 28 dB. The effect was more prominent at frequencies above 1,000 Hz. Placing the floating mass transducer close to the incudostapedial joint reduced the mass loading effect. Conclusion: The floating mass transducer produces a measurable reduction of the stapes displacement in the temporal bone model. The effect is more prominent at high frequencies.
Resumo:
Objective: The present study aimed at evaluating the occurrence and recurrence of middle ear effusion and possible associated factors in the first two years of life of 190 newborns and infants, participants in the interdisciplinary prevention, detection, and intervention program at the Clínica de Educação para Saúde of Universidade do Sagrado Coração, Methods: Newborns and infants were monthly submitted to anamneses, otoscopy, behavioral hearing assessment using sound instruments and pure tones (pediatric audiometry) and tympanometry. Results: The results revealed that 68.4% of infants presented one or more episodes of middle ear effusion during their two first years, with more recurrence among males. Peak occurrence was between four and 12 months of age and, the earlier the first episode, the higher the probability of recurrence. Greatest incidence was during May and August. It was found that, of the variables investigated, the period of exclusive breastfeeding actuated as a protector factor. With respect of risk factors, it was observed that passive smoking, gastro-esophageal reflux and respiratory allergy were related with the recurrences of effusion. Conclusion: Findings revealed the importance of periodic auditory follow-up for infants during their first two years of life, considered to be the critical period of auditory system maturation, during which sensory deprivation can be responsible for damage to the development of speech, language and other auditory abilities. Copyright © 2005 by Sociedade Brasileira de Pediatria.
Resumo:
Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.
Resumo:
Thiel-embalmed human whole head specimens represent an alternative model in middle ear research.
Resumo:
OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.
Resumo:
A life-size mechanical middle ear model and human temporal bones were used to evaluate three different middle ear transducers for implantable hearing aids: the driving rod transducer (DRT), the floating mass transducer (FMT) or vibrant sound bridge, and the contactless transducer (CLT). Results of the experiments with the mechanical model were within the range of the results for human temporal bones. However, results with the mechanical model showed better reproducibility. The handling of the mechanical model was considerably simpler and less time-consuming. Systematic variations of mounting parameters showed that the angle of the rod has virtually no effect on the output of the DRT, the mass loading on the cable of the FMT has a larger impact on the output than does the tightness of crimping, and the output level of the CLT can be increased by 10 dB by optimizing the mounting parameters.
Resumo:
This paper presents a case of a 28-year-old male with a seizure episode and a 4-year history of intermittent tinnitus on the left ear. On computed tomography and magnetic resonance imaging, a density with rim enhancement was found at the temporal lobe, associated with mastoid tegmen destruction and middle ear mass, indicating cholesteatoma with complicating brain abscess. Evacuation of the brain abscess was performed with a combined otolaryngologic and neurosurgical procedures (canal wall-down mastoidectomy and temporal craniotomy). The pathology turned out to be infestation with Echinococcus granulosus.