81 resultados para microtomography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray microtomography has become a new tool in earth sciences to obtain non-destructive 3D-image data from geological objects in which variations in mineralogy, chemical composition and/or porosity create sufficient x-ray density contrasts.We present here first, preliminary results of an application to the external and internal morphology of Permian to Recent Larger Foraminifera. We use a SkyScan-1072 high-resolution desk-top micro-CT system. The system has a conical x-ray source with a spot size of about 5µm that runs at 20-100kV, 0-250µA, resulting in a maximal resolution of 5µm. X-ray transmission images are captured by a scintillator coupled via fibre optics to a 1024x1024 pixel 12-bit CCD. The object is placed between the x-ray source and the scintillator on a stub that rotates 360°around its vertical axis in steps as small as 0.24 degrees. Sample size is limited to 2 cm due to the absorption of geologic material for x-rays. The transmission images are back projected using a Feldkamp algorithm into a vertical stack of up to 1000 1Kx1K images that represent horizontal cuts of the object. This calculation takes 2 to several hours on a Double-Processor 2.4GHz PC. The stack of images (.bmp) can be visualized with any 3D-imaging software, used to produce cuts of Larger Foraminifera. Among other applications, the 3D-imaging software furnished by SkyScan can produce 3D-models by defining a threshold density value to distinguish "solid" from "void. Several models with variable threshold values and colors can be imbricated, rotated and cut together. The best results were obtained with microfossils devoid of chamber-filling cements (Permian, Eocene, Recent). However, even slight differences in cement mineralogy/composition can result in surprisingly good x-ray density contrasts.X-ray microtomography may develop into a powerful tool for larger microfossils with a complex internal structure, because it is non-destructive, requires no preparation of the specimens, and produces a true 3D-image data set. We will use these data sets in the future to produce cuts in any direction to compare them with arbitrary cuts of complex microfossils in thin sections. Many groups of benthic and planktonic foraminifera may become more easily determinable in thin section by this way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of the soil pore system represents an important way of characterizing soil structure. Properties such as the shape and number of pores can be determined through soil pore evaluations. This study presents a three-dimensional (3D) characterization of the shape and number of pores of a sub-tropical soil. To do so, a second generation X-ray microtomograph equipped with a plain type detector was employed. A voltage of 120 kV and current of 80 mA was applied to the X-ray tube. The soil samples analyzed were collected at three different depths (0-10, 10-20, and 20-30 cm). The results obtained allowed qualitative (images) and quantitative (3D) analyses of the soil structure, revealing the potential of the microtomographic technique, as well as the study of differences in soil macroporosity at different depths. Macroporosity was 5.14 % in the 0-10 cm layer, 5.10 % in the 10-20 cm layer, and 6.64 % in the 20-30 cm layer. The macroporosity of unclassified pores (UN) was 0.30 % (0-10 and 10-20 cm) and 0.40 % (20-30 cm), while equant pores (EQ) had values of 0.01 % at the three depths under analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Root characteristics of seedlings of five different barley genotypes were analysed in 2D using gel chambers, and in 3D using soil sacs that were destructively harvested and pots of soil that were assessed non-invasively using X-ray microtomography. After 5 days, Chime produced the greatest number of root axes (similar to 6) and Mehola significantly less (similar to 4) in all growing methods. Total root length was longest in GSH01915 and shortest in Mehola for all methods, but both total length and average root diameter were significantly larger for plants grown in gel chambers than those grown in soil. The ranking of particular growth traits (root number, root angular spread) of plants grown in gel plates, soil sacs and X-ray pots was similar, but plants grown in the gel chambers had a different order of ranking for root length to the soil-grown plants. Analysis of angles in soil-grown plants showed that Tadmore had the most even spread of individual roots and Chime had a propensity for non-uniform distribution and root clumping. The roots of Mehola were less well spread than the barley cultivars supporting the suggestion that wild and landrace barleys tend to have a narrower angular spread than modern cultivars. The three dimensional analysis of root systems carried out in this study provides insights into the limitations of screening methods for root traits and useful data for modelling root architecture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. In contrast to above-ground insects, comparatively little is known about the behaviour of subterranean insects, due largely to the difficulty of studying them in situ. 2. The movement of newly hatched (neonate) clover root weevil (Sitona lepidus L. Coleoptera: Curculinidae) larvae was studied non-invasively using recently developed high resolution X-ray microtomography. 3. The movement and final position of S. lepidus larvae in the soil was reliably established using X-ray microtomography, when compared with larval positions that were determined by destructively sectioning the soil column. 4. Newly hatched S. lepidus larvae were seen to attack the root rhizobial nodules of their host plant, white clover (Trifolium repens L.). Sitona lepidus larvae travelled between 9 and 27 mm in 9 h at a mean speed of 1.8 mm h(-1). 5. Sitona lepidus larvae did not move through the soil in a linear manner, but changed trajectory in both the lateral and vertical planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the use of a collagen-based membrane compared with no treatment on guided bone regeneration by 3-dimensional computerized microtomography (mu CT).Study Design. Defects were created between the mesial and distal premolar roots of the second and third premolars (beagle dogs; n = 8). A collagen-based membrane (Vitala; Osteogenics Biomedical Inc., TX, USA) was placed in one of the defects (membrane group; n = 16), and the other was left untreated (no-membrane group; n = 16). Left and right sides provided healing samples for 2 and 16 weeks. Three-dimensional bone architecture was acquired by mu CT and categorized as fully regenerated (F, bone height and width) or nonregenerated (N).Results. Chi-square tests (95% level of significance) showed that tooth did not have an effect on outcome (P = .5). Significantly higher F outcomes were observed at 16 weeks than 2 weeks (P = .008) and in membrane group than in no-membrane group (P = .008).Conclusions. The collagen-based membrane influenced bone regeneration at the furcation. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:437-443)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates laboratory microtomography and microhardness analysis for quantifying the mineral content of bovine enamel. Fifty enamel blocks were submitted individually for 5 days to a pH-cycling model at 37 degrees C and remained in the remineralizing solution for 2 days. The blocks were treated twice daily for 1 min with NaF dentifrices (Placebo, 275, 550, 1,100 mu g F/g and Crest (R)) diluted in deionized water. Surface microhardness changes (%SMH) and mineral loss (Delta Z) were then calculated. Laboratory microtomography was also used to measure total mineral lost (LMM). Pearson's correlation (p < 0.05) was used to determine the relationship between different methods of analysis and dose-response between treatments. Dentifrice fluoride concentration and %SMH and Delta Z were correlated (p < 0.05). There was a positive relationship (p < 0.05) when comparing LMM vs. Delta Z; a negative relationship (p < 0.05) was found for %SMH vs. LMM and %SMH vs. Delta Z. Therefore, both mineral quantification techniques provide adequate precision for studying the bovine enamel-pH-cycling demineralization/remineralization model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synchrotron microtomography is a tool to quantify the mineralization of dental tissues as well as microhardness analysis, since they provide adequate precision and contrast sensitivity. This study evaluates synchrotron microtomography and microhardness analysis for quantifying the mineral content of bovine enamel. Fifty enamel blocks were submitted individually for 5 days to a pH-cycling model at 37 degrees C and remained in the remineralizing solution for 2 days. The blocks were treated twice daily for 1 min with NaF dentifrices (Placebo, 275, 550, 1,100 mu g F/g and Crest (R)) diluted in deionized water. Surface microhardness changes (%SMH) and mineral loss (Delta Z) were then calculated. Synchrotron microtomography was also used to measure total mineral lost (SMM). Pearson's correlation (p < 0.05) was used to determine the relationship between different methods of analysis and dose-response between treatments. Dentifrice fluoride concentration and %SMH and Delta Z were correlated (p < 0.05). There was a positive relationship (p < 0.05) when comparing SMM vs. Delta Z; a negative relationship (p < 0.05) was found for %SMH vs. SMM and %SMH vs. Delta Z. Based on the results of this study, it was possible to conclude that synchrotron microtomography provides the best spatial resolution and contrast sensitivity for quantifying mineral gradients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the anticaries potential of pit and fissure sealants containing amorphous calcium phosphate (ACP) by synchrotron microtomography. Bovine enamel blocks (4x4 mm; n=50) were selected through surface hardness (Knoop) analysis. Slabs were obtained through cross-sections taken 1 mm from the border of the enamel. Five indentations, spaced 100 mu m apart, were made 300 mu m from the border. Ten specimens were prepared for each tested material (Ultraseal XT plus TM, Aegis, Embrace, Vitremer and Experimental Sealant). The materials were randomly attached to the sectioned surfaces of the enamel blocks and fixed with sticky wax. The specimens were submitted to pH cycling. After that, the surface hardness (SH1) was determined, and the blocks were submitted to synchrotron microcomputed tomography analysis to calculate the mineral concentration (Delta g(HAp) cm(-3)) at different areas of the enamel. The comparison between the SH1 and DgHAp cm(-3) showed a correlation for all groups (r=0.840; p<0.001). The fluoride groups presented positive values of DgHAp cm(-3), indicating a mineral gain that was observed mainly in the outer part of the enamel. The ACP showed mineral loss in the outer enamel compared with fluoride groups, although it inhibited the demineralization in the deeper areas of enamel. The combination of two remineralizing agents (fluoride and ACP) was highly effective in preventing demineralization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Food restriction reduces body weight and influence bone mass and also is correlated with bone mineral density (BMD). Mechanisms have been proposed for the loss of BMD after body weight reduction, including reduced energy intake. Growing 8 wk-old Wistar male rats were randomly divided into Control and Calorie restriction associated with sucrose 30% (CRS). These animals were subjected to intermittent food restriction during 8 weeks and had free access to tap water and sucrose30% in distilled water. The rats were euthanized at the end of week 8, blood collected from abdominal aorta artery, femurs cleaned of adherent soft tissues, scanned using dual energy X-ray absorptiometry, structural and material properties determined by three-point bending testing in the mid-diaphyseal region, bone surface tested in a microhardness tester and microstructure was assessed in a microcomputer tomography. In CRS animals body weight decreased significantly relative to the Control animals. There was a clear option for high-sucrose beverage in CRS animals. No difference was observed in biochemical, densitometric and biomechanical analyzes. Results from micro CT showed only significant difference in connectivity of trabecular bone. It has been suggested that rats submitted to food restriction consumed sugar not because of its inherent palatability, but in order to alter their macronutrient balance and animals need to meet energy demands in high-sucrose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new version of the TomoRebuild data reduction software package is presented, for the reconstruction of scanning transmission ion microscopy tomography (STIMT) and particle induced X-ray emission tomography (PIXET) images. First, we present a state of the art of the reconstruction codes available for ion beam microtomography. The algorithm proposed here brings several advantages. It is a portable, multi-platform code, designed in C++ with well-separated classes for easier use and evolution. Data reduction is separated in different steps and the intermediate results may be checked if necessary. Although no additional graphic library or numerical tool is required to run the program as a command line, a user friendly interface was designed in Java, as an ImageJ plugin. All experimental and reconstruction parameters may be entered either through this plugin or directly in text format files. A simple standard format is proposed for the input of experimental data. Optional graphic applications using the ROOT interface may be used separately to display and fit energy spectra. Regarding the reconstruction process, the filtered backprojection (FBP) algorithm, already present in the previous version of the code, was optimized so that it is about 10 times as fast. In addition, Maximum Likelihood Expectation Maximization (MLEM) and its accelerated version Ordered Subsets Expectation Maximization (OSEM) algorithms were implemented. A detailed user guide in English is available. A reconstruction example of experimental data from a biological sample is given. It shows the capability of the code to reduce noise in the sinograms and to deal with incomplete data, which puts a new perspective on tomography using low number of projections or limited angle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D woven composites reinforced with either S2 glass, carbon or a hybrid combination of both and containing either polyethylene or carbon z-yarns were tested under low-velocity impact. Different impact energies (in the range of 21–316 J) were used and the mechanical response (in terms of the impact strength and energy dissipated) was compared with that measured in high-performance, albeit standard, 2D laminates. It was found that the impact strength in both 2D and 3D materials was mainly dependent on the in-plane fiber fracture. Conversely, the energy absorption capability was primarily influenced by the presence of z-yarns, having the 3D composites dissipated over twice the energy than the 2D laminates, irrespective of their individual characteristics (fiber type, compaction degree, porosity, etc.). X-ray microtomography revealed that this improvement was due to the z-yarns, which delayed delamination and maintained the structural integrity of the laminate, promoting energy dissipation by tow splitting, intensive fiber breakage under the tup and formation of a plug by out-of-plane shear.