65 resultados para microbicide


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The poly (l-lysine)-based SPL7013 dendrimer with naphthalene disulphonate surface groups blocks the entry of HIV-1 into target cells and is in clinical trials for development as a topical microbicide. Its mechanism of action against R5 HIV-1, the HIV-1 variant implicated in transmission across individuals, remains poorly understood. Using docking and fully atomistic MD simulations, we find that SPL7013 binds tightly to R5 gp120 in the gp120-CD4 complex but weakly to gp120 alone. Further, the binding, although to multiple regions of gp120, does not occlude the CD4 binding site on gp120, suggesting that SPL7013 does not prevent the binding of R5 gp120 to CD4. Using MD simulations to compute binding energies of several docked structures, we find that SPL7013 binding to gp120 significantly weakens the gp120-CD4 complex. Finally, we use steered molecular dynamics (SMD) to study the kinetics of the dissociation of the gp120-CD4 complex in the absence of the dendrimer and with the dendrimer bound in each of the several stable configurations to gp120. We find that SPL7013 significantly lowers the force required to rupture the gp120-CD4 complex and accelerates its dissociation. Taken together, our findings suggest that SPL7013 compromises the stability of the R5 gp120-CD4 complex, potentially preventing the accrual of the requisite number of gp120-CD4 complexes across the virus-cell interface, thereby blocking virus entry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vaginal microbicides for the prevention of HIV transmission may be an important option for protecting women from infection. Incorporation of dapivirine, a lead candidate nonnucleoside reverse transcriptase inhibitor, into intravaginal rings (IVRs) for sustained mucosal delivery may increase microbicide product adherence and efficacy compared with conventional vaginal formulations. Twentyfour
healthy HIV-negative women 18–35 years of age were randomly assigned (1:1:1) to dapivirine matrix IVR, dapivirine reservoir IVR, or placebo IVR. Dapivirine concentrations were measured in plasma
and vaginal fluid samples collected at sequential time points over the 33-day study period (28 days of IVR use, 5 days of follow-up). Safety was assessed by pelvic/colposcopic examinations, clinical laboratory tests, and adverse events. Both IVR types were safe and well tolerated with similar adverse events observed in the placebo and dapivirine groups. Dapivirine from both IVR types was successfully distributed throughout the lower genital tract at concentrations over 4 logs greater than the EC50 against wild-type HIV-1 (LAI) in MT4 cells. Maximum concentration (Cmax) and area under the concentration–time curve (AUC) values were significantly higher with the matrix than reservoir IVR. Mean plasma concentrations of dapivirine were ,2 ng/mL. These findings suggest that IVR delivery of microbicides is a viable option meriting further study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: HIV microbicide trials have emphasized the need to evaluate the safety of topical microbicides and delivery platforms in an animal model prior to conducting clinical efficacy trials. An ideal delivery device should provide sustainable and sufficient concentrations of effective products to prevent HIV transmission while not increasing transmission risk by either local mucosal inflammation and/or disruption of the normal vaginal microflora.

METHODS: Safety analyses of macaque-sized elastomeric silicone and polyurethane intravaginal rings (IVRs) loaded with candidate antiretroviral (ARV) drugs were tested in four studies ranging in duration from 49 to 73 days with retention of the IVR being 28 days in each study. Macaques were assigned to 3 groups; blank IVR, ARV-loaded IVR, and naïve. In sequential studies, the same macaques were used but rotated into different groups. Mucosal and systemic levels of cytokines were measured from vaginal fluids and plasma, respectively, using multiplex technology. Changes in vaginal microflora were also monitored. Statistical analysis (Mann-Whitney test) was used to compare data between two groups of unpaired samples (with and without IVR, and IVR with and without ARV) for the groups collectively, and also for individual macaques.

RESULTS: There were few statistically significant differences in mucosal and systemic cytokine levels measured longitudinally when the ring was present or absent, with or without ARVs. Of the 8 proinflammatory cytokines assayed a significant increase (p = 0.015) was only observed for IL8 in plasma with the blank and ARV loaded IVR (median of 9.2 vs. 5.7 pg/ml in the absence of IVR). There were no significant differences in the prevalence of H2O2-producing lactobacilli or viridans streptococci, or other microorganisms indicative of healthy vaginal microflora. However, there was an increase in the number of anaerobic gram negative rods in the presence of the IVR (p= < 0.0001).

CONCLUSIONS: IVRs with or without ARVs neither significantly induce the majority of potentially harmful proinflammatory cytokines locally or systemically, nor alter the lactobacillus or G. vaginalis levels. The increase in anaerobic gram negative rods alone suggests minimal disruption of normal vaginal microflora. The use of IVRs as a long-term sustained delivery device for ARVs is promising and preclinical studies to demonstrate the prevention of transmission in the HIV/SHIV nonhuman primate model should continue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

UC781 is a potent and poorly water-soluble nonnucleoside reverse transcriptase inhibitor being investi- gated as a potential microbicide for preventing sexual transmission of HIV-1. This study was designed to evaluate the in vivo release and pharmacokinetics of UC781 delivered from matrix-type intravaginal ring segments in rabbits. Three polymer matrices (polyurethane, ethylene vinyl acetate copolymer, and silicone elastomer) and two drug loadings (5 and 15 mg/segment) were evaluated in at least one of two independent studies for up to 28 days in vivo. Inter-study comparison of in vivo release, vaginal tissue, and plasma concentrations for similar formulations demonstrated good reproducibility of the animal model. Mean estimates for a 28-day in vivo release ranged from 0.35 to 3.17 mg UC781 per segment. Mean proximal vaginal tissue levels (adjacent to the IVR segment) were 8– 410 ng/g and did not change significantly with time for most formulations. Distal vaginal tissue levels of UC781 were 6- to 49-fold lower than proximal tissue levels. Mean UC781 plasma levels were low for all formulations, at 0.09–0.58 ng/mL. All formulations resulted in similar UC781 concentrations in vaginal tissue and plasma, except the low loading polyurethane group which provided significantly lower levels. Loading dependent release and pharmacokinetics were only clearly observed for the polyurethane matrix. Based on these results, intravaginal ring segments loaded with UC781 led to vaginal tissue concen- trations ranging from below to approximately two orders of magnitude higher than UC781’s EC50 under in vitro conditions (2.8 ng/mL), with little influence by polymer matrix or UC781 loading. Moreover, these findings support the use of rabbit vaginal pharmacokinetic studies in preclinical testing of microbicide intravaginal rings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an urgent global need for preventative strategies against HIV-1 infections. Llama heavy-chain antibody fragments (VHH) are a class of molecules recently described as potent cross-clade HIV-1 entry inhibitors. We studied the potential of a VHH-based microbicide in an application-oriented fashion. We show that VHH can be inexpensively produced in high amounts in the GRAS organism S. cerevisiae, resulting in very pure, and endotoxin free product. VHH are very stable under conditions they might encounter during transport, storage or use by women. We developed active formulations of VHH in aqueous gel and compressed and lyophilized tablets for controlled release from an intra vaginal device. The release profile of the VHH from e.g. a vaginal ring suggests sufficient bioavailability and protective concentration of the molecule at the mucosal site at the moment of the infection. The ex vivo penetration kinetics through human tissues show that the VHH diffuse into the mucosal layer and open the possibility to create a second defense layer either by blocking the HIV receptor binding sites or by blocking the receptors of immune cells in the mucosa. In conclusion, our data show that VHH have

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antiretroviral entry inhibitors are now being considered as vaginally administered microbicide candidates for prevention of sexual transmission of human immunodeficiency virus. Previous studies testing the entry inhibitors maraviroc and CMPD167 in aqueous gel formulations showed efficacy in the macaque challenge model, although protection was highly dependent on the time period between initial gel application and subsequent challenge. In this paper, we describe the sustained release of the entry inhibitors maraviroc and CMPD167 from matrix-type silicone elastomer vaginal rings both in vitro and in vivo. Both inhibitors were released continuously over 28 days from rings in vitro, at rates of 100-2500 µg/day. In 28-day pharmacokinetic studies in rhesus macaques, the compounds were measured in the vaginal fluid and vaginal tissue; steady state fluid concentrations were ~106 fold greater than IC50 values for SHIV-162P3 inhibition in macaque lymphocytes in vitro. Plasma concentrations for both compounds were very low. Pretreatment of macaques with Depo-Provera® (DP), as commonly used in macaque challenge studies, was shown to significantly modify the bio-distribution of the inhibitors, but not the overall amount released. Vaginal fluid and tissue concentrations were significantly decreased while plasma levels increased with DP pretreatment. These observations have implications for designing macaque challenge experiments, and also for ring performance during the human female menstrual cycle. Copyright © 2012, American Society for Microbiology. All Rights Reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To investigate the pharmacokinetics (PK) of maraviroc, a CCR5-targeted HIV-1 entry inhibitor, in rhesus macaques following vaginal administration of various maraviroc-loaded aqueous hydroxyethylcellulose (HEC) gels, and to correlate the PK data with efficacy in a single high-dose vaginal SHIV-162P3 challenge model.

Methods: Maraviroc concentrations in vaginal fluid (Weck-Cel® sponge), vaginal tissue (punch biopsy) and plasma were assessed over 72 h following single dose vaginal application of various maraviroc-loaded HEC gels. The range of maraviroc gel concentrations was sufficiently broad (0.003 – 3.3% w/w) such that test gels included both fully solubilised and predominantly dispersed formulations. The efficacy of the HEC gels against a single high dose vaginal SHIV-162P3 challenge was also measured, and correlated with the PK concentrations.

Results: Maraviroc concentrations in vaginal fluid (range 104 – 107 ng/mL), vaginal tissue (100-1200 ng/g) and plasma (< 102 ng/mL) were highly dependent on maraviroc gel loading, irrespective of the form of the maraviroc component within the gel (solubilised vs. dispersed). Fluid and plasma concentrations were generally highest 0.5 or 2 h after gel application, before declining steadily out to 72 h. Maraviroc concentrations in the various biological compartments correlated strongly with the extent of protection against vaginal SHIV-162P3 challenge. Complete protection was achieved with a 3.3% w/w maraviroc gel.

Conclusions: A high degree of correlation between PK and efficacy was observed. Based on the data obtained with the 3.3% w/w maraviroc gel, maintenance of vaginal fluid and tissue levels in the order of 107 ng/mL and 103 ng/g, respectively, are required for complete protection with this compound.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Following the successful development of long-acting steroid-releasing vaginal ring devices for treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing. © 2012 Malcolm et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vaginal rings are currently being developed for the long-term (at least 30 days) continuous delivery of microbicides against human immunodeficiency virus (HIV). Research to date has mostly focused on devices containing a single antiretroviral compound, exemplified by the 25 mg dapivirine ring currently being evaluated in a Phase III clinical study. However, there is a strong clinical rationale for combining antiretrovirals with different mechanisms of action in a bid to increase breadth of protection and limit the emergence of resistant strains. Here we report the development of a combination antiretroviral silicone elastomer matrix-type vaginal ring for simultaneous controlled release of dapivirine, a non-nucleoside reverse transcriptase inhibitor, and maraviroc, a CCR5-targeted HIV-1 entry inhibitor. Vaginal rings loaded with 25 mg dapivirine and various quantities of maraviroc (50– 400 mg) were manufactured and in vitro release assessed. The 25 mg dapivirine and 100 mg maraviroc formulation was selected for further study. A 24-month pharmaceutical stability evaluation was conducted, indicating good product stability in terms of in vitro release, content assay, mechanical properties and related substances. This combination ring product has now progressed to Phase I clinical testing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study measured and compared the pharmacokinetics of CMPD167, a small molecule antiretro- viral CCR5 inhibitor with potential as an HIV microbicide, following vaginal, rectal and oral administration in rhe- sus macaques.
Methods: A vaginal hydroxyethylcellulose (HEC) gel, a rectal HEC gel, a silicone elastomer matrix-type vaginal ring and an oral solution, each containing CMPD167, were prepared and administered to rhesus macaques pretreated with Depo-Provera. CMPD167 concentrations in vaginal fluid, vaginal tissue (ring only), rectal fluid and blood plasma were quantified by HPLC–mass spectrometry.
Results: CMPD167 concentrations measured in rectal fluid, vaginal fluid and blood plasma were highly depend- ent on both the route of administration and the formulation type. Although rectal and vaginal fluid concentra- tions were highest when CMPD167 was administered locally (via either gel or ring), lower concentrations of the drug were also measured in these compartments following administration at the remote mucosal site or orally. CMPD167 levels in the vaginal and rectal fluid following oral administration were relatively low compared with local administration.
Conclusions: The study provides clear evidence for vaginal – rectal and rectal – vaginal drug transfer pathways and suggests that oral pre-exposure prophylaxis with CMPD167 may be less efficacious at preventing sexual trans- mission of HIV-1 than topically applied products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multi-purpose prevention technologies (MPTs) that aim to simultaneously prevent unintended pregnancy, human immunodeficiency virus type 1 (HIV-1) infection and other sexually transmitted infections (STIs) are among the most innovative and complex products currently in development within women’s sexual and reproductive healthcare. In this review article, MPTs are placed within the wider context of combination products, combination drug products and multi-indication products. The current MPT product landscape is mapped and assessed with reference to existing products for the corresponding single indications, before identifying the gaps in the current MPT product pipeline and highlighting priority products and challenges moving forward.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Vaginal ring devices are being actively developed for controlled delivery of HIV microbicides and as multi-purpose prevention technology (MPT) products combining hormonal contraception with prevention of HIV and other sexually transmitted diseases. Presently, there is no reliable method for monitoring user adherence in HIV vaginal ring trials; previous acceptability studies have included some type of participant self-reporting mechanism, which have often been unreliable. More objective, quantitative and accurate methods for assessing adherence are needed.
Methods: A silicone elastomer vaginal ring containing an encapsulated miniature temperature recording device has been developed that can capture and store real-time temperature data during the period of designated use. Devices were tested in both simulated vaginal environments and following vaginal placement in cynomolgus macaques. Various use protocols and data sampling rates were tested to simulate typical patient usage scenarios. Results: The temperature logging devices accurately recorded vaginal temperature in macaques, clearly showing the regular diurnal temperature cycle. When environmental temperature and vaginal temperature was significantly different, the device was able to accurately pinpoint the insertion and removal times. Based on the data collected it was possible to infer removal periods as short as 5 min when the external environmental temperature was 25 °C. Accuracy increased with data sampling rate. Conclusions: This work provides proof-of-concept for monitoring adherence using a vaginal ring device containing an encapsulated temperature logger. The addition of one or more active agents into the ring body is not anticipated to affect the temperature monitoring function. A clinical study to compare self- reported user adherence data with that obtained by the device would be highly informative.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Combination drug products can display thermal behaviour that is more complex than for the corresponding single drug products. For example, the contraceptive vaginal ring (VR) Nuvaring contains a eutectic (lowest melting) composition of etonogestrel (ETN) and ethinyl estradiol. Here we report the predisposition of dapivirine (DPV) to form reduced melting/eutectic mixtures when combined with other contraceptive hormones and antiretrovirals, and discuss the implications for development of combination microbicide and multipurpose prevention technology (MPT) products.
Methods: Binary mixtures of DPV with darunavir (DRV), levonorgestrel (LNG), ETN or maraviroc (MVC) were prepared either by physical mixing or by solvent evaporation. Selected binary mixtures were also incorporated into silicone elastomer (SE) VR devices. Thermal behavior of the mixtures was analyzed using differential scanning calorimetry (DSC) operating in standard heating ramp mode (10 °C/min). DSC data were used to construct two component phase diagrams for each binary system.
Results: Drug mixtures typically showed reduced melting transitions for both drug components, with clear evidence for a eutectic mixture at a well-defined intermediate composition. Eutectic temperatures and compositions for the various mixtures were: 40% DPV / 60% ETN - 170°C; 25% DPV / 75% MVC - 172°C; 65% DPV / 35% LNG - 192°C. In each case, the eutectic composition was also detected when the drug mixtures were incorporated into SE VRs. For the DPV/DRV system, the thermal behaviour is complicated by desolvation from the darunavir ethanolate polymorph.
Conclusions: When DPV is combined with small molecular weight hydrophobic drugs, the melting temperature for both drugs is typically reduced to a degree dependent on the composition of the mixture. At specified compositions, a low melting eutectic system results. The formation of eutectic behavior in binary drug systems needs to be carefully characterised in order to define product performance and drug release.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Combination microbicide vaginal rings, containing two or more antiretrovirals targeting different steps in the HIV replicative process, may be more effective than single microbicide products at preventing sexual transmission of HIV. Here, we report the preclinical development, including in vitro release and macaque pharmacokinetics, of matrix-type silicone elastomer rings containing dapivirine (DPV; an experimental non-nucleoside reverse transcriptase inhibitor) and darunavir (DRV; a marketed protease inhibitor). Methods: Macaque rings containing 25 mg DPV, 300 mg DRV and 100 mg DPV, and 300 mg DRV were manufactured and characterised by differential scanning calorimetry. In vitro release was assessed into isopropanol/water and simulated vaginal fluid. Macaque vaginal fluid and blood serum concentrations for both antiretrovirals were measured during 28-day ring use. Tissue levels were measured on day 28. Ex vivo challenge studies were performed on vaginal fluid samples and IC50 values calculated.
Results: DRV caused a concentration-dependent reduction in the DPV melting temperature in both solid drug mixes and in the combination ring. In vitro release from rings was dependent on drug loading, the number of drugs present, and the release medium. In macaques, serum concentrations of both
microbicides were maintained between 101-102 pg/mL. Vaginal fluid levels
ranged between 103-104 ng/g and 104-105 ng/g for DPV and DRV, respectively. Vaginal tissue concentrations decreased in rank order: vagina
(1.8×103-3.8×103 ng/g) > cervix (9.4×101-3.9×102 ng/g) > uterus (0-108 ng/g) > rectum (0-40 ng/g). Measured IC50 values (HIV-1 BaL) determined from macaque vaginal fluid samples were < 2 ng/mL for both compounds. Conclusions: Based on these results, and in light of the ongoing clinical progress of the 25mg DPV ring, a combination vaginal ring containing DPV and DRV is a viable second-generation HIV microbicide candidate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes the preclinical development of a matrix-type silicone elastomer vaginal ring device designed to provide controlled release of UC781, a non-nucleoside re- verse transcriptase inhibitor. Testing of both human- and macaque-sized rings in a sink condition in vitro release model demonstrated continuous UC781 release in quantities consid- ered sufficient to maintain vaginal fluid concentrations at levels 82–860-fold higher than the in vitro IC50 (2.0 to 10.4 nM) and therefore potentially protect against mucosal trans- mission of HIV. The 100-mg UC781 rings were well tolerated in pig-tailed macaques, did not induce local inflammation as determined by cytokine analysis and maintained median con- centrations in vaginal fluids of UC781 in the range of 0.27 to 5.18 mM during the course of the 28-day study. Analysis of residual UC781 content in rings after completion of both the in vitro release and macaque pharmacokinetic studies revealed that 57 and 5 mg of UC781 was released, respectively. The pharmacokinetic analysis of a 100-mg UC781 vaginal ring in pig-tailed macaques showed poor in vivo–in vitro correlation, attributed to the very poor solubility of UC781 in vaginal fluid and resulting in a dissolution-controlled drug release mecha- nism rather than the expected diffusion-controlled mechanism.