938 resultados para methods of resolution enhancement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The FTIR spectroscopy has been used to quantify the secondary structures of proteins, using amide I band (1600 - 1700 cm-1). The resolution enhancement methods have been used to resolve the individual components of this band that correlate to the secondary structure. In this paper we discuss the methods of derivative, Fourier deconvolution and fitting with simulated spectra. The results shows that they have serious problems and can be used only as a qualitative or semiquatitative method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in Fourier-space. A comparison of 2D and 3D experimental data analysed with subtractive imaging, the equivalent Fourier-space processing of the confocal data only, and Fourier-space weighted averaging is presented. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pursuit of high response rates to minimise the threat of nonresponse bias continues to dominate decisions about resource allocation in survey research. Yet a growing body of research has begun to question this practice. In this study, we use previously unavailable data from a new sampling frame based on population registers to assess the value of different methods designed to increase response rates on the European Social Survey in Switzerland. Using sampling data provides information about both respondents and nonrespondents, making it possible to examine how changes in response rates resulting from the use of different fieldwork methods relate to changes in the composition and representativeness of the responding sample. We compute an R-indicator to assess representativity with respect to the sampling register variables, and find little improvement in the sample composition as response rates increase. We then examine the impact of response rate increases on the risk of nonresponse bias based on Maximal Absolute Bias (MAB), and coefficients of variation between subgroup response rates, alongside the associated costs of different types of fieldwork effort. The results show that increases in response rate help to reduce MAB, while only small but important improvements to sample representativity are gained by varying the type of effort. These findings lend further support to research that has called into question the value of extensive investment in procedures aimed at reaching response rate targets and the need for more tailored fieldwork strategies aimed both at reducing survey costs and minimising the risk of bias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Residual pulmonary artery (PA) anomalies are a major concern after surgery for cono-truncal malformations. This study sought to assess residual PA anomalies using MRI/MRA. Methods: 43 MRI/MRA studies were performed in 37 patients after corrective surgery for cono-truncal malformations. MRI/MRA studies comprised spin-echo, cine, velocity-encoded and 3D Gadolinium-enhanced MRA sequences. Residual PA anomalies were searched in ail patients; angiographie data were available in 13 patients and a comparison with MRI/MRA was made. Results: 32/37 patients had postoperative anomalies of the pulmonary arterial tree. Left pulmonary artery stenosis was the most common finding (14/32), followed by stenosis at multiple sites (11/32). Isolated right pulmonary artery stenosis was rare (2/32). The median time interval between MRI/MRA and angiography in the 13 patients undergoing both types of studies was 54 days. The findings between the two examinations were identical regarding stenoses and collateral vessels. In 4 patients, the MRI/MRA study allowed to plan interventional catheterization with balloon dilatation and/or stenting of the obstructed arteries or co il-occlusion of systemic collaterals. Eleven patients had additional surgery based on MRI/MRA findings. Conclusions: Post-operative anomalies of the PA in cono-truncal malformations can reliably be detected with MRI/MRA. This technique allows planning of the intervention al or surgical procedure to correct the residual anomalies and may th us replace or precede catheterization during the follow-up of surgically corrected cono-truncal malformations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper details an investigation into sensory substitution by means of direct electrical stimulation of the tongue for the purpose of information input to the human brain. In particular, a device has been constructed and a series of trials have been performed in order to demonstrate the efficacy and performance of an electro-tactile array mounted onto the tongue surface for the purpose of sensory augmentation. Tests have shown that by using a low resolution array a computer-human feedback loop can be successfully implemented by humans in order to complete tasks such as object tracking, surface shape identification and shape recognition with no training or prior experience with the device. Comparisons of this technique have been made with visual alternatives and these show that the tongue based tactile array can match such methods in convenience and accuracy in performing simple tasks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, new tools in atmospheric pollutant sampling and analysis were applied in order to go deeper in source apportionment study. The project was developed mainly by the study of atmospheric emission sources in a suburban area influenced by a municipal solid waste incinerator (MSWI), a medium-sized coastal tourist town and a motorway. Two main research lines were followed. For what concerns the first line, the potentiality of the use of PM samplers coupled with a wind select sensor was assessed. Results showed that they may be a valid support in source apportionment studies. However, meteorological and territorial conditions could strongly affect the results. Moreover, new markers were investigated, particularly focusing on the processes of biomass burning. OC revealed a good biomass combustion process indicator, as well as all determined organic compounds. Among metals, lead and aluminium are well related to the biomass combustion. Surprisingly PM was not enriched of potassium during bonfire event. The second research line consists on the application of Positive Matrix factorization (PMF), a new statistical tool in data analysis. This new technique was applied to datasets which refer to different time resolution data. PMF application to atmospheric deposition fluxes identified six main sources affecting the area. The incinerator’s relative contribution seemed to be negligible. PMF analysis was then applied to PM2.5 collected with samplers coupled with a wind select sensor. The higher number of determined environmental indicators allowed to obtain more detailed results on the sources affecting the area. Vehicular traffic revealed the source of greatest concern for the study area. Also in this case, incinerator’s relative contribution seemed to be negligible. Finally, the application of PMF analysis to hourly aerosol data demonstrated that the higher the temporal resolution of the data was, the more the source profiles were close to the real one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To investigate possible leptomeningeal contrast enhancement using postcontrast fluid-attenuated inversion recovery (FLAIR) MRI as an additional marker of inflammation in patients with multiple sclerosis (MS). METHODS A cohort of 112 patients (73 women) with clinically definitive MS or a clinically isolated syndrome suggestive of CNS demyelination were included. A pathologic control group of 5 stroke patients was also examined. MRI was performed on a 3T system including FLAIR, T2-weighted, T1-weighted-contrast injection, followed by T1-weighted and FLAIR. RESULTS Of the 112 patients, 39 had an acute relapse at the time of MRI. In total, 96 contrast-enhancing lesions were identified on postcontrast T1-weighted images. The pathologic control group demonstrated the sensitivity of postcontrast FLAIR images demonstrating leptomeningeal enhancement in all cases. In contrast, only 1 out of 112 examined patients with MS showed a single area of abnormal leptomeningeal contrast enhancement. CONCLUSIONS In contrast to intraparenchymal blood-brain barrier (BBB) dysfunction that is frequently seen in patients with MS, BBB dysfunction of leptomeningeal vessels is usually not detectable in patients with early MS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reasons for performing study: Obtaining magnetic resonance images of the inner hoof wall tissue at the microscopic level would enable early accurate diagnosis of laminitis and therefore more effective therapy. Objectives: To optimise magnetic resonance imaging (MRI) parameters in order to obtain the highest possible resolution of the structures beneath the equine hoof wall. Methods: Magnetic resonance microscopy (MRM) was performed in front feet from 6 cadaver horses using T-2-weighted fast spin echo (FSE-T-2), and T-1-weighted gradient echo (GRE-T-1) sequences. Results: In T-2 weighted FSE images most of the stratum medium showed no signal, however the coronary, terminal and sole papillae were visible. The stratum lamellatum was clearly visible and primary epidermal lamellae could be differentiated from dermal lamellae. Conclusion: Most structures beneath the hoof wall were differentiated. Conventional scanners for diagnostic MRI in horses are low or high field. However this study used ultra-high field scanners currently not available for clinical use. Signal-to-noise ratio (SIN) increases as a function of field strength. An increase of spatial resolution of the image results in a decreased SIN. SIN can also be improved with better coils and the resolution of high field MRI scanners will increase as technology develops and surface array coils become more readily available. Potential relevance: Although MR images with microscopic resolution were obtained ex vivo, this study demonstrates the potential for detection of lamellar pathology as it occurs. Early recognition of the development of laminitis to instigate effective therapy at an earlier stage and may improve the outcome for laminitic horses. Clinical MR is now readily available at 3 T, while 4 T, 7 T and 9 T systems are being used for human whole body applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contrary to previously held beliefs, it is now known that bacteria exist not only on the surface of the skin but they are also distributed at varying depths beneath the skin surface. Hence, in order to sterilise the skin, antimicrobial agents are required to penetrate across the skin and eliminate the bacteria residing at all depths. Chlorhexidine is an antimicrobial agent with the widest use for skin sterilisation. However, due to its poor permeation rate across the skin, sterilisation of the skin cannot be achieved and, therefore, the remaining bacteria can act as a source of infection during an operation or insertion of catheters. The underlying theme of this study is to enhance the permeation of this antimicrobial agent in the skin by employing chemical (enhancers and supersaturated systems) or physical (iontophoresis) techniques. The hydrochloride salt of chlorhexidine (CHX), a poorly soluble salt, was used throughout this study. The effect of ionisation on in vitro permeation rate across the excised human epidennis was investigated using Franz-type diffusion cells. Saturated solutions of CHX were used as donor and the variable studied was vehicle pH. Permeation rate was increased with increasing vehicle pH. The pH effect was not related to the level of ionisation of the drug. The effect of donor vehicle was also studied using saturated solutions of CHX in 10% and 20% ethanol as the donor solutions. Permeation of CHX was enhanced by increasing the concentration of ethanol which could be due to the higher concentration of CHX in the donor phase and the effect of ethanol itself on the membrane. The interplay between drug diffusion and enhancer pretreatment of the epidennis was studied. Pretreatment of the membrane with 10% Azone/PG demonstrated the highest diffusion rate followed by 10% olcic acid/PG pretreatment compared to other pretreatment regimens (ethanol, dimethyl sulfoxide (DMSO), propylene glycol (PG), sodium dodecyl sulphate (SDS) and dodecyl trimethyl ammonium bromide (DT AB). Differential Scanning Calorimetry (DSC) was also employed to study the mode of action of these enhancers. The potential of supersaturated solutions in enhancing percutaneous absorption of CHX was investigated. Various anti-nucleating polymers were screened in order to establish the most effective agent. Polyvinylpyrrolidone (PVP, K30) was found to be a better candidate than its lower molecular weight counterpart (K25) and hydroxypropyl methyleellulose (HPMC). The permeation studies showed an increase in diffusion rate by increasing the degree of saturation. Iontophoresis is a physical means of transdemal drug delivery enhancement that causes an increased penetration of molecules into or through the skin by the application of an electric field. This technique was employed in conjunction with chemical enhancers to assess the effect on CHX permeation across the human epidermis. An improved transport of CHX, which was pH dependant was observed upon application of the current. Combined use of iontophoresis and chemical enhancers further increased the CHX transport indicating a synergistic effect. Pretreatment of the membrane with 10% Azone/PG demonstrated the greatest effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose - Loss of motor function is common after stroke and leads to significant chronic disability. Stem cells are capable of self-renewal and of differentiating into multiple cell types, including neurones, glia, and vascular cells. We assessed the safety of granulocyte-colony-stimulating factor (G-CSF) after stroke and its effect on circulating CD34 stem cells. Methods - We performed a 2-center, dose-escalation, double-blind, randomized, placebo-controlled pilot trial (ISRCTN 16784092) of G-CSF (6 blocks of 1 to 10 g/kg SC, 1 or 5 daily doses) in 36 patients with recent ischemic stroke. Circulating CD34 stem cells were measured by flow cytometry; blood counts and measures of safety and functional outcome were also monitored. All measures were made blinded to treatment. Results - Thirty-six patients, whose mean SD age was 768 years and of whom 50% were male, were recruited. G-CSF (5 days of 10 g/kg) increased CD34 count in a dose-dependent manner, from 2.5 to 37.7 at day 5 (area under curve, P0.005). A dose-dependent rise in white cell count (P0.001) was also seen. There was no difference between treatment groups in the number of patients with serious adverse events: G-CSF, 7/24 (29%) versus placebo 3/12 (25%), or in their dependence (modified Rankin Scale, median 4, interquartile range, 3 to 5) at 90 days. Conclusions - ”G-CSF is effective at mobilizing bone marrow CD34 stem cells in patients with recent ischemic stroke. Administration is feasible and appears to be safe and well tolerated. The fate of mobilized cells and their effect on functional outcome remain to be determined. (Stroke. 2006;37:2979-2983.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Des interventions ciblant l’amélioration cognitive sont de plus en plus à l’intérêt dans nombreux domaines, y compris la neuropsychologie. Bien qu'il existe de nombreuses méthodes pour maximiser le potentiel cognitif de quelqu’un, ils sont rarement appuyé par la recherche scientifique. D’abord, ce mémoire examine brièvement l'état des interventions d'amélioration cognitives. Il décrit premièrement les faiblesses observées dans ces pratiques et par conséquent il établit un modèle standard contre lequel on pourrait et devrait évaluer les diverses techniques ciblant l'amélioration cognitive. Une étude de recherche est ensuite présenté qui considère un nouvel outil de l'amélioration cognitive, une tâche d’entrainement perceptivo-cognitive : 3-dimensional multiple object tracking (3D-MOT). Il examine les preuves actuelles pour le 3D-MOT auprès du modèle standard proposé. Les résultats de ce projet démontrent de l’augmentation dans les capacités d’attention, de mémoire de travail visuel et de vitesse de traitement d’information. Cette étude représente la première étape dans la démarche vers l’établissement du 3D-MOT comme un outil d’amélioration cognitive.