933 resultados para mesh: Electrophysiology


Relevância:

70.00% 70.00%

Publicador:

Resumo:

SPatch is an open source virtual laboratory designed to perform simulated electrophysiological experiments without the technical difficulties inherent to laboratory work. It provides the core equipment necessary for recording neuronal activity and allows the user to install the equipment, design their own protocols, prepare solutions to bathe the preparation or to fill the electrodes, and gather data. Assistance is provided for most steps with predefined components that are appropriate to a range of standard procedures. Experiments that can be performed with SPatch at present concern the study of voltage-gated channels in isolated neurons. This allows understanding the ionic mechanisms of Na+ and Ca2+ action potentials, after spike hyperpolarization, pacemaker tonic or bursting activity of neurons, delayed or sustained or adaptive firing of neurons in response to a depolarization, spontaneous depolarization of the membrane following an hyperpolarization, etc. In an educational context, the main interest of SPatch is to allow students to focus on the concepts and thought processes of electrophysiological investigation without the high equipment costs and extensive training required to perform laboratory work. It can be used to acquaint students with the relevant procedures before starting work in a real lab, or to give students an understanding of single neuron behavior and the ways it can be studied without requiring practical work. We illustrate the function and use of SPatch, explore educational issues arising from the inevitable differences between simulated and real laboratory work, and outline possible improvements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neurons in Action (NIA1, 2000; NIA1.5, 2004; NIA2, 2007), a set of tutorials and linked simulations, is designed to acquaint students with neuronal physiology through interactive, virtual laboratory experiments. Here we explore the uses of NIA in lecture, both interactive and didactic, as well as in the undergraduate laboratory, in the graduate seminar course, and as an examination tool through homework and problem set assignments. NIA, made with the simulator NEURON (http://www.neuron.yale.edu/neuron/), displays voltages, currents, and conductances in a membrane patch or signals moving within the dendrites, soma and/or axon of a neuron. Customized simulations start with the plain lipid bilayer and progress through equilibrium potentials; currents through single Na and K channels; Na and Ca action potentials; voltage clamp of a patch or a whole neuron; voltage spread and propagation in axons, motoneurons and nerve terminals; synaptic excitation and inhibition; and advanced topics such as channel kinetics and coincidence detection. The user asks and answers "what if" questions by specifying neuronal parameters, ion concentrations, and temperature, and the experimental results are then plotted as conductances, currents, and voltage changes. Such exercises provide immediate confirmation or refutation of the student's ideas to guide their learning. The tutorials are hyperlinked to explanatory information and to original research papers. Although the NIA tutorials were designed as a sequence to empower a student with a working knowledge of fundamental neuronal principles, we find that faculty are using the individual tutorials in a variety of educational situations, some of which are described here. Here we offer ideas to colleagues using interactive software, whether NIA or another tool, for educating students of differing backgrounds in the subject of neurophysiology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Simulation tools aid in learning neuroscience by providing the student with an interactive environment to carry out simulated experiments and test hypotheses. The field of neuroscience is well suited for the use of simulation tools since nerve cell signaling can be described by mathematical equations and solved by computer. Neural signaling entails the propagation of electrical current along nerve membrane and transmission to neighboring neurons through synaptic connections. Action potentials and synaptic transmission can be simulated and results displayed for visualization and analysis. The neurosimulator SNNAP (Simulator for Neural Networks and Action Potentials) is a simulation environment that provides users with editors for model building, simulator engine and visual display editor. This paper presents several modeling examples that illustrate some of the capabilities and features of SNNAP. First, the Hodgkin-Huxley (HH) model is presented and the threshold phenomenon is illustrated. Second, small neural networks are described with HH models using various synaptic connections available with SNNAP. Synaptic connections may be modulated through facilitation or depression with SNNAP. A study of vesicle pool dynamics is presented using an AMPA receptor model. Finally, a central pattern generator model of the Aplysia feeding circuit is illustrated as an example of a complex network that may be studied with SNNAP. Simulation code is provided for each case study described and tasks are suggested for further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate an experimental animal model to study the abdominal tissue activity considering its interaction with a polypropylene mesh, through the use of one of the optical phenomena of light Laser, the biospeckle. METHODS: Fifty Wistar male rats were divided into four groups: Group 1: ten animals not submitted to surgery; Group 2: ten animals submitted to surgery without polypropylene mesh; Group 3: 20 animals submitted to surgery followed by the mesh placement; Group 4: (sham) with ten animals. None of the animals presented post surgical complications being submitted to the optical tests at the 20th postoperative day. RESULTS: The analysis from the biospeckle tests, comparing the medians and standard deviations with T Student test, indicated that no significative difference was observed on the abdominal wall tissue activity in the four groups considered, with and without polypropylene mesh prosthesis implantation. CONCLUSION: The animal model is viable and the biospeckle open ways for a great number of experiments to be developed in evaluating tissue activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Internet users are increasingly using the worldwide web to search for information relating to their health. This situation makes it necessary to create specialized tools capable of supporting users in their searches. Objective: To apply and compare strategies that were developed to investigate the use of the Portuguese version of Medical Subject Headings (MeSH) for constructing an automated classifier for Brazilian Portuguese-language web-based content within or outside of the field of healthcare, focusing on the lay public. Methods: 3658 Brazilian web pages were used to train the classifier and 606 Brazilian web pages were used to validate it. The strategies proposed were constructed using content-based vector methods for text classification, such that Naive Bayes was used for the task of classifying vector patterns with characteristics obtained through the proposed strategies. Results: A strategy named InDeCS was developed specifically to adapt MeSH for the problem that was put forward. This approach achieved better accuracy for this pattern classification task (0.94 sensitivity, specificity and area under the ROC curve). Conclusions: Because of the significant results achieved by InDeCS, this tool has been successfully applied to the Brazilian healthcare search portal known as Busca Saude. Furthermore, it could be shown that MeSH presents important results when used for the task of classifying web-based content focusing on the lay public. It was also possible to show from this study that MeSH was able to map out mutable non-deterministic characteristics of the web. (c) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a novel wire-mesh sensor based on permittivity (capacitance) measurements is applied to generate images of the phase fraction distribution and investigate the flow of viscous oil and water in a horizontal pipe. Phase fraction values were calculated from the raw data delivered by the wire-mesh sensor using different mixture permittivity models. Furthermore, these data were validated against quick-closing valve measurements. Investigated flow patterns were dispersion of oil in water (Do/w) and dispersion of oil in water and water in oil (Do/w&w/o). The Maxwell-Garnett mixing model is better suited for Dw/o and the logarithmic model for Do/w&w/o flow pattern. Images of the time-averaged cross-sectional oil fraction distribution along with axial slice images were used to visualize and disclose some details of the flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improvement to the quality bidimensional Delaunay mesh generation algorithm, which combines the mesh refinement algorithms strategy of Ruppert and Shewchuk is proposed in this research. The developed technique uses diametral lenses criterion, introduced by L. P. Chew, with the purpose of eliminating the extremely obtuse triangles in the boundary mesh. This method splits the boundary segment and obtains an initial prerefinement, and thus reducing the number of necessary iterations to generate a high quality sequential triangulation. Moreover, it decreases the intensity of the communication and synchronization between subdomains in parallel mesh refinement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of synthetic mesh for abdominal wall closure after removal of the rectus abdominis is established but not standardised. This study compares two forms of mesh fixation: a simple suture, which fixes the mesh to the edges of the defect on the anterior rectus abdominis fascia; and total fixation, which incorporates the fasciae of the internal oblique, external oblique and transverse muscles in the suture, anchoring the mesh in the position of the removed muscle. Method: A total of 16 fresh cadavers were dissected. Two sutures were compared: simple and total. Three different sites were analysed: 5 cm above, 5 cm below and at the level of the umbilicus. The two sutures compared were tested in each region using a standardised technique. All sutures were performed with nylon 0, perpendicular to the linea alba. Each suture was secured to a dynamometer, which was pulled perpendicularly towards the midline until the rupture of the aponeurosis. `Rupture resistance` was measured in kilogram force. The mean among the groups was compared using the paired Student`s t-test to a significance level of 1% (p < 0.01). Results: The mean rupture resistance of the total suture was 160% higher than that of the simple suture. Conclusion: The total suture includes the external oblique, internal oblique and transverse fasciae, which are multi-directional, and creates a much higher resistance when compared with the simple suture. Total suture may reduce the incidence of bulging and hernias of the abdominal wall after harvesting the rectus abdominis muscle, but comparative clinical studies are necessary. (C) 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative vector control method, using lambda-cyhalothrin impregnated wide-mesh gauze covering openings in the walls of the houses was developed in an area in the Eastern part of the interior of Suriname. Experimental hut observations showed that Anopheles darlingi greatly reduced their biting activity (99-100%) during the first 5 months after impregnation. A model assay showed high mortality both of mosquitoes repelled by the gauze as well as of those that succeeded in getting through it. A field application test in 270 huts showed good acceptance by the population and good durability of the applied gauze. After introducing the method in the entire working area, replacing DDT residual housespraying, the malaria prevalence, of 25-37% before application dropped and stabilized at between 5 and 10% within one year. The operational costs were less than those of the previously used DDT housespraying program, due to a 50% reduction in the cost of materials used. The method using widemesh gauze impregnated with lambdacyhalothrin strongly affects the behavior of An. darlingi. It is important to examine the effect of the method on malaria transmission further, since data indirectly obtained suggest substantial positive results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores - Área de Especialização de Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crescente tendencia no acesso móvel tem sido potenciada pela tecnologia IEEE 802.11. Contudo, estas redes têm alcance rádio limitado. Para a extensão da sua cobertura é possível recorrer a redes emalhadas sem fios baseadas na tecnologia IEEE 802.11, com vantagem do ponto de vista do custo e da flexibilidade de instalação, face a soluções cabladas. Redes emalhadas sem fios constituídas por nós com apenas uma interface têm escalabilidade reduzida. A principal razão dessa limitação deve-se ao uso do mecanismo de acesso ao meio partilhado Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA) em topologias multi-hop. Especificamente, o CSMA/CA não evita o problema do nó escondido levando ao aumento do número de colisões e correspondente degradação de desempenho com impacto direto no throughput e na latência. Com a redução da tecnologia rádio torna-se viável a utilização de múltiplos rádios por nó, sem com isso aumentar significativamente o custo da solução final de comunicações. A utilização de mais do que um rádio por nó de comuniações permite superar os problemas de desempenho inerentes ás redes formadas por nós com apenas um rádio. O objetivo desta tese, passa por desenvolver uma nova solução para redes emalhadas multi-cana, duar-radio, utilizando para isso novos mecanismos que complementam os mecanismos definidos no IEEE 802.11 para o estabelecimento de um Basic Service Set (BSS). A solução é baseada na solução WiFIX, um protocolo de routing para redes emalhadas de interface única e reutiliza os mecanismos já implementados nas redes IEEE 802.11 para difundir métricas que permitam à rede escalar de forma eficaz minimizando o impacto na performance. A rede multi-hop é formada por nós equipados com duas interfaces, organizados numa topologia hierárquica sobre múltiplas relações Access Point (AP) – Station (STA). Os resultados experimentais obtidos mostram a eficácia e o bom desempenho da solução proposta face à solução WiFIX original.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on a survey sent to Portuguese centers that perform diagnostic and interventional electrophysiology and/or implantable cardioverter-defibrillator (ICD) implantations, the authors analyze the number and type of procedures performed during 2012 and compare these data with previous years. In 2012, a total of 2561 diagnostic electrophysiologic studies were performed, which were followed by ablation in 2017 cases, representing a steady situation compared with the previous year. There was a 12% increase in the number of ablation procedures for atrial fibrillation, making it for the first time the most frequent indication for ablation, overtaking atrioventricular nodal reentrant tachycardia. The total number of first ICD implantations was 1048 (around 100 per million population), of which 375 were cardiac resynchronization devices (BiV ICDs). This represents a slight decrease (3.3%) in the total number of new implants, with an increase of 10% in the number of BiV ICDs compared to the previous year. However, there was a considerable increase in the number of ICD generator replacements, resulting in an overall increase of 3.5% in implantations performed in 2012. Some comments are made regarding developments in this activity and its current status, and on some factors that may influence the dynamics of this area of interventional cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless mesh networks present an attractive communication solution for various research and industrial projects. However, in many cases, the appropriate preliminary calculations which allow predicting the network behavior have to be made before the actual deployment. For such purposes, network simulation environments emulating the real network operation are often used. Within this paper, a behavior comparison of real wireless mesh network (based on 802.11s amendment) and the simulated one has been performed. The main objective of this work is to measure performance parameters of a real 802.11s wireless mesh network (average UDP throughput and average one-way delay) and compare the derived results with characteristics of a simulated wireless mesh network created with the NS-3 network simulation tool. Then, the results from both networks are compared and the corresponding conclusion is made. The corresponding results were derived from simulation model and real-worldtest-bed, showing that the behavior of both networks is similar. It confirms that the NS-3 simulation model is accurate and can be used in further research studies.