985 resultados para mechanical management


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Vachellia nilotica ssp. indica (hereafter, V. n. indica) is an important tree weed in Australia. Its dense populations induce undesirable changes in the vast areas of northern Australia. Because chemical and mechanical management options appear unviable for various reasons, biological management of this tree is considered a better option. Among the many trialled arthropods in Australian context, Anomalococcus indicus, a lecanodiaspid native to India, has been identified as a potent-candidate, since in India, its native terrain, it is the most widespread and occurs throughout the year. Severe infestations of A. indicus cause defoliation, wilting and death of branches, and occasionally the tree. Populations of A. indicus have been brought into Australia and are being tested for its host specificity under quarantine conditions. This article reports the physiological damage and stress it inflicts in the shoots of V. n. indica. Younger-nymphal instars of A. indicus feed on cortical-parenchyma cells of young stems, whereas the older instars and adults feed from the phloem of old stems. Two conspicuous responses of V. n. indica arising in response to the feeding action of A. indicus are changes in the cell-wall dynamics and irregular cell divisions. The feeding action of A. indicus elicits a sequence of reactions in the stem tissues of V. n. indica such as differentiation of thick-walled elements in the outer cortical parenchyma, differential thickening of cells with supernumerary layers of either suberin or lignin, proliferations of parenchyma and phloem, wall thickening and obliteration of inner lumen of phloem cells, and the sieve plates plugged with callosic deposits. The responses are the culminations of interaction between the virulence factor (one or more of the salivary proteins?) from A. indicus and the resistance factor in V. n. indica. We have analysed structural changes in the context of their functions, by comparing the feeding action of A. indicus with that of other hemipteroids. From the level of stress it induces, this study confirms that A. indicus has the potential to be an effective biological management of V. n. indica in Australia. © 2014 © 2014 Taylor & Francis and Aboricultural Association.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nas culturas agrícolas as plantas daninhas devem ser controladas de modo a não afetar negativamente o rendimento e a qualidade do produto colhido. Deste modo, quantidades pequenas de plantas daninhas em um campo, na maioria dos casos, não é um problema, exceto na produção de sementes. Ressalta-se que em gramados não existe um componente de produção a se colhido. O valor do gramado é a sua qualidade inerente a estética e usabilidade. Qualidade estética é a beleza e o valor que acrescenta ao gramado em uma paisagem gerenciada. Usabilidade pode ser a durabilidade de um campo de esporte ou a redução na perda de solo pela erosão da água ou do vento. A presença de qualquer planta daninha em gramados pode diminuir a qualidade estética e usabilidade do gramado. Enquanto for possível reduzir a população de plantas daninhas utilizando práticas culturais ou mecânicas, não se poderá eliminá-las completamente. A utilização de herbicidas é a única maneira de controlar completamente as plantas daninhas em áreas de gramados. Esta revisão irá rever os principais herbicidas utilizados em gramados nos Estados Unidos com relação a seus modos de ação, a família de herbicidas e uso primário no gramado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In a 9-year-old boy, bridging to transplantation was successful with an external biventricular device, the Berlin Heart Excor (Berlin Heart, Berlin, Germany), during a 7-month period. Main long-term complications consisted of infection and hypercoagulability with clotting inside the chambers necessitating six pump exchanges, but without thromboembolic events. This report reviews hemostasis monitoring and management of long-term mechanical circulatory support.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the past few years indications for the use of the air polishing technology have been expanded from supragingival use (airflow) to subgingival air polishing (perioflow) by the development of new low-abrasive glycine-based powders and devices with a subgingival nozzle. Several studies on the subgingival use of air polishing have been completed. On 7 June 2012, during the Europerio 7 Congress in Vienna, a consensus conference on mechanical biofilm management took place aiming to review the current evidence from the literature on the clinical relevance of the subgingival use of air polishing and to make practical recommendations for the clinician. Bernita Bush (Bern), Prof Johannes Einwag (Stuttgart), Prof Thomas Flemmig (Seattle), Carmen Lanoway (Munich), Prof Ursula Platzer (Hamburg), Prof Petra Schmage (Hamburg), Brigitte Schoeneich (Zurich), Prof Anton Sculean (Bern), Dr Clemens Walter (Basel), and Prof Jan Wennström (Gothenburg) discussed under the moderation of Klaus-Dieter Bastendorf and Christian Becker (both ADIC Association for Dental Infection Control) the available clinical studies to reach a consensus on available clinical evidence. This paper summarizes the main conclusions of the consensus conference and points to the clinical relevance of the findings for the dental practitioner.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIM To systematically assess the efficacy of patient-administered mechanical and/or chemical plaque control protocols in the management of peri-implant mucositis (PM). MATERIAL AND METHODS Randomized (RCTs) and Controlled Clinical Trials (CCTs) were identified through an electronic search of three databases complemented by manual search. Identification, screening, eligibility and inclusion of studies was performed independently by two reviewers. Studies without professional intervention or with only mechanical debridement professionally administered were included. Quality assessment was performed by means of the Cochrane Collaboration's tool for assessing risk of bias. RESULTS Eleven RCTs with a follow-up from 3 to 24 months were included. Definition of PM was lacking or heterogeneously reported. Complete resolution of PM was not achieved in any study. One study reported 38% of patients with complete resolution of PM. Surrogate end-point outcomes of PM therapy were often reported. The choice of control interventions showed great variability. The efficacy of powered toothbrushes, a triclosan-containing toothpaste and adjunctive antiseptics remains to be established. High quality of methods and reporting was found in four studies. CONCLUSIONS Professionally- and patient-administered mechanical plaque control alone should be considered the standard of care in the management of PM. Therapy of PM is a prerequisite for the prevention of peri-implantitis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study of ventilated patients investigated current clinical practice in 476 episodes of pneumonia (48% community-acquired pneumonia, 24% hospital-acquired pneumonia, 28% ventilator-associated pneumonia) using a prospective survey in 14 intensive care units (ICUs) within Australia and New Zealand. Diagnostic methods and confidence, disease severity, microbiology and antibiotic use were assessed. All pneumonia types had similar mortality (community-acquired pneumonia 33%, hospital-acquired pneumonia 37% and ventilator-associated pneumonia 24%, P = 0.15) with no inter-hospital differences (P = 0.08-0.91). Bronchoscopy was performed in 26%, its use predicted by admission hospital (one tertiary: OR 9.98, CI 95% 5.11-19.49, P < 0.001; one regional: OR 629, CI 95% 3.24-12.20, P < 0.001), clinical signs of consolidation (OR 3.72, CI 95% 2.09-662, P < 0.001) and diagnostic confidence (OR 2.19, CI 95% 1.29-3.72, P = 0.004). Bronchoscopy did not predict outcome (P = 0.11) or appropriate antibiotic selection (P = 0.69). Inappropriate antibiotic prescription was similar for all pneumonia types (11-13%, P = 0.12) and hospitals (0-16%, P = 0.25). Blood cultures were taken in 51% of cases. For community-acquired pneumonia, 70% received a third generation cephalosporin and 65% a macrolide. Third generation cephalosporins were less frequently used for mild infections (OR 0.38, CI 95% 0.16-0.90, P = 0.03), hospital-acquired pneumonia (OR 0.40, CI 95% 0.23-0.72, P < 0.01), ventilator-associated pneumonia (OR 0.04, CI 95% 0.02-0.13, P < 0.001), suspected aspiration (OR 0.20, CI 95% 0.04-0.92, P = 0.04), in one regional (OR 0.26, CI 95% 0.07-0.97, P = 0.05) and one tertiary hospital (OR 0.14, CI 95% 0.03-0.73, P = 0.02) but were more commonly used in older patients (OR 1.02, CI 95% 1.01-1.03, P = 0.01). There is practice variability in bronchoscopy and antibiotic use for pneumonia in Australian and New Zealand ICUs without significant impact on patient outcome, as the prevalence of inappropriate antibiotic prescription is low. There are opportunities for improving microbiological diagnostic work-up for isolation of aetiological pathogens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical harmonic transmissions are relatively new kind of drives having several unusual features. For example, they can provide reduction ratio up to 500:1 in one stage, have very small teeth module compared to conventional drives and very large number of teeth (up to 1000) on a flexible gear. If for conventional drives manufacturing methods are well-developed, fabrication of large size harmonic drives presents a challenge. For example, how to fabricate a thin shell of 1.7m in diameter and wall thickness of 30mm having high precision external teeth at one end and internal splines at the other end? It is so flexible that conventional fabrication methods become unsuitable. In this paper special fabrication methods are discussed that can be used for manufacturing of large size harmonic drive components. They include electro-slag welding and refining, the use of special expandable devices to locate and hold a flexible gear, welding peripheral parts of disks with wear resistant materials with subsequent machining and others. These fabrication methods proved to be effective and harmonic drives built with the use of these innovative technologies have been installed on heavy metallurgical equipment and successfully tested.