988 resultados para mechanical loading


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The texture of agricultural crops changes during harvesting, post harvesting and processing stages due to different loading processes. There are different source of loading that deform agricultural crop tissues and these include impact, compression, and tension. Scanning Electron Microscope (SEM) method is a common way of analysing cellular changes of materials before and after these loading operations. This paper examines the structural changes of pumpkin peel and flesh tissues under mechanical loading. Compression and indentation tests were performed on peel and flesh samples. Samples structure were then fixed and dehydrated in order to capture the cellular changes under SEM. The results were compared with the images of normal peel and flesh tissues. The findings suggest that normal flesh tissue had bigger size cells, while the cellular arrangement of peel was smaller. Structural damage was clearly observed in tissue structure after compression and indentation. However, the damages that resulted from the flat end indenter was much more severe than that from the spherical end indenter and compression test. An integrated deformed tissue layer was observed in compressed tissue, while the indentation tests shaped a deformed area under the indenter and left the rest of the tissue unharmed. There was an obvious broken layer of cells on the walls of the hole after the flat end indentations, whereas the spherical indenter created a squashed layer all around the hole. Furthermore, the influence of loading was lower on peel samples in comparison with the flesh samples. The experiments have shown that the rate of damage on tissue under constant rate of loading is highly dependent on the shape of equipment. This fact and observed structural changes after loading underline the significance of deigning post harvesting equipments to reduce the rate of damage on agricultural crop tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the formation of a stable Body-Centered Heptahedral (BCH) crystalline nanobridge structure of diameter ~ 1nm under high strain rate tensile loading to a <100> Cu nanowire. Extensive Molecular Dynamics (MD) simulations are performed. Six different cross-sectional dimensions of Cu nanowires are analyzed, i.e. 0.3615 x 0.3615 nm2, 0.723 x 0.723 nm2, 1.0845 x 1.0845 nm2, 1.446 x 1.446 nm2, 1.8075 x 1.8075 nm2, and 2.169 x 2.169 nm2. The strain rates used in the present simulations are 1 x 109 s-1, 1 x 108 s-1, and 1 x 107 s-1. We have shown that the length of the nanobridge can be characterized by larger plastic strain. A large plastic deformation is an indication that the structure is highly stable. The BCH nanobridge structure also shows enhanced mechanical properties such as higher fracture toughness and higher failure strain. The effect of temperature, strain rate and size of the nanowire on the formation of BCH structure is also explained in details. We also show that the initial orientation of the nanowires play an important role on the formation of BCH crystalline structure. Results indicate that proper tailoring of temperature and strain rate during processing or in the device can lead to very long BCH nanobridge structure of Cu with enhanced mechanical properties, which may find potential application for nano-scale electronic circuits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work focuses on the formulation of an asymptotically correct theory for symmetric composite honeycomb sandwich plate structures. In these panels, transverse stresses tremendously influence design. The conventional 2-D finite elements cannot predict the thickness-wise distributions of transverse shear or normal stresses and 3-D displacements. Unfortunately, the use of the more accurate three-dimensional finite elements is computationally prohibitive. The development of the present theory is based on the Variational Asymptotic Method (VAM). Its unique features are the identification and utilization of additional small parameters associated with the anisotropy and non-homogeneity of composite sandwich plate structures. These parameters are ratios of smallness of the thickness of both facial layers to that of the core and smallness of 3-D stiffness coefficients of the core to that of the face sheets. Finally, anisotropy in the core and face sheets is addressed by the small parameters within the 3-D stiffness matrices. Numerical results are illustrated for several sample problems. The 3-D responses recovered using VAM-based model are obtained in a much more computationally efficient manner than, and are in agreement with, those of available 3-D elasticity solutions and 3-D FE solutions of MSC NASTRAN. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exercise during growth results in biologically important increases in bone mineral content (BMC). The aim of this study was to determine whether the effects of loading were site specific and depended on the maturational stage of the region. BMC and humeral dimensions were determined using DXA and magnetic resonance imaging (MRI) of the loaded and nonloaded arms in 47 competitive female tennis players aged 8-17 years. Periosteal (external) cross-sectional area (CSA), cortical area, medullary area, and the polar second moments of area (Ip, mm4) were calculated at the mid and distal sites in the loaded and nonloaded arms. BMC and I p of the humerus were 11-14% greater in the loaded arm than in the nonloaded arm in prepubertal players and did not increase further in peri- or postpubertal players despite longer duration of loading (both, p < 0.01). The higher BMC was the result of a 7-11% greater cortical area in the prepubertal players due to greater periosteal than medullary expansion at the midhumerus and a greater periosteal expansion alone at the distal humerus. Loading late in puberty resulted in medullary contraction. Growth and the effects of loading are region and surface specific, with periosteal apposition before puberty accounting for the increase in the bone's resistance to torsion and endocortical contraction contributing late in puberty conferring little increase in resistance to torsion. Increasing the bone's rt.osistance to torsion is achieved hy modifying bone shape and mass, not necessarily bone density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective
To investigate tenocyte regulatory events during the development of overuse supraspinatus tendinosis in rats.

Methods
Supraspinatus tendinosis was induced by running rats downhill at 1 km/hour for 1 hour a day. Tendons were harvested at 4, 8, 12, and 16 weeks and processed for brightfield, polarized light, or transmission electron microscopy. The development of tendinosis was assessed semiquantitatively using a modified Bonar histopathologic scale. Apoptosis and proliferation were examined using antibodies against fragmented DNA or proliferating cell nuclear antigen, respectively. Insulin-like growth factor 1 (IGF-1) expression was determined by computer-assisted quantification of immunohistochemical reaction. Local IGF-1 signaling was probed using antibodies to phosphorylated insulin receptor substrate 1 (IRS-1) and ERK-1/2.

Results
Tendinosis was present after 12 weeks of downhill running and was characterized by tenocyte rounding and proliferation as well as by glycosaminoglycan accumulation and collagen fragmentation. The proliferation index was elevated in CD90+ tenocytes in association with tendinosis and correlated with increased local IGF-1 expression by tenocytes and phosphorylation of IRS-1 and ERK-1/2. Both apoptosis and cellular inflammation were absent at all time points.

Conclusion
In this animal model, early tendinosis was associated with local stimulation of tenocytes rather than with extrinsic inflammation or apoptosis. Our data suggest a role for IGF-1 in the load-induced tenocyte responses during the pathogenesis of overuse tendon disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The role of apoptosis, or programmed cell death, has only recently been explored in tendon.

Objective: To investigate the development of apoptosis after high strain loading of rat tendon.

Methods: The right tibialis anterior tendons of three rats were prepared for mechanical loading, and left tendons were prepared identically as non-loaded controls. Tendon was loaded with 20% strain for six hours using a 1 Hz longitudinal sine wave signal. The following were used to assess apoptosis: (a) a monoclonal mouse antibody (F7-26) to label single stranded DNA breaks; (b) a rabbit polyclonal antibody that specifically recognises the cleaved form of caspase-3.

Results: Light microscopy confirmed that the high strain protocol induced a stretch overload injury. Control tendons showed little or no staining with the F7-26 antibody, but the loaded tendons displayed numerous apoptotic cells. The percentage of apoptotic cells (20%) in the loaded tendon was significantly greater than in the control tendon (1%) (p = 0.000). The labelled cells colocalised with abnormal nuclear morphology, including nuclear fragmentation. The staining against cleaved caspase-3 was positive in loaded tendons only, and localised both to nucleus and cytoplasm.

Conclusion:
This experiment extends knowledge of human tendon apoptosis by showing that apoptosis can occur in response to short term, high strain mechanical loading. This is the first report of mechanical loading of intact tendon causing excessive apoptosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE
Before exercise prescription for bone health can be recommended, the relationship between mechanical loading characteristics and the skeletal response need to be quantified. We asked i) does moderate impact exercise result in a greater gain in BMC than low impact exercise, ii) what are the loading characteristics associated with a moderate and low impact exercise program and does this differ from non-structured play?, and iii) does loading history affect the osteogenic response to a moderate or low impact program?

METHODS
Sixty-eight pre- and early-pubertal girls (aged 8.9 +/- 0.2 yrs) were randomized to take part in a moderate or low impact exercise program 3 times/wk for 8.5 mnths. The number and type of loads associated with the exercise classes and non-structured play (recess) were assessed from video footage. The magnitude of load was assessed using a pedar in-sole mobile system. Hours of moderate and high impact organized sport were assessed from a physical activity questionnaire.

RESULTS
The moderate and low impact exercise programs consisted of -400 impacts per class, but the jumping, hopping and dynamic activities performed during the moderate impact program produced forces ranging from 2 to 4 times body weight (BW) compared to -1 BW for the low impact program. Moderate impact exercise resulted in a 2.7% greater gain in BMC at the tibia compared to the low impact exercise. The moderate impact exercise program consisted of fewer low impacts (1-2 BW) and a higher number of moderate impacts (2-4BW) compared to those typically performed during non-structured play. There were greater gains in BMC in subjects participating in the moderate versus the low impact exercise programs who participated in 2 to 3 hours of moderate impact sports outside school (2.5% to 4.5%, p

CONCLUSION
Approximately 400 impacts ranging 2-4 BW, 3 times/wk was enough stimuli to result in an osteogenic response in normally active girls; even in those actively involved in moderate impact sports outside school.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Smith machine is a pervasive weight-training apparatus, used extensively by a wide population of weight trainers, from novices to high-level athletes. The advantages of using a Smith machine over free-weight resistance are disputed, with conflicting findings reported in the literature. In this study, we are interested in practical differences between 3 types of loading mechanisms found in modern Smith machines. In addition to the basic design comprising a constrained weighted barbell, alterations with a counterweight and a viscous resistance component are examined. The approach taken is that of employing a recently proposed representation of force characteristics that may be exhibited by a trainee and a predictive model of thus effected adaptation. A computer simulation is used to predict the effects of the 3 linear Smith machine designs in the framework of different exercise protocols. Our results demonstrate that each resistance component, vertically constrained load, counterweight, and viscous, can be matched with a particular training context, in which it should be preferred. Thus, a number of practical guidelines for weight-training practitioners are recommended. In summary, (a) at low intensities (55–75% of 1 repetition maximum [1RM]) used in strength-endurance training, a viscous resistance containing the Smith machine was found to offer advantages over both a constrained load only and counterweighted designs; (b) at medium intensities (75–85% of 1RM) typically employed in hypertrophy-specific training, the counterweighted Smith machine design was found to offer the best choice in terms of high-force development and total external work performed; finally, (c) at high training intensity (90–100% of 1RM), the optimal prescription was found to be more dependent on the specific athlete’s weaknesses, highlighting the need for continual monitoring of the athlete’s force production capabilities. To ensure that appropriate adjustments are made to the athlete’s training regimen, the practitioner should consider the full set of findings of this article and the accompanying discussion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. This study evaluated the effect of thermal- and mechanical-cycling on the shear bond strength of three low-fusing glassy matrix dental ceramics to commercial pure titanium (cpTi) when compared to conventional feldspathic ceramic fused to gold alloy.Methods. Metallic frameworks (diameter: 5 min, thickness: 4 mm) (N = 96, n = 12 per group) were cast in cpTi and gold alloy, airborne particle abraded with 150 mu m aluminum oxide. Low-fusing glassy matrix ceramics and a conventional feldspathic ceramic were fired onto the alloys (thickness: 4mm). Four experimental groups were formed; Gr1 (control group): Vita Omega 900-Au-Pd alloy; Gr2: Ticeram-cpTi; Gr3: Super Porcelain Ti-22-cpTi and G4: Vita Titankeramik-cpTi. While half of the specimens from each ceramic-metal combination were randomly tested without aging (water storage at 37 C for 24h only), the other half were first thermocycled (6000 cycles, between 5 and 55 C, dwell time: 13 s) and then mechanically loaded (20,000 cycles under SON load, immersion in distilled water at 37 C). The ceramic-alloy interfaces were loaded under shear in a universal test machine (cross-head speed: 0.5 mm/min) until failure occur-red. Failure types were noted and the interfaces of the representative fractured specimens from each group were examined with stereo microscope and scanning electron microscope (SEM). in an additional study (N = 16, n = 2 per group), energy dispersive X-ray spectroscopy (EDS) analysis was performed from ceramic-alloy interfaces. Data were analyzed using ANOVA and Tukey's test.Results. Both ceramic-metal combinations (p < 0.001) and aging conditions (p < 0,001) significantly affected the mean bond strength values. Thermal- and mechanical-cycling decreased the bond strength (MPa) results significantly for Gr3 (33.4 +/- 4.2) and Gr4 (32.1 +/- 4.8) when compared to the non-aged groups (42.9 +/- 8.9, 42.4 +/- 5.2, respectively). Gr1 was not affected significantly from aging conditions (61.3 +/- 8.4 for control, 60.7 +/- 13.7 after aging) (p > 0.05). Stereomicroscope images showed exclusively adhesive failure types at the opaque ceramic-cpTi interfacial zone with no presence of ceramic on the substrate surface but with a visible dark titanium oxide layer in Groups 2-4 except Gr1 where remnants of bonder ceramic was visible. EDS analysis from the interfacial zone for cpTi-ceramic groups showed predominantly 34.5-85.1% O(2) followed by 1.1-36.7% Aland 0-36.3% Si except for Super Porcelain Ti-22 where a small quantity of Ba (1.4-8.3%), S (0.7%) and Sn (35.3%) was found. In the Au-Pd alloy-ceramic interface, 56.4-69.9% O(2) followed by 15.6-26.2% Si, 3.9-10.9% K, 2.8-6% Na, 4.4-9.6% Al and 0-0.04% Mg was observed.Significance. After thermal-cycling for 6000 times and mechanical-cycling for 20,000 times, Triceram-cpTi combination presented the least decrease among other ceramic-alloy combinations when compared to the mean bond strength results with Au-Pd alloy-Vita Omega 900 combination. (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the winding process of HTS coils the tapes of Bi-2223 are subjected to the influence of bending strain, axial strain, compressive force and torsional deformation resulting in I-c degradation. In the literature the effects of the individual strain components are separately analyzed in spite of during coil winding and energizing the strain-stress effects are combined. In this work using commercial tapes of Bi-2223 Ag/AgMg with and without stainless steel reinforcement several samples were wound on cylindrical FRP G-10 holder in which different combined strains are applied. Measurements of I - V characteristic curves are done to determine the degree of critical current degradation and the operational limits. The results are compared with the I, values of short samples and other specimens subjected to deformation generated by loading types such as tensile and bending strain.