11 resultados para malunion
Resumo:
Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was m adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through 1 bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.
Resumo:
Objective The Nintendo Wii Fit integrates virtual gaming with body movement, and may be suitable as an adjunct to conventional physiotherapy following lower limb fractures. This study examined the feasibility and safety of using the Wii Fit as an adjunct to outpatient physiotherapy following lower limb fractures, and reports sample size considerations for an appropriately powered randomised trial. Methodology Ambulatory patients receiving physiotherapy following a lower limb fracture participated in this study (n = 18). All participants received usual care (individual physiotherapy). The first nine participants also used the Wii Fit under the supervision of their treating clinician as an adjunct to usual care. Adverse events, fracture malunion or exacerbation of symptoms were recorded. Pain, balance and patient-reported function were assessed at baseline and discharge from physiotherapy. Results No adverse events were attributed to either the usual care physiotherapy or Wii Fit intervention for any patient. Overall, 15 (83%) participants completed both assessments and interventions as scheduled. For 80% power in a clinical trial, the number of complete datasets required in each group to detect a small, medium or large effect of the Wii Fit at a post-intervention assessment was calculated at 175, 63 and 25, respectively. Conclusions The Nintendo Wii Fit was safe and feasible as an adjunct to ambulatory physiotherapy in this sample. When considering a likely small effect size and the 17% dropout rate observed in this study, 211 participants would be required in each clinical trial group. A larger effect size or multiple repeated measures design would require fewer participants.
Resumo:
Le cubitus proximal détient une courbe sagittale unique pour chaque individu, nommée « Proximal Ulna Dorsal Angulation (PUDA) ». Une reconstruction non-anatomique du cubitus proximal, suite à une fracture complexe peut engendrer une malunion, de l’arthrose et de l’instabilité. L’objectif de cette étude était d’évaluer la magnitude de malalignement au niveau de l’angulation proximale dorsale du cubitus qui causerait un malalignement radio-capitellaire, avec et sans un ligament annulaire intact. Afin d’atteindre cet objectif, une étude biomécanique fut conduite sur six spécimens frais congelés avec un simulateur de mouvement du coude. Des fractures simulées au niveau du PUDA, furent stabilisées avec une fixation interne dans cinq configurations différentes. Des images fluoroscopiques furent prises dans différentes positions du coude et de l’avant-bras, avec le ligament annulaire intact, puis relâché. Le déplacement de la tête radiale fut quantifié avec le ratio radio-capitellaire. Une interaction significative fut découverte entre les positions du coude, les angles de malalignement et l’intégrité du ligament annulaire. La subluxation de la tête radiale fut accentuée lors de la déchirure du ligament annulaire. Une augmentation de la subluxation antérieure de la tête radiale fut observée lorsque le malalignement était fixé en extension et lors de mouvements de flexion progressive du coude. D’autre part, un malalignement en flexion et une extension graduelle du coude occasionnait une subluxation postérieure. En conclusion, les résultats ont démontré l’importance d’une reconstruction anatomique du cubitus proximal, car un malalignement de 5 degrés engendre une subluxation de la tête radiale, surtout lors d’une déchirure du ligament annulaire.
Resumo:
O objetivo do estudo foi avaliar a eficácia do fixador esquelético pino-resina, configuração tipo II, coadjuvado pelo enxerto ósseo esponjoso autólogo, no tratamento das complicações secundárias à imobilização inadequada de fraturas do rádio e ulna em 10 cães, com peso entre 1,8 e 33,6 kg. Detectou-se não-união (n=4), osteomielite (n=1), má-união (n=1), falência ou quebra de implante (n=4), sendo 60% das lesões referente ao uso prévio de pino intramedular no rádio. A montagem do fixador foi realizada com transfixação de pinos lisos em sua maioria angulados, cujas extremidades excedentes foram dobradas e estabilizadas com resina acrílica. em todos os casos, utilizou-se enxerto esponjoso autólogo fresco, após debridamento do foco de fratura. O tempo de permanência do aparelho variou entre 45 dias e 5 meses e a maior complicação foi o afrouxamento dos pinos transfixantes. A consolidação das fraturas ocorreu por formação de calo periosteal de mínimo a moderado, indicando boa rigidez da montagem.
Resumo:
Fractures of the severely atrophic (<10 mm) edentulous mandible are not common, and these fractures with a vertical height of 10 mm or less have long been recognized as being particularly problematic. Although there are advances in the treatment of the atrophic mandibular fracture, the treatment remains controversial. There are some options for treatment planning because of using small miniplates to large reconstruction plates. However, when the fixation method fails, it causes malunion, nonunion, and/or infection, and sometimes it has been associated with large bone defects. The authors describe a clinical report of a failed miniplate fixation for atrophic mandibular fracture management. The authors used a load-bearing reconstruction plate combined with autogenous bone graft from iliac crest for this retreatment. The authors show a follow-up of 6 months, with union of the fracture line and no complication postoperatively. © 2013 by Mutaz B. Habal, MD.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Our goal was to study the use of 2.0-mm miniplates for the fixation of mandibular fractures. Records of 191 patients who experienced a total of 280 mandibular fractures that were treated with 2.0-mm miniplates were reviewed. One hundred twelve of those patients, presenting 160 fractures, who attended a late follow-up were also clinically evaluated. Miniplates were used in the same positions described by AO/ASIF. No intermaxillary fixation was used. All patients included had a minimum follow-up of 6 months. Demographic data, procedures, postoperative results, and complications were analyzed. Mandibular fractures occurred mainly in males (mean age, 30.3 years). Mean follow-up was 21.92 months. The main etiology was motor vehicle accident. The most common fracture was the angle fracture (28.21%). Twenty-two fractures developed infection, for an overall incidence of 7.85%. When only angle fractures are considered, that incidence is increased to 18.98%. Although only 1 patient (0.89%) described inferior alveolar nerve paresthesia, objective testing revealed sensitivity alterations in 31.52% of the patients who had fractures in regions related to the inferior alveolar nerve. Temporary mild deficit of the marginal mandibular branch was observed in 2.56% of the extraoral approaches performed and 2.48% presented with hypertrophic scars. Incidence of occlusal alterations was 4.0%. Facial asymmetry was observed in 2.67% of the patients, whereas malunion incidence was 1.78%. Fibrous union, mostly partial, occurred in 2.38% of the fractures, but only 1 of those presented with mobility (0.59%). Condylar resorption developed in 6.25% of the fixated condylar fractures. Mean mouth opening was 42.08 mm. The overall incidence of complications, including infections, was similar to those described for more rigid methods of fixation.
Resumo:
Congenital pseudarthrosis of the tibia (CPT) is caused by an ill-defined, segmental disturbance of periosteal bone formation leading to spontaneous bowing, followed by fracture and subsequent pseudarthrosis in the first 2 years of life. The results of conventional treatment modalities (e.g., bracing, internal and external fixation and bone grafting) are associated with high failure rates in terms of persisting pseudarthrosis, malunion and impaired growth. As a more promising alternative, a more aggressive approach, including wide resection of the affected bone, reconstruction with free vascularised fibula grafts from the healthy contralateral leg and stable external fixation at a very early stage has been suggested. Between 1995 and 2007, 10 children (age 12-31 months, median 20 months) suffering from CPT were treated at our institutions according to this principle. Two patients were treated before a fracture had occurred. The length of the fibula graft was 7-9cm. End-to-end anastomoses were performed at the level of the distal tibia stump. The follow-up was 80 months (median, range 12 months to 12 years). Radiologic examination at 6 weeks postoperatively showed normal bone density and structure of the transplanted fibula in all cases and osseous consolidation at 19 of the 20 graft/tibia junctions. One nonunion was sucessfully treated with bone grafting and plate osteosynthesis. Pin-tract infection occurred in three patients. Five children sustained graft fractures that were successfully treated with internal or external fixation. Two patients developed diminished growth of the affected limb or foot; all others had equal limb length and shoe size. At long-term follow-up, tibialisation of the transplant had occurred, and normal gait and physical activities were possible in all children. We conclude that in spite of a relatively high complication rate and the reluctance to perform free flap surgery in infants at this young age, the present concept may successfully prevent the imminent severe sequelae associated with CPT.
Resumo:
Refixation of a trochanteric osteotomy carries a high complication rate. To enhance stability and facilitate anatomic reduction of the trochanteric fragment, we have introduced a stepped osteotomy. Between April 2006 and June 2007, we performed surgical hip dislocations using the modified trochanteric osteotomy combined with a relatively aggressive rehabilitation program. Full weightbearing was allowed at a mean of 42 days (range, 33-54 days). The minimum followup was 8 months (median, 13 months; range, 8-24 months). Postoperative radiographs were assessed prospectively for consolidation or the appearance of malreduction/nonunion/malunion of the osteotomy and heterotopic ossification. In 110 of 113 hips, the trochanteric osteotomy healed in the anatomic position. Two patients had a trochanteric delayed union with loss of anatomic position, and one additional patient underwent revision surgery for a pseudarthrosis and cranial migration of the trochanteric fragment. All three complications related to healing occurred in the first 60 patients when the step height was 3 to 4 mm. After increasing the step heights to 6 mm, we observed no healing complications. Despite more aggressive postoperative mobilization, the incidence of malunion or nonunion related to the new stepped osteotomy is low and approaches zero for steps of 6 mm. It is now our technique of choice.
Resumo:
PURPOSE A common treatment for pediatric femur fractures is intramedullary nail (IMN) insertion. Elastic stable intramedullary nails (ESINs) are often used for these procedures in heavier patients, but the potential for complications and malunion is greater. We describe here a rigid IMN specifically designed for adolescents, the adolescent lateral entry femoral nail (ALFN). The purpose of this study was to compare the recovery and complications for patients treated with ESINs to those treated with the ALFN. METHODS Our study design was a retrospective cohort study. We performed a review of medical records of 22 children ages 10-17 requiring surgical fixation of a femur fracture for a 2½-year period. Patients selected for the study had traumatic diaphyseal femur fractures and were treated with ESINs without end-caps or ALFNs. Our analyses evaluated injury, surgical, and outcome information for all patients. RESULTS Twenty-two patients were eligible for inclusion and were divided into two groups according to their treatment: the ESIN group with 7 patients and the ALFN group with 15 patients. We then performed a comparison of complications and recovery for these patients. The mean time to full weight-bearing was significantly less for the ALFN group (4.1 weeks; SD, 2.2), than the ESIN group (9.4 weeks; SD 3.9). There was no statistical difference in the incidence of major or minor complications. CONCLUSIONS Older, heavier pediatric patients treated for femur fracture with ALFNs had a shorter recovery time than similar patients treated with ESINs. However, the outcomes for both groups were satisfactory.